• Title/Summary/Keyword: water-energy

Search Result 9,149, Processing Time 0.034 seconds

A Fundamental Study on Sea Water Freezing Behavior in a Rectangular Vessel Cooled from Below (구형용기의 하부면 냉각에 의한 해수 동결거동의 기초적 연구)

  • 김명준;길병래;김명환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.5
    • /
    • pp.564-570
    • /
    • 1997
  • The most important factor for the desalination system is the fresh water production cost dependent upon the possible energy source which should be obtained easily and with low price. Recently in Korea the demand of LNG, as a cheap and clean energy which does not cause an environmental problem, has sharply been increased. In general, LNG is storaged in a tank as a liquid state below -162 'C. When it is serviced, however, the LNG absorbs energy from a heating source and transforms to the gaseous state with high pressure. During this process a huge amount of cold energy accumulated in LNG is wasted. This waste cold energy can be utilized for producing fresh water from sea water using a sea water freezing desalination system. In order to develop a sea water freezing desalination system and to establish its design technique, a qualitative and quantitative data regarding the freezing behavior of sea water is needed in advance. The goal of this study, therefore, are to reveal the freezing mechanism of sea water, to measure the freezing rate, and to investigate the freezing heat-transfer characteristics. The experimental results help to provide a general understanding of the sea water freezing behavior in a Rectangular vessel cooled from below.

  • PDF

Energy-Saving and Environmental Evaluation of Water Supply System on Replacing Water Storage Installed Booster Pump System by Direct Connecting Booster Pump System (저수조 설치 펌프직송방식의 수도직결 증압방식 전환에 관한 에너지절약성 및 환경성 검토)

  • Lee, Chulgoo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.3
    • /
    • pp.7-12
    • /
    • 2015
  • Currently water supply system with water storage is generally applied except for small building such as single-family houses, and water supply system on replacing water storage installed system by direct connecting system has been increasing because of sanitary and energy-saving aspects. The purpose of this study is to evaluate energy-saving and environmental efficiency of direct connecting booster pump system in comparison with the water storage installed system. The architectural condition of the evaluation subject is ten-story apartment house in which sixty households live. To calculate the power consumption of the pump, the volume of water supply was determined from existing data and other data, such as head, efficiency of the pump, was the value used for general application in design office. The power consumption of the water supply pump for one day was 8.5 kWh for direct connecting booster pump system, and 22.5 kWh for water storage installed system, and the former system showed energy savings of 62% compared to the latter system. Reduced power consumption also leads to reduction of $CO_2$ emission. According to the criteria presented in the Korea Energy Management Corporation, reducing the 2,410 kg $CO_2$ emission is possible per year.

Effect of Glucose-Sweetened Drinks on Blood Glucose, Energy, and Water Intake at a Meal 3h Later in Healthy Males

  • Kim, Seok-Young
    • Nutritional Sciences
    • /
    • v.9 no.4
    • /
    • pp.280-287
    • /
    • 2006
  • The aims of this study were to describe the effects of glucose-sweetened drinks on blood glucose, energy, and water intake at a meal 3 hours later. The effect of blood glucose on prandial energy intake and the relationship between water and energy intake during a meal were also determined. Twenty healthy normal-weight men were fed pizza test meals 3h after consuming four drinks of 0, 50g, 65g, and 75g glucose in random order, within-subjects design. Blood samples were measured at baseline and every 30 min after ingestion of drinks and 30min after the end of the test meal and the appetite was also assessed by visual analog test at the same interval. The results of this study showed that various glucose drinks altered blood glucose responses compared with that of water control(p<0.0001). Blood glucose areas under the curve(AUC) for glucose-sweetened drinks were significantly(p<0.05) higher than that for the control over 3 hours after a drink and 30 min after the test meal. Consumption of the glucose-sweetened drinks significantly increased(p<0.05) energy and water intake at a test meal compared with the water control, except the drink containing 75g glucose. For all drinks combined, the energy intake was negatively correlated with the blood glucose and positively correlated with the volume of water consumed at a test meal at 3 hours later.

Experimental Study on Thermal Performance of Palte-type Fresh Water Generator for applying Solar Energy Desalination System (태양에너지 해수담수화시스템에의 적용을 위한 판형 해수담수기의 열성능에 관한 실험적 연구)

  • Kim, Jeong-Bae;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.35-41
    • /
    • 2007
  • To demonstrate the desalination system, the demo-plant was scheduled to be installed. The system was planned to use solar thermal collector as heat source and PV as electricity source. For the design of the desalination demonstration system, firstly the solar thermal system would be well designed from the result between the supplied heat into the fresh water generator and the fresh water yield. The generator for demonstration system was chosen as the fresh water generator of the single stage and effect with plate-type heat exchanger using low pressure evaporation method. The test facility for the tests to reveal the relationship between the fresh water yield and the supplied heat flow rate was designed and manufactured. The maximum fresh water yield of two fresh water generators applied in this study was designed as 1.5 Ton/day. The parameters relating with the performance of fresh water generator are known as sea water inlet temperature, hot water inlet temperature, and hot water flow rate. Through the experiments, this study firstly showed detail operation characteristics of the generator and designed the solar thermal system for the demonstration system.

An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental Apartment (도심(都心) 임대(賃貸)아파트의 에너지 및 상수(上水) 소비(消費) 특성(特性) 분석(分析))

  • Seo, Youn-Kyu;Kim, Joo-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.261-265
    • /
    • 2008
  • To solve the lack of housing, our country has supplied an enormous volume of apartments, and these days it occupies 75% of our buildings. As apartments occupy most of our housings, the rate of energy usage from them are also high. On this, setting apartment energy reduction as a target, by researching the actual conditions of energy consumption and drawing a basis data, we can apply this as a way of saving energy, rationalization of the scale of energy supply facilities and a standard when planning facilities. To grasp the present condition of energy usage of the urban rental apartment, this research analysed the use of electricity, gas and water monthly and annually of a rental apartment that is located in Daegu. The results showed that in 2003 the electricity usage was 1,198MWh but 1,315MWh in 2007, which means 9% of electricity usage increases every year. The average of water usage was $85,072m^2$ per year and they used $604.2MJ/m^2$ Typical energy consumption unit on $74.4m^2$ of area and $448.8MJ/m^2$ on $105.8m^2$. By showing the usage of energy and water of the urban rental apartment, understanding the tendency and preparing an Typical energy consumption unit standard through this research, apartments should use energy more efficiently.

  • PDF

Application for Heating and Cooling System Using Sewage Water (100RT급 하수열원 냉난방시스템 적용)

  • Chang, Ki-Chang;Yoon, Hyung-Kee;Park, Seong-Ryong;Baik, Young-Jin;Ra, Ho-Sang;Shin, Kwang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.215-220
    • /
    • 2006
  • Along with socioeconomic development and improving standard of living, the heat demand for heating and cooling in residential and commercial sectors is expected to expand rapidly, reaching over 43 million TOE by 2010 in Korea(about 80% increase compared with that in 1995). Since most of this heat demand is loop temperature below $60^{\circ}C$, the utilization of 'unused energy' is surely one of very effective measures to both environmental preservation and energy conservation. 'Unused energy' in this paper is implicated as 'temperature differential energy' available from treated sewage water, useful and abundant heat source for heat pump(cooler in summer and warmer in winter than outside air). An analysis was carried out to estimate the energy potential of treated sewage water for heat pump heat source. Some analysis were taken to study the characteristics of a heat pump system using the treated sewage water as heat source.

  • PDF

Recent Advances in Catalyst Materials for PEM Water Electrolysis

  • Paula Marielle Ababao;Ilwhan Oh
    • Journal of the Korean Electrochemical Society
    • /
    • v.26 no.2
    • /
    • pp.19-34
    • /
    • 2023
  • Due to the intermittency of renewable energy sources, a need to store and transport energy will increase. Hydrogen production through water electrolysis will provide an excellent way to supplement the intermittency of renewable energy sources. While alkaline water electrolysis is currently the most mature technology, it has drawbacks of low current density, large footprint, gas crossover, etc. The PEM water electrolysis has potential to replace the alkaline electrolysis. However, expensive catalyst material used in the PEM electrolysis has been the bottleneck of widespread use. In this review, we have reviewed recent efforts to reduce catalyst loading in PEM water electrolysis. In core-shell nanostructures, the precious metal catalyst forms a shell while heteroatoms form a core. In this way, the catalyst loading can be significantly reduced while maintaining the catalytic activity. In another approach, a corrosion-resistant support is utilized, which provides a stable platform to impregnate precious metal catalyst.

A study on the irrigation water pumping system of multipurpose dams by the large water ejector (대형 수이젝터를 이용한 다목적댐 관개용수 펌핑시스템에 관한 연구)

  • 윤석훈;오철;손근홍;김철환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.73-80
    • /
    • 1994
  • The water ejector is a low pressure high flow rate volumetric pump. It utilize the energy of a low mass flow, high velocity stream to induce a large mass flow, low velocity stream. In addition, it has a very good resistances to cavitation compared to the other type of pumps, and the maintenance cost is practically nil. There has been enormous energy loss to supply the upper part water of dam which has large potential energy as mere irrigation water in domestic multipurpose dam. The new type of energy saving system which developed through the present study can economizes over 950,000 kWh per year by mixing the upper part water of dam with the waste water by the large water ejector. This paper estimates the economical efficiency of the new type of irrigation water pumping system, and further more, represents the change of performance characteristics of large water ejector, which was adapted to this system, according to the fluctuation of upper water level that seasonally changes.

  • PDF

Hydrogen Generation by Electrical Discharge Through Metal / Water System

  • Park, Yong-Man;Kang, Goo-Jin;Cha, Suk-Yal;Lee, Woong-Moo
    • Journal of Energy Engineering
    • /
    • v.5 no.2
    • /
    • pp.198-202
    • /
    • 1996
  • Reactive metals like aluminum generate hydrogen gas when it reacts with water. Aluminum, despite its high chemical affinity with water, cannot continue the reaction due to the passive oxide layers formed on its surface. When the reaction is assisted by electrical energy dissipation in the form of discharge, the reaction is more likely to be sustained. In this report, some preliminary experimental results are presented regarding the hydrogen generation based on this scheme.

  • PDF

Compensation for Photovoltaic Generation Fluctuation by Use of Pump System with Consideration for Water Demand

  • Imanaka, Masaki;Sasamoto, Hideki;Baba, Jumpei;Higa, Naoto;Shimabuku, Masanori;Kamizato, Ryota
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1304-1310
    • /
    • 2015
  • In remote islands, due to expense of existing generation systems, installation of photovoltaic cells (PVs) and wind turbines has a chance of reducing generation costs. However, in island power systems, even short-term power fluctuations change the frequency of grids because of their small inertia constant. In order to compensate power fluctuations, the authors proposed the power consumption control of pumps which send water to tanks. The power control doesn’t affect water users’ convenience as long as tanks hold water. Based on experimental characteristics of a pump system, this paper shows methods to determine reference power consumption of the system with compensation for short-term PV fluctuations while satisfying water demand. One method uses a PI controller and the other method calculates reference power consumption from water flow reference. Simulations with a PV and a pump system are carried out to find optimum parameters and to compare the methods. Results show that both PI control method and water flow calculation method are useful for satisfying the water demand constraint. The water demand constraint has a little impact to suppression of the short-term power fluctuation in this condition.