• 제목/요약/키워드: water temperature increase

검색결과 2,313건 처리시간 0.029초

산철쭉과 영산홍의 과냉각 능력과 수분함량에 관한 온도 영향 및 해부학적 특성 (Temperature Effects and Anatomical Characteristics on Supercooling Ability and Water Content of Rhododendron yedoense Maxim. var. poukhanense Nakai and R. simsii Planch.)

  • 신관배
    • Journal of Plant Biology
    • /
    • 제26권1호
    • /
    • pp.33-39
    • /
    • 1983
  • Twigs bearing floral buds of Rhododendron yedoense var. poukhanense(Ryp) and R. sinmsii(Rs), hardy species in Korea, were used to investigate the cold hardiness in relation to the developmental and anatomical characteristics, and the changes of water content. In floral buds of both species, the reproductive organs, pistils and stamens, matured within the bud scales in early ctober to prepare for a cold acclimation. The ray parenchymatous areas occupied in xylem were 41% in Ryp and 38% Rs. As the storage temperature is raised from 2 to 17$^{\circ}C$, water content increased more highly in Rs than in Ryp. Exotherm temperature of floral bud in Ryp was generally lower than that in Rs. The result supports that the higher cold-hardiness is achieved owing to the earlier maturation of floral buds, to the larger area of ray parenchyma in xylem, and to the lesser increase of water content as the storage temperature is raised.

  • PDF

Effects of Turbine Inlet Temperature on Performance of Regenerative Gas Turbine System with Afterfogging

  • Kim, Kyoung-Hoon;Kim, Se-Woong;Ko, Hyung-Jong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권4호
    • /
    • pp.141-148
    • /
    • 2009
  • Afterfogging of the regenerative gas turbine system has an advantage over inlet fogging in that the high outlet temperature of air compressor makes the injection of more water and the recuperation of more exhaust heat possible. This study investigates the effects of turbine inlet temperature (TIT) on the performance of regenerative gas turbine system with afterfogging through a thermodynamic analysis model. For the standard ambient conditions and the water injection ratios up to 5%, the variation of system performance including the thermal efficiency is numerically analyzed with respect to the variations of TIT and pressure ratio. It is also analyzed how the maximum thermal efficiency, net specific work, and pressure ratio itself change with TIT at the peak points of thermal efficiency curve. All of these are found to increase almost linearly with the increases of both TIT and water injection ratio.

폐온수 이용 제 2 종 흡수식 열펌프의 열역학적 설계해석 (Thermal Design Analysis of an Absorption Heat Transformer for using Waste Hot Water)

  • 강병하;김영인;이춘식
    • 대한설비공학회지:설비저널
    • /
    • 제14권4호
    • /
    • pp.285-292
    • /
    • 1985
  • A computer program for thermal design analysis has been developed to predict the performance of an absorption heat transformer. The effects of temperature boost, cooling water temperature and effectiveness of components on the performance were investigated. Not only the detailed thermodynamic states such as temperatures, concentration of the solution, and mass flow rate at each point of the process but also the heat transfer rate in each component could be easily determined with given input parameters. The system's coefficient of performance (COP) was seen to increase with increased effectiveness of components, decreased temperature boost of hot water, and decreased cooling water temperature. Even though the COP increases with increased effectiveness of the components, the variation in the COP is not substantial above certain values of the effectiveness. A reference design point can be selected on this basis.

  • PDF

오스테나이타이징 온도와 냉각 속도가 SCM415 저탄소강의 미세조직과 경도에 미치는 영향 (Effect of Austenitizing Temperature and Cooling Rate on Microstructure and Hardness of Low-carbon SCM415 Steel)

  • 이종언;이교명;차재원;박성혁
    • 소성∙가공
    • /
    • 제31권4호
    • /
    • pp.207-213
    • /
    • 2022
  • In this study, variations in the microstructure and hardness of a low-carbon SCM415 steel with austenitizing temperature and cooling rate are investigated. When the austenitizing temperature is lower than the A1 temperature (738.8 ℃) of the SCM415 steel, the microstructures of both the air-cooled and water-cooled specimens consist of ferrite and pearlite, which are similar to the microstructure of the initial specimen. When heat treatment is conducted at temperatures ranging from the A1 temperature to the A3 temperature (822.4 ℃), the microstructure of the specimen changes depending on the temperature and cooling rate. The specimens air- and water-cooled from 750 ℃ consist of ferrite and pearlite, whereas the specimen water-cooled from 800 ℃ consists of ferrite and martensite. At a temperature higher than the A3 temperature, the air-cooled specimens consist of ferrite and pearlite, whereas the water-cooled specimens consist of martensite. At 650 ℃ and 700 ℃, which are lower than the A1 temperature, the hardness decreases irrespective of the cooling rate due to the ferrite coarsening and pearlite spheroidization. At 750 ℃ or higher, the air-cooled specimens have smaller grain sizes than the initial specimen, but they have lower hardness than the initial specimen owing to the increased interlamellar spacing of pearlite. At 800 ℃ or higher, martensitic transformation occurs during water cooling, which results in a significant increase in hardness. The specimens water-cooled from 850 ℃ and 950 ℃ have a complete martensite structure, and the specimen water-cooled from 850 ℃ has a higher hardness than that water-cooled from 950 ℃ because of the smaller size of prior austenite grains.

Tobermolite를 이용한 폐수내 인산염제거 (Phosphate Removal in Wastewater by Tobermolite)

  • 임봉수;김대현;이태우
    • 상하수도학회지
    • /
    • 제27권6호
    • /
    • pp.751-759
    • /
    • 2013
  • This study is carried out to get the basic design parameters for phospate removal facilites from wastewater by Tobermolite. The phosphate removal by the apatite formation on the surface was affected by several important factors, temperature, ions present in wastewater stream, contact time, recirculation rate, and etc. In case of the temperature, with the increase of temperature, the apatite formation was accelerated. When temperature increased from $15^{\circ}C$ to $35^{\circ}C$, removal efficiency of phosphate increased from 83 % to 93 %. An increase of calcium and fluoride ion content increase the apatite formation, however, bicarbonate and magnesium ion inhibited the crystallization of apatite. As expected, when the recirculation rate was increased from 1 Q to 3 Q, at EBCT (Empty Bed Contact Time) 60min enhanced removal efficiency was observed. The more the recirculation rate increased, the more the removal efficiency increased. According to the results of column experiment using an actual wastewater with low and high phosphate concentration (5 mg/L and 50 mg/L-P), the removal efficiency was 77 % at EBCT of 45 min, and 80 % at 60 min. It was suggested that optimum EBCT was 45 min.

점용접 아연도금판의 강도특성에 대한 온도 및 침수의 영향 (Effect of Temperature and Water Assumtion on Strength of Spot Welded Zine Steel Plates)

  • 서도원;윤호철;최준용;임재규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.358-363
    • /
    • 2003
  • Spot welded structure is operated in diverse situation because of temperature, humidity and precipitation. In addition factors of environmental pollution such as acid rain, that courses corrosion, have the tendency to increase, But spot welded structure strength is affected by dampness and environment temperatures. Therefore, it is important to evaluate effect of temperature of spot welded part, In this study, the strength distribution of spot welded plates is evaluated about the environmental temperature of zine coated steel plates and test is conducted with welded part immersed in distilled and synthetic sea water. Specimens are immersed into water for 10, 100, 500 and 1000hours to evaluate the effects of water immersion time on tensile-shear strength under the conditions of -40, 0, 20 and $50^{\circ}C$. Strength is evaluated by tensile-shear test. The conditions of spot welding are 240kgf electrode force, 10KA welding current with 0 and 5mm clearance. From this study, spot welded specimens with clearance have lower tensile-shear strength in the distilled water or synthetic sea water comparing with spot welded specimens without clearance. And they have lower tensile-shear strength under $-40^{\circ}C$ and over $50^{\circ}C$.

  • PDF

Variation Pattern of ${\delta}^{13}C_{DIC}$ of the Odaecheon Stream Water

  • Shin, Woo-Jin;Chung, Gong-Soo
    • 한국지구과학회:학술대회논문집
    • /
    • 한국지구과학회 2005년도 춘계학술발표회 논문집
    • /
    • pp.115-125
    • /
    • 2005
  • Carbon isotopic composition of a stream (Odaecheon Stream) monitored over 7 months from July 2004 to January 2005 in Gangweon Province ranges from -9.24 to -4.69‰. Strong negative correlation between ${\delta}^{13}C_{DIC}$ and water temperature suggests that temperature is a dominant factor controlling ${\delta}^{13}C_{DIC}$ in the Odaecheon Stream. The variation pattern of ${\delta}^{13}C_{DIC}$ was thought to be caused by fractionation of C isotope between stream water and atmosphere and more fractionation at reduced temperature. More fractionation of C isotope between stream water and atmosphere at reduced temperature resulted in increase of ${\delta}^{13}C_{DIC}$ of stream water in winter compared to summer. Photosynthesis and respiration of aqueous biota seem to affect little in ${\delta}^{13}C_{DIC}$ as indicated by little variation of dissolved oxygen and reverse variation pattern of Eh in the stream and scarce aqueous biota in stream water. pH seems to be controlled by $CO_2{2}$ exchange between stream water and atmosphere. During summer more $CO_2{2}$ exchange between stream water and atmosphere resulted in decrease in pH value.

  • PDF

암석의 온도의존성을 고려한 열-수리-역학적 상호작용의 수치해석적 연구 (Numerical Study on Thermo-Hydro-Mechanical Coupling in Rock with Variable Properties by Temperature)

  • 안형준;이희근
    • 터널과지하공간
    • /
    • 제7권1호
    • /
    • pp.13-19
    • /
    • 1997
  • It is necessary to study on thermo-hydro-mechanical effect at rock mass performing project such as radiowaste disposal in deep rock mass. In this study, thermo-hydro-mechanical coupling analysis which is considered interaction and the variation of rock properties induced by temperature increase was performed for the circular shaft when appling temperature of 20$0^{\circ}C$ at the shaft wall. The shaft is diameter of 2 m and under hydrostatic stress of 5 MPa. In the cases, thermal expansion by temperature increase progress from the wall to outward and thermal expansion could induce tensile stress over the tensile strength of rock mass at the wall. When rock properties were given as a function of temperature, thermal expansion increased, tensile stress zone expanded. Lately, water flow is activated by increase of permeability and decrease of viscosity.

  • PDF

임플란트 지대주 삭제시의 발생열에 관한 연구 (A Study on the heat generation during implant abutment preparation)

  • 이호진;송광엽;장태엽
    • 구강회복응용과학지
    • /
    • 제19권1호
    • /
    • pp.27-33
    • /
    • 2003
  • Excessive heat generation at the implant-bone interface may cause irreversible bone damage and loss of osseointegration. The effect of heat generation in vitro at the implant surface caused by abutment reduction with high-speed dental turbine was examined. Titanium-alloy abutments connected to a titanium alloy screw-implant embedded in an acrylic-resin block in a $37^{\circ}C$ water bath were prepared. Temperature changes were recorded via embedded thermocouples at the cervix and apex of the implant surface. Analysis of variance for repeated measures was used to compare seven treatment groups. Fifty seconds of continuous cutting with air and water coolant caused a mean temperature increase of $1.24^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $2.50^{\circ}C$ at apex and $1.64^{\circ}C$ at cervix. But, continuous cutting with air coolant caused a mean temperature increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Preparation of implant abutment does not lead to detrimental effect on peri-implant tissues provided that adequate cooling. However, without water cooling, extreme overheating could be provoked, reaching the critical temperature that would lead to irreversible bone damage within only a few seconds.

Pervaporation Separation of Water from Aqueous TFEA Solution by NaY Zeolite Membrane

  • Jeon, Hyun-Soo;Ahn, Hyo-Seong;Lee, Young-Jin;Song, In-Ho;Lee, Hyer-Yeon;Lee, Yong-Taek;Park, In-Jun;Lee, Soo-Bok
    • Korean Membrane Journal
    • /
    • 제8권1호
    • /
    • pp.31-35
    • /
    • 2006
  • Pervaporation of water/2,2,2-trifluoroethanol (TFEA) mixtures was performed using a NaY zeolite membrane which was prepared by a hydrothermal synthesis. Pervaporation with a zeolite membrane is one of the economic separation technologies for liquid mixtures including organic/water solutions. The effects of a TFEA feed concentration and a temperature were studied on the permeation flux and the separation factor. Not only the water flux increased significantly with the increase of the operating temperature, but also the TFEA flux through the NaY zeolite membrane rapidly increased with the increase of the temperature at the feed concentration below 0.8 mole fraction of TFEA.