• Title/Summary/Keyword: water-reducing

Search Result 2,780, Processing Time 0.037 seconds

The Effects of Water Spray on the NOx Formation of a Counterflow Flame (물분사가 대향류 화염의 NOx 생성에 미치는 영향)

  • Jung, Sun-Wook;Min, Byoung-Hyouk;Kim, Ho-Young;Chung, Jin-Taek
    • 한국연소학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.8-16
    • /
    • 2001
  • Various technologies for the reduction of atmospheric pollution have been developed. One of which is to inject fine-water droplets directly on the flame. This way decreases the formation of thermal NOx due to the temperature drop during evaporation of droplets. There is another effect of reducing prompt NOx, which is resulted from delay of response time and the flow of droplets. In this experiment, it has been investigated the effects of changes of water droplets size and flow rate on temperature and formations of NOx at the counterflow diffusion flame.

  • PDF

Evaluation of Passive Cooling Effect on Roof Pond through Field Observation (관측에 의한 옥상 수공간의 자연냉각효과 평가)

  • Jeong, Seong-Jin;Choi, Dong-Ho;Lee, Bu-Yong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.85-89
    • /
    • 2008
  • This study carried out field observations of measuring thermal environment, especially evaluating amount of water evaporation at roof Pond by field observations during the summer. Thermal environment measuring was categorized as air temperature, water temperature of roof pond, surface temperature, globe temperature, short and long wave radiation, net radiation, and amount of water evaporation by water level measurement. Results from this study could be used as fundamental for reducing heat Island phenomena.

  • PDF

Removal of Dissolved Oxygen from the Make-up Water of NPP Using Membrane-based Oxygen Removal System

  • Chung, Kun-Ho;Kang, Duck-Won;Hong, Sung-Yull
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.541-547
    • /
    • 1999
  • Corrosion control, in the end-shield cooling system of Wolsung Nuclear Power Plant, is directly related to the control of dissolved oxygen (DO). The current method, being used to deoxygenate the end-shield cooling water, is a chemical treatment by addition of reducing agent, hydrazine, to react with DO. This method has several limitations including high reaction temperature of hydrazine , unwanted explosive hydrogen gas production, and its intrinsic harmful property. A new approach to remove DO using a membrane-based oxygen removal system (MORS) was tried to overcome limitations of the hydrazine treatment. The DO removal efficiency of the MORS was found to be in the range 87% to 98%: The higher vacuum, the lower water flow rate and the higher water temperature tend to increase the DO removal efficiency.

  • PDF

A Study on reduction of drainage noise for water closet (공동주택 변기 배수소음 저감 방안에 관한 연구)

  • 김인수;고철수;문재호;한문성;심경석;이준서
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.881-885
    • /
    • 2001
  • The study about a drainpipe of water closet was performed as reduction of drainage noise for water closet. The Drainage noise is composed two characteristics. One is Low frequency noise and the other is high frequency noise. Low frequency noise is dominant in the first stage and high frequency noise is dominant in the last stage. This is due to water splashing and that is caused by formation of chamber pot. In this experiment, for the purpose for reducing the noise, we choose the hollow rubber pipe element. As a result, we reduced drainage noise about 11㏈A.

  • PDF

Performance Evaluation of Automatic Self-Cleaning Filter System using Twin-Fluid Nozzles for Air Cleaning in the Subway Stations (지하철 공기청정을 위한 2유체노즐형 자동세정 공기청정 시스템 개발에 관한 연구)

  • Ahn, Y.C.;Lee, J.K.
    • Journal of ILASS-Korea
    • /
    • v.9 no.3
    • /
    • pp.15-21
    • /
    • 2004
  • The removal of the dusts in the subway stations, tunnels, factories and buildings becomes issue for comfortable indoor and outdoor conditions. There has been used an automatic self-cleaning filter system to collect the dusts. In general, the collected particles are removed by water spray nozzles. The new design for improving the cleaning efficiency of collected dusts and reducing the supplied water is the concept of the plane array of demister filters and the twin-fluid nozzle for mixing compressed air and water in the automatic self-cleaning filter system. Results show that the cleaning efficiency of twin-nozzle filter systems is 99.1%, compared to 47% in the conventional filter system. Therefore the automatic self-cleaning filter system using twin-fluid nozzle filter systems reduces water supplied in the filter system, and increases cleaning efficiency and drying efficiency.

  • PDF

The Synthesis of Poly(DADM) Flocculant and Properties in Potable Water Treatment (Poly(DADM) 고분자 응집제의 합성 및 상수처리 특성)

  • 박이순;신준호;최상준;신명철;이석훈
    • Journal of Environmental Science International
    • /
    • v.7 no.5
    • /
    • pp.687-692
    • /
    • 1998
  • Poly(DADM) was synthesized for the drinking water treatment. Poly(DADM) was produced by the free radical polymerization of diallyldimethylammonium chloride(DADM) monomer and its properties were characterized. The effects of monomer concentration, initiator concentration and reaction time on synthesis of poly(DADM) were investigated. Poly(DADM) flocculant was applied to Nak-dong river water to examine its efficiency in reducing turbidity. The synthesized poly(DADM) was effective as flocculant for drinking water treatment. The addition of 1 mg/L of poly(DADM) flocculant caused the reduction of 50% PAC(polyaluminium chloride).

  • PDF

A Study on Smoke Movement Characteristics for Water spray system Installation in Tunnel (터널내 수분무 시설 설치시 연기유동 특성 연구)

  • Lim, Kyung-Bum;Kim, Ha-Young;Yoo, Ji-Oh;Rie, Dong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.230-233
    • /
    • 2008
  • In this study, we conducted an FDS simulation for the purpose of carrying out a basic assessment of the usefulness of the water spray for fire extinguishing. We analyzed the effect of securing the stability in temperature and smoke density in case of fire according to fire intensities and changes in wind speed. When there was no wind speed in tunnels, it was effective in securing the safety of people because the cooling effect of the water spray system had an excellent effect on reducing temperatures and smoke densities there.

  • PDF

A Study on the Improvery Efficiency of Heavy Water Vapour for CANDU Reactor Systems (CANDU형 원자력 발전소의 중수 증기 회수율 증대 방안에 관한 연구)

  • 김윤제;박이동;황영규;이도영
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.101-112
    • /
    • 1995
  • In order to improve the recovery efficiency of heavy water vapour from the atmosphere inside a reactor building, and to recover and upgrade the heavy water which escape, special treatments, such as reducing the ingress of light water vapour, are studied in the design of the CANDU reactor systems. This is considered in controlled method of the humidity over drawing fresh air through a desiccant dehumidifier which dries the air by absorption. Comparing with the moisture loads between summer and winter operations, the moisture removal rates are calculated. Those are proportional to the difference between the controlled space and the surrounding environment Installation of a new dehumidifier will be able to reduce the moisture loads from the cooling systems, improving overall system efficiency and saving operating costs.

  • PDF

A study on the development of the high efficiency condensing heat exchanger (고효율 응축형 열교환기 개발에 관한 연구)

  • Lee, Geum-Bae;Park, Sang-Il;Park, Jun-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.589-601
    • /
    • 1997
  • A computer simulation program of a high efficiency condensing heat exchanger is developed. The flue gas flows outside bare tube bundles both in strong cross flow and in weak counter flow and the cooling water inside the tubes. Condensing heat exchangers achieve high efficiency by reducing flue-gas temperatures to a level at which most of the water vapor in the flue gas is condensed and the latent heat associated with phase change of the water is recovered. The computer model has been verified by comparison with measured data. To verify the model, heat transfer coefficient was adjusted, along with the mass transfer diffusion coefficient and pressure drop coefficient, to achieve agreement between predicted and measured data. The efficiencies of heat exchanger increase 2.3 ~ 8.1% by condensations of 6.3 ~ 62.6% of the water vapor in the flue gas.

Characteristics of Drag Reduction Additives in the Application of District Cooling System (지역냉방시스템에의 적용을 위한 마찰저항감소 첨가물 특성 연구)

  • 윤석만;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.251-257
    • /
    • 2000
  • District heating and cooling systems offer highly efficient energy utilization and maintenance by centralizing heat management. More pumping power, however, is required because the water has to travel long distance from heat source to the users. In the present study, a trace of drag reduction additives is added to the District Cooling system to achieve a significant drag reduction and save pumping power. Water-soluble polymers, surfactants, and environment-friendly degradable polymers are used as effective drag reducing additives. Time dependent percent drag reductions are compared for various additive solutions at 100 wppm concentration for different water velocity. Without as an anionic surfactant, copolymer was most effective in percent drag reduction. It is found that there exists an optimal condition when copolymer is mixed with SDS. An environment-friendly degradable polymer, xanthan gum, is found to be a significant drag reduction additive. Ice slurry systems, can give less pressure drops compared with chilled water system for certain condtions. Drag reduction additives were also effective for the ice slurry system.

  • PDF