• Title/Summary/Keyword: wavelength shift

Search Result 301, Processing Time 0.032 seconds

Thickness and Angle Dependent Microcavity Properties in Top-Emission Organic Light-Emitting Diodes (상부 발광 유기 발광 소자에서 두께와 시야각에 따른 마이크로 캐비티 특성)

  • Lee, Won-Jae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.32-35
    • /
    • 2011
  • Top-emission device has a merit of high aperture ratio and narrow emission spectrum compared to that of bottom-emission one. Emission spectra of top-emission organic light-emitting diodes depending on a layer thickness and view angle were analyzed using a theory of microcavity. Device structure was manufactured to be Al (100 nm)/TPD/$Alq_3$/LiF (0.5 nm)/Al (2 nm)/Ag (30 nm). N,N'-diphenyl-N,N'- di (m-tolyl)-benzidine (TPD) and tris (8-hydroxyquinoline) aluminium (Alq3) were used as a hole-transport layer and emission layer, respectively. And a thickness of TPD and Alq3 layer was varied in a range of 40 nm~70 nm and 60 nm~110 nm, respectively. Angle-dependent emission spectrum out of the device was measured with a device fixed on a rotating plate. Since the top-emission device has a property of microcavity, it was observed that the emission spectrum shift to a longer wavelength region as the organic layer thickness increases, and to a shorter wavelength region as the view angle increases. Layer thickness and view-angle dependent emission spectra of the device were analyzed in terms of microcavity theory. A reflectivity of semitransparent cathode and optical path length were deduced.

A Study on Projective Calibration for Arbitrary Display Surface using Digital Moire Method. (Digital Moire를 이용한 임의의 영사면에 대한 투영보정에 관한 연구)

  • 유원재;김도훈;강영준;백성훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.292-295
    • /
    • 2003
  • Moire topography method is a well-known non-contacting 3-D measurement method. the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this study, digital two-wavelength phase shilling moire is applied to the entertainment fields. recently. as promoting the growth of the VR-Game, display devices which attract public attention such as HMD or Projector are being appeared in order to deliver effectively the absorption sense. this study realized the Auto-calibrating system for arbitrary display surface using digital moire method which satisfied the shape measurement of display surface and the request of FOV(Field of View) output. also when large screen wasn't prepared, this auto-calibrating system was applied to enjoy games or movies at home with a projector and walls

  • PDF

Control of Polyaniline Molecular Weight Based on p-aminodiphenylamine (p-aminodiphenylamine을 이용한 폴리아닐린 분자량 조절)

  • Hong Jang-Hoo;Jeon, Je Yeoul
    • Applied Chemistry for Engineering
    • /
    • v.20 no.1
    • /
    • pp.75-79
    • /
    • 2009
  • The ratio of aniline dimer (p-aminodiphenylamine), which is a nucleation site of chain growth in a chemical polymerization of aniline monomer, to aniline monomer was controlled to synthesize polyaniline with the molecular weight ($M_w$) between 10000 and 20000 g/mol. The result of OCP measurement showed that the reaction rate of polymerization was increased as the mole ratio of dimer was increased. The increase in the molar ratio of dimer resulted in the shift of absorption wavelength of polyaniline to the short wavelength region on measurement of UV/Vis and the decrease of molecular weight on the measurement of GPC.

Diagnostics of Magnetron Sputtering Plasmas: Distributions of Density and Velocity of Sputtered Metal Atoms

  • Sasaki, Koichi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.98-99
    • /
    • 2012
  • Deposition of thin films using magnetron sputtering plasmas is a well-developed, classical technology. However, detailed investigations using advanced diagnostics are insufficient in magnetron sputtering, in comparison with plasma-aided dry etching and plasma-enhanced chemical vapor deposition. In this talk, we will show examples of diagnostic works on magnetron sputtering employing metal targets. Diagnostic methods which have fine spatial resolutions are suitable for magnetron sputtering plasmas since they have significant spatial distributions. We are using two-dimensional laser-induced fluorescence spectroscopy, in which the plasma space is illuminated by a tunable laser beam with a planer shape. A charge-coupled device camera with a gated image intensifier is used for taking the picture of the image of laser-induced fluorescence formed on the planer laser beam. The picture of laser-induced fluorescence directly represents the two-dimensional distribution of the atom density probed by the tunable laser beam, when an intense laser with a relatively wide line-width is used. When a weak laser beam with a relatively narrow linewidth is used, the laser-induced fluorescence represents the density distribution of atoms which feel the laser wavelength to be resonant via the Doppler shift corresponding to their velocities. In this case, we can obtain the velocity distribution function of atoms by scanning the wavelength of the laser beam around the line center.

  • PDF

The polymer waveguide type SPR sensor using a multi-wavelength light source (다파장 광원을 이용한 폴리머 광도파로형 SPR 센서)

  • Park, Chang-Sub;Yeom, Se-Hyuk;Kim, Do-Eok;Kang, Byoung-Ho;Kim, Kyu-Jin;Kim, Hak-Rin;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.401-406
    • /
    • 2007
  • In this paper, we fabricated the polymer waveguide type surface plasmon resonance (SPR) sensor using a white light source and optical spectrum analyzer (OSA). Fabricated sensor uses the principle of phase matching between evanescent wave and surface plasmon wave. According to the measuring result, the shift of resonance wavelength conducts the change of the refractive index. The proposed SPR sensor is expected to apply the integrated multichannel SPR sensor and the realtime monitoring system.

Two-Photon Absorption Cross Sections of Dithienothiophene-Based Molecules

  • Chung, Myung-Ae;Lee, Kwang-Sup;Jung, Sang-Don
    • ETRI Journal
    • /
    • v.24 no.3
    • /
    • pp.221-225
    • /
    • 2002
  • We performed nonlinear transmission measurements and quantum-chemical calculations on dithienothiophene(DTT)-based molecules to gain insight into the effect of acceptor and donor groups on two-photon absorption(TPA) properties. The TPA intensity showed dispersion characteristics of the single-photon absorption spectrum. When the molecules included an asymmetric donor-acceptor pair, the single- and two-photon absorption maximum wavelengths were red-shifted more than when the molecules had a symmetric donor-donor structure. We interpreted this result as indicating that the $S_2$ state plays the dominating role in the absorption process of molecules with a symmetric structure. The experimental TPA ${\delta}$ values at the absorption peak wavelength showed a dependence on the structural variations. We found the self-consistent force-field theory and Hartree-Fock Hamiltonian with single configuration interaction formalism to be valid for evaluating TPA ${\delta}$. Although the quantum-chemical calculations slightly underestimated the experimental ${\delta}$ values obtained from nonlinear trans -mission measurements, they reasonably predicted the dependence of the ${\delta}$ value on the structural variations. We confirmed the role of molecular symmetry by observing that donor-donor substituted structure gave the highest experimental and theoretical TPA ${\delta}$ values and that the donor-acceptor substituted structure showed a greater red-shift in the TPA absorption maximum wavelength. Overall, the theoretical ${\delta}$ values of DTT-based molecules were in the order of $10^{-46}\;cm^4{\cdot}s{\cdot}photon^{-1}$ and are higher than that of AF-50 by nearly two orders of magnitude.

  • PDF

A study on the influence of luminecent center on luminance in SrS:Ce electroluminescent devices (SrS:Ce EL소자에 있어서 발광중심이 휘도에 미치는 영향에 관한 연구)

  • Lee, Sang-tae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.613-616
    • /
    • 2001
  • The effect of codopants on the electroluminescent properties for SrS-Ce based thin films was studied. The active layer was deposited by electron beam with sulfur The wavelength of eletroluminecence shifted with codopants and their concentrations. The intensity ratio of blue to green were found In the CeP-doped device, but the highest total intensity of luminance showed about 850cd/$m^2$ in the CeCl$_3$+KCL-doped device, which indicates that codopants are playing an important role of luminance. At any device, the luminance was the strongest at 0.2 mol% concentration among the concentration studied, suggesting the existence of optimum concentration. By post-annealing Luminance of most devices was improved, but the shift of wavelength was not observed.

  • PDF

Development of Protein Chip for Diagnosis of Chlamydophia Pneumoniae (단백질 칩을 이용한 클라미디아 폐렴의 진단)

  • Kim, Woo Jin;Lee, Hui Young;Lee, Seung-Joon;Jung, Se-Hui;Yuk, Jong Seol;Ha, Kwon-Soo;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.4
    • /
    • pp.412-418
    • /
    • 2006
  • Background; The diagnosis of chlamydial infection is based on serology. The current gold standard of diagnosis is MIF(microimmunofluorescence), but this modality is subjective and time-consuming. Protein microarray with using a SPR(surface plasmon resonance) sensor has recently been suggested as a method for detecting infection. For developing a protein chip to diagnose chlamydial infection, EBs(elementary bodies) were immobilized on a gold chip and the interaction between an antibody for Chlamydophila pneumoniae and the EBs(elementary bodies) immobilized on the surface of the gold chip was measured by using an SPR sensor. Methods; For the surface antigen, the EBs of Chlamydophila pneumoniae LKK1 were purified. Charged arrays were prepared by using PDDA(polydiallyldimethylammonium chloride) which has a positive charge. After immobilization of the chlamydial EBs on the PDDA surface, the investigation of the surface was done with using atomic force microscopy. After the antibody for C. pneumoniae was applied on chip, we monitored the SPR wavelength-shift to detect any antigen-antibody interaction with using a self-assembled SPR sensor. Results; The chlamydial EBs on the positively charged PDDA were visible on the surface with using atomic force microscopy. The SPR wavelength increased after interaction of antibody for C. pneumoniae with the EBs immobilized on charged gold surface. The wavelength-shift was correlated with the concentration of antigens. Conclusion; The surface immobilization of EBs on the gold surface with the charged arrays was identified and the antigen-antibody interaction on the gold chip was detected via the SPR sensor. Further investigations are needed to apply this technique to the clinical field.

Photoelectrochemical Studies of Nanocrystalline TiO₂Film Electrodes

  • Lee, Myoung-Soon;Cheon, Ik-Chan;Kim, Yeong-Il
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.8
    • /
    • pp.1155-1162
    • /
    • 2003
  • Nanocrystalline semiconductor film electrodes have been prepared by sintering three different sizes of TiO₂ nanoparticle sols on conducting indium-tin-oxide (ITO) glass substrate. The electrochemical and photoelectrochemical properties of the prepared electrodes were comparatively investigated. The particle sizes, surface morphologies and crystallinities of the films were studied by scanning electron microscopy, transmission electron microscopy, and X-ray diffraction. Cyclic voltammetry and capacitance measurements in the dark implies the formation of depletion layer in the semiconductor films which was usually neglected in the previous studies and shows that flat band potential ($E_{fb}$

Synthesis and Their Properties of (0.8PPV+0.2DMPPV)/Silica Glass, Borosilicate Glass Composites by Sol-Gel Process (Sol-Gel법을 이용한 (0.8PPV+0.2DMPPV)/Silica Glass, Borosilicate Glass 복합체의 합성과 그 특성)

  • 이병우;김병호;윤영권;한원택
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.9
    • /
    • pp.993-1001
    • /
    • 1997
  • The (0.8PPV+0.2DMPPV) copolymer and silica/borosilicate composites were synthesized by sol-gel process. The organic-inorganic hybrid solution was prepared by using of (0.8PPV+0.2DMPPV) copolymer precursor solution as a raw material for organic components and TEOS and TMB for glass components. Then by drying the solution in vacuum at 5$0^{\circ}C$ for 7days and subsequent heat treatment in vacuum at 15$0^{\circ}C$~30$0^{\circ}C$ for 2h~72h with heating rate of 0.2$^{\circ}C$/min and 1.8$^{\circ}C$/min, the organic-inorganic composites were synthesized. Microstructural evolution of the composites was characterized by DSC, IR spectrocopy, UV/VIS spectroscopy, and TEM. Elimination of the polymer precursor and degradation of the polymer were observed by DSC and Si-O and trans C=C absorption peaks were identified by IR spectra. The polymer was found to be successfully incorporated into the glass matrix and it was confirmed by the absorption peaks from the polymer in the UV/VIS spectra and the TEM results. The absorption peak of the composites was found to shift toward short wavelength side compared to that of the pure polymer and the amount of the blue shift increased with increasing the heat treatment temperature and heat treatment time and with decreasing the heating rate.

  • PDF