• Title/Summary/Keyword: water-reducing

Search Result 2,780, Processing Time 0.032 seconds

Cooling Performance of Geothermal Heat Pump Using Surface Water Heat Exchanger (지표수 열교환기 적용 지열 히트펌프 시스템의 냉방 성능)

  • Lim, Hyo Jae;Kong, Hyoung Jin;Sohn, Byonghu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.316-326
    • /
    • 2017
  • Commercial buildings and institutions are predominantly cooled, thereby dissipating excess heat to a vertical ground heat exchanger (VGHE), than heat extracted over an annual cycle. Surface waters, such as lakes and ponds, provide a cost-effective means of reducing the VGHE length, and in balancing the thermal loads to the ground. This paper presents the measurement and analysis of the cooling performance of ground-coupled heat pump (GCHP) system, using surface water heat exchanger (SWHE) submerged in an artificial pond. In order to measure the performance of the system, we installed monitoring equipment, including sensors, for assessing the temperature and power consumption, after which the operation parameters were determined. The results from the thermal performance test for the SWHE indicate that the temperatures at the outlet of the SWHE and within the pond were affected by outdoor air temperature. In addition, the results reveal similar variation trends on temperatures; however, the peak temperatures of the SWHE were somewhat greater than those of outdoor air, due to the thermal capacity of the pond. Analyzing the cooling performance over the measurement period, the average coefficient of performance (COP) of heat pump was found to be 5.71, while that for the entire system was 2.99.

Comparative Radical Scavenging and Nitric Oxide Production Capacity of Water Extracts of Acanthopanax divaricatus var, Albeofructus and Eleutherococcus divaricatus var. Chiisanensis (지리산오가피와 흰털오가피 열수추출물의 라디칼 제거 활성 및 대식세포에서의 산화질소 생성능 비교)

  • Kim, Dong-Min;Jin, Bora;Kim, Ji Yeon
    • Journal of Applied Biological Chemistry
    • /
    • v.57 no.4
    • /
    • pp.337-340
    • /
    • 2014
  • In the present study, water extracts of Acanthopanax divaricatus var, albeofructus and Eleutherococcus divaricatus var. chiisanensis were prepared and their antioxidant and anti-inflammatory effects were compared. The water extract of Acanthopanax divaricatus var, albeofructus showed significantly higher activity in total polyphenol and flavonoid contents, while there were no significant differences in ABTS/DPPH radical scavenging activities and ferric reducing antioxidant power. However, the water extract of Eleutherococcus divaricatus var. chiisanensis at the highest dose showed significantly lower capacity in nitric oxide production than that of Acanthopanax divaricatus var, albeofructus. Taken together, there were differences between Acanthopanax divaricatus var, albeofructus and Eleutherococcus divaricatus var. chiisanensis in total polyphenol/flavonoid contents and anti-inflammatory effect, however, the antioxidant effect was almost similar.

The Effect of Stationary Fin and Buoyancy Devices on Dynamic Pitching of the Tracked Vehicle (궤도차량의 동적 피칭에 미치는 고정식 핀(Fin) 및 부력장치의 영향)

  • Park, KyungChul;Kim, HyeongHyeon;Kwon, JoonSik;Kim, KyungRo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.220-225
    • /
    • 2015
  • In this study, the effect of stationary fin and buoyancy devices on dynamic pithing of the tracked vehicle was investigated. For this work, the stationary fin and buoyancy devices were installed in front of body and then pitching variation was measured when rapidly reducing the vehicle speed in water operation. According to the results of measuring the freeboard at each case, when only fin was installed, the effect on freeboard of tracked vehicle in water was negligible. However, when buoyancy devices were installed, front freeboard was approximately increased by about 20~25 mm and rear freeboard was decreased by about 10~15 mm per each addition of 100 kg buoyancy device. Based on the calculation result of pitching decrease rates, it was found that the pitching variation was decreased approximately 12.3 % by fin installation and approximately 2 % by installation of each 100 kg of buoyancy device. The case in which only fin installation was made showed the best efficiency in decreasing pitching variation of the tracked vehicle in water compared to the other cases.

Stomatal Control and Strategy Segregation to Drought Stress in Young Trees of Several Oak Species (수종 참나무속 유식물의 건조스트레스에 대한 기공저항의 조절과 전략의 분화)

  • 김종욱;김준호
    • The Korean Journal of Ecology
    • /
    • v.17 no.3
    • /
    • pp.241-249
    • /
    • 1994
  • Leaf diffusive resistance (LDR), stomatal density, length of guard cell and hair density of leaves of 6 oak species were determined under withdrawal of water, and their strategies of drought stress were analyzed by principal component analysis. LDR of Quercus acutissima, Q. aliena and Q. serrata increased earlier than those of the other species at high leaf water potential $({\Psi}_{leaf})$ or low water saturation deficit (WSD), which was an avoidance mechanism reducing damage by water stress. Q. variabilis with low stomatal density, small stomatal size and high hair density had avoidance mechanisms increasing LDR at high $({\Psi}_{leaf})$ However, Q. mongolica and Q. dentata increased LDR at low $({\Psi}_{leaf})$ as xeric species do. Results from principal component analysis on the 15 variables related to strategies of drought stress indicated that the 6 oak species were divided into 2 groups: (1) Q. acutissima, Q. aliena and Q. serrata as mesic habitat species and (2) Q. variabilis, Q. mongolica and Q. dentata as xeric habitat species. Among three xeric species Q. acutissima differed from the other two species in the drought strategies such as high hair density, low stornatal density, high leaf area ratio, stomatal closing at low $({\Psi}_{leaf})$ and small cell wall elasticity. The results could reasonably explain their drought strategies in natural habitat.

  • PDF

Numerical Simulation on the Behavior of Air Bubble Discharging into a Water Pool through a Sparger without Load Reduction Ring (하중저감 링이 없는 증기분사기를 통해 수조로 방출되는 기포 거동에 대한 수치해석)

  • 김환열;배윤영;송진호;김희동
    • Journal of Energy Engineering
    • /
    • v.12 no.4
    • /
    • pp.259-266
    • /
    • 2003
  • Load reduction ring (LRR) was installed on the ABB-Atom sparger to reduce the oscillatory loadings due to the air bubble clouds in the water pool in case of safety relief system operations. In order to investigate the effect of LRR on the pressure field, a numerical simulation on the behavior of air bubble clouds discharging into a water pool through a ABB-Atom sparser without LRR was performed by using a commercial thermal hydraulic analysis code, FLUENT 4.5. Among the multi-phase models contained in the code, the VOF (Volume Of Fluid) model was used to simulate the interface of water, air and steam flows. By comparing the analysis results with the previous ones, the load reduction ring has an effect on reducing the oscillatory loads at the wall. It also includes the effect of air mass and inlet boundary conditions of the pipe on the pressure oscillations at the wall.

Sulfonated poly(arylene ether copolymer)-g-sulfonated Polystyrene Membrane Prepared Via E-beam Irradiation and Their Saline Water Electrolysis Application (전자빔조사를 이용한 술폰화 폴리아릴렌 에테르 술폰-g-술폰화 폴리스틸렌 분리막 제조 및 염수전기분해 특성평가)

  • Cha, Woo Ju;Lee, Chang Hyun
    • Membrane Journal
    • /
    • v.26 no.6
    • /
    • pp.458-462
    • /
    • 2016
  • Saline water electrolysis, known as chlor-alkali (CA) membrane process, is an electrochemical process to generate valued chemicals such as chlorine, hydrogen and sodium hydroxide with high purities higher than 99%, using an electrolytic cell composed of cation exchange membrane, anode and cathode. It is necessary to reduce energy consumption per a unit chemical production. This issue can be solved by decreasing intrinsic resistance of the membrane and the electrodes and/or by reducing their interfacial resistance. In this study, the electron radiation grafting of a $Na^+$ ion-selective polymer was conducted onto a hydrocarbon sulfonated ionomer membrane with high chemical resistance. This approach was effective in improving electrochemical efficiency via the synergistic effect of relatively fast $Na^+$ ion conduction and reduced interfacial resistance.

Numerical Investigation of the Spray Behavior and Flow Characteristics of Urea-Water Solution Injected into Diesel Exhaust Pipe (디젤 배기관에 분사된 우레아 수용액의 분무 거동 및 유동 특성에 관한 연구)

  • An, Tae Hyun;Kim, Man Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.1
    • /
    • pp.41-48
    • /
    • 2014
  • A urea-SCR system suffers from some issues associated with the ammonia slip phenomenon, which mainly occurs because of the shortage of evaporation and thermolysis time, and this makes it difficult to achieve an uniform distribution of injected urea. A numerical study was therefore performed by changing such various parameters as installed injector angle and application and angle of mixer to enhance evaporation and the mixing of urea water solution with exhaust gases. As a result, various parameters were found to affect the evaporation and mixing characteristics between exhaust gas and urea water solution, and their optimization is required. Finally, useful guidelines were suggested to achieve the optimum design of a urea-SCR injection system for improving the DeNOx performance and reducing ammonia slip.

Comparison of Prunus yedoensis Matsumura bark ethanol extract and solvent fraction antioxidant activities (왕벚나무 껍질의 에탄올 추출물과 용매 분획물의 항산화활성 비교)

  • Joo, Shin Youn
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.4
    • /
    • pp.350-356
    • /
    • 2020
  • This study was conducted to investigate the antioxidant compounds and activities of Prunus yedoensis Matsumura bark (PYMB) ethanol extracts (EE) and various other fractions. Among them, the highest total phenol content was 496.80 mg gallic acid equivalent/g in the ethyl acetate fractions (EAF). The flavonoid contents were 7.26-265.52 rutin equivalent mg/g, with the EAF showing the highest levels. The highest proanthocyanidin content was determined to be 326.31 catechin equivalent mg/g in the EAF and the remaining values in descending order were as follows: n-butanol, ethanol, dichloromethane, water, and n-hexane. EAF exhibited the highest DPPH, ABTS+, superoxide- radical scavenging activities, and reducing power, whereas the nitrite scavenging activities were the highest in the case of the EE. The n-hexane and water fraction antioxidant compounds and activities were lower than those of the other fractions. In summary, these results suggest that the PYMB EAF is a potential source of natural antioxidants.

Emission Evaluation of Emulsion Fuel Prepared from Bunker C Oil (벙커 C유를 사용한 에멀젼 연료유의 배기가스 특성)

  • Lim, HeungKyoon;Lee, MyungJin;Chi, Gyeong-Yup;Lim, JongChoo
    • Applied Chemistry for Engineering
    • /
    • v.28 no.2
    • /
    • pp.186-192
    • /
    • 2017
  • In this study, water in oil (W/O) emulsion fuel was prepared with surfactant mixture of OIMS90 and NP12 by varying ratio of water to bunker-C oil, surfactant concentration and composition, emulsification time, stirring intensity, temperature and mixing time. Diesel engine performance and exhaust emissions were measured and analyzed with prepared emulsified fuel and compared with those measured using bunker Coil. The results indicated that bunker C emulsion fuel stabilized by surfactant mixture of OIMS90 and NP12 is efficient in reducing emissions of particulate matter, $NO_2$, CO, $CO_2$ and $SO_2$. The biggest reduction in exhaust emission was achieved by using emulsion fuel prepared by OIMS90/NP12 = 4 : 6, 500 ppm of total surfactant concentration and 10% water content at $80^{\circ}C$. Boiler efficiency test measured with emulsion fuel showed excellent energy efficiency compared with bunker C oil.

The measures to reduce sewer odor in South Korea through sewer odor reduction system in Los Angeles and San Francisco (Los Angeles와 San Francisco의 악취 저감 시스템을 통해 본 우리나라 하수도의 악취 저감 방안)

  • Ji, Hyonwook;Yoo, Sungsoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.445-451
    • /
    • 2018
  • Urban sanitary sewer systems can aid in preventing inundation, and can improve civil health by effectively disposing stormwater and wastewater. However, since sewage odor can cause adverse effects, numerous technical and administrative studies have been conducted for reducing such odor. European countries and the United States of America (USA) built modern sewer systems in the late 19th century, and have since been endeavoring to eliminate sewage odors. Several cities of the USA, such as Los Angeles (LA) that has a separate sewer system and San Francisco (SF) that has a combined sewer system, have produced and distributed odor control master plan manuals. Features common in the odor reduction plans of both these cities are that the odor reduction programs are operated in all the respective local regions and are supported by administrative systems. The primary aspectual difference between the two said programs is that the city of LA employs a sewage air purification system, whereas the city of SF controls the emission of major odor causing compounds. Compared to the existing sewer odor reduction systems of these two cities, South Korea is still in the initial phase of development. Through technical studies and policy implementations for sewer odor reduction, a foundation can be laid for improving the civil health quality.