• Title/Summary/Keyword: wet friction coefficient

Search Result 44, Processing Time 0.029 seconds

Wet Surface Performance Test of PF Heat Exchanger (PF열교환기의 습표면 성능시험)

  • Cho, J.P.;Kim, N.H.;Choi, K.K.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.314-320
    • /
    • 2000
  • In this study, the wet surface heat transfer coefficients and friction factors of PF heat exchangers are presented. Two sample with different fin pitch(1.25mm, 1.5mm) were tested. Tests were conducted in a open loop wind tunnel. The wet surface heat transfer coefficient was reduced following the procedure given in ARI 410-81. Results showed that the heat transfer coefficients of the heat exchanger with 1.5mm fin pitch were approximately the same as those with 1.25mm fin pitch, except at low reynolds number(Re<100), where the heat transfer coefficients of 1.5mm fin pitch were slighly higher than those with 1.25mm fin pitch. The friction factors of the 1.25mm fin pitch, however was 120 % to 160 % higher than those of the 1.5mm fin pitch. The wet surface heat transfer coefficients were lower than those of the dry surface. The wet surface friction factors, however, were higher than those of the dry surface.

  • PDF

Fiction Coefficient between Abutment Materials and Clasp Materials and Estimation of Retention Force of Circumferential Clasp (지대치의 재료와 Clasp 재료 사이의 마찰계수와 원형 clasp의 유지력 추정)

  • Lim, Dong-Chun
    • Journal of Technologic Dentistry
    • /
    • v.21 no.1
    • /
    • pp.67-75
    • /
    • 1999
  • The purpose of this study is to evaluate the friction coefficients between abutment materials and clasp materials, and to an estimation formula for retention force. The coefficients of friction between three clasp materials and four abutment materials were measured under various conditions, polished and sandblasted and wet and dry. The measurement was repeated for each combination up to a total measurement of 1200 times. Estimation formula for retention force is measured as sum of two terms, which the one time is proportional to the product of friction coefficient ${\mu}$ and undercut u and the other term is proportional to u-squared. Two proportional coefficient were obtained by least square method. The results are as follows: 1. Friction coefficients were ranged from 0.08 to 0.53 under various conditions. 2. Friction coefficients of non-metal abutment materials are greater in wet conditions than dry conditions. 3. Friction coefficients of sandblasted clasp against abutment are greater than that of polished clasp. 4. Clasp retention force can be estimated with the model as F=$F_d(3.0{\mu}u+1.5u^2/h)$ with minor error.

  • PDF

Frictional Characteristics of Woven and Nonwoven Wipes

  • Das A.;Kothari V. K.;Mane D.
    • Fibers and Polymers
    • /
    • v.6 no.4
    • /
    • pp.318-321
    • /
    • 2005
  • Demand for the fabric wipes is growing continuously. Wipes in industry are used for cleaning purpose. Cleaning involves rubbing action, so it is very important to know how much frictional force is encountered during the cleaning action. In this study the effects of normal load, sliding speed on frictional characteristics of nonwoven and woven wipes, both dry and wetted with different liquids, against glass and floor tile surfaces have been reported. With the increase in the normal load the coefficient of friction goes on decreasing for both nonwoven and woven wipes and this trend is observed in both dry and wet wipes. The coefficient of friction of both nonwoven and woven wipes against glass surface is in general higher than the floor tile surface. The wipes wetted with water shows an increase in coefficient of friction as compared to dry sample, but there is reduction in the coefficient of friction when the wipe samples are wetted with vegetable oil. In case of dry wipes, the coefficient of friction in case of nonwoven wipe is higher than the woven wipe. In case of woven wipes, the ranges of coefficient of friction either due to change in liquid type, normal load or sliding speed are in general smaller than that in case of nonwoven fabrics.

A Study on the Application of Runway Friction Measurements (활주로 마찰계수 측정 및 적용에 관한 연구)

  • Noh, Kun-Soo
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.24 no.3
    • /
    • pp.62-68
    • /
    • 2016
  • According to the accident/incident reports of aircraft runway overruns and excursions, it generally shows runway friction reduction and aircraft braking capability deterioration are the basic causes due to adverse weather. Although surface of paved runway gets wet, it also should give good friction capability. If runway surface is worn due to long time usage and friction capability is reduced due to rubber accumulation or weather conditions(snow, rain, ice etc.), airport authorities should rapidly measure friction coefficient and give them to relevant persons through aeronautical information system and support safe takeoff and landing. Operation wise, these information of friction coefficient reduction should be lead to aircraft performance adjustments, but the data from manufacturer(performance manual) are airplane braking coefficient and the data from airport authorities are vehicle measured braking coefficient. But these two data are considered as the same meaning although the definite relationship between them is not clarified yet. So I am trying to search for the technical background of these two data and suggest reasonable method to use them efficiently.

The Evaluation for Slip Risk of Various Hospital's zones (병원 내 다양한 구역의 미끄럼 위험성 평가 연구)

  • Kang, Hyun-Su;Park, Peom
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.81-89
    • /
    • 2016
  • Floor slipperiness is a leading cause in slip and fall accidents which are a major source of occupational injuries in Korea. Researchers have estimated the slip and fall related accidents rank number one or two in number of the injured. The objectives of this study were to find the field contamination effect and improvement countermeasure. Slipping and falling are common accidents in large public facilities, especially facility which vulnerable adults generally use as like hospital. So, we measured the coefficient of friction of several floors on the floor in hospital, under dry and wet using BOT-3000. The results of the coefficient of friction measurements showed that floor type and surface conditions were all significant factors affecting the coefficient of friction. The most surprising finding of this study was that there were significant friction improvement when the floors were properly cleaned with cleaning equipments.

Heat Transfer and Friction Characteristics of Slit Fin and Tube Heat Exchangers in Wet Conditions (습표면 조건에서 슬릿 핀-튜브 열교환기의 열전달 및 압력강하 특성)

  • Chang, Keun-Sun;Phan, Thanh-Long
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • Water condensate accumulated on the surface of a fin-and-tube heat exchanger significantly affects its thermal and hydraulic performance. The purpose of this study is to investigate the effect of condensate retention on the air-side heat transfer performance and flow friction. Total 12 samples of slit and plate fin-and-tube heat exchangers with varying fin spacing and number of tube rows are tested under dry and wet conditions. The thermal fluid measurements are made using a psychometric calorimeter. Frontal air velocity varies in the range from 0.7 m/s to 1.5 m/s. Using the experimental data, presented are the heat transfer coefficients in terms of Colburn j-factor and friction factor.

COMPARISON OF THE FRICTIONAL RESISTANCE BETWEEN NON-ION PLATED AND TiN ION PLATED TO THE ORTHODONTIC APPLIANCE (TiN피막 처리된 교정 장치물의 마찰 저항력에 관한 비교연구)

  • Jang, Si-Ho;Kwon, Oh-Won;Kim, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.23 no.4 s.43
    • /
    • pp.671-691
    • /
    • 1993
  • To estimate the possibility in the application of TiN ion-plating to the orthodontic appliance, this study investigated frictional force and frictional coefficient between non-ionplated and TiN ion-plated to the orthodontic appliance. The obtained results were as follows : 1. For each group, the frictional force between metal bracket and arch wire in the wet condition was exhibited lower than that in the dry condition. 2. In the dry condition, the frictional force was lowest with fourth group, and it increased in the order of the 3rd, 1st, and 2nd group. Same situation happened in the wet condition. 3. Experimental results using ceramic & plastic bracket showed that group B was lower than group A, and group D was similar to group C. 4. The surface texture after experiment showed that the scratch due to a friction with bracket was observed in an arch wire of dry contition. Also the surface of bracket was rougher than before. 5. We observed that a specimen surface processed with the TiN ion plating was smoother than that of without the TiN ion plating. 6. The surface texture of a metal bracket and an arch wire in the wet condition was observed smoother than that in the dry condition. 7. In the dry condition, the friction coefficient of each specimen was very similar to each other, but in the wet condition, the friction coefficient of specimen processed with the TiN ion plating showed lower values.

  • PDF

Evaluation of Air-side Heat Transfer and Friction Characteristics on Design Conditions of Evaporator (증발기의 설계조건에서 공기측 열전달계수 및 압력강하 산출)

  • 김창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1007-1017
    • /
    • 2003
  • An experimental study on the air-side pressure drop and heat transfer coefficient of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side heat transfer coefficients in the literature is not based on a consistent approach. This paper focuses on new method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry and wet surface heat transfer estimation in fin-tube heat exchanger having refrigerant on the tube-side. Results are presented as plots of friction f-factor and Colburn j -factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of 150∼250 kg/$m^2$s with air flows at velocity ranges from 0.3 m/s to 0.8 m/s.

An Experimental Study on the Effect of the Air Temperature on the Air-Side Heat-Transfer Coefficient and the Friction Factor of a Fin-and-Tube Heat Exchanger (외기 온도 변화가 핀-관 열교환기의 공기측 열전달계수와 마찰계수에 미치는 영향에 관한 실험적 연구)

  • Kim, Nae-Hyun;Cho, Honggi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.4
    • /
    • pp.149-158
    • /
    • 2017
  • In general, the air-side j and f factors of evaporators or condensers are obtained through single-design tests performed under air-dry and wet-bulb temperatures. Considering that the indoor or outdoor air temperatures vary significantly during the operation of an air conditioner, it is necessary to confirm that the experimentally-obtained j and f factors are widely applicable under variable air conditions. In this study, a series of tests were conducted on a two-row slit-finned heat exchanger to confirm the applicability. The results showed that, for the dry-surface condition, the changes of the tube-side water temperature, water-flow rate, and air temperature had virtually no effect on the air-side j and f factors. For the wet condition, however, the f factor was significantly affected by these changes; contrarily, the j factor is relatively independent regarding this change. The formulation of the possible reasoning is in consideration of the condensation behavior underneath the tube. The wet-surface j and f factors are larger than those of the dry surface, with a larger amount for the f factor.

Analysis of the Friction Characteristics of Parking Brake for Excavator According to Manufacturing Methods of Friction Disc (굴삭기용 주차 브레이크의 마찰 판 제작방법에 따른 마찰특성 분석)

  • Lee, Y.B.;Sung, B.J.;Park, J.W.;Kim, K.M.
    • Journal of Power System Engineering
    • /
    • v.16 no.6
    • /
    • pp.66-72
    • /
    • 2012
  • The parking brake embedded in track driving motor for driving an excavator is composed of wet type multi-friction discs. This type parking brake can be designed more compact because the combination of some sheets of friction discs generate great braking power, and also it has good braking characteristic and long life time because it works in the oil. In this study, we analyzed torque characteristic of the parking brake through simulations and performed experiments by use of 3-kinds of paper friction sheet manufactured by different pressing methods. And, we compared the maximum static friction coefficient and torque characteristic with the simulation results and confirmed the optimal manufacturing process through this result.