• Title/Summary/Keyword: water temperature increase

Search Result 2,313, Processing Time 0.029 seconds

Effect of Air Temperature Changes on Water Temperature and Hysteresis Phenomenon in Lake Paldang (기온 변화에 따른 팔당호 수온 영향 및 이력현상)

  • Yu, Soonju;Im, Jongkwon;Lee, Bomi
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.5
    • /
    • pp.323-337
    • /
    • 2020
  • Long-term continuous data were used to investigate changes in air and water temperature and temperature hysteresis at Lake Paldang, the largest source of drinking water in South Korea. Based on the temperatures at Yangpyeong, near Lake Paldang, using a seasonal Mann-Kendall test, the rate of change of increase in temperature over the last 27 years (0.060℃/yr, 1993-2019) was higher than that of during 47 years (0.048℃/yr, 1973-2019). The air and water temperatures in Lake Paldang and its influent rivers had a high correlation (R > 0.9, p < 0.005); however, the water temperature increased at rate slower than the river water temperature, and the water temperature decreased slowly as the air temperature fell. The depth-averaged water temperature also changed more slowly than the surface water of the lake both when the air temperature was high and when it was low. This is likely because the lake has a larger area and a longer heat retention time than rivers, resulting in a greater hysteresis of water temperature at lake.

A Study on the Effects of Salinity and Washing in on Aerobic Composting of Food Wastes

  • Park, Seok-Hwan
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2004.06a
    • /
    • pp.207-209
    • /
    • 2004
  • This study was performed to estimate the effects of salinity and washing of food wastes on temperature, pH, and salinity in aerobic composting of food wastes. Weight ratios of food wastes to water in washing were 1:0(Control), 1:1(W-1), 1:2(W-2), 1:3(W-3) and 1:4(W-4), respectively. Ratios of food wastes to wood chips in reactor of Control, W-1, W-2, W-3 and W-4 were 5kg:5L, respectively. Reactors were operated for 24 days with 1 hour stirring by 1 rpm and 2 hours aeration per day. The increase in the ratio of food wastes to water used in washing resulted in the decrease of the highest reaction temperature and the elongation of the high temperature reaction period. The lowering of the ratio of food wastes to water used in washing resulted in faster pH increase The final salinities of Control, W-1, W-2, W-3 and W-4 were 0.95%, 0.73%, 0.65%, 0.57% and 0.41%, respectively.

  • PDF

Effects of Washing of Food Wastes on Aerobic Composting (음식물쓰레기의 세척이 호기성 퇴비화에 미치는 영향)

  • 박석환
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • This study was performed to estimate the effects of washing of food wastes on temperature, pH, weight and volume reduction and salinity in aerobic composting of food wastes. Weight ratios of food wastes to water in washing were 1:0(Control), 1:1 (W-1), 1:2(W-2), 1:3(W-3) and :4(W-4), respectively. Ratios of food wastes to wood chips in reactor of Control, W-1, W-2, W-3 and W-4 were 5 kg:5 1, respectively. Reactors were operated for 24 days with 1 hour stirring by 1 rpm and 2 hours aeration per day. The increase in the ratio of food wastes to water used in washing resulted in the decrease of the highest reaction temperature and the elongation of the high temperature reaction period. The lowering of the ratio of food wastes to water used in washing resulted in faster pH increase and the steady state in the weight reduction rate and the volume reduction rate of composts. The final salinities of Control, W-1, W-2, W-3 and W-4 were 0.95%, 0.73%, 0.65%, 0.57% and 0.41%, respectively.

Characterization of membrane fouling and CEB (Chemical enhanced backwashing) efficiency with temperature in SMBR Process (MBR 공정에서 수온에 따른 막오염 및 CEB 세정효율 특성)

  • Park, Kitae;Park, Jeonghoon;Choi, Eunhye;Kim, Hyungsoo;Kim, Jihoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.389-395
    • /
    • 2017
  • In this paper, we investigate the characteristics of membrane fouling caused by water temperature in the Membrane bioreactor(MBR) process and try to derive the membrane fouling control by chemical enhanced backwashing(CEB). The extracellular polymeric substances(EPS) concentration was analyzed according to the water temperature in the MBR, and the membrane fouling characteristics were investigated according to the conditions, with sludge & without sludge, through a lab-scale reactor. As shown in the existing literature the fouling resistance rate was increased within sludge with the water temperature was lowered. However, in the lab-scale test using the synthetic wastewater, the fouling resistance increased with the water temperature. This is because that the protein of the EPS was more easily adsorbed on the membrane surface due to the increase of entropy due to the structural rearrangement of the protein inside the protein as the water temperature increases. In order to control membrane fouling, we tried to derive the cleaning characteristics of CEB by using sodium hypochlorite(NaOCl). We selected the condition with the chemicals and the retention time, and the higher the water temperature and the chemical concentration are the higher the efficiencies. It is considered that the increasing temperature accelerated the chemical reaction such as protein peptide binding and hydrolysis, so that the attached proteinaceous structure was dissolved and the frequency of the reaction collision with the protein with the chemical agent becomes higher. These results suggest that the MBRs operation focus on the fouling control of cake layer on membrane surface in low temperatures. On the other hand, the higher the water temperature is the more the operation strategies of fouling control by soluble EPS adsorption are needed.

The Influence of Temperature on the Surface Electrokinetic Features of Particulate Matters in Aqueous Environment (수중입자의 표면 전기적 특성에 미치는 온도의 영향)

  • O, Sejin;Kim, Dong-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.525-531
    • /
    • 2010
  • To figure out the importance of temperature on electrochemical properties in water environment, calcium carbonate, one of important substances in water chemistry, was chosen to make suspensions. The result of electrokinetic potential of calcium carbonate suspensions revealed that it tended to increase as temperature increased. In addition, electrokinetic potential was negatively increased as suspensions became more basic. Its isoelectric point was ca. 7 regardless of temperature. The adsorption of hydrogen ions on calcium carbonate particles followed endothermic reaction. This result was verified by continuously measuring pH as adding HCl solution in calcium carbonate suspension. It explained that suspensions' potential was determined by DLVO theory which calculated total interaction energy between particles. Suspensions' total interaction energy was proportional to the value of electrokinetic potential. Furthermore, total interaction energy between particles increased as suspensions' temperature was increased.

Effect of Distilled Water Supply Method on Performance of PEMWE Typed Hydrogen Generators for Inhalation (흡입용 PEMWE형 수소 발생기에서 증류수 공급 방법이 성능에 미치는 영향)

  • In-Soo, You;Hyunwoo, Bae;Joon Hyun, Kim;Jaeyong, Sung
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.117-127
    • /
    • 2022
  • The present study has investigated the performance of hydrogen gas generators for inhalation purposes based on polyelectrolyte membrane water electrolysis (PEMWE). The system applied two watering methods. One is pumped water (pumping system) and the other is gravity-fed water without a pump (non-pumping system). The cell efficiencies were compared by measuring the cell voltage and temperature in the hydrogen gas generator, respectively. The results show that the cell voltage and temperature increase with the cell current. The cell temperature is lower in the pumping system than that in the non-pumping system at a given cell current. Even though the amount of hydrogen production is the same regardless of the pumping system, the cell efficiency of the hydrogen gas generator in the non-pumping system is better than that in the pumping system.

Effect of firing temperatures on alkali activated Geopolymer mortar doped with MWCNT

  • Khater, H.M.;Gawwad, H.A. Abd El
    • Advances in nano research
    • /
    • v.3 no.4
    • /
    • pp.225-242
    • /
    • 2015
  • The current investigation aims to study performance of geopolymer mortar reinforced with Multiwalled carbon nanotubes upon exposure to $200^{\circ}C$ to $1000^{\circ}C$ for 2 hrs. MWCNTs are doped into slag Geopolymer mortar matrices in the ratio of 0.0 to 0.4, % by weight of binder. Mortar composed of calcium aluminosilicate to sand (1:2), however, binder composed of 50% air cooled slag and 50% water cooled slag. Various water / binder ratios in the range of 0.114-0.129 used depending on the added MWCNT, while 6 wt., % sodium hydroxide used as an alkali activator. Results illustrate reduction in mechanical strength with temperature except specimens containing 0.1 and 0.2% MWCNT at $200^{\circ}C$, while further increase in temperature leads to decrease in strength values of the resulting geopolymer mortar. Also, decrease in firing shrinkage with MWCNT up to 0.1% at all firing temperatures up to $500^{\circ}C$ is observed, however the shrinkage values increase with temperature up to $500^{\circ}C$. Further increase on the firing temperature up to $1000^{\circ}C$ results in an increase in the volume due to expansion.

Optimum Design of Middle-Sized CO2 Water Heater (중형 이산화탄소 급탕기의 최적 설계)

  • Park, Hanvit;Yun, Rin;Kim, Young Deug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.4
    • /
    • pp.173-179
    • /
    • 2013
  • Middle-sized $CO_2$ water heater having compressor power of 7.45 kW was designed, and its performances were experimentally tested. Besides, optimum design of the $CO_2$ water heater was conducted by cycle simulation. When ambient temperature of $7^{\circ}C$ and hot water outlet temperature of $80^{\circ}C$ the $CO_2$ water heater showed the COP of 3.2. As hot water temperature increased the COP is getting decreased due to significant increase of compressor power consumption compared to increasing rate of heating capacity. When ambient temperature increased from $-3^{\circ}C$ to $12^{\circ}C$ the COP increased by 30%. The optimum components design of a gas cooler, an internal heat exchanger, and an evaporator were conducted, and the experimental correlation between amount of EEV opening and ambient temperature, and hot water temperature was suggested.

Influences of Construction Conditions on the Properties of Cement Mortars in Floors Using Expansion Agent (팽창재를 사용하는 바닥 모르타르의 특성에 미치는 시공요인의 영향)

  • 표대수;정성철;송명신;홍상희;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.925-928
    • /
    • 2000
  • In this paper, physical properties of cement mortar for floor using expansion agent are discussed varied with mixing time and curing temperature, delivery time and content of added water for preventing fluidity loss. According to experimental results, slump loss shows high with elapse of time And as curing temperature goes up, it also show high when curing temperature goes up and time lag between mixing and casting increases. As curing temperature goes down, drying shrinkage shows to be decreased. But it shows decline tendency with increase of added water content.

An Experimental Study on the Performance of a Liquid-Vapor Ejector with Water (액체-증기 이젝터의 성능에 관한 실험적 연구)

  • 박대웅;정시영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.345-353
    • /
    • 2000
  • In this study, the performance of five ejectors has been investigated with working fluids of water and water vapor. The diameters of nozzle and mixing tube of five ejectors were 1 and 1.5(ejector A), 1 and 2(ejector B), 1 and 2.5(ejector C), 1 and 3(ejector D), 2 and 4(ejector E) in millimeters. The length of the mixing tube was 8-10 times of its diameter. For each ejector, the ratio of mass flow rate of ejected water to that of entrained water vapor, $\mu$, was evaluated in terms of evaporator pressure, mass flow rate of ejected water, and water temperature. It was found that the performance of an ejector was not stable when the ratio of diameters was too small or too large(ejector A and D) and $\mu$ was almost the same for two ejectors with the same diameter ratio(ejector B and E). It was also found that $\mu$ increased almost linearly with an increase of evaporator pressure and the ratio $\mu$ increased as water temperature decreased. As expected, $\mu$ converged to zero as the water temperature approached the evaporator temperature. Finally, a non-dimensional correlation has been developed to predict$\mu$ terms of evaporator pressure and saturation pressure of ejected water.

  • PDF