• Title/Summary/Keyword: water usage

Search Result 739, Processing Time 0.032 seconds

Sole and Combined Usage of Ultra-sonication and Hydrogen Peroxide as Mitigation Techniques of Bio-fouling

  • Haque, Md. Niamul;Kwon, Sung-hyun
    • Journal of Environmental Science International
    • /
    • v.25 no.10
    • /
    • pp.1397-1405
    • /
    • 2016
  • Mussels are stubborn organism attached to solid substrate by byssus threads and caused operational problems in utility of power generating stations. Sole and combined usage of ultrasonic (28 kHz- and 42 kHz- frequencies) and hydrogen peroxide ($H_2O_2$) has studied for control of blue mussel larvae and adult stage in seawater condition. A theoretical wo rking model using disinfection (Chick and Watson type) approaches is presented based on helpful results of experiments. This study also demonstrate that the combined treatment (ultra-sonication with $H_2O_2$) is overall highly efficient than individual treatment would, but on the basis of exposure time, the ultra-sonication was the most efficient among them. Therefore the development of sole and combined technique might be effective practical mitigation strategy against mussel attachment for water handling facilities.

Feasibility study on district heating Magok area by sewage water heat source (마곡지구 하수열에너지이용 타당성 검토)

  • Lee, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.357-362
    • /
    • 2009
  • As a unutilized energy, treated sewage water locates widespread near urban areas. From the previous survey, the sewage water is reported to hold energy potential up to 36,000 Tcal/year, which was 2.1% of the total domestic energy consumption and 9.7% of the energy usage in the household and business sector in 2006. Temperature of the sewage water differs locally, but its range is observed in a range of $20{\sim}25^{\circ}C$ in summer and $8{\sim}13^{\circ}C$ in winter. Since the temperature range of the sewage water has a better seasonal distribution about $5{\sim}10^{\circ}C$ compared to ambient air, it is a promising heat sink for summer or heat source for winter. The sewage water is also a high quality heat source from its abundant quantity and uniform temperature. Considering the ambient temperature of Korea is very low in winter, a heat pump system using the sewage water can be an alternative to prevent problems of capacity deficiency and frost formation.

  • PDF

Development of 1-Dimensional Water Quality Model Automatizing Calibration-Correction and Application in Nakdong River (1차원 수질 예측 모형의 검보정 자동화 시스템 개발 및 낙동강에서의 적용)

  • Son, Ah Long;Han, Kun Yeun;Park, Kyung Ok;Kim, Byung Hyun
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.5
    • /
    • pp.765-777
    • /
    • 2011
  • According to the total pollution load management system, exact prediction and analysis of water quality and discharge has been required in order to allocate the amount of pollution load to each local government. In this study, QUAL2E model was used for comparison with other water quality models and improve the inadequate to forecast future water quality. And Various calibration and verification methods were applied to deal with existing uncertainties of parameter during modeling water quality. For user convenience, A GUI(Graphical User Interface) system named "QL2-XP" model is developed by object-oriented language for the user convenience and practical usage. Suggested GUI system consist of hydraulic analysis, water quality analysis, optimized model calibration processes, and postprocessing the simulation results. Therefore this model will be effectively utilized to manage practical and efficient water quality.

Adsorption Characteristics for Nitrosamines in Granular Activated Carbon Process (입상활성탄 공정에서의 nitrosamine류 흡착 특성)

  • Kim, Kyung-A;Son, Hee-Jong;Lee, Sang-Won;Bin, Jae-Hoon;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.10
    • /
    • pp.709-714
    • /
    • 2012
  • This study accessed the adsorption characteristics of the nine nitrosamine species on coal-based granular activated carbon (GAC). The breakthrough appeared first for NDMA and sequentially for NMOR, NPYR, NMEA, NDPA, NDEA, and NPIP. On the other hand, NDBA and NDPHA were not detected in the treated effluent for the operation period. The maximum adsorption capacity (X/M) for the seven nitrosamine species with apparent breakthrough points ranged from $27.5{\mu}g/g$ (for NDMA) to $671.0{\mu}g/g$ (for NPIP). Carbon usage rate (CUR) for NDMA was 1.07 g/day, 13.4 times higher than that for NPIP (0.08 g/day). The X/M values for the seven nitrosamine species were fitted well with a linear regression ($r^2$ = 0.94) by their octanol-water partitioning coefficient ($K_{ow}$).

An Analysis of Relationship between Carbon Emission and Urban Spatial Patterns (도시패턴과 탄소배출량의 관계 분석)

  • Kim, In-Hyun;Oh, Kyu-Shik;Jung, Seung-Hyun
    • Spatial Information Research
    • /
    • v.19 no.1
    • /
    • pp.61-72
    • /
    • 2011
  • Greenhouses gas emission due to usage of fossil fuel has been known as one of the main causes of global warming. Fundamentally, greenhouse gas is a by-product of economic activity. Since majority of economic activity happens in an urban setting, a countermeasure in an urban setting is needed. Therefore, an analysis of relationship between carbon dioxide emission and urban form will be investigated for urban planning and management in the future. The purpose of this study is to analyze the relationship between carbon dioxide emission and urban spatial patterns, and suggesting an urban form with low carbon dioxide emission. In order to achieve this, first theoretical analysis was carried out on urban spatial patterns related to physical size, usage rate, and activity level. Secondly, Seoul's dam on electricity, natural gas, local heating, petroleum, and water usage and mapping a carbon dioxide emission map. Thirdly, relationship between carbon dioxide emission and urban spatial patterns are analyzed and urban spatial patterns that affects energy usage in urban setting was elucidated, and elicited implications on future directions on urban planning based on our analyses above.

Studies on Combined Usage of Combined Preparation of Crude Drugs and Anti-neoplastic Drugs(II) -Alleviative effect of cis-Platin and Mitomycin C through Combined Usage of Gamidaebo-Tang- (생약복합제제(生藥複合製劑)와 항암제(抗癌劑)의 병용투여(倂用投與)에 관한 연구(硏究) (제2보)(第2報) -cis-Platin 및 Mitomycin C와 가미대보탕(加味大補湯)의 병용투여(倂用投與)에 의한 부작용(副作用) 경감(輕減) 효과-)

  • Hong, Nam-Doo;Kim, Jong-Woo;Kim, Nam-Jae;Kim, Jin-Sik
    • Korean Journal of Pharmacognosy
    • /
    • v.23 no.2
    • /
    • pp.89-95
    • /
    • 1992
  • The water extract of Gamidaebo-Tang depressed the lethal toxicity of cis-platin$(45{\mu}M/kg,\;s.c.)$, and mitomycin C (6mg/kg, s.c.). Significant depression of renal toxicity(indicated by an increased blood urea nitrogen value and creatinine value) of cis-platin $(35{\mu}M/kg)\;s.c.)$, was observed in mice treated with Gamidaebo-Tang. In rats treated with mitomycin C and Gamidaebo-Tang, the increased LDH activity and reduced total protein and albumin contents by mitomycin C were significantly depressed. The number of WBC was significantly increased in rats treated with mitomycin C but in the rats treated with mitomycin C and Gamidaebo-Tang, the number of WBC was increased and the hematocrit value and the number of RBC and Hgb were significantly increased in the dose-dependent manner. Therefore, bone marrow toxicity of mitomycin C in the rats treated with Gamidaebo-Tang was depressed. In the end, alleviative effects of the side actions of cis-platin and mitomycin C were acknowledged by combined usage of Gamidaebo-Tang and these anti-neoplastic drugs.

  • PDF

An Experimental Study on the Solar Hot Water Heating System for the Dormitory of University (기숙사 태양열 급탕시스템의 열성능에 관한 실증연구)

  • Shin, U-Cheul;Baek, Nam-Choon;Kwak, Hee-Yeul;Ju, Hyunlo-Lo
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.2
    • /
    • pp.103-109
    • /
    • 2006
  • The Purpose of this work is to investigate a long-term thermal performance of active solar hot water heating system for the dormitory of university. For this, monitering system including temperature sensors, flow-meters was installed in this system. Measurement was continued for 13 months between April 1st 2004 and May 31th 2005. As results, hot water demand, daily and monthly hot water load distribution which are necessary for the solar system design were suggested. Also thermal stratification in solar buffer tank was observed in the point of increasement of system efficiency. The yearly solar fraction and system efficiency of this system are about 29.5% and 44.9% respectively.

A Study on the Optimal Use of Silent Discharge Type Ozonizer in Purification Plant (정수장의 무성방전형 오존발생기 최적활용방안에 관한 연구)

  • Shin, Hong-Sub;Park, Hyun-Mi;Kwon, Young-Hak;Song, Hyun-Gig;Park, Won-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.54-60
    • /
    • 2015
  • There are 5 purification plants with the adopted advanced water purification treatment process in Korea. Annual operating costs were 8,990 million won including purchase cost of oxygen and power usage charges. We need research to optimize, in the future, when considering the direction of domestic water treatment continues to adopt advanced water treatment process. In this paper, calculate the optimal operating costs by injected the oxygen gas, used power cost. approximately 25% of the operating costs can be reduced when injected the ozone gas is 1.0ppm than 2.0ppm, the necessary amount of oxygen is increased then power is lower. so operating costs are decided according to oxygen costs. On the other hand, high ozone concentration 2.0ppm, the necessary power is increased then amount of oxygen is lower. Therefore, in the case of G purification plant, the controlling factor of the input ozone concentration 2ppm, PID control operation by setting the concentration of over 10Wt% is efficient. The installed capacity is the more little the more better when considering on Ozone injection rate in the process of water treatment.

The Development of Monitoring System for Performance Evaluation of Solar Hot Water Heater (태양열 온수기 성능평가 위한 모니터링 시스템 개발)

  • Kim, Jae-Yeol;Choi, Seung-Hyun;Yang, Dong-Jo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.417-417
    • /
    • 2009
  • The application of solar energy, in the field of alternative energy, was on the increase tendency. In the case of advanced nations, through continuous R&D, solar hot water heater with high efficiency has been used for the house and the industrial process on business, advanced nations were reached up the experimental stage of solar generation system. But, the actual circumstance of the domestic has been not accomplished the popularization of solar hot water heater and the settlement of it which is the fundamental stage of the solar energy usage. This trouble, the domestic was flooded with small enterprise for producing solar hot water heater, was caused by the popularization and the production without verification of performance. To supply the monitoring program for evaluating solar hot water heater, this research was purpose to improve the technical development of the enterprise for producing solar-heat hot-water-boiler and served as an aid for the enlargement and the popularization on solar energy.

  • PDF

A Study on the Application of AI-Based Composite Sensor in WTP (수도사업장에서의 AI 기반 복합센서 적용 방안 연구)

  • Hong, Sung-taek;An, Sang-byung;Kim, Kuk-il;Cho, Hyun-sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.41-42
    • /
    • 2021
  • The Green New Deal policy was established to innovate the government's energy consumption structure, establish a third basic energy plan to strengthen the global competitiveness of the energy industry, and realize a carbon neutral society due to the increased need for transition to a low-carbon economy. Waterworks such as drinking water, water purification plant, and pressurization plant analyze control factors and energy consumption status by process to improve energy management efficiency and reduce energy usage through the 4th industrial revolution. Ultimately, we want to realize net-zero water purification plant.

  • PDF