• Title/Summary/Keyword: wearing time

Search Result 584, Processing Time 0.028 seconds

A Study on the Wearing Method and Origin of Magoja (마고자의 착용법 및 기원에 관한 연구)

  • 홍나영
    • Journal of the Korean Home Economics Association
    • /
    • v.41 no.5
    • /
    • pp.193-203
    • /
    • 2003
  • Magoja is a jacket for men and women. Magoja was worn between the jacket, jogori and the coat durumagi; that is over the jacket and under the coat. In the 19th century, Daewon-kun, who was wearing maqua, was in China and he came back to Korea. So, it was believed that the origin of magoja was from maqua from Qing. But, there were differences between magoja and maqua in their design. Therefore, I researched the origin of magoja and tried to know the design and the method of wearing magoja in the Chosun dynasty. The results are as follows. The design of magoja, especially its collar, was different from Chinese maqua. As analyzed above, it is difficult to regard the origin of magoja as deriving from Daewon-kun's maqua, which he wore when he went to Qing. Magoja-style jacket can be found from many old pictures. The collar of those jacket, whose style was waonsam-git unlike the present-day magoja, is consistent with the collar of sagyusam or baeja. And this kind of git style had existed for a long period of time as already studied in bangryungbangbi. Furthermore, the origin of this kind of jacket dated back to the maeksu of the Sung Dynasty; maek meaning Koguryo, maeksu was understood to indicate the style of the Koguryo jacket of short sleeves for the convenience of horseback riding. Maeksu, which varied in its kind and style, had been used as the equestrian clothes in China and was assumed to be particularly put on widely during the Yuan and Sung Dynasties. Maeksu continued to exist as daegeumeui during the Ming Dynasty but, later called magua, it was worn more widely ding the Qing Dynasty of the Manchus. This kind of maeksu or magua was the jacket which could be put on the coat and this style of wearing it during the Chosun Dynasty could be confirmed by the pictures. Therefore, magoja is not the jacket which was all of sudden derived from Qing's magua but one of traditional Korean clothes of the northern provinces which had existed for a long period of time. And magoja seemed to be put on more widely during the latter part of the Chosun Dynasty because of the influence of Qing's magua.

A Study on the Clothing Inconvenience Levels for the Clothing Improvement of Female Arthritis Patients (여성관절염질환자의 의복개선을 위한 의복불편정도에 관한 연구)

  • Han, Seung-Hee
    • Journal of Fashion Business
    • /
    • v.12 no.5
    • /
    • pp.111-125
    • /
    • 2008
  • The purpose of this study is in the investigation to relieve into the clothing inconvenience levels and to need by arthritis patients who experience clothing difficulties in daily living even without showing conspicuous physical disabilities. For this study, personal interviews were carried out with 151 female arthritis patients, using a questionnaire form consisting of a total of 206 items. Data analysis were done with spss 12.0 for the frequency analysis, cross tab analysis, t-test, and ANOVA. The findings are as follows. 1. The survey subjects were diverse in their age from 20s to 60s and 18.5% of them have need of other's assistance at the time of getting dressed or undressed of clothing. The knee part was felt to be the most uncomfortable, causing the inconveniences in wearing pants or panties. 2. The investigation into the inconvenience levels at the time of dressing or undressing of clothing was indicated that the wearing of pants was the hardest movement to arthritis patients, as the items relating to the movements for putting feet into or pulling them out of pants and those for raising pants over the hip were also accompanied by the feeling of pains. In addition, the aged arthritis patients felt the clothes-wearing movements more difficult. 3. The survey on the kind and inconvenience levels for the clothes currently being worn showed the highest wearing ratio for the pants, which were pointed out to be the most inconvenient. 4. As for the clothing improvement, the needs were located as a whole in the sufficiency in measures of pants crotch and circumference items, the flexibility in materials, the short length of pants, or the front clearance.

Is the retroauricular region a suitable donor site for full-thickness skin grafting in the era of mask wearing?

  • Yoon Soo Kim;Jeong Jin Park;Hyung Suk Yi;Jin Hyung Park;Hong Il Kim
    • Archives of Craniofacial Surgery
    • /
    • v.24 no.2
    • /
    • pp.66-72
    • /
    • 2023
  • Background: During the coronavirus disease 2019 (COVID-19) pandemic, the everyday use of face masks massively increased to prevent the spread of infection. Many people complain of ear pain and erosion when wearing a mask for extended periods of time. If prolonged mask usage is uncomfortable for ordinary people, a question arises-how much more inconvenient must mask wearing be for patients with a full-thickness skin graft (FTSG) donor site in the retroauricular region? Herein, we evaluated complications related to face mask use in 27 patients with a retroauricular FTSG donor site, with the goal of clarifying whether the retroauricular region is still an appropriate FTSG donor site in the context of the COVID-19 pandemic. Methods: Complications in 27 patients treated by FTSGs harvested from the retroauricular region from 2019 to 2021 were investigated. A questionnaire comparing the normal and the operated sides was administered. Pain, itching, soreness, deformity, and symmetry were further investigated. Results: Pain and itching were the only observed complications. The operated side was slightly more painful than the normal side in four patients (14.8%), and four patients (14.8%) reported itching on the operated side. However, all patients who experienced complications stated that the pain or itching did not interfere with mask wearing. Most symptomatic patients were older than 60 years of age (23.8%, p= 0.185) and wore masks for longer periods of time (28.5%, p= 0.326). Conclusion: Few retroauricular donor site-related complications occurred, and none of these complications caused inconvenience in daily life. Therefore, in the COVID-19 pandemic, the use of the retroauricular region as an FTSG donor site remains appropriate.

Presbyopic Spectacle and Monovision for Reading Performance Before Adaptation (노안안경과 모노비젼 콘택트렌즈 착용 후 적응 전 읽기 능력 평가)

  • Chu, Byoung Sun;Hwang, Jeong Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.263-268
    • /
    • 2010
  • Purpose: Eye movements and fixation ability are an important procedure to obtain external information and essential means of clear vision. The purpose of this study was to determine the reading performance such as reading time and number of fixations when random text was viewed at varying distances. Methods: Twenty two presbyopes were participated. All subjects were screened for their suitability to participate in the study by clinical examination, and none of the participants had previously worn contact lenses and no previous experience of wearing any types of presbyopic vision correction except single vision. The reading time and number of fixations were recorded using eye tracker while each subjects was waring four vision corrections which included single vision for distance (SV), bifocal spectacle lenses (BIF), progressive addition lenses (PAL), and monovision (MV). The reading material was presented at distance and near distance. Results: Reading time and number of fixations for near stimulus were significantly different among vision correction used in this study (p<0.001). In particular, wearing SV required longer reading time and produced longer fixation duration for near text. However, reading distance text was similarity performed across vision corrections tested and there was no statistical difference found for either reading time and number of fixations. Conclusions: Wearing presbyopic vision correction is advantageous for reading task of near stimuli, but not having near correction such as wearing SV could result in longer reading time and higher number of fixation due to lacks of accommodative ability for near task. For the future studies, it would be interesting to examine the performance of reading both at adapted and unadapted stages as examining only unadapted wearers was limitation of this study.

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.

The Effect of Circle Lens and Soft Contact Lens with Identical Material in Clinical Application on the Eyes (써클 및 동일 재질 콘택트렌즈의 임상 적용시 눈에 미치는 영향)

  • Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.147-157
    • /
    • 2011
  • Purpose: The present study was conducted to investigate the actual condition of circle lens wear and the differences caused by the pigmentation in blinking rate, non-invasive tear break-up time (NIBUT), and lens surface between circle and soft contact lens wear during clinical application. Methods: Eighty subjects were surveyed to know the actual condition of wearing circle lens. Blink rate, NIBUT of 20 subjects in twenties were measured after separately wearing soft contact lens and circle lens for 5 days. Their lens surfaces were also observed by scanning electron microscope. Results: Fifty percent of circle lens wearers answered that major reason for changing circle lens was discomfort and 67% of answerers wore circle lens more than 6 hours a day. The tendency of increased blink rates in both wearers of circle and soft contact lens at 30 minutes later when tear film stabilized and 3 hour after lens wearing was shown on the 1st, 3rd and 5th day with expanding wearing time. Especially at 3 hours after lens wearing on the 3rd and 5th day, the difference of blink rates was statistically different in circle lens wear and soft contact lens wear. The NIBUTs of soft contact lens wearers and circle lens wearers were 6.0 and 3.7 secs, respectively, at 30 min later on 1st day and were significantly different. NIBUTs of soft contact lens wearers and circle lens wearers were also statistically different 3 hrs after lens wearing on the 1st day and the similar pattern of NIBUTs was shown on the 3rd and 5th day. The roughness of both surfaces in soft contact lens and front surface in circle lens was same. However, pigmented front surface of circle lens was rougher and uneven. Conclusions: As the results, the circle lens wearers might feel discomfort in clinical application since the difference in lens surface of circle lens would change lens wettability during wearing. The difference by tinting contact lens was shown from the result, which could help better wearing circle lens.

Effects of 3D Compression Pants and Kinesio Taping on Isokinetic Muscular Function of Leg During Knee Joint Flexion Motion (3D 밀착형 팬츠와 키네시오 테이핑이 무릎관절의 등속성 굴곡 운동 시 하지의 근기능에 미치는 영향)

  • Choi, Jiyoung;Park, Heegeun;Lee, Wanglok;Hong, Kyunghi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.2
    • /
    • pp.240-257
    • /
    • 2016
  • This study determines the effect of 3D compression pants and Kinesio taping on muscular function of the leg during knee joint flexion and extension. Eight males participated in the experiment, wearing basic pants (BP), Kinesio taping on bare skin (KT), 3D compression pants with (KTP) and without Kinesio taping (CP). The test protocol for isokinetic muscular function was composed of four sets at three angular velocities (60, 180, $240^{\circ}/sec$) using Cybex 660. Peak torque and work per repetition of the lower limbs of eight males were analyzed from the result of Cybex. Agility and power of the subjects were examined from side step and sergeant jump. Peak torque, average power, work per repetition, force decay time of subjects wearing CP and KTP were significantly better than BP or KT, especially at low angular velocity of $60^{\circ}/sec$. The time to generate peak torque of subjects wearing BP was the longest, while the force-decay time of BP was the shortest. The application of Kinesio tape on skin did not increase muscle peak torque, work and power, but did shorten the time to generate peak torque.

Outcome Analysis of Cranial Molding Therapy in Nonsynostotic Plagiocephaly

  • Yoo, Han-Su;Rah, Dong Kyun;Kim, Yong Oock
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.338-344
    • /
    • 2012
  • Background It is known that nonsynostotic plagiocephaly does not spontaneously improve, and the craniofacial deformities that result from it. This study was conducted to analyze the effectiveness of helmet therapy for the nonsynostotic plagiocephaly patient, and to suggest a new treatment strategy based on this analysis. Methods A total of 108 pediatric patients who had undergone helmet therapy after being diagnosed with nonsynostotic plagiocephaly were included in this study. The patients were classified according to the initiation age of the helmet therapy, severity, and helmet wearing time. The treatment effect was compared using cranial vault asymmetry (CVA) and the cranial vault asymmetry index (CVAI), which were obtained from diagonal measurements before and after therapy. Results The discrepancy of CVA and CVAI of all the patients significantly decreased after helmet therapy. According to the initiation time of helmet therapy, the treatment effect was best at 5 months old or less. The helmet wearing time per day was proportional to the treatment effect up to 20 hours. In addition, the rate of the successful treatment (final CVA ${\leq}$ 5 mm) significantly decreased when the initiation age was 9.1 months or older and the treatment period was less than 7.83 months. Conclusions This study showed the effectiveness of the helmet therapy for nonsynostotic plagiocephaly patients. Based on analysis of this study, helmet therapy should be started at the age of 9 months or younger for 7.83 months or more, and the helmet wearing time should be more than 20 hours a day.

Clothing Pressure Evaluation of Girdle and Waist Nipper and Related Wearing Conditions (거들 및 웨이스트니퍼 착용에 의한 의복압 평가 및 관련된 착용변인)

  • Lee, Heeran;Hong, Kyunghi;Kim, Yang Weon;Park, Se Jin
    • Science of Emotion and Sensibility
    • /
    • v.16 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • The purpose of this paper is to investigate the adequate clothing pressure of upper and lower body foundation garment and subjective assessment of those compressive foundation depending on various wearing conditions. Eighteen women in their 30s and 40s participated in the experiments for this study to evaluate the level of clothing pressure of girdle and waist nipper. Subjects were divided into two groups by the wearing habits of foundation, one is the group of wearing foundation garment 'tightly' and the other is 'loosely', It was found that the group wearing foundation garment 'loosely' was much more sensitive than the group of 'tightly' in everyday life. The adequate pressure of upper foundation, waist nipper was about $1.5{\pm}0.8$ kPa which is lower than that of the lower body foundation, girdle. And at the same time, the sensitivity of the pressure level was higher when subjects are wearing waist nipper compared with wearing girdle. Therefore, precise pattern making process is necessary to meet the adequate level of pressure of the upper body foundation such as waist nipper, specially for those who used to wear clothing loosely.

  • PDF

The Effects of Interrelationship after Wearing between Respirators and Glasses Simultaneously (안면부 여과식 방진 마스크와 안경 동시 착용 시 상호 영향)

  • Eoh, Won Souk;Shin, Chang Sub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.47-53
    • /
    • 2018
  • This study compares the interrelation of fit factor(FF) and visual acuity test by the order of wearing preference between Particulate filtering face piece respirators(PFFR) and glasses for 54 participants. Glasses fitting factors is Optical Center Height(OH), Vertex Distance(VD) and Pantoscopic Angle(PA) or Visual acuity. We measured those factors and expressed by the ratio of standard point and change point. Quantitative fit factor was measured by Portacount Pro+ 8038 and compared the result of preference of wearing order between respirators and glasses. Also, we selected to 6 exercises among 8 exercises OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The pass/ fail criterion of FF was set at 100. Visual acuity test chart is developed by Chunsuk Han was used, Descriptive statistics was performed. Descriptive statistics(SAS ver 9.2), it is used geometric means, Wilcoxon analysis, peason correlation(P=0.05) Fit factor was increased when the respirator was worn before wearing the glasses(p=0.000) and decreased for visual acuity(p=0.000) The negative correlation was showed between OH and Overall fit factor(r=-0.409, p=0.002). Among 54 participants, 11 participants(20.3%) were worn respirator before wearing glasses and 1 participant(1.9%) was worn glasses before wearing respirator. The overall fit test showed the higher level was investigated for the group of participants wearing respirator before wearing glasses in 6 exercises. Also, overall fit factor were increased when participants wore glasses prior to respirator(16.6) to respirator prior to glasses(36.6). Visual acuity were increased when participants wore respirator prior to glasses(93.8) to glasses prior to respirator(106.0). Finally, comparison result of overall fit factor and visual acuity were glasses first choice from mask first choice. The results showed that higher overall fit factor was investigate when the participants wore the respirator prior to glassess at all. The results implied that it is important to maintain the overall fit factor and visual acuity according to the consideration of OH for glasses fitting when worker wore respirator and glasses at the same time.