• Title/Summary/Keyword: wave treatment

Search Result 570, Processing Time 0.023 seconds

A Study of Ultrasound Rehabilitation Therapy: Physiological Effects by Change of Ultrasound Intensity (초음파 치료 시 초음파 세기 변화에 따른 생리적 효과 연구)

  • Kim, S.M.;Lee, M.P.;Choi, B.C.;Choi, S.H.;Bae, H.S.;Jung, H.S.;Park, S.Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.1
    • /
    • pp.40-45
    • /
    • 2008
  • Therapeutic ultrasound which is developed for rehabilitation therapy have already been used for healing joint contracture, synechia, acute and chronic inflammatory diseases. Medical devices for pain-relief and healing using therapeutic ultrasound are actively being developed. This study measured the change of PTT with the transmitted ultrasound through the human body to find out the increase of compliance of blood vessels. Measurement method of PTT in this study is employed as useful ways to acquire physiological information of patients in the clinical case in order to measure the change of mechanical characteristics of blood vessels. This study confirmed the PTT change of rehabilitation patients through the thermal effects of ultrasound by using PTT and also found that it is possible to increase PTT by adjusting the warm water and ultrasound. The increase of PTT means the decrease of the pulse wave velocity from the cardiovascular system to the peripheral arteries. The physiological effects occurred using the warm water and ultrasound.

Development of LED Irradiation System for Cell Proliferation (세포증식을 위한 LED 조사 시스템 개발)

  • Cheon, Min-Woo;Park, Yong-Pil;Lee, Ho-Shik;Kim, Tae-Gon;Kim, Young-Pyo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.581-582
    • /
    • 2010
  • This paper performed the basic study for developing the Photodynamic Therapy Equipment for medical treatment. We developed the equipment palpating cell proliferation using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 30 step by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and Pulse Width Modulation(PWM), and the output of a high brightness LED could be controlled stage by stage.

  • PDF

Moderating Effects of Protective Factors on the Relation between Deviant Peer's Influences and Delinquency in Adolescence (청소년기 비행친구의 영향에 대한 보호요인의 조절효과 - 자아존중감, 부모애착 및 지도감독을 중심으로 -)

  • Park, Hyunsun;Lee, Sang-gyun
    • Korean Journal of Social Welfare Studies
    • /
    • no.37
    • /
    • pp.399-427
    • /
    • 2008
  • The purpose of this study is to examine the moderating effects of protective factors on the relations between deviant peer's influences and delinquent behaviors in adolescence. To investigate the moderating effects, simple slope and region of significance test based on multiple linear regression(MLR) model were used. This study used data from wave 1-2(2003-2004) of the Korea Youth Panel Survey(KYPS). Results showed that for female adolescents, self-esteem, parent monitoring, and attachment to parent moderated the link between best friend's deviancy and delinquent behaviors. For male adolescents, however, best friend's deviancy and protective factors didn't show any significant moderating effects. These results help clarify the conditions under which exposure to deviant best friends can influence delinquent behaviors in adolescence. Practice and policy implications as well as further research topic were discussed to aid the search for highly effective preventive and treatment interventions.

Analysis of Dimensionality Reduction Methods Through Epileptic EEG Feature Selection for Machine Learning in BCI (BCI에서 기계 학습을 위한 간질 뇌파 특징 선택을 통한 차원 감소 방법 분석)

  • Tong, Yang;Aliyu, Ibrahim;Lim, Chang-Gyoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1333-1342
    • /
    • 2018
  • Until now, Electroencephalography(: EEG) has been the most important and convenient method for the diagnosis and treatment of epilepsy. However, it is difficult to identify the wave characteristics of an epileptic EEG signals because it is very weak, non-stationary and has strong background noise. In this paper, we analyse the effect of dimensionality reduction methods on Epileptic EEG feature selection and classification. Three dimensionality reduction methods: Pincipal Component Analysis(: PCA), Kernel Principal Component Analysis(: KPCA) and Linear Discriminant Analysis(: LDA) were investigated. The performance of each method was evaluated by using Support Vector Machine SVM, Logistic Regression(: LR), K-Nearestneighbor(: K-NN), Decision Tree(: DR) and Random Forest(: RF). From the experimental result, PCA recorded 75% of highest accuracy in SVM, LR and K-NN. KPCA recorded 85% of best performance in SVM and K-KNN while LDA achieved 100% accuracy in K-NN. Thus, LDA dimensionality reduction is found to provide the best classification result for epileptic EEG signal.

Research on the emission of electromagnetic waves in ambulance (구급차량 내 전자파 방출에 관한 조사)

  • Yun, Jong-Geun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.1
    • /
    • pp.61-69
    • /
    • 2019
  • Purpose: The study aims to provide basic data to enhance the health of paramedics responsible for patient transport and treatment by analyzing the exposure level of paramedics to electromagnetic waves generated by electric devices used in ambulances. Methods: The study measured electromagnetic waves in ambulances in N region from July to December 2018. ME3030B produced by German Gigahertz Solutions was used to measure these waves and the maximum value was selected by moving it slowly in various directions. Each measurement part was selected and the mean value was calculated by repeatedly measuring at 10-minute intervals three times in total: $1^{st}$, $2^{nd}$, and $3^{rd}$ phase. Results: Among the electrical devices installed in the patient room of the ambulance measured at distances of 1 cm or 30 cm, results showed a high level of electric waves at the inverter ($26.25{\pm}39V/m$) and high level of electromagnetic waves ($564.00{\pm}31.75nT$) at the ozone sterilizer. According to measurements toward the front near the driver's seat, results indicated high levels of electric waves ($3.67{\pm}1.15V/m$) and electromagnetic waves ($450.00{\pm}19.52nT$) at the black box hard drive. Conclusion: Electromagnetic waves within the ambulance were stable and not beyond the range that might impact human health. However, in the case of the black box hard drive ($3.67{\pm}1.15V/m$, $450.00{\pm}19.52nT$) located under the passenger seat, it may have a direct effect on the human body and, thus it is necessary to move it to a storage area further away from the paramedics to minimized the impact.

A Study on the Changes of Blood Pressure Measurement Factors Before and After Heart Treatment (심장 치료 전후의 혈압 측정 인자의 변화에 관한 연구)

  • Choi, Wonsuk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.51-56
    • /
    • 2021
  • The brachial systolic blood pressure and pulse pressure are the predictors of cardiovascular disease in individuals over 50 years of age. As the stiffness increases, the reflex amplitude and pressure in the late systole increase, resulting in an increase in left ventricular load and myocardial oxygen demand. Therefore, it is necessary to study how stiffness affects blood pressure. In this study, the blood pressure pulse waves were measured before and after taking the drug, and the blood pressure pulse wave was measured before and after myocardial heart transplantation in patients with heart failure. The correlation between R, L, and C components of the Windkessel model was estimated by increasing blood pressure. As a result of modeling the parameters of the Windkessel model using the curve fitting method, the increase in blood pressure and decrease in systolic rise time were due to the increase in the L component in the RLC Windkessel model. Among the various mechanical characteristics of blood vessels, the most important parameter affecting high BP waveform is the inertance.

Preparation of polymer composites containing hollow magnetic particles and measurement of their electromagnetic properties (중공 자성입자를 포함한 복합재료 제조 및 전자파 특성 측정)

  • Yi, Jin-Woo;Lee, Sang-Bok;Kim, Jin-Bong;Lee, Sang-Kwan;Park, Ki-Yeon
    • Composites Research
    • /
    • v.21 no.2
    • /
    • pp.31-35
    • /
    • 2008
  • In order to design light weight and high efficient electromagnetic wave absorbing materials, hollow magnetic particles have been introduced in this study. The electroless plating method has been utilized to coat Ni and Fe on the substrates of synthesized polystyrene particles of submicron size. Removing polystyrene particles by heat treatment resulted in hollow structures. Observation by SEM, TEM and EDS confirmed the surface morphology and coating thickness of Ni and Fe. Polymeric composites containing hollow particles were tested in order to compare the electromagnetic properties between Ni coated and Fe costed particles. The composite of 30 wt% Fe hollow particles showed the higher complex permeability than Ni hollow particles or the conventional barium ferrite particles.

Investigation of Various Remedies of Ovarian Cyst except Oral Decoction of Medical Ingredients in Chinese Medicine Journals (경구탕액요법(經口湯液療法)을 제외한 난소낭종의 다양한 치료법에 대한 조사 연구 - 중의학 논문을 중심으로 -)

  • Bae, Geung-Mee;Cho, Hye-Sook;Lee, Seung-Hwan;Lee, In-Sun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.22 no.3
    • /
    • pp.152-168
    • /
    • 2009
  • Purpose: The purpose of this study is to examine remedies suggested in the papers of ovarian cyst in Chinese Medicine Journals and to establish the further direction. Methods: The papers published between 1994 and 2009 in China Academic Journal were reviewed. Results: 1. It was on Bo-Ryu Enema that main focus of investigation was placed. A variety of randomized controlled trials and case series were found. As a result, a lot of proper manual arts and prescriptions were provided out of them. 2. Acupuncture is reported as significant in reducing the size of ovarian cyst and improving clinical symptoms, which covers electrical acupuncture, enlongated needle and moxibustion, burning acupuncture. 3. External application was verified as an effective therapy for the case of a combined treatment with oral medicine. 4. Modern medical equipments such as ultra short wave medical cure, TDP could improve the efficiency of traditional remedies like Bo-Ryu Enema, external application. Conclusion: It would be necessary to practically come up with a diversity of remedies besides oral decoction of medical ingredients, and establish standard of evidence of them.

Acoustic Interface Element on Nonconformal Finite Element Mesh for Fluid-Structure Interaction Problem (비적합 유한요소망에 적용가능한 유체-구조물 연결 요소)

  • Cho, Jeong-Rae;Lee, Jin Ho;Cho, Keunhee;Yoon, Hyejin
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.163-170
    • /
    • 2023
  • In the fluid-structure interaction analysis, the finite element formulation is performed for the wave equation for dynamic fluid pressure, and the dynamic pressure is defined as a degree of freedom at the fluid nodes. Therefore, to connect the fluid to the structure, it is necessary to connect the degree of freedom of fluid dynamic pressure and the degree of freedom of structure displacement through an interface element derived from the relationship between dynamic pressure and displacement. The previously proposed fluid-structure interface elements use conformal finite element meshes in which the fluid and structure match. However, it is challenging to construct conformal meshes when complex models, such as water purification plants and wastewater treatment facilities, are models. Therefore, to increase modeling convenience, a method is required to model the fluid and structure domains by independent finite element meshes and then connect them. In this study, two fluid-structure interface elements, one based on constraints and the other based on the integration of nonsmooth functions, are proposed in nonconformal finite element meshes for structures and fluids, and their accuracy is verified.

A Scenario for the Standard Basis of Crest Elevation Estimation along Korean Coast based on Expected Overtopping Probability (마루높이 설정(設定) 기준(基準)을 위한 기대월파확률 추정 Scenario)

  • Kweon, Hyuck Min;Kim, Gun Oh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4B
    • /
    • pp.365-376
    • /
    • 2009
  • The importance of resonable treatment of tide characteristics has been shown by Kweon, et al. (2005, 2006) for the crest elevation estimation because of a big difference of tidal elevation along Korean coast. For the procedure of crest elevation design, the expected overtopping probability (EOP) was estimated by Kweon, et al. (2006). The comparisons on each sea showed that EOP was lower east, south and west sea in order. The results involved the assumption that the tide and design level wave height meet any time in a year. However, big waves mainly occur in summer or winter in Korean coast, the study focuses on the encounter probability of big waves and seasonal tide level. A theory of the encounter probability is not derived by the present study but it shows reasonable acceptability of the proposed scenario in which the expected overtopping probability could be an index for the crest elevation estimation in Korean coast. The calculation based on the scenario gives the possibility range for the crest elevation estimation which has no tendency of each sea along Korean peninsular. The range is within the expected overtopping probability of 1% in the whole coast of Korea.