• 제목/요약/키워드: well loss

검색결과 3,591건 처리시간 0.026초

Feedback Burst Loss Ratio Control for Link Performance Improvement in Optical Bur st Switching Networks

  • Linh, To Hoang;Yoon, Gwi-Ok;Nam, Jae-Hyun;Solongo, Ganbold;Hwang, Won-Joo
    • 한국멀티미디어학회논문지
    • /
    • 제16권9호
    • /
    • pp.1067-1076
    • /
    • 2013
  • Known as an important criterion that evaluates performance of future high-speed backbone networks, burst data loss ratio is well-studied in Optical Burst Switching networks. Current literatures mostly focus on reduce burst loss ratio without considering the system stability and link utilization after reducing. In this paper, we propose a novel framework which comes from feedback theoretic to dynamically control burst loss ratio in OBS. The proposed scheme tries to track the pre-set values of burst loss ratio and increases the stability and link utilization degree. The simulation results show that measured burst loss ratio always tracks setup reference with small errors, wavelength channel utilization is increased up to 2% and the system stability is also improved.

전류분포가 3본-도체의 교류손실 특성에 미치는 영향 (Influence of Current Distributions on AC Loss Characteristics in a 3-conductor)

  • 정재훈;류경우
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.206-209
    • /
    • 2003
  • AC loss is an important issue in the design of high-T$_{c}$ superconducting power cables which consist of a number of Bi-2223 tapes wound on a former. In the cables, the tapes have different critical currents intrinsically. And they are electrically connected to each other and current leads. These make loss measurements considerably complex, especially for short samples of laboratory size. So special cautions are required in the positioning of voltage leads for measuring the true loss voltage. In this work we have prepared a conductor composed of three Bi-2223 tapes with different critical currents. The ac loss characteristics in the conductor have experimentally investigated. The loss tests indicate that the ac loss is dependent on arrangements of voltage leads but not on their contact positions. The measured losses in the conductor also agree well with the sum of the transport losses measured in each Bi-2223 tape.e.

  • PDF

전류분포가 3본-도체의 교류손실 특성에 미치는 영향 (Influence of Current Distributions on AC Loss Characteristics in a 3-conductor)

  • 정재훈;류경우
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.7-10
    • /
    • 2003
  • AC loss is an important issue in the design of high-T$_{c}$ superconducting power cables which consist of a number of Bi-2223 tapes wound on a former. In the cables, the tapes have different critical currents intrinsically. And they are electrically connected to each other and current leads. These make loss measurements considerably complex, especially for short samples of laboratory size. So special cautions are required in the positioning of voltage leads for measuring the true loss voltage. In this work we have prepared a conductor composed of three Bi-2223 tapes with different critical currents. The ac loss characteristics in the conductor have experimentally investigated. The loss tests indicate that the ac loss is dependent on arrangements of voltage leads but not on their contact positions. The measured losses in the conductor also agree well with the sum of the transport losses measured in each Bi-2223 tape.e.

  • PDF

점성 손실모델 도입에 의한 축류 압축기 준 3차원 압축성 유동해석 (A Study on the Quasi-3-Dimensional Compressible Flow Calculation by Introduction of Viscous Loss Model in Axial-Flow Compressor)

  • 조강래;이진호;김주환
    • 대한기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.1044-1051
    • /
    • 1989
  • 본 연구에서는 Wu가 제시한 수학적 모델에 기초를 둔 비점성 준3차원 유동해 석에 실제 유체의 점성효과 및 2차유동 등에 의해 발생하는 손실들을 손실모델로 반영하여 그 타당성 유무를 검토하는 데 목적을 두었다.

Cross-Coupled Microstrip Combline Bandpass Filter Using Stepped-Impedance Resonators

  • Cho, Young-Ho;Choi, Seung-Un;Yun, Sang-Won
    • Journal of electromagnetic engineering and science
    • /
    • 제7권4호
    • /
    • pp.190-194
    • /
    • 2007
  • In this paper, a cross-coupled microstrip combline bandpass filter using stepped-impedance resonators(SIRs) is proposed. In order to improve the selectivity as well as the insertion loss, the SIR configuration is used. The cross coupling is also introduced to enhance the selectivity. The improvement of the insertion loss is demonstrated not only by deriving the quality factor of the SIR but through the measured performances. Both the proposed and the conventional combline bandpass filter with 5 % of fractional bandwidth at 2 GHz were fabricated and tested. Compared to the conventional combline bandpass filter, the proposed one exhibits the improved selectivity as well as the lower insertion loss characteristics.

A Study on Voltage Stability Improvement by the Efficient Network Reconfiguration Algorithm

  • Kim, Byung-Seop;Shin, Joong-Rin;Park, Jong-Bae;Shin, Yong-Hak
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권2호
    • /
    • pp.58-68
    • /
    • 2004
  • This paper presents an optimal routing algorithm (ORA) for maximizing voltage stability as well as for minimizing power loss in radial power systems. In the proposed ORA, a novel voltage stability index (VSI) for real-time assessment is newly introduced based on the conventional critical transmission path framework. In addition, the suggested algorithm can automatically detect the critical transmission paths resulting in voltage collapse when additional real or reactive loads are added. To implement an effective ORA, we have developed an improved branch exchange (IBE) method based on a loss calculation index and tie-branch power flow equations, which are suggested for real-time applications. The proposed algorithm has been tested with IEEE test systems as well as a large-scale power system in Korea to demonstrate its effectiveness and efficiency.

증기운 폭발의 위험성 평가를 위한 전문가 시스템의 구축 (Construction of Expert System for Hazard Assessment of Unconfined Vapor Cloud Explosion)

  • 함병호;손민일;김태옥;조지훈;이영순
    • 한국안전학회지
    • /
    • 제10권2호
    • /
    • pp.97-104
    • /
    • 1995
  • To evaluate readily the effect of unconfined vapor cloud explosion(UVCE) having high possibility of accident and risk in chemical industries, the expert system of UVCE was developed and its applicability on a real accident was analyzed. We found that the hazard of UVCE could be well evaluated from the TNT equivalency model and the empirical loss data produced by overpressure for chemical facilities. By using the developed expert system, the size of vapor cloud, the quantity of vaporization, the released energy, the overpressure range from explosion point, and the impact damage of each installation could be estimated respectively. Also, probable maximum loss and catastrophic loss potential for real accident( cyclohexane release in Flixborough Nypro company) were estimated and compared with damages of the accident. As a result, the developed expert system could be well applicable to real accident.

  • PDF

개인의 상실감이 디지털 컨텐츠 선호에 미치는 영향에 대한 탐색적 연구 (An Exploratory Study on the Effects of the Negative Emotions on the Selection of Digital Contents)

  • 오창규
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제19권4호
    • /
    • pp.253-270
    • /
    • 2010
  • The adjustment of negative emotions in later life is related to the quality of life and life satisfaction. any studies have examined how to control the negative emotions in related to physical, psychological, and social relationships. As the digital media and contents positively influence elder's mental and somatic well-being, it is significant to examine this problem from IT usage, especially the selection of digital contents. This study validated the theoretical study through a qualitative exploratory study comprising both negative emotions and the selection of digital contents, and empirically tested the proposed research model on the older people. The result shows the pattern of linkages between the grief of loss and the pursuit of digital contents. Loss from being parted by death and loss of relations was positively related to the information seeking contents. Economical loss and loss of physical functions was positively related to the innovation seeking contents. Loss of physical functions and Loss from being parted by death was positively related to the emotion seeking contents. And economic loss and loss of relations was positively related to the entertainment seeking contents.

The Association Between Occupational Exposure to Hand-Arm Vibration and Hearing Loss: A Systematic Literature Review

  • Weier, Michael H.
    • Safety and Health at Work
    • /
    • 제11권3호
    • /
    • pp.249-261
    • /
    • 2020
  • Background: Hearing loss is one of the most prevalent worker health conditions worldwide. Although the effect of noise exposure on hearing is well researched, other workplace exposures may account for significant hearing loss. The aim of this review was to determine whether occupational hand-arm vibration exposure through use of power or pneumatic tools, independent of noise exposure, is associated with permanent hearing loss. Do workers suffer from hand-arm vibratione-induced hearing loss? Methods: Peer-reviewed articles published in English between 1981 and 2020 were identified through five online databases with five search keywords. Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines, including online database search methodology, study selection, article exclusion, and assessment of potential study design confounders and biases, were followed. Results: Database searches retrieved 697 articles. Fifteen articles that reported 17 studies met the criteria for review. All but two studies revealed statistically significant associations between occupational exposure to hand-arm vibration and hearing loss. The majority of the study results revealed associations between hand-arm vibration and hearing loss, independent of potential age and noise confounders. Conclusion: Few studies have examined the association between occupational exposure to hand-arm vibration and hearing loss. Dose response data were limited as only one study measured vibration intensity and duration. Although the majority of studies identified statistically significant associations, causal relationships could not be determined. Further research using standardized and uniform measurement protocols is needed to confirm whether the association between occupational exposure to hand-arm vibration and permanent hearing loss is causal and the mechanism(s).

Millimeter-wave diffraction-loss model based on over-rooftop propagation measurements

  • Kim, Kyung-Won;Kim, Myung-Don;Lee, Juyul;Park, Jae-Joon;Yoon, Young Keun;Chong, Young Jun
    • ETRI Journal
    • /
    • 제42권6호
    • /
    • pp.827-836
    • /
    • 2020
  • Measuring the diffraction loss for high frequencies, long distances, and large diffraction angles is difficult because of the high path loss. Securing a well-controlled environment to avoid reflected waves also makes long-range diffraction measurements challenging. Thus, the prediction of diffraction loss at millimeter-wave frequency bands relies on theoretical models, such as the knife-edge diffraction (KED) and geometrical theory of diffraction (GTD) models; however, these models produce different diffraction losses even under the same environment. Our observations revealed that the KED model underestimated the diffraction loss in a large Fresnel-Kirchhoff diffraction parameter environment. We collected power-delay profiles when millimeter waves propagated over a building rooftop at millimeter-wave frequency bands and calculated the diffraction losses from the measurements while eliminating the multipath effects. Comparisons between the measurements and the KED and GTD diffraction-loss models are shown. Based on the measurements, an approximation model is also proposed that provides a simple method for calculating the diffraction loss using geometrical parameters.