• 제목/요약/키워드: wet bulb temperature

검색결과 87건 처리시간 0.03초

2018년 폭염 기간 동안 경북의 내륙과 해안 도시 간 열 환경 비교 - 대구와 포항의 비교 - (Comparison of Thermal Environment between Inland and Coastal Cities in Gyeongbuk during the Heat Wave of 2018 - Comparison between Daegu and Pohang -)

  • 추승현;안은지;김해동
    • 한국환경과학회지
    • /
    • 제30권8호
    • /
    • pp.621-628
    • /
    • 2021
  • The characteristics of time changes in air temperature, DI (discomfort index) and WBGT (wet-bulb globe temperature) were investigated for inland city (daegu) and coastal city (pohang) of Gyeongbuk Province during the 2018 consecutive heat wave season. The time when the temperature dropped below 33℃ was around 19h in both regions. As such, the two regions were similar with respect to the time up to which the heatwave warning levels continued. However, the discomfort index (DI) was higher than 27 in Pohang. Most people feel unpleasant when an discomfort index of 27 or higher appears. The results indicated that Korea's night-time thermal environment during the summers is particularly poor in the southern coastal areas. WBGT began at 09:00 and lasted until 21:00, with a score of 31 or higher; this score, in principle, corresponded with the duration of outdoor activity in both regions. Therefore, it was found that outdoor work was at a level where all day long had to be stopped in both areas during the heat wave. Although time changes in temperature and WBGT were similar in both regions, Discomfort Index (DI) differed significantly. The difference refers to the fact that Pohang is strongly affected by the high heat capacity effect and the supply of water vapor from the sea.

대구의 여름철 도로 열 환경과 클린로드 시스템의 효과 조사를 위한 관측연구 (Observational Study to Investigate Thermal Environment and Effect of Clean- Road System over a Broad Way of Daegu in Summer)

  • 김성락;정응호;김해동
    • 한국환경과학회지
    • /
    • 제24권9호
    • /
    • pp.1171-1180
    • /
    • 2015
  • To investigate thermal environment and effect of clean-road system over a broad way, we conducted the filed meteorological observation during 12~13 August 2014. The clean-road system was employed over a part of the broad way of Dalgubul(Dalgubul-Daero) by Daegu Metropolitan city in 2011. The clean-road system in general is operated two times(4 am, 2 pm) during summertime. In case of scorching alert, the system is operated 3 times a day(4 am, 2 pm and 4 pm). To evaluate the present thermal condition and the improvement effects due to the system, we analyzed the time variation of discomfort index and WBGT(wet-bulb and globe temperature). WBGT was more than 25 during 8 a.m. ~ 9 p.m. And discomfort index was more than 75 during 8 a.m. ~ 11 p.m. The thermal improvement effect of the clean-road system was restrictive during daytime.

채널이 수막으로 완전히 덮여 있는 증발식 냉각기에서의 열 및 물질전달 해석 (Analysis of Heat and Mass Transfer in an Evaporative Cooler with Fully Wetted Channel)

  • 송찬호;이대영;노승탁
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1766-1775
    • /
    • 2001
  • A theoretical analysis on the heat and mass transfer in an evaporative cooler is presented in this work. The evaporative cooler is modeled as a channel filled with porous media the interstitial surface of which is covered by thin water film. Assuming that the Lewis number is unity and the water vapor saturation curve is linear, exact solutions to the energy and vapor concentration equations are obtained. Based on the exact solutions, the characteristics of the heat and mass transfer in the evaporative cooler are investigated. The comparison of the cooling performance between the evaporative cooler and the usual sensible heat exchanger is also carried out. Obviously, the evaporative heat exchanger shows better cooling performance than the sensible heat exchanger. This is due to the latent heat of water vaporization, which results in apparent increases both in the interstitial heat transfer coefficient and the specific heat of the air stream in the evaporative cooler.

Spatial Changes in Work Capacity for Occupations Vulnerable to Heat Stress: Potential Regional Impacts From Global Climate Change

  • Kim, Donghyun;Lee, Junbeom
    • Safety and Health at Work
    • /
    • 제11권1호
    • /
    • pp.1-9
    • /
    • 2020
  • Background: As the impact of climate change intensifies, exposure to heat stress will grow, leading to a loss of work capacity for vulnerable occupations and affecting individual labor decisions. This study estimates the future work capacity under the Representative Concentration Pathways 8.5 scenario and discusses its regional impacts on the occupational structure in the Republic of Korea. Methods: The data utilized for this study constitute the local wet bulb globe temperature from the Korea Meteorological Administration and information from the Korean Working Condition Survey from the Occupational Safety and Health Research Institute of Korea. Using these data, we classify the occupations vulnerable to heat stress and estimate future changes in work capacity at the local scale, considering the occupational structure. We then identify the spatial cluster of diminishing work capacity using exploratory spatial data analysis. Results: Our findings indicate that 52 occupations are at risk of heat stress, including machine operators and elementary laborers working in the construction, welding, metal, and mining industries. Moreover, spatial clusters with diminished work capacity appear in southwest Korea. Conclusion: Although previous studies investigated the work capacity associated with heat stress in terms of climatic impact, this study quantifies the local impacts due to the global risk of climate change. The results suggest the need for mainstreaming an adaptation policy related to work capacity in regional development strategies.

대향류형 냉각탑에 대한 설계 및 성능해석을 위한 수치해석적 연구 (Numerical study for performance analysis and design of a counterflow type cooling tower)

  • 이상윤;이정희;최영기;유홍선
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.535-549
    • /
    • 1998
  • A numerical study for performance analysis of a counterflow type forced draft tower and natural draft cooling tower has been performed based on the method using the finite volume method with non-orthogonal body fitted and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy balance, moisture fraction balance, water enthalpy balance, and water mass balance equations are solved with Navier-Stoke’s equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study, The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also peformed.

  • PDF

Numerical Study for the Performance Analysis and Design of a Crossflow- Type Forced Draft Cooling Tower

  • Choi, Young-Ki;Kim, Byung-Jo;Lee, Sang-Yun;Lee, Jung-Hee
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권1호
    • /
    • pp.1-13
    • /
    • 2000
  • A numerical study for performance analysis of a crossflow-type forced draft cooling tower has been performed based on the finite volume method with non-orthogonal body fitted, and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy, moisture fraction, water enthalpy, and water mass balance equations are solved with Navier-Stoke's equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study. The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also performed.

  • PDF

외기 온·습도 변화에 따른 종이재질 전열교환 엘리먼트 성능에 관한 연구 (Thermal Performance of an Enthalpy Exchanger Made of Paper at Different Outdoor Temperatures and Humidities)

  • 김내현;이을종;송길섭;오왕규
    • 대한기계학회논문집B
    • /
    • 제34권7호
    • /
    • pp.697-702
    • /
    • 2010
  • 전열교환 엘리먼트는 열회수형 환기유닛의 핵심부품으로, 외기와 실내공기의 열 및 수분교환이 이루어진다. 본 연구에서는 현재 국내에서 사용되고 있는 전열교환 엘리먼트에 대하여 외기의 온 습도 변화가 전열교환 엘리먼트의 성능에 미치는 영향을 실험적으로 연구하였다. 전열교환 엘리먼트를 통과 하는 공기 유량, 입 출구의 건 습구 온도를 정밀하게 측정할 수 있는 실험장치를 특별히 제작하였고, 항온항습실내에서 외기의 상대습도 또는 절대습도를 변화시키며 실험을 수행하였다. 실험결과는 현열전달 유용도과 잠열전달 유용도으로 평가되는데 잠열 전달 유용도는 외기의 상대습도의 증가에 따라 증가하였으나 절대습도의 변화에는 거의 무관하게 냐타났다. 한편 현열 교환 유용도는 외기의 온도 및 습도 변화에 무관하게 일정하였다.

라디오미터를 이용한 겨울철 강수형태 결정 및 예측가능성 고찰 (Determination and Predictability of Precipitation-type in Winter from a Ground-based Microwave Radiometric Profiler Radiometer)

  • 원혜영;김연희;장동언
    • 대기
    • /
    • 제20권3호
    • /
    • pp.229-238
    • /
    • 2010
  • The 1,000~500 hPa thickness and the $0^{\circ}C$ isotherm at 850 hPa have been used as the traditional predictors for wintertime precipitation-type forecasts. New approaches are taking on added significance as preexistence method of determination for wintertime precipitation-type exhibits more or less prevalent false alarms. Moreover thicknesses and thermodynamic profiles from ordinary upper-air observation were not adequate to monitor the atmospheric structure. In this regard, Microwave radiometric profiler microwave radiometer is useful in wintertime precipitation-type forecasts because radiometric measurements provide soundings at high temporal resolution. In this study, the determination and the predictability of wintertime precipitation-type were examined by using the calculated thicknesses, temperature of 850 hPa (T850) from a microwave radiometer, and surface observation at National Center for Intensive Observation of severe weather (NCIO) located at Haenam, Korea. The critical values for traditional predictors (thickness of 1000~500 hPa and T850) were evaluated and adjusted to Haenam region because snow rarely occurred with a 1000-500 hPa thickness > 5,300 m and T850 > $-10^{\circ}C$. Three thicknesses (e.g., 1,000~850, 1000~700, and 850~700 hPa thickness), T850, surface air temperature, and wet-bulb temperature were also evaluated as the additional predictors. A simple nomogram and a flow chart were finally designed to determine the wintertime precipitation-type using the microwave radiometer. The skill scores for the predictability of precipitation-type determination are considerably improved and the predictors showed the temporal variations in 12 hours before precipitation. We can monitor the hit and run snowfall in winter successful by realtime watch of the predictors, especially in commutes of big cities.

Climate Warming and Occupational Heat and Hot Environment Standards in Thailand

  • Phanprasit, Wantanee;Rittaprom, Kannikar;Dokkem, Sumitra;Meeyai, Aronrag C.;Boonyayothin, Vorakamol;Jaakkola, Jouni J.K.;Nayha, Simo
    • Safety and Health at Work
    • /
    • 제12권1호
    • /
    • pp.119-126
    • /
    • 2021
  • Background: During the period 2001 to 2016, the maximum temperatures in Thailand rose from 38-41℃ to 42-44℃. The current occupational heat exposure standard of Thailand issued in 2006 is based on wet bulb globe temperature (WBGT) defined for three workload levels without a work-rest regimen. This study examined whether the present standard still protects most workers. Methods: The sample comprised 168 heat acclimatized workers (90 in construction sites, 78 in foundries). Heart rate and auditory canal temperature were recorded continuously for 2 hours. Workplace WBGT, relative humidity, and wind velocity were monitored, and the participants' workloads were estimated. Heat-related symptoms and signs were collected by a questionnaire. Results: Only 55% of the participants worked in workplaces complying with the heat standard. Of them, 79% had auditory canal temperature ≤ 38.5℃, compared with only 58% in noncompliant workplaces. 18% and 43% of the workers in compliant and noncompliant workplaces, respectively, had symptoms from heat stress, the trend being similar across all workload levels. An increase of one degree (C) in WBGT was associated with a 1.85-fold increase (95% confidence interval: 1.44-2.48) in odds for having symptoms. Conclusion: Compliance with the current occupational heat standard protects 4/5 of the workers, whereas noncompliance reduces this proportion to one half. The reasons for noncompliance include the gaps and ambiguities in the law. The law should specify work/rest schedules; outdoor work should be identified as an occupational heat hazard; and the staff should include occupational personnel to manage heat stress in establishments involving heat exposure.

일부 농업인의 고온노출에 대한 실태와 인지도 조사 (Status and Awareness of Excessive Heat Exposure among Agricultural Workers)

  • 이동현;김동섭;정진욱;이관;임현술
    • 농촌의학ㆍ지역보건
    • /
    • 제43권1호
    • /
    • pp.9-17
    • /
    • 2018
  • 농작업 시 고온에 대한 노출 실태를 파악하고, 고온 노출에 대한 인지도를 조사하여 농업인의 고온성질환 예방 방안을 모색하고자 이 연구를 시행하였다. 경주시 일부 농촌 마을을 농작업 중 고온노출 장소로 선정하였다. 여름 동안 총 9회의 환경 측정을 실시하였다. 측정을 통해 열지수와 WBGT를 산출하였고, 이들과 현재 우리나라 기상청에서 폭염 경보 및 주의보의 기준으로 제시하고 있는 일별 최고기온을 비교하였다. 설문조사는 같은 지역 농업인 90명을 대상으로 실시하였다. 설문조사는 일대일 면접조사로 진행되었으며, 설문조사서는 고온 노출 실태, 생활 행태, 병력, 온열질환에 대한 인지도 등에 관한 항목으로 구성하였다. 폭염경보 및 주의보 시 WBGT(Wet Bulb Glove Temperature index)와 열지수의 일치율은 높았으나, 비폭염주의보 시 WBGT가 초과되는 경우가 있었다. 조사대상자는 총 90명이었고, 연령별은 60대 이상이 78명(86.7%)이었다. 작업은 주로 새벽-오전(71.1%)에 하였으며, 하루 야외 작업시간은 4시간 미만(54.4%)이 가장 많았으나, 주기적 휴식을 하는 경우는 23.3%이었다. 온열질환 경험률은 14.4%이었고, 증상으로는 피곤, 무기력, 현기증, 두통, 땀 등의 순이었다. 전반적으로 온열질환 및 폭염주의보에 대한 인지도는 각각 70.0%, 74.4%로 높았다. 정책적으로 폭염주의보 발령 시에는 단순한 기온만 고려할 것이 아니라 WBGT기준과 열지수를 동시에 고려하여야 할 것이다. 농업인에게는 농작업 시 휴식 시간을 주기적, 양적으로 늘려 온열질환을 예방하도록 홍보 및 교육을 하여야 할 것이다.