• 제목/요약/키워드: wave and current

검색결과 1,934건 처리시간 0.033초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

다양한 기후변화에 따른 콘크리트 구조물의 성능중심형 설계 평가 (Evaluation of Performance Based Design Method of Concrete Structures for Various Climate Changes)

  • 김태균;심현보;안태송;김장호
    • 한국건설순환자원학회논문집
    • /
    • 제1권1호
    • /
    • pp.8-16
    • /
    • 2013
  • 현재 전 세계적으로 석탄, 석유 등 화석연료의 사용으로 지구 온난화가 진행되고 있으며, IPCC는 지난 100년간(1906~2005년) 지구 지표기온이 $0.74^{\circ}C{\pm}0.18^{\circ}C$ 상승하였고 최근 50년간의 온난화 증가 추세($0.13^{\circ}C{\pm}0.03^{\circ}C$/10년)를 살펴보면 과거 100년간의 변화($0.07^{\circ}C{\pm}0.02^{\circ}C$/10년)에 비해 거의 2배가 증가 하였다고 발표하였다. 이러한 원인으로 폭염, 폭설, 폭우 및 슈퍼태풍 등과 같은 이상기후, 극한기후 현상이 지속적으로 증가 되고 있다. 또한 이로 인하여 사회기반시설의 파괴 및 손상, 인명피해가 급증하고 있으며 콘크리트 구조물의 경우 장기간 지속되는 극심한 기후변화에 따라 급속도로 노화되고 있다. 이러한 문제들을 해결하기 위해서는 기후변화에 적합한 기준 및 시공 기술 등이 필요한 실정이다. 본 연구에서는 이러한 문제점들을 해결하고자, 콘크리트 양생에 영향을 미치는 온도, 습도, 일조량, 풍량 등 다양한 기후인자 요소 중 주요 요인인 온도와 습도를 다양한 케이스별로 실험을 실시하였으며, 각 케이스 별로 압축강도(3, 7, 28일), 할렬인장강도(3, 7, 28일)실험을 하였다. 그리고 실험 데이터를 바탕으로 콘크리트 시편의 성능을 평가하고 만족도 곡선을 작성하며, 이를 성능중심형설계방법(PBDM : Performance Based Design Method)에 적용하였다. PBD란 과거의 실험 해석과 현재의 실험 해석등의 여러 결과들을 합하여, 구조물에서 요구되는 재료 성능을 만족시키는 성능 기반형 설계법 으로써, 최근 전세계적으로 연구가 활발히 진행 중이다. 그리고 PBD의 최종 목적은 사용기간 중 구조물이 충분한 성능을 갖출 수 있도록 시공, 설계하는 것이며 이를 사용 할 경우 문제 해결에 있어서 다양한 방법을 제시 할 수 있고, 경제성과 기능성 면에서도 최대한의 효과를 이끌어 낼 수 있다.

바다모래 채취 시 해수 수질 및 생태계 영향에 대한 해양환경조사 개선 방안 (Improvements in the Marine Environmental Survey on Impact of Seawater Qualities and Ecosystems due to Marine Sand Mining)

  • 김영태;김귀영;전경암;엄기혁;김인철;최보람;김희정;김진민
    • 해양환경안전학회지
    • /
    • 제20권2호
    • /
    • pp.143-156
    • /
    • 2014
  • 본 연구에서는 우리나라의 주변 해역에서 바다모래 채취 시 발생되는 현탁류에 대해 5년간(2008년~2012년) 해양환경조사서 내 조사 현황을 검토하였다. 이 기간 동안 연 근해역 내 7곳(남해 EEZ, 서해 EEZ, 서해 EEZ 변경 단지, 태안군 관할 해역, 안산시 관할 해역, 옹진군 관할 해역 2곳)의 바다모래 채취구역 중 2곳(EEZs와 연안역 내 채취 구역 각각 1곳)에서 현탁류 내 부유토사의 확산과 이동에 관한 현장 관측이 수행되었다. 그러나 해역별 해양물리적, 지형적 특성과 기상 조건을 반영한 조사 정점 및 범위를 선정한 사례는 확인되지 않았다. 조류, 파랑, 바람장, 수심, 하계 성층화 등의 영향에 의해 부유토사는 바다모래 채취 구역을 넘어 훨씬 더 먼 거리까지 이동될 수 있다. 따라서 바다모래 채취 과정에서 해저층 퇴적물의 재부유, 그리고 준설선박의 여수토와 배사관에서 배출되는 월류수 등에서 기인한 부유토사의 확산에 대해 집중 모니터링 방안과 세부 조사 기법의 도입이 필요하다. 또한 현탁류의 확산 경로상에서 부유물질, 영양염, 중금속 등의 오염물질로 인해 주변 해양환경과 유용 수산생물이 포함된 해양생태계 등에 미치는 누적 영향을 추적하고, 환경 피해를 최소화하기 위한 통합 지침안을 마련해야 한다.

큰느타리버섯 재배사의 실태분석 - 서부경남지역을 중심으로 - (Analysis of Actual State of Facilities for Pleurotus eryngii Cultivation - Based on Western Gyeongnam Area -)

  • 윤용철;서원명;유찬
    • 생물환경조절학회지
    • /
    • 제13권4호
    • /
    • pp.217-225
    • /
    • 2004
  • 본 조사는 최근 급격히 증가하고 있는 새송이버섯 재배농가의 안정적 영농을 위해 재배사 설계, 시공 및 환경조절과 관련한 기초 자료를 마련하기 위해 서부 경남지역을 대상으로 새송이버섯 재배사의 재배사 규모, 환경조절시스템 등의 실태조사 및 검토를 하였다. 재배사의 형태는 반영구재배사와 영구재배사로 대별 할수 있었고, 반영구재배사는 대부분 단동이었고, 영구재배사의 경우는 단동에 비해 상대적으로 연동이 많았다. 그리고 재배사의 규모는 형태에 관계없이 다양하였지만, 길이, 폭 및 동고는 각각 20m, $6.6\~7.0m$$4.6\~5.0m$정도의 농가가 가장 많았으며, 동당 바닥면적은 $132\~140m^2$(40-42평)정도의 범위로서 대부분 콘크리트로 처리하여 각종 균에 의한 버섯의 오염을 방지 할 수 있도록 되어 있었다. 반영구 및 영구재배사의 지붕경사각은 각각 $41.5^{\circ}$$18.6\~28.6^{\circ}$로 나타나 반영구재배사의 지붕경사도가 더 큰 것으로 나타났다. 그리고 재배상의 폭 및 단수는 재배사의 형태에 관계없이 각각 $1.2\~1.6m$정도와 4단이 주류를 이루고 있었다. 버섯을 연중재배 하는 재배사에는 모두 냉${\cdot}$난방시설, 가습장치 및 환기팬이 설치되어 있었다. 난방방식의 경우, 온수보일러, 전기히터, 증기보일러 순으로 나타났다. 냉방장치의 경우는 모두 산업용 에어컨을 설치하여 운용하고 있었다. 그리고 가습은 초음파가습기와 원심분리가습기를 사용하고 있었으며, 보조 장치로 분무노즐을 사용하는 농가도 일부 있었다. 또한 온${\cdot}$습도 조절 및 탄산가스 조절을 위한 장치의 제어는 동별 제어시스템을 많이 채택하고 있었다. 그리고 온도센서 이외는 모두 타이머를 이용하고 있음을 알 수 있었다. 배지병의 크기는 850 cc 및 1,100 cc를 사용하는 농가가 주류를 이루고 있었고, 이 밖에도 800cc와 950 cc, 1,200 cc병을 사용하는 농가도 있었다. 출하형태는 대부분 유통회사와 공판장을 동시에 이용하고 있었다.

방조제 건설 후 이원 대조차 조간대의 계절별 퇴적학적 특성 및 퇴적환경 (Seasonal Sedimentary Characteristics and Depositional Environments after the Construction of seawall on the Iwon Macrotidal Flat)

  • 금병철;박은영;이희일;오재경;신동혁
    • 한국지구과학회지
    • /
    • 제25권7호
    • /
    • pp.615-628
    • /
    • 2004
  • 대조차 조간대에서 방조제 건설 후 발생하는 퇴적물의 분포특성과 퇴적환경의 계절적 변화를 파악하기 위해서 4계절을 대표하는 표층퇴적물을 채취, 분석하였으며, 4개의 측선에서 2년 동안 퇴적물과 퇴적률에 대한 조사가 병행되었다. 그 결과, 방조제를 축조함으로써 반폐쇄성 연안에서 개방형 연안으로 바뀐 이원 조간대의 동측 조간대 지역은 개방형 연안에서 나타나는 일반적인 계절 변화, 즉 몬순 계절풍의 영향으로 여름에는 세립질 퇴적물이 퇴적되고 겨울에는 강한 북서계절풍에 의해서 세립질 퇴적물이 제거되는 계절 변화를 보인다. 또한 측선 경사도와 퇴적물 분표양상 등을 고려할 때, 북부 지역은 조석보다는 파랑작용에 크게 영향을 받고, 남부 지역은 파랑보다는 조석작용이 크게 영향을 미치고 있지만 강한 조류, 파랑 그리고 태풍 등에 의해 시간이 지남에 따라서 조립화 현상을 보이고 있다. 반면 방조제 건설에 의해 새로운 형태로 변화된 서측 끝 지역은 조간대의 발달방향이 남동방향으로 향하고 있어 북서계절풍의 영향에서 보호되는 지역으로 동측 조간대에서 보여지는 계절변화 양상과는 약간 다르게 봄에 세립하고 불량한 분급을 그리고 여름에는 상대적으로 조립하고 양호한 분급을 나타낸다. 이는 방조제 건설에 따른 지형적 원인에 의한 것으로 판단되어진다. 따라서 연구 지역의 세립질 퇴적물 이동은 방조제에 의해서 겨울철에 동측 조간대에서 방조제 서측 끝 지역으로 이동하고 다시 여름철에는 동측 조간대로 이동되어지는 시계방향의 순환현상이 진행되는 것으로 보인다. 방조제 건설 이후 이원 조간대 지역은 2년 동안 많은 변화를 보이고 있지만 이것은 변화과정 중인 것으로 보이고 계속적인 모니터링이 필요할 것으로 보인다.EX>$s^{-1}$ 값을 보인다. 그러나, 지반의 S파 속도와 Q$s^{-1}$를 결정하는 다른 많은 요인들이 있으므로 이를 일반화하기 위해서는 연약지반의 S파 속도와Q$s^{-1}$에 관한 자료와 연구가 집적되어야 할 것이다. 매듭이 필요하였고, Field와 Giant 매듭법은 2개의 추가 반 매듭이 필요하였다. 100 N이상의 부하를 견디기 위해서는 SMC 매듭법은 3개의 추가 반 매듭이 필요하였고, 다른 3가지의 매듭법은 4개의 추가 반 매듭이 필요하였다. 추가 반 매듭이 증가함에 따라 봉합사는 풀리는 것보다 끊어지는 양상을 보였다. Duncan매듭법은 5개의 추가 반 매듭 이후에도 풀림현상을 보였고, 다른 3개의 매듭법은 3개의 추가 반 매듭 이후엔 75%이상이 봉합사의 풀림 현상보다는 끊어지는 양상을 보였다. (SMC, Field 매듭법은 92%, Ciant 매듭법은 75%)결론: 어떤 매듭법이라도 이동 매듭법 만으로는 주기적 부하 검사를 견디지 못했다. 모든 종류의 실험에서 SMC 매듭법은 최소2개의 두개의 추가 반 매듭이 필요하였다. Duncan 매듭법은 최적 매듭 유지력을 위해 3개 이상의 추가 반 매듭이 필요하였다. 모든 매듭법에서 3개나 그 이상의 추가 반 매듭이 최적 유지력에서 정점에 가까운 양상을 보였다.Knee Ligament Arthrometed의 결과에 영향을 주는 인자는 슬관절 주변 근육의 이완, 슬관절의 굴곡 각도, 경골의 회전. 전위력의 강도, 적용시점, 그리고 키, 체중등의 신체적 요인 등이 있으나 능숙한 기계사용과 정확한 슬관절 위치에서 검사할 때 전방 십자 인대 파열에 대한 진단에 유용한 기구이다

전통춤 디지털 콘텐츠에 관한 문화예술정책 연구 (Culture and Art Policies of Korean government for Traditional Dancing Digital Contents)

  • 김지원;류지성
    • 한국콘텐츠학회논문지
    • /
    • 제12권9호
    • /
    • pp.156-171
    • /
    • 2012
  • 세계적으로 한류 붐이 일면서 한국문화가 세계의 중심에 자리잡고 있는데 이로 인해 생겨난 부가가치는 측정하기 어려울 정도로 크다. 이에 따라 한국 전통춤의 원형을 보존하는 일과 디지털 콘텐츠화 작업은 정부만의 일에 그치지 않고 막대한 부가가치 가능성 때문에 문화산업측면에서 민간 부문이 관심을 크게 기울이고 있다. 그 목적을 달성하기 위해서는 콘텐츠 개발이 시급하기는 하나 한국 전통 춤의 원형의 가치를 확립하는 일이 선행되어야 한다. 대중은 문화적 가치를 재발견하는데 있어서 적극적 역할을 해야 하며 한국인의 정체성을 대표하는 전통 춤은 체계적인 예술정책의 대상이 되어야 한다. 이 논문은 전통춤 디지털 콘텐츠 개발의 실태를 점검해보고자 한다. 또한 문화원형을 보존하는 것이 지닌 현대적 가치를 재조명해봄으로써 가까운 미래의 문화예술정책의 방향에 관해 제언하고자 한다. 연구를 통해 전통춤의 원형에 관한 전문 인력이 부족한 점과, 역사적 고증 절차의 신뢰성을 점검해야할 필요가 있음을 확인했다. 산학협력단의 협동과제와 전문 인력 배치에도 불구하고 민간 기업이 인력을 양성할 수 있는 정책적 지원은 여전히 미흡한 실정이다. 즉 인력 양성과 자원 배분, 예산 확보, 민간 분야와 개인의 협력 증진, 민간 기업의 산업적 차원에서의 관심은 부족하다. 이는 문화 원형이 즉각 수입을 창출해주는 비즈니스가 아니기 때문이다. 따라서 비즈니스 지향적인 회사가 전통춤을 불가피한 요소로 인식하는 경우도 없으며 그러한 시도도 아직 없다. 이를 위해서는 콘텐츠 개발이라는 하드웨어적인 정량적 정책보다 대중의 소통과 참여와 나눔을 통해 문화수요를 촉진하는 소프트웨어적 정책이 우선 추진되어야 한다. 이를 통해 전통춤의 가치에 대한 자연스런 인식 변화를 유발할 수 있다. 이러한 정책을 통해 전통춤은 문화의 창조적 보고로서, 또한 경제적 가치를 만들어내는 공공산업으로 새롭게 인식될 것이다.

7마일 등명기를 결합한 경량화 등부표의 운동 해석 (Motion Analysis of Light Buoys Combined with 7 Nautical Mile Self-Contained Lantern)

  • 손보훈;고석원;양재형;정세민
    • 해양환경안전학회지
    • /
    • 제24권5호
    • /
    • pp.628-636
    • /
    • 2018
  • 현재 운용되고 있는 대형 등부표는 대부분 철소재로 제작되어, 부식과 침식에 취약할 뿐 아니라 중량이 커서 설치 및 유지보수가 어렵다. 또한, 주위를 항해하는 선박과 충돌시 등부표 및 선박의 구조적 피해는 물론 인명피해를 발생시키기도 한다. 이러한 철소재 등 부표의 문제점들을 해결하고자 친환경, 경량화 재질을 사용한 등부표가 주목을 받고 있고, 최근 국내에서도 부체와 상부구조물에 각각 친환경 경량소재인 EPP(Expanded Polypropylene)와 알루미늄 소재를 적용한 경량 등부표가 개발된 바 있다. 등부표가 본연의 기능을 수행하기 위해서는 복원성능 및 파랑중 (동적) 운동성능의 확보가 중요한데, 경량화 등부표는 기존의 철재 등부표와 중량 분포 및 운동특성이 다르기 때문에 이에 관한 연구가 필요하다. 본 연구에서는 새롭게 개발된 전원일체형 경량 7마일 등부표의 복원성능과 다양한 환경조건(파도, 바람, 조류)하에서의 운동성능을 평가하였다. 계류시스템을 고려한 운동해석에는 ANSYS사의 AQWA를 사용하였으며, 운동성능 추정의 정도 향상을 위하여 상용 CFD SW인 Simens사의 STAR-CCM+를 사용해 추정한 풍하중 및 조류하중을 운동해석에 사용하였다. 추정된 등부표의 유의운동의 최대값을 비교한 결과, 바람보다는 파도와 조류가 운동성능에 상대적으로 큰 영향을 미치며, 해상상태가 나빠질수록(Beaufort No. 3이상) 운동이 급격히 커지는 것으로 예측되었다. 이는 해상상태가 나빠지면서 불규칙 파 에너지 스펙트럼의 최대 주파수가 등부표의 고유주파수에 근접하기 때문으로 추정된다.

관상동맥 우회술 후 심근경색의 표지자로서 Creatine Kinase MB 농도와 Cardiac Troponon I의 임상적 의의 (Clinical Significance of Creatine Kinase MB mass and Cardiac Troponin I as a Marker of Perioperative Myocardial Infarction After Coronary Artery Bypass Grafting)

  • 이재진;김응중;이원용;신윤철;지현근
    • Journal of Chest Surgery
    • /
    • 제35권1호
    • /
    • pp.27-35
    • /
    • 2002
  • 배경: 술후 심근경색(perioperative myocardial infarction;PMI)은 관상동맥 우회술 후 중요한 합병증 중 하나이다. PMI의 진단 방법 중 CK-MB 활성도(CK-MB activity) 측정보다 민감하고, 간단한 측정 방법을 가진 CK-MB 농도(CK-MB mass)의 측정으로 점차 대체되고 있다. 또한, cardiac troponin I(cTnl)는 심근경색의 표지자로 민감도와 특이도가 가장 높은 것으로 소개되고 있다. 본 연구는 관상동맥 우회술 후 심근경색의 표지자로서 CK-MB농도와 cTnl의 임상적 의의성에 대한 평가를 보고하고자 한다. 대상 및 방법: 2000년 4월부터 2001년 4월까지 강동성심병원에서 관상동맥 우회술을 받은 32명의 환자를 대상으로 하였다. 술후 CK-MB 활성도, CK-MB농도, cTnl, 심전도, 심초음파, 임상적 자료를 전향적으로 기록하였다. 술후 심근경색의 진단은 심전도에서 새로운 Q파 출현, CK-MB 활성도가 72시간안에 200 lU/L 이상, 심초음파에서 심근벽의 새로운 심근벽 운동이상 등의 3가지 중 2가지 이상인 경우로 정의하였다 결과: 관상동맥 우회술 후 3례에서 진단 기준에 부합된 경우였다. 시간 경과에 따라, 술후 12시간의 CK-MB활성도와 술후 24시간의 CK-MB농도(R=0.946), 술후 48시간의 cTnl(R=0.933)는 매우 상관성이 있었다(p=0.000). PM의 진단기준치를 찾기 위해 ROC(receiver operating characteristics) 곡선을 이용하였으며, PMI의 환자중 술후 24시간에서 CK-MB 농도가 30.05 ug/L보다 높은 측정값에서 PMI를 발견할 수 있었고, 이 때의 ROC 곡선의 하단 단면적은 1이었으며, 민감도 100%, 특이도 100%, 양성 예측도 100%, 음성 예측도 100% 이었다. cTnI의 경우 술후 48시간에서 17.15ug/L보다 높은 측정값에서 PMI를 발견할 수 있었고, 이 때의 ROC 곡선의 하단 단면적은 0.98이었으며, 민감도 100%, 특이도 96.6%, 양성 예측도 75%, 음성 예측도 100% 이었다. 결론: 관상동맥 우회술 후 심근경색의 진단적 표지자로서 CK-MB농도와 cTnl의 측정은 간단하고 정확한 방법으로 판단되며, 진단기준치를 제시함으로서 술후 심근경색의 조기 발견을 가능하게 할 수 있을 것이라 생각된다. 그러나 본 연구에서는 대상환자 수가 적었고, 적은 수의 환자에서 심근경색이 발생하여 통계적인 제한이 있을 수 있어 향후 더 많은 대상의 수가 필요할 것으로 사료된다.