• 제목/요약/키워드: water usage

검색결과 741건 처리시간 0.033초

A Study on Characteristics of Under Registration Rate for Water Meters to Increase the Accounted Water Rate (유수율 향상을 위한 수도미터의 불감률 특성 연구)

  • Lee, Dong-Keun;Park, Jong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제34권8호
    • /
    • pp.791-797
    • /
    • 2010
  • The reliability of a water meter for measuring the water flow-rate and subsequent analysis of the measured water depends on the accuracy of measurement. The under registration of a water meter causes many problems for operators, such as loss in revenue and a decrease in the rate of measured water. The purpose of this study is to support and development core technology, such as efficient operations management and adoption of the best mechanism for providing different services by experimentally. In this study, experiments were conducted using water meters with different diameters, manufacturers, years of usage and the specific uses. On the basis of the results, the water meter confirmed that the error of minimum flow rate which will use long becomes larger more in the direction of minus.

Estimating Visitors on Water-friendly Space in the River Using Mobile Big Data and UAV (통신 빅데이터와 무인기 영상을 활용한 하천 친수지구 이용객 추정)

  • Kim, Seo Jun;Kim, Chang Sung;Kim, Ji Sung
    • Ecology and Resilient Infrastructure
    • /
    • 제6권4호
    • /
    • pp.250-257
    • /
    • 2019
  • Recently, 357 water-friendly space were established near the main streams of the country through the Four Major Rivers Project, which was used as a resting and leisure space for the citizens, and the river environment and ecological health were improved. We are working hard to reduce the number of points and plan and manage the water-friendly space. In particular, attempts are being made to utilize mobile big data to make more scientific and systematic research on the number of users. However, when using mobile big data compared to the existing method of conducting field surveys, it is possible to easily identify spatial user movement patterns, but it is different from the actual amount of use, so various verifications are required to solve this problem. Therefore, this study evaluated the accuracy of estimating the number of users using mobile big data by comparing the number of visitors using mobile big data and the number of visitors using drone for Samrak ecological park located in the mouth of Nakdong River. As a result, in the river hydrophilic district, it was difficult to accurately estimating the usage pattern of each facility due to the low precision of pCELL, and it was confirmed that the usage patterns in the park could be distorted due to the signals stopped at roads and parking lots. Therefore, it is necessary to improve the number of pCELLs in the water-friendly space and to estimate the number of visitors excluding facilities such as roads and parking lots in future mobile big data processing.

Corrosion Level of RC Concrete Specimen Intermittently Attacked by Sea Water (해수간헐침투되는 철근콘크리트의 부식도 평가)

  • 정철희;정영수;최응규;원종필
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.207-212
    • /
    • 1996
  • Recently, massive concrete structures exposed to salt from ocean marine environments, or from winter deicing. The corrosion caused by chloride-penetration may affect severey the durability and service life of such a concretestructures. Thus, it is necessary to develop durable concrete to enhance the corrosion resistance. In this study, we investigate the usage of adequate corrosion-protection materials in order to reduce permability-coefficient of concrete and method of enhancing the durability of concrete structures using by penetrating corrosion-protection materials.

  • PDF

Preparation and Properties of Water Vapor Permeable Waterborne Polyurethane -Effect of Polyol- (투습성 수분산 폴리우레탄의 제조와 특성 - 폴리올의 영향 -)

  • Sang-Woo Park;Myung-Hwan Lee;Young-Hee Lee;Han-Do Kim
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 한국섬유공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.5-8
    • /
    • 2001
  • Waterborne Polyurethane dispersions continue to show growth in commercial usage due to the ever increasing environmental legislation to reduce VOC in Coating and adhesive materials. The transition from solvent-based to waterborne Polyurethane(WPu) has also been facilitated by advances in both the chemistry and technology employed and the formulation expertise required. (omitted)

  • PDF

USING MULTIVARIATE DATA ANALYSIS FOR PROCESS TROUBLE SHOOTING

  • Winchell, Patricia
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 한국펄프종이공학회 2006년도 PAN PACIFIC CONFERENCE vol.2
    • /
    • pp.191-195
    • /
    • 2006
  • Multivariate data analysis tools were used to improve the understanding of the wet end chemistry and white water system of the Papermill at NorskeCanada Crofton Division. Specifically, the analysis was aimed at identifying what variables were contributing to increased retention aid use and wet end instability. Several models were developed using data sets with up to 88 process variables and over 3000 observations. It was found that increased retention aid use was driven primarily by PCC and TMP usage as well as the addition of Alaskan White Spruce to the TMP furnish.

  • PDF

Smart Irrigation and Temperature Control for a Greenhouse System

  • Abinaya P;Swathika P
    • International Journal of Computer Science & Network Security
    • /
    • 제24권1호
    • /
    • pp.151-155
    • /
    • 2024
  • This project is designed with the aim to facilitate the farmer or gardener to engage in green house systems and to improve agricultural technology. In order to reduce continuous monitoring of the soil parameters, excess time consumption for the farmers and excessive usage of water, "Smart irrigation and temperature control for a greenhouse system" has been developed. There are two different ways to irrigate the land namely traditional irrigation methods and modern irrigation methods.

Impact Evaluation of Water Footprint on Stages of Drainage Works (배수공 각 작업 단계별 물발자국 영향평가)

  • Chen, Di;Kim, Joon-Soo;Batagalle, Vinuri;Kim, Byung-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제40권2호
    • /
    • pp.225-231
    • /
    • 2020
  • Fresh water that can be used by a person of the total amount of water on the planet is increased because it is less than 0.01 % except underground water, ice and snow, etc. water management response need. In order to protect and efficiently utilize water resources, major countries are conducting water footprint studies that can quantitatively estimate the amount of water put into the operating phase of the resource harvesting phase, mainly agriculture. Korea has also recently developed a number of policies in order to cope with water shortages, and in the construction industry, as well as the need for basic research to support it has been emphasized. This study was constructed DB up to the raw material harvesting step, the transport step, the production stage in order to estimate the water consumption of resources to be put into the work process to target the drainage of the road. Water usage estimation method was utilized the method presented in the Water Footprint Manual and the environmental score card certification guide, unit water usage each drainage main method was calculated after estimating the water footprint considering the water character factor, indirect water and the direct water, the water consumption factor of material input to each process. Brown asphalt, rebar, remicon of the drainage material as a result of the water footprint calculation accounted for 97 % of the total. Drainage method is a culvert, a side channel, a culvert wing wall, reinforced concrete open channel accounted for 92.2 % of the total. Drainage total step-by-step calculated water consumption and water footprint was found in order of raw material harvesting step, transport stage, production stage. Water footprint each drainage method or total drainage material calculated in this study can be used as a base data in the agricultural and construction sectors. In order to increase the reliability of the analysis, it is believed that further overseas databases will be needed for continuous review and research.

LS-SVM Based Modeling of Winter Time Apartment Hot Water Supply Load in District Heating System (지역난방 동절기 공동주택 온수급탕부하의 LS-SVM 기반 모델링)

  • Park, Young Chil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제28권9호
    • /
    • pp.355-360
    • /
    • 2016
  • Continuing to the modeling of heating load, this paper, as the second part of consecutive works, presents LS-SVM (least square support vector machine) based model of winter time apartment hot water supply load in a district heating system, so as to be used in prediction of heating energy usage. Similar, but more severely, to heating load, hot water supply load varies in highly nonlinear manner. Such nonlinearity makes analytical model of it hardly exist in the literatures. LS-SVM is known as a good modeling tool for the system, especially for the nonlinear system depended by many independent factors. We collect 26,208 data of hot water supply load over a 13-week period in winter time, from 12 heat exchangers in seven different apartments. Then part of the collected data were used to construct LS-SVM based model and the rest of those were used to test the formed model accuracy. In modeling, we first constructed the model of district heating system's hot water supply load, using the unit heating area's hot water supply load of seven apartments. Such model will be used to estimate the total hot water supply load of which the district heating system needs to provide. Then the individual apartment hot water supply load model is also formed, which can be used to predict and to control the energy consumption of the individual apartment. The results obtained show that the total hot water supply load, which will be provided by the district heating system in winter time, can be predicted within 10% in MAPE (mean absolute percentage error). Also the individual apartment models can predict the individual apartment energy consumption for hot water supply load within 10% ~ 20% in MAPE.

Prediction of Cryptosporidium parvum Inactivation in Advanced Ozone Drinking Water Treatment with Lab Scale Experiments (실험실 규모 크립토스포리디움의 불활성화 실험을 통한 오존 고도정수처리 정수장에서 소독 효과 예측)

  • Cho, Min;Chung, Hyenmi;Kim, Reeho;Shon, Jinsik;Park, Sangjung;Yoon, Jeyong
    • Journal of Korean Society on Water Environment
    • /
    • 제21권1호
    • /
    • pp.7-13
    • /
    • 2005
  • With the appearance of pathogenic microorganisms, which were resistant to free chlorine, the significant attention to the necessity of powerful alternative disinfection methods such as ozone, chlorine dioxide, LTV irradiation to inactivating pathogens has been increased in water treatment. Among these alternative disinfection methods, ozone is well known as strong biocidal method and the usage of ozone is also increasing in Korea. However, in Korea, there has been no report on the quantitative study of Cryptosporidium parvum with ozone and its evaluation in advanced drinking water treatments. This study reports on the methodology for predicting the ozone inactivation of Cryptosporidium parvum by ozone disinfection in advanced drinking water treatment. The method is based on the fact that a specific inactivation level of microorganisms is achieved at a unique value of ozone exposures, independent of ozone dose and type of water, and quantitatively described by a delayed Chick-Watson model. The required values ${\bar{C}}T$ for 2 log inactivation of Cryptosporidium parvum was $6.0mg/L{\cdot}min$ and $15.5mg/L{\cdot}min$ at $20^{\circ}C$ and $5^{\circ}C$, respectively. From this obtained Cryptosporidium parvum inactivation curves and calculated ${\bar{C}}T$ values of advanced drinking water treatment water in Korea with FIA (Flow injection alaysis), we can predict that water treatment plant can achieve a 1.1~1.8 log inactivation and 0~0.4 log inactivation at $20^{\circ}C$ and $5^{\circ}C$, respectively. This methodology will be useful for drinking water treatment plants which intend to evaluate the disinfection efficiencies of their ozonation process without full scale test and direct experiments with Cryptosporidium parvum.

A Study on the Introduction of RO Facility for Jeju Samyang Water Source (제주도 삼양 수원지 RO 시설 도입 연구)

  • Kim, Woochan;Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제29권6호
    • /
    • pp.601-608
    • /
    • 2015
  • Pollutants removal efficiency in pretreatment(GAC filter, multi-media filter, disk filter) and RO facilities was investigated for the Jeju Samyang spring water source where raw water intake has been stopped due to sea water intrusion. In addition, preliminary feasibility analysis was conducted between RO and groundwater intake systems. Turbidity removal in 4 different pretreatment processes was less than 25% due to low concentration of turbidity(i.e., less than 0.21 NTU), while multi-media filter is recommended for the pretreatment facility based on the low organic content in raw water as well as cheaper operation and maintenance cost. The average concentration of $Cl^-$ in raw water was 691.4 mg/L, while that of RO permeate was 9.1 mg/L(i.e., removal efficiency was 98.4%). In addition, TDS removal efficiency was 98.1%, which was quite high. The production cost for RO system($Q=4,000m^3/d$) was $362.1won/m^3$ considering installation, operation and maintenance cost for 30 years. While that of groundwater was $262.6won/m^3$ which was low compared to the RO system. However, it is recommended to introduce RO system for Samyang water source rather than new groundwater development because Samyang water source has been discharged to the sea without any usage, while groundwater can be used for other purpose as a sustainable water source.