Hysteretic behavior of dissipative welded fuses for earthquake resistant composite steel and concrete frames

  • Calado, Luis;Proenca, Jorge M.;Espinha, Miguel;Castiglioni, Carlo A.
    • Steel and Composite Structures
    • /
    • 제14권6호
    • /
    • pp.547-569
    • /
    • 2013
  • In recent years there has been increasing international interest about designing structures that cost less to repair after they have been subjected to strong earthquakes. Considering this interest, an innovative repairable fuse device has been developed for dissipative beam-to-column connections in moment-resisting composite steel and concrete frames. The seismic performance of the device was assessed through an extensive experimental program comprising ten cyclic and two monotonic tests. These tests were conducted on a single beam-to-column specimen with different fuse devices for each test. The devices varied in terms of the chosen geometric and mechanical parameters. The tests showed that the devices were able to concentrate plasticity and to dissipate large amounts of energy through non-linear behavior. Numerical models were developed with Abaqus and simplified design models are also proposed.

RBS 철골모멘트접합부의 내진거동평가를 위한 반복재하 실물대(實物大) 시험 (Cycllic Seismic Testing of Full-Scale RBS (Reduced Beam Section) Steel Moment Connections)

  • 이철호;전상우;김진호
    • 한국강구조학회 논문집
    • /
    • 제14권4호
    • /
    • pp.557-566
    • /
    • 2002
  • 본 논문은 4개의 철골모멘트 접합부에 대한 반복재하 실물대(實物大) 실험결과를 요약한 것이다. 주요 실험변수는 기둥과 보의 접합방식 (볼트접합 대 용접) 및 패널존의 강도 (강한 패널존 대 중간강도 패널존)이다. 중간 패널존 강도를 갖는 시험체는 패널존과 RBS 영역 모두에서 균형잡힌 방식으로 에너지가 소산되도록 고려하여 설계된 것으로 패널존 보강비용을 줄이고자 시도한 경우이다. 보웨브가 용접으로 접합된 경우의 시험체들은 특별연성모멘트골조에 요구되는 충분한 접합부 회전성능을 보여 주었지만, 웨브를 볼트로 접합한 시험체들은 스캘럽을 가로지르는 보플랜지의 조기 취성파괴로 인해 열등한 내진성능을 노출하였다. 보웨브를 볼트로 접합하면 비용을 줄일 수 있으나 원래 보단면의 전소성모멘트를 기둥에 전달하기 어려운 것으로 나타났다. 본 연구에서 적용된 것과 같이 양질의 용접시공에 의해 일단 그루브 용접부 자체의 취성파괴 문제가 해결되고 나면, 용접접근공내에 위한 보플랜지 모재의 파단이 다음의 문제로 대두됨을 알 수 있다. 용접접근공 내의 보 플랜지 파단문제를 역학적인 측면에서 이해하는데 도움이 되는 해석적 연구도 수행되었다.

RBS 철골모멘트접합부의 내진거동평가를 위한 반복재하 실물대 실험 (Cyclic Seismic Testing of Full-Scale RBS (Reduced Beam Section) Steel Moment Connections)

  • 이철호;전상우;김진호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.306-316
    • /
    • 2002
  • This paper summarizes the results of full-scale cyclic seismic testing on four RBS (reduced beam section) steel moment connections. Key test variables were web bolting vs. welding and strong vs. medium PZ (panel zone) strength. The specimen with medium PZ strength was specially designed to mobilize energy dissipation from both the PZ and RBS region in a balanced way; the aim was to reduce the requirement of expensive doubler plates. Both strong and medium PZ specimens with web-welding were able to provide sufficient connection rotation capacity required of special moment frames, whereas specimens with web-bolting showed inferior performance due to the premature brittle fracture of the beam flange across the weld access hole. In contrast to the case of web-welded specimens, the web-bolted specimens could not transfer the actual plastic moment of the original (or unreduced) beam section to the column. If a quality welding for the beam-to-column joint is made as in this study, the fracture-prone area tends to move into the beam flange base metal within the weld access hole. Analytical study was also conducted to understand the observed base metal fracture from the engineering mechanics point of view.

  • PDF

강재보와 합성기둥에 사용된 새로운 반강접 접합부의 설계 (Design of Innovative SMA PR Connections Between Steel Beams and Composite Columns)

  • 손홍민;;허종완
    • 복합신소재구조학회 논문집
    • /
    • 제5권1호
    • /
    • pp.28-36
    • /
    • 2014
  • This study describes the development of innovative connections between steel beams and concrete-filled tube columns that utilize a combination of low-carbon steel and super-elastic shape memory alloy components. The intent is to combine the recentering behavior provided by the shape memory alloys to reduce building damage and residual drift after a major earthquake with the excellent energy dissipation of the low-carbon steel. The analysis and design of structures requires that simple yet accurate models for the connection behavior be developed. The development of a simplified 2D spring connection model for cyclic loads from advanced 3D FE monotonic studies is described. The implementation of those models into non-linear frame analyses indicates hat the recentering systems will provide substantial benefits for smaller earthquakes and superior performance to all-welded moment frames for large earthquakes.

중력하중을 받는 SRC기둥-합성보 접합부 실험 (Test of SRC Column-to-Composite Beam Connection under Gravity Loading)

  • 김영주;배재훈;안태상;장성훈
    • 한국강구조학회 논문집
    • /
    • 제26권5호
    • /
    • pp.441-452
    • /
    • 2014
  • 본 논문에서는 중력하중을 받는 SRC기둥과 합성보 접합부의 정적실험을 수행하였다. 합성보는 H형단면과 U형단면으로 구성되어 있다. 모두 5개의 실대형 실험체를 설계하여 실험변수, 즉, H형단면 크기, 스터드커넥터의 유무, 스티프너와 상부근의 유무 등이 접합부의 거동에 미치는 영향을 조사하였다. 또한 H형단면과 U형단면의 용접접합부의 구조성능을 초기강성, 내력 및 변형능력을 중심으로 기술하였다.

2-Seam 냉간성형 각형 CFT 기둥-보 내다이아프램 접합부의 구조성능에 관한 연구 (Study on Structural Performance of Two Seam Cold-Formed Square CFT Column to Beam Connections with Internal Diaphragm)

  • 오헌근;김선희;최영환;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제3권4호
    • /
    • pp.27-37
    • /
    • 2012
  • The construction of a moment connection for a rectangular hollow section (RHS) column and a H-shaped beam is difficult because the RHS is a closed section. When a inner diaphragm is used for such a connection, in general, it is installed after cutting the HSS columns, which results in increased construction work. This paper suggests a new fabrication method to overcome such problems: An inner diaphragm is welded to inside a C-shaped section first, and then a column is fabricated by welding two C-shaped sections. This fabrication method is superior to a classic method in terms of constructibility. An experimental and a numerical study using Ansys 9.0 were performed in order to compare the strength of connections with respect to the presence of concrete, the corner shape of diaphragm, and the axis of loading. The experimental results including initial stiffness and ultimate loads are reported and the analytical results including load transfer mechanism, degree of stress concentration, and strain distribution are also reported.

2심 냉간성형 각형 CFT기둥-보 접합부의 구조거동 (Structural Behavior of Two-Seam Cold Formed Square CFT Column to Beam Connections)

  • 오헌근;김선희;박찬면;최성모
    • 한국공간구조학회논문집
    • /
    • 제12권4호
    • /
    • pp.81-90
    • /
    • 2012
  • The concrete-filled tube (CFT) column has the excellent structural performance. But it is difficult to connect with column and beam because of closed section. Its Solution, 2 members of ㄷchennel in which Internal diaphragm is installed were welded beforehand and the method of making Rectangular Steel Tube was proposed. According to upside and downside junction shape, Internal diaphragm suggested as symmetric specimen and asymmetric specimen. The upper and lower diaphragm of the Symmetric specimen used the same horizontal and The upper diaphragm of the Asymmetric specimen used the horizontal plate and the lower diaphragm used the vertically plate. In this research, 4 T-shape column to beam steps connections were tested with cyclic loading experiment in order to evaluate the structural capability of the offered connection. Symmetric specimens be a failure in 0.03rad from beam flange. And Asymmetric specimens be a failure in 0.05rad from column interface. The comparison results of All specimens shown similar to energy absorption capacity in 0.02rad.

Experimental investigation of thin steel plate shear walls with different infill-to-boundary frame connections

  • Vatansever, Cuneyt;Yardimci, Nesrin
    • Steel and Composite Structures
    • /
    • 제11권3호
    • /
    • pp.251-271
    • /
    • 2011
  • To make direct comparisons regarding the cyclic behavior of thin steel plate shear walls (TSPSWs) with different infill-to-boundary frame connections, two TSPSWs were tested under quasi-static conditions, one having the infill plate attached to the boundary frame members on all edges and the other having the infill plate connected only to the beams. Also, the bare frame that was used in the TSPSW specimens was tested to provide data for the calibration of numerical models. The connection of infill plates to surrounding frames was achieved through the use of self-drilling screws to fish plates that were welded to the frame members. The behavior of TSPSW specimens are compared and discussed with emphasis on the characteristics important in seismic response, including the initial stiffness, ultimate strength and deformation modes observed during the tests. It is shown that TSPSW specimens achieve significant ductility and energy dissipation while the ultimate failure mode resulted from infill plate fracture at the net section of the infill plate-to-boundary frame connection after substantial infill plate yielding. Experimental results are compared to monotonic pushover predictions from computer analysis using strip models and the models are found to be capable of approximating the monotonic behavior of the TSPSW specimens.

교량용 I형강 접합 절곡강합성 바닥판의 휨강성 분석 (Analysis For Effective Moment For Iinertia For Corrugated Steel-Concrete Composite Deck with I-beam Welded)

  • 손창두;박준명;한경봉;김준원;박선규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.209-212
    • /
    • 2008
  • I형강 접합 절곡 강합성 바닥판은 절곡 바닥판내에 I형강을 매입하여 기존의 현장타설 철근콘크리트바닥판보다 경량화되고 하중저항성능 및 시공성을 향상시킨 강합성 바닥판이다. 현재 일반적인 철근콘크리트 구조물의 유효휨강성에 대한 계산은 도로교설계기준 및 ACI에서 제안하고 있는 방법을 사용하고 있다. 본 논문에서는 도로교설계기준 및 ACI에서 제안된 유효휨강성에 대한 산정 방법과 CEB-FIP MC-90에서 제안하고 있는 방법을 사용해 I형강 접합절곡강합성 바닥판의 유효휨강성을 계산하고 그에 대한 적합성을 평가하였다. 또한 전단연결재의 유 무, 단면의 변화, 부재연결 그리고 일반철근콘크리트보와의 비교등 4가지 실험변수를 두고 총 5개의 실험체를 제작 실험하였고 실험결과와 이론식으로 산정된 휨강성값을 비교,평가하여 실험변수에 따른 휨강성의 변화를 분석하였다. 실험결과 CEB-FIP MC-90에서 제안하고 있는 방법이 ACI에서 제안하고 있는 방법보다 만족스러운 결과를 나타냈으며, 전단연결재가 있고 콘크리트와 바닥판의 부착면적이 많은 경우에 하중저항 성능과 휨강성이 높게 나타났다.

  • PDF

무용접 좌굴방지재로 보강한 철골 가새의 구조거동 (Structural Behavior of Steel Brace Strengthened with Non-welded Buckling Restraint Casing)

  • 김선희;문지영;최성모
    • 한국강구조학회 논문집
    • /
    • 제27권2호
    • /
    • pp.207-217
    • /
    • 2015
  • 철골 중심 가새골조는 최소의 물량으로 건물의 횡력에 대한 저항력을 확보할 수 있는 매우 효과적인 시스템이다. 그러나 중심가새 골조는 탄성거동을 전제로 풍하중에 대한 구조시스템으로 비탄성거동을 수반하는 지진하중에 대해서는 가새 좌굴 이후의 에너지 소산능력저하와 반복하중 하에 가새 및 접합부의 취성파단 가능성이 제기된다. 그로 인해 가새의 좌굴이 최초로 발생한 층에 소성변형이 집중되어 연약층 발생에 의한 건물의 붕괴로 이어질 가능성이 높다. 따라서 본 논문에서는 기 설치된 H형 가새를 무용접 냉간성형보강재로 보강하여 휨-좌굴을 억제하고 인장력과 압축력에 동일한 강도를 확보하는 보강안에 대한 연구를 진행하였다.