• Title/Summary/Keyword: water surface velocity meter

Search Result 31, Processing Time 0.03 seconds

Analysis on Correlation Coefficient of Surface Image Velocimeter (SIV) Using On-site Runoff Image (현장유출영상을 활용한 표면영상유속계(SIV)의 상관계수 분석)

  • Kim, Yong-Seok;Yang, Sung-Kee;Kim, Dong-Su;Kim, Seojun
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.403-414
    • /
    • 2015
  • This study is daytime and nighttime runoff image data caused by heavy rain on May 27, 2013 at Oedo Water Treatment Plant of Oedo-Stream, Jeju to compute runoff by applying Surface image velocimeter (SIV) and analyzing correlation according to current. At the same time, current was comparatively analyzed using ADCP observation data and fixed electromagnetic surface current meter (Kalesto) observed at the runoff site. As a result of comparison on resolutions of daytime and nighttime runoff images collected, correlation coefficient corresponding to the range of 0.6~0.7 was 6.8% higher for nighttime runoff image compared to daytime runoff image. On the contrary, correlation coefficient corresponding to the range of 0.9~1.0 was 17% lower. This result implies that nighttime runoff image has lower image quality than daytime runoff image. In the process of computing current using SIV, a rational filtering process for correlation coefficient is needed according to images obtained.

Measurement of Discharge Using the Entropy Concept (엔트로피 개념에 의한 유량측정 기법)

  • Choo, Tai-Ho;Lee, Seung-Kwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.05a
    • /
    • pp.342-346
    • /
    • 2006
  • The method presented is also efficient and applicable in estimating the discharge in high flows that are very difficult or impossible to measure before, due to technical or theoretical reasons. The method can drastically reduce the time and cost of measurement, regardless of the irregularity in the geometrical shape. With Microwave Water Surface Velocity Meter, An entropy based method for determining the discharge in the rivers can be used to develop real-time discharge measurement system (RDMS) which can carry out the real-time inflow hydrograph.

  • PDF

Velocity and temperature profiles of Al/water micro fluid in a circular tube with swirl

  • Chang, Tae-Hyun;Lee, Kwon Soo;Lee, Chang-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.7
    • /
    • pp.677-684
    • /
    • 2013
  • A lot study of convection heat transfer on internal flow has been extensively conducted in the past decades using of high specific surface area, increasing heat transfer coefficient, swirling flow and improving the transport properties. This study concerned with the application of a tangential slot swirl generator for improving heat transfer in a horizontal circular copper tube. The Al particles(about $100{\sim}130{\mu}m$) was employed for this experimental work. 3D PIV(particle image velocimetry) technique has employed to measure velocity profiles of Al particles with and without swirl flow. The copper tube is heated uniformly by winding of a heating coil for heat transfer work, having a resistance of 9 ohm per meter. Experiments are performed in the Reynolds number range of 6,800~12,100 with swirl and without swirl using Al particles. Experimental data for comparison of Nusselt number is presented that of with swirl and without swirl along the test tube for the Reynolds numbers. The Nusselt number is improved with increasing of Reynolds numbers or swirl intensities along the test tube. The Nusselt number with swirl flow is about 60.0% to 119.0% higher than that obtained by the Dittus-Boelter equation.

Research on Real-time Flow Rate Measurement and Flood Forecast System Based on Radar Sensors (레이다 센서 기반 실시간 유량 측정 및 홍수 예측 시스템 연구)

  • Lee, Young-Woo;Seok, Hyuk-Jun;Jung, Kee-Heon;Na, Kuk-Jin;Lee, Seung-Kyu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.288-290
    • /
    • 2022
  • As part of the SOC digitization for smart water management and flood prevention, the government reported that automatic and remote control system for drainage facilities (180 billion won) to 57% of national rivers and established a real-time monitoring system (30 billion won). In addition, they were also planning to establish a smart dam safety management system (15 billion won) based on big data at 11 regions. Therefore, research is needed for smart water management and flood prevention system that can accurately calculate the flow rate through real-time flow rate measurement of rivers. In particular, the most important thing to improve the system implementation and accuracy is to ensure the accuracy of real-time flow rate measurements. To this end, radar sensors for measuring the flow rate of electromagnetic waves in the United States and Europe have been introduced and applied to the system in Korea, but demand for improvement of the system continues due to high price range and performance. Consequently, we would like to propose an improved flow rate measurement and flood forecast system by developing a radar sensor for measuring the electromagnetic surface current meter for real-time flow rate measurement.

  • PDF

A Time Variable Modeling Study of Vertical Temperature Profiles in the Okjung Lake (옥정호의 연직 수온분포에 관한 시변화 모델 연구)

  • Park, Ok-Ran;Park, Seok-Soon
    • Korean Journal of Ecology and Environment
    • /
    • v.35 no.2 s.98
    • /
    • pp.79-91
    • /
    • 2002
  • A time variable modeling study was performed for seasonal variations of vertical temperature profiles in the Okjung Lake located in upstream of the Sumjin River. Based on the model structure of the US Army Corps of Engineer's CE-QUAL-W2, the lake was divided into 3 branches, 50 longitudinal segments and 49 vertical layers and vertical profiles of water temperature and current velocity were simulated over one year. The model results were calibrated and verified against vertical profiles of water temperature measured every month from March 1998 to February 1999 at 5 different locations. The model results showed a good agreement with the field measurements. The hydrologic balance during this period was validated by comparing the simulated values of surface elevation level with the measured data. There was some discrepancy in July data between the model results and the fleld measurements. This could be attributed partially to the inadequacy of the model to the highly hydrodynamic nature of water body and partially to the lack of accuracy in local atmospheric temperature data during summer monsoon period. The model results have shown that there was no seasonal over-turn in most part of the Okjung Lake, where water temperature maintained above $4^{\circ}C$ over one year. In the upstream shal-low area (depth<20 meter), however, temperature at surface layer fell below $4^{\circ}C$ and water was frozen such that slight over-turn would occur during winter period. From this study, we concluded that the Okjung Lake is oligomictic. This conclusionis significantly different from the general pattern that the lakes located from $20^{\circ}C$ to $40^{\circ}C$ latitude would be warm monomictic. From the examination of simulated current velocity distribution, it was found that the upstream inflows would infiltrate into mesolimnion of the lake during hydrodynamic summer monsoon periods due to the thermal density of water.

Measurements of Vertical Profiles in Suspended-Load Concentration Using the ASM-IV (ASM-IV를 이용한 부유사농도 연직분포의 측정)

  • Lee, Jong-Seok;Myeng, Bong-Jae;Cha, Young-Kee
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.1 s.20
    • /
    • pp.83-95
    • /
    • 2006
  • This study aims to analysis of suspended-load concentration in related to those data by measuring vertical sediments distribution with rainfall using the ASM (Argus Surface Meter)- IV at the channel reach of a upstream and a downstream in small river. The watershed, small river basin where had taken for experimental study was selected, which is a drainage area lied at Walha in Yunkee-Gun, Chungnam Province. Measured data of suspended-load concentration consists of two groups with 2,145 data during 1hr 11min 30sec and 1,216 data during 40min 32sec for measuring time of 2 second in the study reaches at river, respectively. In order to analyze of the vertical concentration distribution, using the data sets are selected the measuring time 16 sets one of these data by random in the study reaches. As a results, the Rouse number of a measured and a calculated value show that a rang of $0.00129{\sim}0.02394$, averaged value of 0.01129 md, a rang of $0.00118{\sim}0.00822$, averaged value of 0.00436 in upstream reaches, and also a rang of $0.065115{\sim}0.065295$, averaged value of 0.06521, and a rang of $0.057315{\sim}0.059109$, averaged value of 0.05795 in downstream reaches, respectively. These difference show that measured Rouse number compared with downstream reach errors of less than in upstream reach, but between measured and calculated of the Rouse number compared with downstream reach errors of more than in upstream reach, respectively. It seems to will be included one of the occurrence errors of variable estimations when Rouse number of calculated value to be made computed by the fall velocity with a high temperature of water using equation of empirical kinematic viscosity was derived in this study.

Development of Autonomous navigation of Drones and Automatic measurement system for Surface velocity doppler radar (드론의 자율운항 및 전자파표면유속계 자동 측정 시스템 개발)

  • Lee, Tae Hee;Kang, Jong Wan;Jeong, Seung Gyo;Kim, Geon Woo;Lee, Ki Sung;Lee, Sin Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.90-90
    • /
    • 2022
  • 전자파표면유속계를 이용한 유량측정은 전자파를 발사한 후 수표면에 반사되는 전자파의 도플러효과를 이용하여 표면유속을 측정하는 방법이다. 국제적으로 1980년대부터 홍수유량측정의 어려움을 극복하고자 전자파표면유속계를 개발하여 하천 유량측정 업무에 활용하였다. 미국의 경우U.S. Geological Survey (USGS)에서 교량, 케이블웨이, 제방, 헬리콥터, 비행기 등 전자파표면유속계의 측정 위치에 따라 주파수 범위를 달리하며 유속을 측정하는 연구가 진행되었다. 국내의 경우 Lee et al.(2021)은 드론을 이용한 전자파표면유속계 측정을 위해 드론으로부터 전자파표면유속계로 전달되는 진동을 제거하고 전자파표면유속계의 흔들림 방지를 위한 댐퍼플레이트를 개발하여 드론과 전자파표면유속계를 결합한 DSVM(Dron and Surface Veloctity Meter using doppler radar) 측정방법에 대한 실용성을 확인하였다. 기존 연구에서 DSVM 방법은 드론의 각 측선 이동을 위한 조종 및 전자파표면유속계 측정의제어를 측정자가 수행하였는데 본 연구에서는 자동 측정 시스템 개발을 통해 측정자의 조종 의존도를 줄임과 동시에 안전하고 정확한 유량측정을 위해 노력하였다. 측정지점의 위치정보를 DB화하여 각 측선별 이동하는 자율운항 기능과 전자파표면유속계를 자동으로 제어하여 측정을 실시하는 기능을 개발하였다. 또한 전자파표면유속계 컨트롤 시스템과 GCS(Ground Control System)를 통합하여 한 시스템에서 측정의 모든 상황을 컨트롤 할 수 있게 하였다. 현재까지는 DSVM 방법의 자율운항 기능과 자동 측정 시스템의 테스트를 완료하였고 2022년 홍수기 유량측정에 도입하여 홍수기 유량측정의 실용성을 판단할 계획이다.

  • PDF

An Study on flow Discharge Calculation using Surface Velocity (비접촉식 유속계의 표면유속을 이용한 유량산정방법에 관한 연구)

  • Roh, Youngsin;Lee, Sin Jae;Kim, Dae Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.230-230
    • /
    • 2020
  • 하천 유량측정을 위한 표면유속계는 비접촉식 방식이기 때문에 현장에서의 측정이 간편하고, 비교적 안전하기 때문에 홍수시 유량측정에 널리 이용되고 있다. 비접촉식 유속계가 가지고 있는 이러한 장점으로 전자파표면유속계의 활용이 점차 증가하고 있으며, 영상유속계와 같은 비접촉 측정방식의 활용방안 마련에 대한 연구개발 등이 꾸준히 진행되어 왔다. 최근에는 고정식으로 상시 운영이 가능한 표면유속계 등이 출시되어 소규모 하천이나 수로에서의 상시 유량측정에 활용되고 있다. 다만, 이러한 비접촉식 유속계는 표면의 유속을 측정하기 때문에 유량산정을 위해서는 평균유속으로의 환산이 필요하지만, 현재까지는 평균유속 환산계수를 사용하여 표면유속을 평균유속으로 환산하는 방법이 유일하게 활용되고 있다. 하지만, 실제 하천에서는 단면 및 하도형태, 하상조건, 수리특성 및 유속분포 등의 다양한 조건에 따라 환산계수가 결정되기 때문에 이를 단순히 일률적으로 적용하는 것은 곤란하며, 이로 인해 과거 오랫동안 표면유속을 평균유속으로 환산하기 위한 다양한 연구가 진행되었지만, 실제 다양한 조건의 하천에 적용할 수 있는 표준화된 방법은 아직까지 제시되지 못하고 있다. 현재까지, 고정식으로 설치된 유속계로부터 측정된 유속을 평균유속으로 환산하는 방법으로는 국내외적으로 지표유속법(Index Velocity Method)과 유속분포법(Velocity Profile Method)이 대표적이며, H-ADCP (Horizontal-Acoustic Doppler Velocity Profiler) 또는 UVM(Ultrasonic Velocity Meter) 등과 같은 초음파유속계를 활용한 자동유량측정시설의 유량산정방법으로 활용되고 있다. 이러한 방법들은 고정된 유속계의 측정유속을 지표유속(Vi)으로 하여 다양한 범위의 실측된 평균유속과의 관계를 개발하여 활용하거나, 지표유속을 매개로 개수로 단면의 이론적인 유속분포를 추정하여 평균유속을 산정한다. 이러한 지표유속을 활용하는 방법들에서 공통적으로 중요한 것은 하천단면의 최대유속(Vmax)이 가장 좋은 지표유속이라는 것이다. 따라서 국제기준에서는 지표유속을 측정하는 유속계의 가장 바람직한 위치로 유심부(core flow)를 권장하고 있다. 하지만, 접촉식 유속계의 경우 유심부 설치가 매우 어렵고 많은 비용이 들기 때문에, 비접촉식 유속계를 활용하여 하천단면의 최대유속을 측정할 수 있다면, 가장 효율적인 고정식 측정방법이 될 수 있을 것이다. 따라서, 본 연구에서는 비접촉식 표면유속계의 고정식 유량측정 활용성 및 적용성을 검토할 목적으로 표면유속에 대한 유량산정방법을 검토하였다. 이를 위해 24GHz의 주파수를 갖는 레이다표면유속계인 Sensoflow를 낙동강 수계 길안천에 위치한 안동시(대사3교)에 고정설치하여 표면유속을 지표유속으로 수집하였다. 다양한 유량규모에서 측정한 실측 표면유속과 수집된 표면유속을 지표유속으로 활용하여 지표유속관계를 개발하였으며, 산정된 유량을 기존 수위-유량관계곡선식의 환산유량과 비교하여 표면유속의 지표유속 활용성을 검토하였다.

  • PDF

Discharge Measurement Using Non-Contact Radar Surface Velocity Meter (비접촉식 레이더 표면 유속계를 이용한 유량 측정)

  • Kwon, Sung-Il;Kim, Yong-Jeon;Lee, Chan-Joo;Kim, Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1841-1844
    • /
    • 2009
  • 일반 하천에서의 유량측정 방법은 하천 조건에 따라 다르다. 전통적인 방법으로는 구조물에 의한 방법, 유속계 측정에 의한 유속-면적법, 부자에 의한 방법, 그리고 희석법 등이 있다. 그러나 이러한 방법들은 측정 위험성을 가지고 있다. 홍수시 발생되는 고유속과 심한 난류, 거대한 부유물질들은 하천 접근에 어려움을 가져오고, 측정 기기의 파손 위험성뿐만 아니라 인명피해까지 발생시킬 가능성이 있다. 최근 기존 방법들의 문제점을 해결하기 위하여 음파, 초음파, 레이더 등을 이용한 유량 측정 방법과 장비들이 개발되었다. 본 연구에서 사용한 레이더 유속계는 하천의 표면유속을 측정하는 비접촉식 센서로 홍수기 전 미리 유속 측정 단면 측량을 실시한다면 홍수시에도 비교적 신속하고 안전하게 유속을 측정할 수 있다. 따라서 본 연구에서는 레이더 유속계를 충청북도 괴산군 달천에 위치한 수전교에 설치하여 괴산댐 방류량 및 동시유량 측정 성과와 비교하였다. 2007년 7월부터 2008년 8월까지 $36m^3/s\;\sim\;821m^3/s$의 사상에서 총 10회 측정한 결과, 레이더 유속계를 사용하여 측정한 유량의 상대오차는 댐방류량 대비 -3.3% $\sim$ 27.5%로 나타나 평균11.8%의 상대오차를 보였다. 레이더 유속계 측정과 동시에 실시한 유속-면적법 측정, ADCP법 측정의 상대오차는 각각 평균 5.7%, 6.5%로 나타난 것과 비교한다면 다소 높은 오차를 보였다. 그러나 측정 시간의 경우 수위에 따라 다소 차이는 있지만 레이더 유속계를 이용하면 30분 정도의 시간이 소요되었으며, 유속면적법은 1시간 이상, ADCP법은 40분의 시간이 소요되었다. 이와 같이 레이더 유속계는 다른 방법에 비해 정확성은 다소 떨어지지만 측정 속도와 안정성 면에서는 우수하다고 판단된다. 문제점으로 지적되는 정확도 측면의 경우 레이더 유속계로 측정되는 표면유 속과 평균 유속 사이의 보정계수 문제를 보완한다면 보다 정확한 측정이 가능할 것으로 판단된다.

  • PDF

A comparative study on discharge measurement using multi-point radar surface velocity meter (다회선 표면유속 측정시스템을 이용한 유량측정 비교 연구)

  • Yeong Seon Yun;Sang Uk Cho;Se Hwan Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.369-369
    • /
    • 2023
  • 표면유속계는 비접촉식으로 하천의 유량을 측정하는 방식이기 때문에 효율적이며, 특히 홍수발생시 안전한 측정이 가능하다. 이러한 비접촉식 방식이 갖는 장점으로 인해 홍수기 측정에 표면유속계가 널리 활용되고 있다. 하지만 포인트 방식의 표면유속계의 경우에도 측점마다 측정장비를이동하는 과정에서 어느 정도의 측정시간이 소요되며, 측정 시마다 기본적으로 최소 2~3인의 인력을 필요로 한다. 최근 발생하는 홍수사상은 돌발강우에 의해 발생할 뿐만 아니라 단시간 내에 급격한 수위 및 유량변화가 발생하기 때문에 대응하기 매우 어려우며 특히, 야간에 발생하는 호우사상은 야간측정에 따른 안전 사고가 발생할 우려가 있다. 따라서 본 연구에서는 홍수 시 유량측정에 효율적으로 대응할 수 있는 방안으로 다회선 표면유속계를 이용한 유량측정방법을 실제 하천에 적용하고 표면유속을 이용한 다양한 유량산정방법을 실측결과와의 비교를 통해 적용성을 검토하였다. 표면유속계는 다회선 구성이 가능한 레이다유속계(RQ-30) 5대를 활용하였으며, 금강 본류에 위치한 세종시(햇무리교) 관측소를 대상으로 홍수기 유량측정을 수행하였다. 표면유속을 이용한 유량산정방법으로는 5개 유속계의 측정구간을 합산하는 중간단면적법과 표면유속을 지표로하는 지표유속법을 적용하였으며, 유량산정 결과는 기존 관측소의 수위-유량관계의 환산유량과 ADCP를 이용한 실측유량을 비교하였다. 다회선 표면유속 측정시스템을 이용하여 유량을 산정한 결과, 중간단면적법 및 지표유속법 모두 실측치와의 상대오차가 5% 이내로 비교적 정확한 유량측정이 가능한 것으로 확인되었다. 따라서, 향후 홍수기 유량측정이 어렵거나 위험한 지점을 대상으로 홍수가 주로 발생하는 기간에 일시적으로 설치하여 활용이 가능할 것으로 판단된다.

  • PDF