• Title/Summary/Keyword: water-reducing

Search Result 2,779, Processing Time 0.03 seconds

Comparison of Quality Standards of Chemical Admixtures for Concrete between Korea and China (한국과 중국의 콘크리트용 화학 혼화제 품질 규정 비교)

  • Hu, Yun-Yao;Lim, Gun-Su;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.97-98
    • /
    • 2023
  • In this study, comparison of the quality standard of chemical admixtures between Korea and China is conducted. It is classified into three types of water reducing agents: standard, delayed, and accelerated according to the sensitivity and strength improvement of the sensitivity and strength of the agent. However, Chinese standards classify reducing agents only as standard, high efficiency, and high performance, and do not add AE agents into water reducing agent. On the other hand, that of Korea has a classification regulation for reducing agents added with AE agents.

  • PDF

Extraction of Reducing Sugar with Anti-Oxidative Scavengers from Peels of Carya cathayensis Sarg.: Use of Subcritical Water

  • Shimanouchi, Toshinori;Ueno, Shohei;Yang, Wei;Kimura, Yukitaka
    • Environmental Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.41-45
    • /
    • 2014
  • The peels of Carya cathayensis Sarg. (PCCS) were treated under subcritical water conditions ($130^{\circ}C$ to $280^{\circ}C$ for 0 to 120 min). The extract from PCCS included reducing sugar, proteins, and compounds with radical scavenging activity. Addressing the reducing sugar that is a resource of bioethanol, we could maximize the reducing sugar under the subcritical water ($190^{\circ}C$ for 60 min) and obtain 0.24 g/g-sample together with 9.7 units/mg-sample of radical scavenging activity. The obtained extract was estimated to correspond to 1 L of bioethanol/100 g-sample. It was therefore considered that the treatment by subcritical water could yield reducing sugar and natural compounds with radical scavenging activity.

Influence of Chemical Admixture on Bleeding of Concrete (콘크리트의 블리딩에 미치는 혼화제의 영향)

  • 김은호;황인성;손유신;김규용;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.339-342
    • /
    • 2003
  • This study is intended to investigate the influence of chemical admixture on bleeding of concrete. According to the results, the amount of bleeding with elapse of time does not make much difference in the case of naphthalene type water reducing agent(RN), Naphthalene type high performance water reducing agent(HN) and Melamine type high performance water reducing agent(HM), but it is largest in the case of Polycarbonic acid type high performance water reducing agent(HP). Bleeding speed also is highest in the case of HP in comparison with other chemical admixture. This prove that high performance water reducing agent like HP has little effect on fluidity of concrete, but influences the amount of bleeding more greatly, instead. As properties of hardened concrete, compressive strength makes no difference in the case of RN, HN and HM, but on the other hand, it increases in the case of HP due to a decrease of air content and the large amount of bleeding.

  • PDF

Influences of Admixtures on the Properties of Cement Mortars in Floors Using Expansion Agent (팽창재를 사용하는 바닥 모르타르의 특성에 미치는 혼합재료의 영향)

  • 정성철;표대수;송명신;홍상희;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.921-924
    • /
    • 2000
  • The purpose of this paper is to investigate the effects of admixture such as AE water reducing agent and Flyash on properties of cement mortar for floor. As for the effects of AE water reducing agent kinds, fluidity and air content increase in order for melamine type, lignine type and naphtalene type. As Flyash contents increase, fluidity shows high, but air content shows decline tendency. compressive strength according to AE water reducing agent kinds increase in order for melamine type, lignine type and naphtalene type. As AE water reducing agent content increases, it shows to be decreased. As for the effects of Flyash, it retards at early age but at later age it gains high with increase of Flyash contents due to pozzanic reaction. Drying shrinkage shows to be docreased slightly with increase of AE water reducing agent.

Influence of Over-Added AE Water Reducing Agent on Physical Properties of the Concrete (AE 감수제 과다첨가가 콘크리트의 물리적 특성에 미치는 영향)

  • Han, Cheon-Goo;Han, Min-Cheol;Lee, Dong-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.1
    • /
    • pp.91-96
    • /
    • 2008
  • This study is to investigate the influence of the over-added chemical agents, such as water reducing agent(WRA) and AE water reducing agent(AEWRA), on the physical properties of concrete to estimate the degree of damage due to over-added chemical agents. For the fresh concrete, slump and slump flow increased with the increase of WRA and AEWRA as expected. Material segregation phenomenon was observed with the over dosage of lignin based AEWRA about 4 times larger than recommended dosage. The over dosage of AE water reducing agent about 4 times larger than recommended dosage resulted in an increase of air contents remarkably. The set retardation occurred greatly with the increase of AEWRA and WRA. For the properties of the hardened concrete corresponding to the over dosage of AEWRA, it is found that compressive strength of over added AEWRA and WRA concrete are much smaller than those of base and recommended dosage concrete proportionally due to associated increasing air content.

An Experimental Study on the Effect of Cement and High range water reducing AE agent in Fluidity of High Flowing Concrete (고유동콘크리트의 유동특성에 미치는 시멘트 및 고성능 AE감수제의 효과에 관한 연구)

  • 김규용;반성수;박선규;박유신;신홍철;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.63-68
    • /
    • 1998
  • The fluidity of high flowing concrete can be affected by numerous parameters which characterize either the cement of the admixture. The reactivity of a cement as determined by its chemical composition(especially its $C_3$A content), its fineness and its content in sulfates and alkalies obviously plays a key role in rheology of high flowing concrete in fresh state. Specific properties of high range water reducing AE agent used to enhance the workability of high flowing concrete also exert important influence. The purpose of this experimental study is to investigate and analyze the effect of cement and high range water reducing AE agent in fluidity, setting, compressive strength of high flowing concrete. As a result, we found that fluidity of high flowing concrete is affected greatly by kind of cement and high range water reducing AE agent, also, there is harmonic character between high belite cement and polycarbonic acid high range water reducing AE agent.

  • PDF

Analysis of the Possibility of Rapid Quality Appraisal of Water-Reducing Agents Using the Liquid Densimeter and pH Meter (액체 밀도계 및 pH meter기를 이용한 감수제의 신속품질평가 가능성 분석)

  • Kim, Min-Sang;Hyun, Seong-Yong;Baek, Cheol;Jo, Man-Ki;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.210-211
    • /
    • 2017
  • According to KS F 2560, water-reducing agents used when mixing concrete are to undergo quality evaluation testing slump, air contents, setting time, etc., when delivered from the admixture factory to the ready mixed concrete site. Yet in actual acceptance testing this could be substituted by the score report of the admixture company, in which a possibility of low reliability lies. Therefore this study sought to analyze whether by artificially changing the solid content rate of lignin- and naphthalene-based water-reducing agents and using a liquid densimeter evaluate the quality of the admixture. The results showed that the Type B liquid densimeter was most appropriate and 50cc the most appropriate capacity for the mass cylinder. Also, judging from the changes in density and pH according to the changes in solid content rate, it concludes that a rapid appraisal of the quality of lignin- and naphthalene-based water-reducing agents would be possible using a Type B liquid densimeter.

  • PDF

Analysis of aqueous environment iron dissolution in different conditions (조건의 변화에 따른 수중 환경 내에서의 철 용해 분석)

  • Bae, Yeun-Ook;Min, Jee-Eun;Park, Jae-Woo
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.807-810
    • /
    • 2008
  • Permeable reactive barriers containing Zero-valent iron (ZVI) are used to purify ground-water contaminants. One of the representative contaminant is trichloroethylene (TCE). ZVI can act as a reducing agent of TCE. When ZVI is oxidized to Ferric iron, TCE reduced to Ethene, which is non-harmful matter. As a ZVI becomes ferric iron, the reducing effect decreases and iron becomes unavailable. So, constant reduction of TCE requires the regular supply of reducing agent. So, we use Iron-reducing bacteria(IRB) to extend the TCE degrading ability. We perform three experiment DI water, DI water with medium, and DI water with medium and IRB. By the experiment we try to found the dissolve ability.

  • PDF

An Experimental Study on the Engineering Properties of Concrete with Kind of Fine Aggregate and Addition Ratio of Water Reducing Agents (잔골재 종류 및 감소제 첨가율에 따른 콘크리트의 공학적 특성에 관한 실험적 연구)

  • Shin, Kwan-Soo;Na, Chul-Sung;Paek, Yong-Lak;Choi, Se-Jin;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.157-160
    • /
    • 2006
  • Recently, trouble of sand supply is occurred according to exhaustion of natural sand resources. To solve this problem, sea sand and crushed sand are used. But, necessity of water reducing agent because quality of concrete that use sea sand and crushed sand is deteriorated. Therefore in this study was examined on the engineering properties of concrete with kind of fine aggregate and addition ratio of water reducing agents. As a result, compressive strength appeared similar standard regardless of kind of fine aggregate. Compressive strength, durability was similar in decrease of the unit water content by increase of addition ratio of the water reducing agent. Also, drying shrinkage resistivity was improved because the unit water content decreased.

  • PDF

A Fundamental Study on the Development of AE Water Reducing Agent for Reduction of Bleeding (블리딩 저감용 AE감수제 개발에 관한 기초적 연구)

  • 문학용;김한준;김규용;신동인;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.75-78
    • /
    • 2003
  • This study is to investigate the probability to develop the AE Water-reducing agent which can decrease the bleeding by mixing melamine type super-plasticizer(SP) and methyl cellulose(MC) viscosity agent. According to the result, as the mixing ratio of melamine type SP and MC viscosity agent increases, the bleeding is reduced due to a increase of the air content. When the mixing ratio of melamine type SP and MC viscosity agent is 1:2 and 1;3 at the water content of 165kg/$m^3$ and 175kg/$m^3$ respectively, slump and air content are satisfied and bleeding is reduced to some extent, so this is determined as the mixing ratio of AE water reducing agent for reduction of bleeding. It is prove that the developed AE water reducing agent for reduction of bleeding can reduce the amount of bleeding and prohibit the plastic shrinkage crack by slowing down the bleeding speed. Compressive strength of hardened concrete does not make any difference in comparison with plain concrete.

  • PDF