• 제목/요약/키워드: water treatment process

검색결과 2,490건 처리시간 0.032초

공공하수처리시설 공법 선정을 위한 계층화분석법 적용방안 고찰 (A study on AHP application of selection method for the best treatment technology of public sewage treatment works)

  • 정동환;조양석;안경희;최인철;정현미;이재관
    • 상하수도학회지
    • /
    • 제30권4호
    • /
    • pp.427-440
    • /
    • 2016
  • Various kinds of processes are used in the Public Sewage Treatment Works(PSTWs) in order to achieve water quality criteria and TMDL in the watershed. The performance of the existing processes at PSTWs depends on influent characteristics, effluent quality target, amount of sludge production, power cost and other factors. In present, the Selection Guideline for the Available Treatment Process of PSTWs is used for a process decision in the country. But there are some problems regarding redundancy of assessment factors and complexity of assessment procedure in the guideline. In this study, we did a test application of AHP for process selection of PSTWs, which propose is to simplify assessment factors such as pollutant removal amount, sludge generation, electricity consumption, stability of operation, convenience of maintenance, easiness of existing process application, installation cost, and operating cost concerning of environmental factors, technical factors and economical factors. According to the study, the PSTWs selection procedure guideline can be improved using application of AHP method.

도시발생 폐기물을 저공해 열처리 생산한 환경친화형 인공배지의 작물재배이용기법 개발 (Development of Crop Cultivation Technique Using Environment-friendly Artificial Media Using Urban Waste)

  • 김선주;양용석
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.490-499
    • /
    • 1998
  • This study was initiated to investigate the applicability of sludge from water or waste water treatment on the crop cultivation. Sludge is generated in the process of water and wastewater treatment process in large quantity. The sludge can cause many environmental problems. we have a many available treatment methods of sludge However, these methods still shortcomings and are not. The composition of typical municipal sludge contains organics and inorganics. The organics components are normally burnt in high temperature and mainly inorganics components are left after thermal treatment process. For the production of artificial media, chabazite was used as additive, and the mixed material was thermally treated in the firing kiln at 800~1,10$0^{\circ}C$ for about 10 minutes. The physical and chemical characteristics of artificial media were analyzed and it showed that the artificial media could be used as a media for plants and soil conditioner for farmland. The concentrations of the toxic heavy metals in the media were lower then those in the soil quality standard for farmland. This study illustrated that the artificial media production process, and introduced how to produce it's possible application as a media for Plant growth.

  • PDF

전기화학적 처리에 의한 배추 절임염수 재이용 가능성 평가 (Evaluation of brine reuse on salting of chinese cabbage using electrochemical process)

  • 정희숙;이은실;한성국;한응수
    • 상하수도학회지
    • /
    • 제28권5호
    • /
    • pp.541-548
    • /
    • 2014
  • The pickling brine generated from the salting process of kimchi production is difficult to treat biologically due to very high content of salt. When pickling brine is treated and discharged, it cannot satisfy the criteria for effluent water quality in clean areas, while resources such as the salt to be recycled and the industrial water are wasted. However, sterilization by ozone, UV and photocatalyst is expensive installation costs and operating costs when considering the small kimchi manufacturers. Therefore there is a need to develop economical process. The study was conducted on the sterilization efficiency of the pickling brine using electrochemical processing. The electrochemical treatment of organic matters has advantages over conventional methods such as active carbon absorption process, chemical oxidation, and biological treatment because the response speed is faster and it does not require expensive, harmful oxidizing agents. This study were performed to examine the possibility of electrochemical treatment for the efficient processing of pickling brine and evaluated the performance of residual chlorine for the microbial sterilization.

하수처리시설에서 인 고도처리를 위한 일체형 침전부상공정(SeDAF)의 응집제 주입농도 자동제어기법 검토 (Automatic control of coagulant dosage on the sedimentation and dissolved air flotation(SeDAF) process for enhanced phosphorus removal in sewage treatment facilities)

  • 장여주;정진홍;김원재
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.411-423
    • /
    • 2020
  • To remove phosphorus from the effluent of public wastewater treatment facilities, hundreds of enhanced phosphorus treatment processes have been introduced nationwide. However, these processes have a few problems including excessive maintenance cost and sludge production caused by inappropriate coagulant injection. Therefore, the optimal decision of coagulant dosage and automatic control of coagulant injection are essential. To overcome the drawbacks of conventional phosphorus removal processes, the integrated sedimentation and dissolved air flotation(SeDAF) process has been developed and a demonstration plant(capacity: 100 ㎥/d) has also been installed. In this study, various jar-tests(sedimentation and / or sedimentation·flotation) and multiple regression analyses have been performed. Particularly, we have highlighted the decision-making algorithms of optimal coagulant dosage to improve the applicability of the SeDAF process. As a result, the sedimentation jar-test could be a simple and reliable method for the decision of appropriate coagulant dosage in field condition of the SeDAF process. And, we have found that the SeDAF process can save 30 - 40% of coagulant dosage compared with conventional sedimentation processes to achieve total phosphorus (T-P) concentration below 0.2 mg/L of treated water, and it can also reduce same portion of sludge production.

역세척수 회수시스템이 포함된 배출수처리공정의 설계 (Design of Residual Treatment Process with Filter Backwash Recycle System)

  • 배병욱;최경환
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.109-114
    • /
    • 2012
  • In this study, both sedimentation and thickening experiments were conducted for residuals produced from an advanced water treatment plant for more accurate and practical design of residual treatment train. In order to design a backwashed residual sedimentation basin (SRSB) in the filter backwash water recycle system, two kinds of backwash waters, one from sand filter (SFBW) and the other from GAC adsorption bed (GACBW), were separately collected and their surface loading rate measured. In addition, in order to design a gravity thickener, batch thickening tests were conducted for concentrated residuals taken from sedimentation basin and their limiting solid flux ($SF_{L}$) measured. From the experimental results and consideration of the seasonal characteristics of the residual, surface loading rate of $70m^{3}/m^{2}{\cdot}d$ was proposed as a design parameter for SRSB and solid loading rate of 20 kg $TS/m^{2}{\cdot}d$ was proposed as a design parameter for gravity thickeners. Finally, the material mass-balance was made for the design of each unit process in the residual treatment train.

정수공정 개선을 위한 유기성 Polymer의 사용 (Utilization of Organic Polymers for Improvement of Drinking Water Treatment Process)

  • 이화자;김정숙;강임석
    • 한국환경과학회지
    • /
    • 제7권2호
    • /
    • pp.217-222
    • /
    • 1998
  • Organics matters including algae are the major contaminants of Nak-dong river and it's concentration Is more Increasing now. The use of coagulants has been Incresed for the effective treatment of drinking water, and aluminum coagulants have been the most widely used in raw water treatment. However, when inorganic metal coagulant is excessively used for long period, it would result in secondary problems, such as increasing sludge production, enhancing the cost of water treatment process, and increasing concentration of residual metal, especially aluminum. Therefore, recently. in order to reduce the use of metal coagulant and enhance the coagulation effectiveness, several alternative coagulants, such as polymeric Inorganic coagulants and organic polymers, have been used In water treatment plants. The objectives of thins research were (11 to determine optimum dosage concentration and compare the coajuiation efnciency at various pH ranees with alum alone, alum+cationic polymer, and alum+anlonlc polymer, (21 to evaluate the amount of alum reduced by using organic polymer, (31 to maximize removal officiency of organic matter and minimize the concentration of residual aluminum.

  • PDF

유입하수에 따른 BNR에서의 N과 P 제거율에 관한 연구 (Removal Ratio of Nitrogen & Phosphorus according to Sewage Inflow in the Biological Treatment(Biological Nutrient Removal)Process)

  • 이한섭;정광보;안성환;김경호;원성권
    • 한국응용과학기술학회지
    • /
    • 제31권4호
    • /
    • pp.669-678
    • /
    • 2014
  • The amount of waste water generated from the domestic sources is consistently increasing in proportion to economic growth, and the conventional activated sludge process is widely being used for general waste water treatment. But the ministry of environment becomes stringthent treatment standards of N and P (less than 20mg/L of N, 2mg/L of P) to prevent the eutrophication of lake water, and therefore highly advanced treatment technology is required not only in the existing treatment plants where the activated sludge process is being used, but also in newly constructed treatment plants for the treatment of N and P. This study is aimed at highly operating the engineering technology method was developed by domestic to eliminate N and P at the same time. Experiments were conducted in the treatment plant located in Yong In city. The bioreactor was started from the principal equipment for the elimination of N and P and the elimination of organic compounds. It consists of an internal recycle piping from the end of the aerobic tank to the anoxic tank and external recycle piping from the final settling basin to the denitrification tank. By experiment of 4 types separate inflow of waste water to the denitrification tank and the anaerobic tank, and changes in staying time at the anoxic tank and the aerobic tank, the elimination of organic compounds in each type and the relationship in the efficiency between the elimination of N and P were researched.

하수처리수 재이용을 위한 RO 공정의 타당성 및 막오염 평가 (Evaluation of RO Process Feasibility and Membrane Fouling for Wastewater Reuse)

  • 홍기웅;이상엽;김창우;부찬희;박명균;안호철;홍승관
    • 한국물환경학회지
    • /
    • 제26권2호
    • /
    • pp.289-296
    • /
    • 2010
  • The purpose of this study is to evaluate various pre-treatment methods and proprieties of water quality for wastewater reuse using reverse osmosis (RO) processes. Secondary effluents were sampled from wastewater treatment plants and lab scale pre-treatments and RO filtration test were conducted systematically. Specifically, different types of pre-treatments, such as coagulation, microfiltration and ultrafiltration, were employed to evaluate the removal efficiency of particle and organic matters which may affect the membrane fouling rate. RO process was later added to eliminate trace amounts of remaining organic matters and salt from the raw water for wastewater reclamation. The permeate through the RO process satisfied water quality regulations for industrial water uses. The experimental results showed that the initial fouling tendency differed not only by the feed water properties but also by the membrane characteristics. Membrane fouling was greater for the membranes with large surface roughness, regardless of the hydrophobicity and zeta potentials. Thus both careful consideration of pre-treatment options and proper selection of RO membrane are of paramount importance for an efficient operation of wastewater treatment.

미규제 수질인자를 이용한 정수공정의 효율성 평가 (Evaluation of Treatment Efficiency using non-Control Indicator in Drinking Water Treatment Process)

  • 이재영;강미아
    • 지질공학
    • /
    • 제16권2호
    • /
    • pp.153-159
    • /
    • 2006
  • 수질오염이 심각해지면서 수자원의 이용을 어렵게 하며 수자원의 관리를 위해 사용되는 시간적 기술적 경제적 부하도 증대시키고 있다. 그러므로 본 논문에서는 간단하고 신속하게 수질을 파악 할 수 있는 미규제 수질인자($E_{260}$과 입자수)를 도입하여 정수공정의 효율성을 평가하고자 하였다. 탁도저감을 목적으로 주입하는 알루미늄에 의해 용존성 알루미늄의 잔존량이 증가하는 경향이 있으므로 탁도 모니터링만으로는 안전한 수질을 기대하기가 어려움을 명확히 알 수 있었으며, 잔존알루미늄의 농도를 모니터링 하는 대신 간단 신속하게 분석할 수 있는 $E_{260}$인자를 이용할 수 있음을 밝혔다. 또한 탁도 뿐만 아니라 용존성 비소화합물의 모니터링에도 $E_{260}$은 효율적으로 사용되었다. 수처리공정의 효율을 개선하기 위해 수처리제의 교환을 고려할 때에도 탁도 자료만으로는 질적인 개선정도를 평가하기 어려웠으나, 수중의 입자를 계수함으로써 재선정도의 평가가 용이해져 적절한 수처리제의 선택을 가능하게 하므로 수질개선과 경제적 절약을 모두 달성하게 하였다. 따라서 효율적인 정수처리 뿐만 아니라 수자원의 관리 측면에서도 이들 인자는 매우 유용하게 사용될 수 있을 것으로 기대된다.

CFD를 이용한 농축조 슬러지의 유출흐름특성 해석 (Analysis of the sludge thickening characteristics in the thickener using CFD Model)

  • 박노석;문용택;김병군;김홍석
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.777-782
    • /
    • 2011
  • The residual treatment facilities in WTP(water treatment plant) play an important role in solid-liquid separation. At present, it is difficult to solve problems related with thickening and dewatering of WTP sludge, and discharging waste water to river. The quantity of residuals generated from water treatment plants depends upon the raw water quality, dosage of chemicals used, performance of the treatment process, method of sludge removal, efficiency of sedimentation, and backwashing frequency. Sludge production by the physical separation of SS(Suspended Solid) occurs under quiescent conditions in the primary clarifier, where SSs are allowed to settle and to consolidate on the clarifier bottom. Raw primary sludge results when the settled solids are hydraulically removed from the tank. In this study, Drawing characteristics of the sludge thickening in the thickener of Water Treatment Plants was simulated by Using CFD(Computational Fluid Dynamics.