• 제목/요약/키워드: wet-dry

검색결과 1,952건 처리시간 0.027초

COMPARISON OF SHADE CHANGES ACCORDING TO DRY/WET CONDITION OF TEETH USING INTRA-ORAL COLORIMETER

  • Lee, Dong-Hwan;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jai-Bong
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.314-321
    • /
    • 2005
  • Objectives. The purpose of this study was to compare the shade changes in wet and dry conditions of natural teeth using two different intra-oral colorimeters. Materials and methods. Twenty volunteer subjects have no restorations and fillings in the maxillary central incisors were involved in this clinical study. The color of tooth was measured by two different instruments that were a Shade $Scan^{TM}$ System and a VITA $Easyshade^{(R)}$, Five times consecutive measurements were done for each subject with both instruments. Groups of measurement are an initial wet condition as control, dry in 5 minutes, 15 seconds after re-wetting with saliva, re-wetting after 5minutes and re-wetting after 30 minutes. Using ShadeScan $System^{TM}$, tooth image was captured and converted to the mapping image of Vitapan 3D master. Three main shades were chosen from each subject and calculated the area in Global Lab Image software. Data were analyzed using paired T-Test and Wilcoxon Signed Ranked Test. Using VITA $Easyshade^{(R)}$, color differences($\Delta$E) between measurements were analyzed with one sample T-test. Results. Using ShadeScan $System^{TM}$, there were significant differences between control group and dry(P=.023), dry and re-wetting 15 seconds, 5 minutes, 30 minutes as well(P=.021, P=.017, P=.030) in comparison of primary shade. However, comparing three main shades, there was no significant difference between control and dry(P=.105). Using VITA $Easyshade^{(R)}$, color differences($\Delta$E) between control and dry, dry and re-wetting 30 minutes were statistically different(P=.002, P=.022). Conclusion. Primary shade could be changed in dry and wetting procedure in time, however there was no significant shade changes in overall.

현장 시공성 개선을 위한 롤타입 건식바닥난방시스템 개발 (A Study on the Development of Rolled Dry Floor Heating System for Improving Workability)

  • 이규동;김준호;정창호;김동우;小川慶一郞
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.177-180
    • /
    • 2012
  • Korea residential housing generally use wet floor heating system 'Ondol' which consist of insulation cushioning, lightweight foamed concrete, hot water pipe and mortar on top of reinforced concrete slab. Wet floor heating system's installation process is too complicate and difficult to supervise field for continuing assurance quality. Also, this method has a huge impact on the progress of construction because it take a long time to cure finishing mortar and lightweight foamed concrete. Therefore, it is considered a disturbance factor of reduction of construction duration for enhancing competitiveness. In this study, we conducted an experiment about the radiant heat performance and temperature difference on upper panel of rolled dry floor heating systems which is jointly developed by Kolon global and Sumisho Metalex for remodeling housing, studio apartment and the urban-life housing.

  • PDF

Topography in intertidal zone by satellite images

  • Kang, Yong-Q.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.664-669
    • /
    • 2002
  • Intertidal zone (tidal flat) is a place which is sometimes dry and sometimes wet depending on the tidal rhythm. Direct measurement of topography in the intertidal zone is very difficult to be achieved. The interface between wet and dry parts in the tidal flat, which can be identified from near infrared band of satellite image, is a 'depth contour' which corresponds to the sea level at the time of satellite pass. Aquisition of topography data in tidal flat is possible by combining various techniques such as (1) identification of the interface between wet and dry parts, (2) GCP correction of satellite image, and (3) realtime prediction of sea level elevation at the time of satellite pass. The algorithm was successfully applied in obtaining topography (bathymetry) data in the intertidal zone of Asan Bay in the west coast of Korea from 26 satellite images. The method is expected to be very efficient in making bathymetry data base in the western and southern parts of Korea where tidal flats are well developed in wide regions.

  • PDF

착상을 수반한 핀-관 열교환기의 성능평가계수에 관한 연구 (The Study of Performance Evaluation Coefficient of Fin-and-Tube Heat Exchangers with Frosting)

  • 최봉준;황준현;신종민
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.132-136
    • /
    • 2003
  • For the study of performance evaluation on different shape heat exchangers that have the same energy consumption in a refrigerator, we make performance evaluation coefficient (PEC) which can distinguish performance of different shape heat exchangers. The results were reported in order to compare with for the dry frosting and wet frosting test as various definition of PECs. Results showed that PEC of dry frosting test is higher than that of wet frosting test because attached water droplet increases pressure drop of air-side then this decreases performance of heat exchanger.

TiAlN 코팅드릴의 구멍가공특성에 관한 연구 (A Study on the Drilling Characteristics of a TiAlN Coated Twist Drill)

  • 김태영;신형곤;김종택;김민호;이한교
    • 한국기계가공학회지
    • /
    • 제3권4호
    • /
    • pp.29-36
    • /
    • 2004
  • An experimental study on drilling of stainless steel is conducted using TiAlN coated drills and HSS twist drills with several cutting conditions; feed rate, spindle rotational speed, and dry/wet cutting. The effects of number of hole on the thrust force are examined by cutting force measurement. The flank wear of the drills and the change of hole diameter are quantitatively observed using a vision system. It is found that the thrust force in drilling with TiAlN coated drills decrease under dry and wet machining, whereas the flank wear resistance is improved.

  • PDF

고구마, 감자 및 돼지감자 분말(粉末)을 이용(利用)한 합판용(合板用) 요소수지(尿素樹脂)의 증량(增量)에 관(關)한 연구(硏究) (A study on the utilization of potato, sweet potato, and jelusalem artichoke flour as an extender of urea formaldehyde resin for plywood)

  • 이필우;이화형
    • Journal of the Korean Wood Science and Technology
    • /
    • 제1권2호
    • /
    • pp.11-15
    • /
    • 1973
  • This study was carried out to utilize sweet potato, and jerusalem artichoke flour as an extender of urea formaldehyde resin for plywood manufacture. The results obtained are summarized as follows: 1) In dry and wet test of plywood, sweet potato flour extended in urea formaldehyde resin was shown better strength than those of wheat flour. 2) Sweet potato flour was shown good results up to 200 percent extension in the dry test, and there was not shown significant difference between 100 percent and 150 percent extension in the wet test. 3) In the case of 100 percent extension, potato flour was shown best dry shear strength(400 psi) and sweet potato flour was shown best wet shear strength (212 psi).

  • PDF

SWMM 모형을 이용한 유역의 오염부하량 산정 (Estimation for Watershed pollutant loading with SWMM)

  • 전지홍;윤춘경
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.689-694
    • /
    • 1999
  • This study estimated average yearly watershed pollutant loading by using SWMM(Storm Water Management Model) which is one of the nonpoint source quality models. Two sites were measured discharge and water quality at dry period and wet period. The rainfall data is used from 1989 to 1998 . During a decade, the average year watershed pollutant loading, which is SS, BOD5 , TN, TP, were 2.39E+06kg, 0.92E +05kg, 2.53E+05kg, 2.66E+04kg respectively. During dry period, SS, BOD5 TN, TP loadings were 1.89E+05kg, 1.7E+05kg, 1.04E+05kg, 1.11E+04kg, and during wet period 1.89E+05kg, 1.17E+05kg, 1.04E+05kg, 1.11E+04kg respectively so wet period loading are more than dry day loadings.

  • PDF

인공오손에 따른 배전기자재의 건조 및 습윤 섬락에 관한 연구 (The Study on the Dry and Wet Flashover Voltages of the Artificially Salt Contaminated Distribution Facilities)

  • 김찬영;김동명;권태호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.487-488
    • /
    • 2008
  • The dry and wet flashover characteristics on the contaminated distribution facilities was investigated. The test were carried out on the suspension insulator, line post insulator, lightning arrester, cut off switch, etc. In the dry state, the flashover voltages of facilities contaminated with B, C, D classes are similar to the non-contaminated ones. However, in the wet state, the flashover voltages of facilities contaminated with B, C, D classes are decreased. The flashover voltages of some few facilities show under the standard value. This results indicate that the high humidity may cause the flashover on distribution facilities.

  • PDF

알루미나 세라믹 가소결재의 피삭성 -다이아몬드 및 CBN공구의 절삭 성능- (Machinability of Pre-sintered Alumina Ceramics)

  • 김성청
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1996년도 춘계학술대회 논문집
    • /
    • pp.41-46
    • /
    • 1996
  • In this study, unsintered and pre-sintered low purity alumina ceramics were machined with various tools to clarify the machinability, optimum tool materials and optimum cutting conditions. The main conclusions obtained were as follows. (1)In the case of dry cutting, the sintered diamond and natural diamond tools exhibit better performance in machining of the ceramic pre-sintered at lower temperature, and the tool lives of both tools in machining the ceramics pre-sintered at high temperature becomes extremely short. (2)The performance of CBN tool becomes better in dry machining of the ceramics pre-sintered at higher temperature. (3)When the pre-sintered ceramics were wet machined with sintered diamond, the tool life becomes considerably long, and higher cutting speed can be used than in the case of the CBN and ceramic tools, the tool lives becomes shorter at wet cutting than at dry cutting, especially exhibiting extremely short tool life in wet cutting with ceramic tool.

  • PDF

An Experimental Study of the Airside Performance of Slit Fin-and-Tube Heat Exchangers under Dry and Wet Conditions

  • Chang, Keun-Sun;Long, Phan-Than
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권1호
    • /
    • pp.7-14
    • /
    • 2009
  • Water condensate accumulated on the surface of a fin-and-tube heat exchanger significantly affects its thermal and hydraulic performances. The purpose of this study is to investigate the effects of condensate retention on the air-side heat transfer performance and flow friction for various flow and geometric conditions. Total of twelve samples of slit and plate fin-and-tube heat exchangers are tested under dry and wet conditions. The thermal fluid measurements are made using a psychrometric calorimeter. Frontal air velocity varies in the range from 0.7 m/s to 1.5 m/s. Using the experimental data, presented are heat transfer coefficients in terms of Colburn j-factors and friction factors, and these data are compared with the existing correlations.