A Study on Portable Weighing Scales Applicable to Poultry Farms (가금류 농장에 적용 가능한 이동식 중량 저울에 관한 연구)

  • Park, Sung Jin;Park, In Ji;Kim, Jin Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.2
    • /
    • pp.155-159
    • /
    • 2022
  • Smart livestock, which combines information and communication technology (ICT) with livestock, can be said to be an effective solution to existing livestock problems such as productivity improvement, odors, and diseases. So far, it has hardly been universalized; thus, it is necessary to develop automation devices to reduce labor by localizing automation devices to expand the distribution of ICT technology to farms, and to advance precise specifications and health management technology using biometric information. Weighing scales currently being used in livestock farms are to prevent the spread of diseases by diagnosis and preparation for AI and other diseases in advance, using information on the growing weight of duck breeding. However, accurate values cannot be obtained due to poor breeding conditions. In this paper, we developed a separate data transmission system kit for the weighing scale and placed the sensor on top of the weighing scale so that the sensor wire is not affected by pollutants or ducks on the floor. A display function was provided, and a method of receiving and analyzing the serial port data of the weighing device, and then transmitting them to the data collection server was implemented.

Comparison of Egg Testing Devices for Internal Egg Quality Measurements (계란 할란검사장비의 성능 비교)

  • Kim, Dong Jun;Jeon, Seung Yob;Kim, Hee Won;Won, Jea Sun;Lee, Jae Cheong;Lee, Kyung-Woo
    • Korean Journal of Poultry Science
    • /
    • v.43 no.4
    • /
    • pp.229-233
    • /
    • 2016
  • This study was conducted to compare three commercially available egg testing devices for measuring egg quality. The devices used were a Laser-type (automatic), a Ultrasonic-type (automatic), and a Probe-type (manual). Fresh eggs weighing 60~68 grams were obtained from a commercial hen farm. Three trials were conducted. In Trial 1, a total of 50 eggs were successively analyzed by the three egg testing devices. In Trial 2, fresh eggs were successively analyzed by a combination of two egg testing devices. In Trial 3, a total of 600 eggs (weighing 60~68 grams) laid by same flock were selected, further divided into three sub-groups with a total of 200 eggs, and analyzed by an egg testing device. In Trials 1 and 2, no apparent difference was observed in egg weight between egg testing devices. However, albumin height was scored highest in the Ultrasonic-type egg tester followed by the Probe-type and Laser-type (Trials 1 and 2). Consequently, the Haugh unit was similarly altered. Yolk color was highest in the Laser-type egg tester followed by the Ultrasonic-type and Probe-type (Trials 1 and 2). When fresh eggs laid by a single flock were independently analyzed by three devices, egg weight did not differ, but albumin height and Haugh unit were higher (p<0.05) in the Ultrasonic-type egg tester than in the Probe-type or Laser-type testers. However, Laser-type testers produced higher (p<0.05) yolk color values than the Ultrasonic-type or Probe-type egg testers. In conclusion, the commercially available egg testing devices exhibited performance differences in measuring egg qualities, which warrants further consideration as to whether the magnitude of bias and precision between the devices could be acceptable in the egg grading system, especially when assessing eggs stored for certain durations.

Elderly Needs Assessment for ICT-based Elderly House Remodeling by applying Kinetic Principle (키네틱 원리를 적용한 ICT 기반 고령친화 주거 리모델링 요구조사)

  • Lee, Jin-Kyoung;Moon, Jung-In
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.7
    • /
    • pp.25-32
    • /
    • 2019
  • The purpose of the study is to survey the needs of the elderly for ICT-based Elderly Home Remodeling by Applying Kinetic Principle. This is conducted for elderly people over 60 years old living in Seoul and Gangreung district. The study is performed by the following approaches: First, This study is based on 'the Elements of Planning for ICT-based elderly Home Remodeling by applying Kinetic Principle'(Lee 2018). Second, the needs survey for house remodeling was conducted for elderly. Finally, To analyze the required characteristics of the elderly for remodeling by using SPSS statistics 25 analysis program. The conclusion of this study is as follows. Priority elements for house remodeling should be provided to ensure the safety of the elderly through emergency call buttons, glucometer, pressure-measuring gauge, weighing instruments, and warning devices. Kinetic principles should be applied to make minimal structural changes, as easy as possible remodeling, and devices should be designed to be easy to operate.

Suftla Flexible Active-Matrix Electrophoretic Displays

  • Miyasaka, Mitsutoshi;Nebashi, Satoshi;Shimoda, Tatsuya
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.466-469
    • /
    • 2006
  • We have developed the world's thinnest flexible electrophoretic displays (EPDs). The thin-film displays are 95 ..m thick, which is nearly the same thickness as a standard sheet of paper. Weighing 0.44g including external connection cables, these displays are also probably the world's lightest. We have also developed 7.1-inch-diagonal(paperback-sized) high-resolution flexible EPDs. The displays are large enough to be used as practical e-paper. More than 7 million transistors work correctly on plastic, enabling us to see 3-megapixel images. These flexible displays include active-matrix TFT devices that are fabricated using Suftla transfer technology. Suftla technology demonstrates the potential to achieve thin, flexible displays that will be used as an e-paper in the near future.

  • PDF

The Design of Hydraulic Brake Control System used on Blending Brake Function (혼합제동기능을 이용한 유압제동 제어시스템 설계)

  • Lee, Woo-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1809-1812
    • /
    • 2013
  • The bogie of monorail vehicles applies rubber wheel system not steel wheel system. In addition, The structure of the bogie is very complicated because vehicle operates on the elevated road and vehicle drives with wrapping the guide way. When the monorail vehicle applies air brake system, lower device of vehicle may be complex and some devices may be limited. On the other hand, hydraulic brake equipment is compact and not weighing. Braking force is also outstanding compared with air brake so the hydraulic brake equipment is suitable for monorail vehicle. Also urban transit system such as monorail, applies mixed system both friction brake and electric brake in order to save electric energy. But application case of hydraulic brake in the country is very rare because hydraulic brake have difficulty in satisfaction of control requirement and maintenance. Therefore, this study suggests ways to design hydraulic brake system with blending brake for monorail vehicle and applies the ways to future monorail.

Resource-Efficient Object Detector for Low-Power Devices (저전력 장치를 위한 자원 효율적 객체 검출기)

  • Akshay Kumar Sharma;Kyung Ki Kim
    • Transactions on Semiconductor Engineering
    • /
    • v.2 no.1
    • /
    • pp.17-20
    • /
    • 2024
  • This paper presents a novel lightweight object detection model tailored for low-powered edge devices, addressing the limitations of traditional resource-intensive computer vision models. Our proposed detector, inspired by the Single Shot Detector (SSD), employs a compact yet robust network design. Crucially, it integrates an 'enhancer block' that significantly boosts its efficiency in detecting smaller objects. The model comprises two primary components: the Light_Block for efficient feature extraction using Depth-wise and Pointwise Convolution layers, and the Enhancer_Block for enhanced detection of tiny objects. Trained from scratch on the Udacity Annotated Dataset with image dimensions of 300x480, our model eschews the need for pre-trained classification weights. Weighing only 5.5MB with approximately 0.43M parameters, our detector achieved a mean average precision (mAP) of 27.7% and processed at 140 FPS, outperforming conventional models in both precision and efficiency. This research underscores the potential of lightweight designs in advancing object detection for edge devices without compromising accuracy.

EFFECT ON THE OSTEOGENESIS OF DENTAL IMPLANTS AFTER HORIZONTAL DISTRACTION OSTEOGENESIS WITH NITRIFIED DISTRACTOR (질화 표면처리된 신장기를 이용한 수평적 치조골신장술 후 임플란트 식립시 골유착 효과에 관한 연구)

  • Park, Chul-Min;Kim, Su-Gwan;Kim, Hak-Kyun;Moon, Seong-Yong;Oh, Ji-Su;Baik, Sung-Mun;Lim, Sung-Chul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.3
    • /
    • pp.225-231
    • /
    • 2008
  • This study evaluated whether there is a difference between a conventional titanium distraction device and a TiN-coated device in terms of implant osseointegration after horizontal distraction osteogenesis in narrow alveolar bone. Four adult mongrel dogs, each weighing $9{\sim}10kg$, were used in this study. The lower premolars were extracted and horizontal distraction was performed with conventional titanium distraction devices (group 1) or TiN-coated devices (group 2). After an 8-week consolidation period, the implants were installed, and the dogs were sacrificed after another 8 weeks. The osseointegration around the implants was evaluated histomorphologically. There was one failure in experimental group 1 because of fracture of the device. Direct bone contact was achieved and there were no significant differences between the control group and experimental groups 1 and 2 in terms of osseointegration around the implants at 8 weeks. In summary, intraoral distraction osteogenesis is a good option for augmenting severely atrophied alveolar ridges, and the TiN-coated device may be useful because of its advantages, which include surface hardness, corrosion resistance, and reduced bacteria.

Complexity Analysis for Implementation of the ISO/IEEE 11073 PHD Standards (ISO/IEEE 11073 PHD 표준 구현을 통한 복잡도 분석)

  • Kim, Sang-Kon;Yoo, Done-Sik;Kim, Tae-Kon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.307-312
    • /
    • 2012
  • In this paper, we perform a complexity analysis for implementation of the ISO/IEEE 11073 Personal Health Device (PHD) standards in order to check the required system resources when ISO/IEEE 11073 PHD standards are implemented on the embedded system. Base on the implemented programs complying the PHD standards for a weighing scale, a blood pressure monitor, and a glucose meter among the various personal health devices, we make a pseudo-code. And then from the two different points of view such as program memory space and data memory space, we make a complexity analysis model. Because system resources or capability are strongly restricted in the personal health devices, our research work is very useful to estimate the required system resources.

Present Status and Analysis for IEEE 11073 Personal Health Device Specializations (IEEE 11073 개인건강기기별 표준 현황 및 분석)

  • Park, Han-Na;Kim, Seung-Hwan;Yoo, Done-Sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6C
    • /
    • pp.469-475
    • /
    • 2012
  • Increasing interest of life expectancy and health has made the u-health industry activating and the several international standard developing organizations(SDO) are dealing with u-health services and technologies. Among them, IEEE 11073 PHD(Personal Health Devices) Work Group is developing standards of personal health device communication for interoperability. There are many studies for introducing SDOs and analyzing the IEEE 11073-20601 standard. However, due to the rare study of PHD standards analysis, there are a lot of difficulties to utilize the standards. In this paper, present status of national and international SDOs including IEEE 11073 standards for PHD will be introduced. Moreover, device specialization standards such as thermometer, weighing scale, glucose meter, blood pressure monitor, electrocardiograph (ECG) etc.. will be analyzed based on the IEEE 11073-20601.

Development of Onboard Scales to Measure the Weight of Trucks (상용차량의 하중을 측정하기 위한 탑재형 자중계 개발)

  • Seo, Myoung Kook;Shin, Hee Yong;Lee, Ho Yeon;Ko, Jea Il;Tumenjargal, Enkhbaatar
    • Journal of Drive and Control
    • /
    • v.18 no.1
    • /
    • pp.9-16
    • /
    • 2021
  • Overloaded vehicles increase the maintenance cost of road structures, and they are a major factor in causing damage to the roads and bridges. In addition, overloaded vehicles compromise the braking capability of the vehicle; thus, threatening the safety of the driver. In order to prevent overloading of vehicles, the government is cracking down on the roads by using a device that measures the weight of vehicles. But this process is inconvenient because the place where the equipment is installed is far away from where the cargo is loaded. Due to the limitations of these fixed weighing devices, there is a growing need for technology that can monitor vehicle weight distribution and overload conditions in real time. In this work, we develop an onboard scale that can measure the load (weight) of trucks in real time. The onboard scale consists of high sensors, a signal processing unit, and a display, and it measures the load using height-displacement of the vehicle's leaf spring suspension.