• Title/Summary/Keyword: waterworks

Search Result 285, Processing Time 0.037 seconds

Web Based Comprehensive Environmental Control Engine (Web 기반의 종합적 환경제어시스템의 개발 및 적용)

  • Kim, Joon Hyun
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.293-300
    • /
    • 1999
  • This paper is aimed at the development of comprehensive environmental management system, which can be operated on the basis of world wide web. This study has been initiated as a topic of G7 project in 1988, and will be accomplished in 2001. Even thought there should be lots of works remaining to achieve this goal, preliminary products can be summarized as follows : 1) integrated environments information management system, 2) web based control engine, 3) surface water environment management system, 4) subsurface water environment management system, 5) sewer and waterworks management system. The core methodology of the engine is the generalized multidimensional finite element matrices to depict the terms in the analysis of various partial differential equations. Spatial information management system (ArcView) and Visual Basic were extensively employed to construct GUI oriented web based engine. Developed systems were consist with very intense computer codes due to the necessity of combinatory management of environmental problems. The web based engine could be served as a decision tool for the integrated management of environmental projects in Korea.

  • PDF

A Study on the Analysis of Cavitation in Intake Pump (취수펌프에서의 캐비테이션 분석에 관한 연구)

  • Kim, Yong-Yeol;Cha, In-Ho;Lee, Je-Geun;Kwon, Gi-Bum;Lee, Jong-Ik;Kim, Han-Il
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.144-147
    • /
    • 2008
  • Intake pump for waterworks is badly damaged by a small amount of cavitation because of variable water quality and severe operation conditions. In general, the required NPSH for reduced cavitation can be provided by inlet condition, supply air, change pump and inducer. But once the pump has been built and installed there is little that can be done to reduce cavitation damage. In this study, we analysed the cavitation of paldang intake pump and intended to avoid the same phenomena.

  • PDF

Characteristics of Longevity Factor with Time and Spatial Changes (시간$\cdot$공간적 변화에 따른 장수지수 결정 요인의 특성)

  • 김한중;정남수;김대식;윤성수;이정재
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.3
    • /
    • pp.116-126
    • /
    • 2003
  • In this study, we research about the relationships of human longevity and environments, inducted the significant factors of longevity from the statistical analysis, and represented spatial distribution of longevity using geographic information system. The factors confining human longevity can be categorized by geography/geology, climate/weather, economy, and social welfare. After analyzing statistical data, dependent variable which means the longevity index is defined by the ratio of population more than 85 years old among population more than 65 years old. The results of analysis show that longevity are related with waterworks ratio, temperature, local tax ratio, and latitude. In this study we discussed about the spatial characteristics which are represented by variance of the longevity index and described a spatial relationship between the longevity index and significant factors which are chosen by statistical analysis. In the further study, in order to sustain the longevity of a region, it is necessary for the effective rural planning to propagate a longevity of rural areas.

The Actual Conditions of Plumbing Materials for Waterworks in USA and Europe (미국(美國)과 유럽의 상수도배관재(上水道配管材) 사용(使用) 실태(實態))

  • Kim, Young Ho
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.20 no.1
    • /
    • pp.29-38
    • /
    • 1991
  • 설비분야(設備分野)에서 어느 용도(用途)에 어떤 재질(材質)의 배관재(配管材)를 사용하는 것이 가장 효과적(效果的)인가 하는 것은 관계 기술자(技術者)들의 관심사항중 하나이다. 특히 상수도(上水道) 분야(分野)는 정부(政府)가 주도하는 관계로 특별한 경우가 아니면 외국(外國)의 사례(事例)를 조사(調査)할 기회가 거의 없다. 본고(本稿)는 일본수도협회(日本水道協會)(JWWA)가 상수도(上水道) 기술정보(技術情報) 교환사업(交換事業)의 일환으로 미국의 주요 도시(都市)와 유럽의 주요 국가(國家)를 대상으로 실시한 상수도(上水道) 배관재(配管材) 사용실태(使用實態) 조사결과(調査結果)를 조사(調査)팀에 참가(參加)했던 관계기관(關係機關)을 통하여 입수(入手)하여 정리한 것이다. 조사(調査) 대상(對象)이 된 국가(國家)는 미국(美國), 스웨덴, 네델란드, 서독(西獨) 및 프랑스이며, 관계기관(關係機關)으로는 각국의 수도협회(水道協會)와 이와 유사한 9개 단체(團體)이다.

  • PDF

Studies on Chlorine Demand and Its Decay Kinetics in Chlorinated Sewage Effluents (하수의 염소 소독시 총잔류염소 감소 특성에 관한 연구)

  • Beck, Youngseog;Sohn, Jinsik
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.176-183
    • /
    • 2005
  • Chlorination of wastewater is recently practiced in Korea. While many researchers have studied the kinetics of aqueous chlorine(HOCl) with nitrogeneous compounds and other organic/inorganic contaminants in drinking water, the researches of wastewater chlorination are relatively few. The purpose of this study was to investigate the chlorine decay kinetics and parameters on wastewater chlorination. Chlorine decay rate increased with increasing initial chlorine concentration. The parameters affecting chlorine decay rate were different in each wastewater treatment plant. One of the most important parameters affecting chlorine decay was initial chlorine concentration, and other parameters such as $NH_3-N$, total coliform, $UV_{254}$ and Fe were also affected. The decay ratio of chlorine was decreased with increasing initial chlorine concentration, and the disinfection efficiency showed good correlation with the decay ratio.

The Plan of Safety for Pump Station through Hydraulic Transient Analysis & Demonstration (과도수리현상 해석과 실증을 통한 펌프장 안정성 확보방안)

  • Ra, Beyong-pil;Kim, Jin-man;Park, Jong-ho;Kim, Kyung-yup
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.199-207
    • /
    • 2004
  • Water supply facilities are recently getting larger according as domestic waterworks become multi regional water supply system. Large water supply facilities generally consist of the intake pumping station, water treatment station and water supply & distribution facilities. Although pumping stations and pipeline systems are used to pump up water, it often happens pipeline damage and flooding accident by the water hammer. As a result of this study, a pumping station is guaranteed by the computer simulation and field test analysis. Therefore these are contributed safety operation in pumping station through adjustment of the pumping station safety plan, air valve and valve closing time.

  • PDF

Studies on the Effect of Water Quality Parameters on Total Coliform Concentrations in Sewage Effluents (하수방류수의 대장균군 발생에 영향을 미치는 수질인자에 관한 연구)

  • Beck, Young-Seog;Sohn, Jin-Sik
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.166-171
    • /
    • 2006
  • The objectives of the present paper were to investigate the concentration of total coliform in wastewater effluents and the effect of water chemical and physical characters in it. The most correlated parameter with total coliform was COD. It means that the wastewater treatment efficient effects on total coliform concentration. And we developed predictive model for the total coliform concentration. The estimated parameters for model were COD, temperature, nitrite, chloride, Mn and regression model equation was determined; log (Total Coli.) = 1.861+0.065[COD]+0.038[temperature]-0.0004[$Cl^-$]+3.697[Mn]-0.32 [$NO_2-N$] The developed model provided very strong correlation ($R^2:0.82$) between total coliform and regression equation. The parameters having high sensitivity were COD and temperature. So the study indicated that if the temperature and COD of wastewater effluent were known, we would estimate the concentration of total coliform and decide the most effective usage of chlorine.

Damage of Waterworks Facilities on the Iwate-Miyagi Nairiku Earthquake Disaster in 2008 (2008년 이와테.미야기 내륙지진에 의한 상수도 피해와 제언)

  • Han, Youn-Hee;Ishibashi, Yoshinobu;Katou, Nao;Lee, Sang-Hoon
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.78.2-78.2
    • /
    • 2010
  • 2008년 6월 14일, 일본 이와테(암수(岩手)) 미야기(궁성(宮城)) 내륙 지진이 발생하였다. 평야지역에서의 피해는 경미하였지만, 산간지역은 괴멸적인 피해를 입은 것이 가장 큰 특정이다. 특히, 산간지역의 간이수도 등, 소규모 수도 시설의 지하수원이 고갈되고 정수시설의 경사면이 붕괴되는 등의 피해를 입었다. 또, 지진발생 후, 원수의 높은 탁도와 색도가 시간이 경과한 시점에서도 낮아지거나 없어지지 않았던 곳이 많았다. 이번 연구보고에서는, 간이수도 등의 피해와 상호지원 체제의 상황을 보고함과 동시에 소규모 수도시설의 지진 재해에 대한 제언을 제시하고자 하였다.

  • PDF

Characteristics of Bending Strength on Coating Condition of Metal Surface Polyurethan Coating Material (금속표면에 폴리우레탄코팅한 소재의 코팅조건 변화에 따른 굽힘강도 특성)

  • 이강길
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.124-129
    • /
    • 2001
  • The research on anticorrosive of valve for ship, waterworks, and drainage system is very important. The purpose of this paper is to develop the metal/polyurethan adhesive technique at insider of the value to prevent corrosion in the value. It is performed to the bending strength test by using metal /polyurethan in the metals (SB41, Al6061). It is investigated to the effects of bending strength on curing temperature, preheating time and curing time, and to the fracture mechanism of metal/polyurethan adhensived specimen. As a results, we find that the bending strength is the highest at curing temperature of 11$0^{\circ}C$ and the curing time is 60 minutes in metal/polyurethan adhesive specimen.

  • PDF

The Efficiency Improvement of Flocculation Facilities in Water Treatment Plants (정수장 응집설비의 효율증대 방안연구)

  • Jeon, Bok-Su;Lee, Eun-Woong;Lim, Su-Saemg;Choi, Jae-Young;Kim, Hong-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.952-954
    • /
    • 2000
  • In the cleaning-water treatment process, the flocculation machine is operated by the V.S motor when the coagulation-facility of the coagulation-process is operated. But after the flocculation machine is stopped by an instantaneous power failure, the transient takes place when the coagulation facility is re-started. To improve the transient state, we developed the reinforcement-circuit which had the function of soft-start and adapted to the field. As a result of this study, we reduced the damage of facilities and had the safety in maintaining the quality of water and improved the efficiency in the maintenance and the management.

  • PDF