• Title/Summary/Keyword: wavelength modulation spectroscopy

Search Result 15, Processing Time 0.022 seconds

Measurement of Exhaust Gas Concentration using Wavelength Modulation Spectroscopy (파장 변조 기법을 이용한 연소배기 가스의 계측)

  • Kim, Dong-Hyuck;Kim, Se-Won;Shin, Myung-Chul;Kim, Yong-Mo
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.97-103
    • /
    • 2006
  • This work forcus on the development of gas sensor that measure the concentrations of exhaust gas using diode laser. Each diode laser for exhaust gas measurement is set to work at near-IR using both DA and WMS methods. Also use of fiber-coupled optical elements makes such a sensor rugged and easy to align. On-line data acquisition and processing can be performed with a PC running LabVIEW software, and absorption signals are measured simultaneously by multiplexing method. Finally, It were experimentally compared WMS (Wavelength Modulation Spectroscopy) with DA (Direct Absorption) for the accuracy.

  • PDF

Species Concentration Measurement Technique Using Wavelength Modulation Absorption Spectroscopy (파장변조 광흡수 분광법을 이용한 농도 계측 기법)

  • Ahn, J.H.;Kim, Y.M.
    • Journal of ILASS-Korea
    • /
    • v.9 no.4
    • /
    • pp.67-76
    • /
    • 2004
  • Diode laser absorption sensors are advantageous because they may provide fast, sensitive, absolute, and selective measurements of species concentration. These systems are very attractive for practical applications owing to its compactness, reasonable cost, robustness, and ease of use. In addition, diode lasers we fiber-optic compatible and thus enable simultaneous measurements of multiple species along a line-of-sight. Recent advances of room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications make it possible to be applied for combustion diagnostics based on diode laser absorption spectroscopy. Therefore, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor systems are now appearing for variety of applications. The objectives of this research are to develop new gas sensing system and to verify feasibility of this system. Wavelength modulation spectroscopy has been demonstrated in these experiments and has a bright prospect to this diode laser system.

  • PDF

The Concentration Measurements of Toxic Exhaust Gas by Tunable Diode Laser Absorption Spectroscopy System (TDLAS 시스템을 이용한 유해 배기가스의 농도 계측)

  • Cha, Hak-Joo;Kim, Min-Soo;Shin, Myung-Chul;Kim, Se-Won;Chun, Kwang-Min
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.222-227
    • /
    • 2003
  • Recent advances in room-temperature, visible and near-IR diode laser sources for telecommunication, optical data storage applications are enabling combustion diagnostics system based on diode laser absorption spectroscopy. In contrast to some traditional sampling-based gas-sensing instruments, tunable diode laser absorption spectroscopy system is advantageous because of their non-invasive nature, high sensitivity, fast response time and real-time measurement capability. So, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor system arc now appearing for a variety of applications. The objective of this research is to take advantage of distributed feed-back diode laser and measure the $CO_{2}$ concentration (by using direct absorption and wavelength modulation spectroscopy methods). In addition to survey spectra of $CO_{2}$ bands and spectroscopic parameters between 1565 and 1579 run were computed at temperatures between 296 and 1200 K (by using HITRAN 2000 database). It experimentally found out that the features of direct absorption and wavelength modulation spectroscopy methods.

  • PDF

Combustion Diagnostics Method Using Diode Laser Absorption Spectroscopy (다이오드 레이저를 이용한 연소진단기법)

  • Cha, Hak-Joo;Kim, Min-Soo;Shin, Myung-Chul;Kim, Se-Won;Kim, Hyuck-Joo;Han, Jae-Won
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.75-83
    • /
    • 2003
  • Diode laser absorption system is advantageous of their non-invasive nature, fast response time, high sensitivity and real-time measurement capability. Furthermore, recent advances in room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications are enabling combustion diagnostics system based on diode laser absorption spectroscopy. So, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor system are now appearing for a variety of applications. The objective of this research is to take advantage of distributed feed-back diode laser and develope new gas sensing system. It experimentally found out that the wavelength, power characteristics as a function of injection current and temperature. In addition to direct absorption and wavelength modulation spectroscopy have been demonstrated in these experiments and have a bright prospect to this diode laser system.

  • PDF

The Experimental Study on Simultaneous Measurements of $O_2$ Concentration and Temperature of Flue Gas Using a Single Diode Laser (다이오드 레이저를 이용한 배기가스 $O_2$ 농도 및 온도 동시 측정에 관한 실험적 연구)

  • Kim, Se-Won;Shin, Myoung-Chul;Lee, Chang-Yeop;Youn, Sung-Woon;Kim, Young-Il
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.1
    • /
    • pp.12-21
    • /
    • 2012
  • Simultaneous measurements of oxygen concentration and temperature using diode laser in the combustion environment are successfully accomplished. A single DFB type diode laser of 760 nm line centre frequency is used and the scanned-wavelength direct absorption spectroscopy method and wavelength modulation spectroscopy method are applied to measure absorption signals below 793 K temperature region. The experimental results show that oxygen concentration are measured within 1% accuracy and temperature are measured within 5% accuracy. This new method of simultaneous measurements of concentration and temperature with a single diode laser shows a great promise.

Diode-Laser Absorption Sensors for measurement of combustion Gas (연소배기 가스의 계측을 위한 다이오드 레이저 센서)

  • Shin, Myung-Chul;Kim, Se-Won;Kim, Dong-Hyuck
    • Journal of the Korean Society of Combustion
    • /
    • v.11 no.3
    • /
    • pp.26-35
    • /
    • 2006
  • This work forcus on the development of gas sensor that measure the concentrations of exhaust gas using diode laser, Each diode laser for exhaust gas measurement is set to work at near-IR using both DA and WMS methods. Also use of fiber-coupled optical elements makes such a sensor rugged and easy to align. The results showed that gas concentrations of $O_2$, CO, $CO_2$, NO are accurately measured within ${\pm}2%$ error. The application of WMS method increased the beam intensity 2-3 times higher than DA method. It were experimentally compared WMS (Wavelength Modulation Spectroscopy) with DA (Direct Absorption) for the accuracy.

  • PDF

Phonon bottleneck effects of InAs quantum dots

  • Lee, Joo-In;Sungkyu Yu;Lee, Jae-Young m;Lee, Hyung-Gyoo
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.4 no.1
    • /
    • pp.27-32
    • /
    • 2000
  • We have studied the carrier relaxation of InAs/GaAs modulation-doped quantum dots depending on the excitation wavelength and modulation-doping concentration by using the time-ressolved spectroscopy. At the excitation below GaAs barrier band gap, the relaxation processes become very slow, implying to observe the phonon bottleneck effects. On the other hand, at the excitation far above GaAs band gap, phonon bottleneck effects are broken down due to Auger processes. Increasing modulation-doping concentration, the relaxation times, by virtue of Coulomb scattering between electrons in GaAs doped layer and carriers in InAs quantum dots, are observed to become fast.

  • PDF

Study on Gas Concentration Measurement of O2 and NO Using Calibration-free Wavelength Modulation Spectroscopy in Visible and Mid-Infrared Region (가시광선과 중적외선 영역의 무보정 파장 변조 분광법을 이용한 O2와 NO 가스 농도 측정에 관한 연구)

  • Aran Song;Geunhui Ju;Kanghyun Kim;Jungho Hwang;Daehae Kim;Changyeop Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.70-77
    • /
    • 2023
  • Air environment regulations have been strengthened due to increasing air pollutant emissions, the target of reducing emissions has increased and interest in gas measurement methods is also increasing. The sampling method is mainly used, but due to the spatial and temporal measurement limitations, the laser absorption spectroscopy which is a real-time and in-situ method is in the spotlight. In this study, we studied the wavelength modulation spectroscopy and described the calibration-free algorithm. The developed algorithm was modified to reflect 46 multi-absorption lines and was applied to light absorption signal analysis in visible and mid-infrared regions. In addition, the difference between the modulation parameters of laser was analyzed. As a result of reviewing the performance through O2 and NO gas measurement experiments of various concentration conditions, the linearity was R2O2=0.99999 and R2NO=0.99967.

Measurement of oxygen isotope ratio using tunable diode laser absorption spectroscopy (다이오드 레이저 흡수분광법을 이용한 산소 동위원소의 성분비 측정)

  • Park, Sang-Eon;Jung, Do-Young;Kim, Jae-Woo;Ko, Kwang-Hoon;Im, Kwon;Jung, Eui-Chang;Kim, Chul-Joong
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.1-5
    • /
    • 2004
  • Tunable diode laser absorption spectroscopy was performed for analysis of the H$_2$$^{18}$ O/H$_2$$^{16}$ O isotope ratio of a water sample which was enriched by the membrane distillation method. In order to improve the signal-to-noise ratio, the wavelength modulation spectroscopic method was used with a lock-in amplifier. The fringe noise could be suppressed by using the FFT (Fast Fourier Transform) lowpass filter and the optimization of the modulation depth of the laser frequency. The maximum deviation of $\delta$-value was measured to be$\pm$4$\textperthousand$.