• Title/Summary/Keyword: welding joint

Search Result 1,133, Processing Time 0.024 seconds

Cyclic Loading Tests of Concrete-Filled Composite Beam-Column Connections with Hybrid Moment Connections (복합모멘트접합을 갖는 콘크리트 충전 보-기둥 합성접합부의 반복하중 실험)

  • Lim, Jong Jin;Kim, Dong Gwan;Lee, Sang Hyun;Lee, Chang Nam;Eom, Tae Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.5
    • /
    • pp.345-354
    • /
    • 2016
  • In the present study, hybrid moment connections of welding and bar reinforcement for composite beam-column connections were proposed. Concrete-filled octagonal tube and U-section were used for the column and beam, respectively. In the beam-column connection, the top flange and web of the beam U-section were connected to the column plate by welding. However, to reduce stress concentration at the weld joints, the bottom flange of the beam was not welded to the column plate. Instead, to transfer the tension force of the beam flange, reinforcing bars passing through the column plate were used. Four exterior connections with conventional welded and hybrid moment connections were tested under cyclic loading and their cyclic behaviors were investigated. The test results showed that the hybrid moment connections successfully transferred the beam moment to the column. The strength and ductility of the hybrid moment connections were comparable to the conventional welded moment connection with exterior diaphragm; however, the connection performance was significantly affected by the details of the hybrid moment connection.

Comparative analysis on mechanical properties of gold and Co-Cr dental alloys due to joining methods (이종금속간의 결합방법에 따른 결합강도에 관한 비교 연구)

  • Park, Seong-Kyu;Choi, Boo-Byung;Kwon, Kung-Rock
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.75-86
    • /
    • 2003
  • The purpose of this study was to evaluate their mechanical properties after laser-welding or soldering of precious and non-precious dental alloys. For this study, 30 Co-Cr alloy specimens, 15 gold alloy specimens, 15 palladium alloy specimens were casted and seperated on the middle area. 15 sperated Co-Cr specimens and 15 seperated gold alloy specimens were laser welded (GW Group). 15 sperated Co-Cr specimens and 15 sperated gold alloy specimens were soldered by coventional soldering method (GS Group). 15 sperated Co-Cr specimens and 15 seperated palladium alloy specimens were laser welded (PW Group). 15 sperated Co-Cr specimens and 15 sperated palladium alloy specimens were soldered by coventional soldering method (PS Group). Tensile strength, 0.2% yield strength, % elongation were recorded in nine specimens of each group. Bending strength were record in six specimens of each group. These data for four groups were subjected to a two-way analysis of variance(ANOVA). The fracture locations, fractured surfaces were examined by SEM(scanning electron microscope). The results were as following: 1) In the same alloy combination, the tensile strength and 0.2% yield strength and of the laser welded group with same metal combination were significantly less than soldered groups(p<0.05). 2) In the combination of Co-Cr/Palladium, the bending strength of laser welded group were significantly less than that of soldered groups(p<0.05). In the combination of Co-Cr/Gold, the bending strength of laser welded group were significantly higher than that of soldered groups(p<0.05). 3) In the same method of joint, the tensile strength and 0.2% yield strength and bending strength of the Co-Cr/gold were significantly higher than Co-Cr/palladium(p<0.05). 4) There was no significantly statistical difference between each group in the % elongation(p>0.05). 5) The fracture of the laser welded specimens occured in the welding area and a large void was observed at the center of the fracture surface. 6) The fracture of the soldered specimens occured also inthe soldered area and many porpsities were showed at the fracture sites.

Study on microstructure and mechanical properties of friction stir welded duplex stainless steel (마찰교반접합된 이상 스테인리스강의 미세조직 및 기계적 특성에 관한 연구)

  • Choi, Don-Hyun;Ahn, Byung-Wook;Yeon, Yun-Mo;Song, Keun;Jung, Seung-Boo
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.24-24
    • /
    • 2010
  • 마찰교반접합법은 특정한 회전수로 회전하는 용접 툴을 이용하여 접합하고자 하는 피접합재의 맞댄면에 삽입시킨 후 툴을 이동시키거나 혹은 시편을 견고하게 고정시킨 장치(backing plate)가 움직여 고상 상태에서 접합이 이루어진다. 알루미늄, 마그네슘 등 비교적 융점이 낮은 저융점 재료의 재료에 처음 적용이 되어 많은 연구가 활발히 진행되었고 타 용접방법에 비해 우수한 접합특성을 나타내었다. 최근 이러한 마찰교반접합은 이러한 저융점 재료를 넘어서 스틸, 타이타늄, 니켈 등과 같은 고융점 재료 등에 대한 적용이 늘어나고 있다. 마찰교반접합을 이용하여 이러한 고융점 재료의 접합 경우 내마모성 및 내열성 등의 내구성이 갖추어진 툴과 이러한 툴을 냉각시킬 수 있는 냉각 장치 등이 필요로 하나 경제적 측면이나 접합부의 우수한 특성 등을 고려 할 때 그 적용 및 발전 가능성이 매우 높다고 볼 수 있다. 2상 스테인레스 강은 금속 조직적으로 페라이트와 오스테나이트 상이 거의 1:1의 동등한 비율로 매우 미세하게 결합된 구조를 가지고 있다. 또한 이상 스테인레스 강은 각상의 개개의 특성에 기인하여 염소 분위기에서 응력부식 저항성이 우수하고, 공식과 틈부식에 대한 저항성이 매우 뛰어나다. 그리고 이상 스테인레스 강은 비교적 고가인 Ni이 일반 오스테나이트 스테인리스 강의 약 1/2의 수준으로 적게 포함이 되어 경제적인 이점을 지니고 있으며 또한 용접성이 좋아 산업계의 수요는 현재 점차 증가하고 있는 상황이다. 하지만 이러한 이상 스테인리스 강은 용접 후 페라이트 상의 조대화, 그리고 페라이트 상의 분율이 오스테나이트 상의 분율보다 높아지게 되어 용접부에서의 저온 인성 감소 및 내식성 저하 등의 문제가 발생하게 된다. 그리하여 용접 시 이러한 문제점을 해결하기 위해서는 입열량의 조절이 가장 필요로 하는 것으로 알려져 있다. 본 연구에서는 마찰교반용접을 이용하여 두께 3mm의 대표적인 이상 스테인리스 강인 SAF2205 스테인리스 강에 대해 맞대기 마찰교반접합을 실시하였다. 툴 회전속도를 변수로 하여 접합을 실시하였으며 접합 시 툴은 $Si_3N_4$ 툴을 사용하였다. 접합 후 외관상태 점검, 미세조직 관찰, 경도 및 인장강도 측정 등의 실험을 실시하였고, 이러한 결과를 이용하여 미세조직과 기계적 특성과의 관련성을 조사하였다.

  • PDF

Effect of Process Parameters on Quality in Joint for Al/Steel Joining a MPW (전자기 펄스 용접을 이용한 Al/Steel 접합시 접합부 품질에 미치는 공정변수 영향)

  • Shim, Ji-Yeon;Kang, Bong-Yong;Kim, Ill-Soo;Park, Dong-Hwan;Kim, In-Ju;Lee, Kwang-Jin
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.27-27
    • /
    • 2009
  • 드라이브 샤프트는 일반적으로 엔진에서 발생된 회전력을 바퀴에 직접 전달하는 동시에 조향기능을 수행하는 자동차 부품이다. 최근에 경량화를 통한 에너지 절감을 위하여 기존 스틸소재를 알루미늄으로 대체하는 방안에 대한 연구가 집중되고 있다. 그러나 알루미늄 단일소재로 드라이브 샤프트를 제조하는 것은 비경제적이며 또한 기 개발된 자동차 부품들과의 연결을 고려하여 알루미늄 튜브와 스틸 요크의 이종금속 접합기술이 요구된다. 전자기 펄스용접은 전자기력을 이용하여 용접대상물을 고속으로 충돌시켜 용접하는 기술로서 열 발생이 적어 재료의 특성차로 인한 결함 및 변형이 발생하지 않아, 이종금속간 고품질 용접이 가능하며, 전자기 펄스 용접부의 품질과 밀접한 관계를 갖는 공정변수 경우 모재와 접합재의 재질 따라 적정 공정변수 범위가 변화되므로 공정에 따른 데이터의 축적은 대단히 중요하다. 전자기 펄스 용접을 이용한 이종금속 접합시 접합부 품질에 영향을 미치는 공정변수는 충전전압, 모재와 접합재 사이의 간격 및 접합재의 직경과 두께의 비(D/T비)로서 보고되었으며, Al/Steel 이종 금속 접합시 이들 공정변수가 접합부에 미치는 영향 및 최적의 공정변수 도출을 위한 연구는 시도되지 않았다. 따라서 본 연구는 전자기 펄스 용접기술을 이용한 Al/Steel 이종금속 접합 실험을 통하여 전자기 펄스용접의 적정성과 최적의 충전전압, 모재와 접합재 사이의 간격, D/T비를 도출하고자 한다. 전자기 펄스 용접 장치는 한국생산기술연구원과 웰메이트(주)에서 공동으로 개발한 $120{\mu}F$의 캐패시터 6개로 구성된 'W-MPW36'을 사용하였으며 이 장치의 최대충전전압과 최대접합용량은 각각 10kV, 36kJ이다. 접합재는 전기 전도율의 높은 Al 1070 파이프를 사용하였으며 모재는 기존 스틸 요크재인 SM45C 환봉을 사용하였다. 기보고된 연구를 통하여 코일과 접합재 사이의 간격이 좁을수록 높은 전자기력이 접합재에 작용하는 것을 확인하였으나 코일내 접합재와 모재 삽입 편의를 위하여 1mm로 설정하였다. 접합부의 품질 평가를 위하여 수압시험을 실시하였으며, 시험 후 접합부 단면을 주사전자현미경(SEM)을 이용하여 관찰하였다.

  • PDF

Fatigue Evaluation of a Steel Bridge in Service through Stress History Measurement and Consideration of Stress Category (공용중인 교량의 응력이력 계측 및 응력범주를 고려한 피로평가)

  • Na, Sung-Ok;Kwon, Min-Ho;Cha, Cheol-Jun;Kim, In-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.108-116
    • /
    • 2014
  • The proper stress history measurement should be conducted in order to examine the accurate cause of fatigue cracks or the fatigue safety in the steel bridge. Only one strain gauge is generally installed in the field for the stress history examination because of the field circumstances, economic feasibility, workability, and so on. However, this method may not consider the actual size of the specific structure, the gauge length, and the affect of stress concentration in the welded joint. In addition, it is difficult to apply for the stress analysis. Therefore, this study suggests improvements that are a great number of gauge installations, the gauge location adjustment, and the use of the minimum length gauge. It is drived the correlative equation of strain for the distance between the welding toe and the strain gauge installation, and compare correlative equation with equation of IIW. Also, this study could estimate the remaining life and fatigue damage of bridge in service by selecting the suitable stress category. In conclusion, it is possible to understand the member which is high in the fatigue cracks, and the quantitative relations between the welding toe and the strain gauge installation distances. The proposed approach in this study can make an more accurate fatigue damage and a remaining life prediction so that the improved method should be applied in measuring the strain of bridges from now on.

Selection of Postweld Heat Treatment Condition of a High-Temperature and High-Pressure Forged Valve (고온고압용 단조밸브의 용접후열처리 조건 선정)

  • Park, Jae-Seong;Heo, Ki-Moo;Yoon, Sung-Hoon;Moon, Yoon-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.10 no.2
    • /
    • pp.48-59
    • /
    • 2014
  • Coupons which have same figure as weld joint of the forged steel valves and 1 inch nominal weld thickness were manufactured using ASTM A182 F92 material. After welding with GTAW method, the welded specimens have been post-weld heat treated at $705^{\circ}C$, $735^{\circ}C$, $750^{\circ}C$, $765^{\circ}C$, $795^{\circ}C$ and $825^{\circ}C$ for 1 hour per 1 inch nominal weld thickness each (Group 1) to evaluate characteristics of welds based on various holding temperature. Indeed, 3 welded specimens were post-weld heat treated for 30 minutes, 1 hour and 2 hour (Group 2) at $735^{\circ}C$ to evaluate characteristics of welds based on various holding time. Hardness values were measured at the weld metal, heat affected zone and base metal to observe hardness change depending on the condition. As a result of the evaluation, appropriate holding temperature for PWHT is proved as $750^{\circ}C$ and $765^{\circ}C$ for 1hour per 1 inch nominal weld thickness. Indeed, holding for 1 hour per 1 inch nominal weld thickness was insufficient for PWHT effect when the holding temperature was at $735^{\circ}C$. The microstructure of post-weld heat treated weld metal was determined as tempered-martensite structure.

  • PDF

Experimental Study on the Behavior of Building Hardware with Joint Details (접합 방법에 따른 하지철물 구조물의 거동에 관한 실험적 연구)

  • Hong, Seonguk;Kim, Seunghun;Baek, Kiyoul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.190-198
    • /
    • 2018
  • In recent years, non-welded building hardware has been installed by bolt assembly is used. The non-welded building hardware method can reduce accidents caused by welding, and can be constructed by bolt assembly, which can reduce labor costs and shorten the construction period. However, there is a need for a method to compensate for the occurrence of buckling at the time of construction. The purpose of this study is to evaluate the behavior of joints between steel pipe and fastener and to evaluate the behavior of joints of non-welded and welded hardware frame. As a result, it was found that the foundation steel structure without welded joints was deformed to a rotation angle of member much larger than the allowable interlayer displacement angle 0.01 to 0.02 required according to the seismic load rating in the seismic load resistance system.

Study on the Physical Characteristics of Water Supply Steel Pipe according to Temperature Change (수도용 강관의 온도변화에 따른 물리적 특성에 대한 연구)

  • Kim, Woo-young;Jang, Am
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.733-740
    • /
    • 2017
  • 'The facilities standards of water supply' issued by the Ministry of Environment in 2004 indicates that expansion joints cannot be used in welding water supply steel pipes. However, their reason is not clear and it is difficult to confirm the stability of the steel pipe for a water supply pipeline. The purpose of this study is to determine whether or not an expansion joint is necessary to improve the stability of water supply in steel pipe through a displacement analysis of the pipework. The test results are as follows. Firstly, it was found that expansion and contraction of the water supply steel pipe (D 2,400 mm) occur repeatedly in 4 cycles per year, and the maximum expansion and contraction amount of the pipe is 13.03 mm in 1.24 km pipelines. Secondly, the thermal stress caused by expansion and contraction of the steel pipe is $13.7{\sim}36.1kgf/cm^2$ according to the burial depth (0~4 m). The main comparison factors to determine the stability of the steel pipe (STWW 400) were the allowable tensile strength and the fatigue limit, which were computed to be $4,100kgf/cm^2$ and $1,840kgf/cm^2$, respectively. Finally, the thermal stress of the steel pipe is very small compared to the allowable tensile stress and fatigue stress. Therefore, thermal stress does not affect the stability of the steel pipe, although the expansion and contraction of the steel pipe occurs by temperature changes. In conclusion, the study demonstrated that expansion joints are not required in water supply steel pipelines.

Topographical Landscapes and their Controlling Geological Factors in the Juwangsan National Park: Welding Facies and Columnar Joints (주왕산 국립공원의 지형경관과 지질학적 지배 요인: 용결상과 주상절리)

  • Hwang, Sang-Koo;Kim, Jae-Ho
    • The Journal of the Petrological Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.195-209
    • /
    • 2009
  • Juwangsan area($107.4km^2$) has been designated as the twelfth National Park in 1976, because it has magnificent aspect and seasonally spectacular landscapes. Juwang valley($9,177.5m^2$) has been designated as Noted Scenery No. 11 in 2003, because it has the same topographical landscape as rock domes, rock cliffs, caves, waterfalls and plunge pools. The most spectacular landscapes are exhibited in the densely welded zone of the Juwangsan Tuff. The rock cliffs generated from vertical joints in the densely welded zone, in which there are the same many rock cliffs as Geupsudae, Haksodae, Sinseondae, Mangwoldae, Giam and Byeongpungbawi, three caves such as Juwanggul, Mujanggul and Yeonhwagul in the cliff. The cliffs and caves are landscapes that were generated from vertical joints in the densely welded zone, and the rock domes and waterfalls are landscapes of erosional vertical joint planes in the zone. The vertical joints are columnar joints formed during cooling of the Juwangsan Tuff. Therefore the topographical features cause the cooling columnar joints that are vertically intersected in the densely welded zone of the Juwangsan Tuff.

A Study on the Repair of Fatigue Damage at Large Cast Iron structure using Cold Joint Method (냉간체결방법을 이용한 대형 주철 구조물의 피로손상수리방법에 대한 연구)

  • Lee, Sung-Riong;Lee, Dong Jun;Cho, Seok Swoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.140-148
    • /
    • 2019
  • Large cast iron structures are used in casings and pipes in shipsand chemical plants. Broken parts in the casings and pipescan result in failures even when stresses are below the yield strength of the part's materials. Fatigue failure of a large cast iron structure is inevitable due to the design constraints and low reliability of the material strength. A small structure can be repaired by welding, but a large structure cannot because it cannot be preheated slowly and uniformly. This study shows that a large structure can be repaired by a cold joint method using a crack repair screw. Large cast iron structures were manufactured by GC 300, and their design stress is below 3.5 MPa. The tensile strength on notched specimens repaired by crack repair screws was 8.2 MPa. Therefore, the safety factors of structures repaired by crack repair screws have a value above 2.3 and are considered to be high values.