• Title/Summary/Keyword: water supply plant

Search Result 358, Processing Time 0.03 seconds

Recent instrumentation system safety instrumentation and man-machine interface

  • Satake, Noboru
    • 전기의세계
    • /
    • v.25 no.6
    • /
    • pp.8-13
    • /
    • 1976
  • The industrial processes have become complicated on a large scale bacause of improvement of productivity, research of efficiency, and shortage of locations to be suited for foundation of factories. Consequently, the instrumentation and control systems for operating these industrial processes have also been highly improved with the development of mass information means. In order to operate these large-sized and complicated industrial processes safely, the man-machine interface for correspondence between man and machines and the instrumentation system regarding process fault processing are playing an important role increasingly. This paper describes recent instrumentation system in the water purifying plant as an example of these industrial processes, and covers both man-machine interface and process fault processing. The annual water supply quantity and diffusion were 2, 000, 000, 000m$^{3}$ and 25.0% in 1950 inJapan, but they amounted to 12, 000, 000, 000m$^{3}$ and 86.7% in 1974, respectively. The demands of water will increase incessantly, while it becomes gradually difficult to secure water sources. Accordingly, local self-governing bodies such as municipal cooperation, towns, and villages often construct a large-scale water purifying plant at one place in common, as required, without constructing respective plants independently. It is an absolute requirement for the water purifying plant to avoid stopping water supply to fullfil its social responsibility from the viewpoints of its public utility enterprise, and also it has gradually become difficult to secure skilled operators enough to cover such water purifying plants that are additionally provided in various districts. Thus, the importance of the man-machine interface for assuring safety operation of the water purifying plant irrespective of unskillfulness of operators as well as the instrumentation system regarding process fault processing, or, safety instrumentation, is more and more increasing as the water purifying plants are on a large scale.

  • PDF

Coliform Regrowth and Injured Coliforms in Public Water Supply (수돗물에서의 대장균군 재생장과 손상 대장균군)

  • 박성주;조재창;김상종
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.50-57
    • /
    • 1994
  • Densities of total and injured coliforms in treated water( TW ) and three tap water salt pies( Taps Kl, K2 and K3) of Ku- eui water treatment plant and one tap water sample( Tap T) of Tuk- do water treatment plant were measured 23 times from 1991 to 1992. Coliform regrowth in the water distribution system occurred three times during the study period. When the regrowth episode occurred, injured coliforms were always but total coliforms were not always detected in treated water. Mean densities of total coliforms in TW, and Taps Kl, K2, K3 and T were 0.8, 2.3, 1.9, 1.4 and 2.1 cfu/100mℓ by membrane filtration method using m- TF agar and those of injured coliforms were 3.4, 2.8, 2.5, 2.7 and 2.9 c1u/100mℓ using mondo- LES agar. The injury rates of TW and Taps Kl, K2, K3 and T were 89.5,77.4,67.9, 82.8 and 75.9%, respectively. The high injury rate of coliform bacteria in Seoul water supply can cause regrowth problems in distribution systems due to the repair of injured cells under an appropriate condition. It is recommended the injured coliforms should be measured in drinking water since they can lead to a significant underestimation of total coliforms and result in an inaccurate evaluation of the potential health risks.

  • PDF

Solar power and desalination plant for copper industry: improvised techniques

  • Sankar, D.;Deepa, N.;Rajagopal, S.;Karthik, K.M.
    • Advances in Energy Research
    • /
    • v.3 no.1
    • /
    • pp.59-70
    • /
    • 2015
  • In India, continuous production of electricity and sweet/potable water from Solar power and desalination plant plays a major role in the industries. Particularly in Copper industry, Solar power adopts Solar field collector combined with thermal storage system and steam Boiler, Turbine & Generator (BTG) for electricity production and desalination plant adopts Reverse osmosis (RO) for sweet/potable water production which cannot be used for long hours of power generation and consistency of energy supply for industrial processes and power generation cannot be ensured. This paper presents an overview of enhanced technology for Solar power and Desalination plant for Copper industry making it continuous production of electricity and sweet/potable water. The conventional technology can be replaced with this proposed technique in the existing and upcoming industries.

Effect of Irrigation Water Pollution on the Nutrition Physiology of Rice Plant in the Kimhae Plain;Especially on the Nitrogen Supply and Yield (김해평야 관개수 오염도가 벼 영양생리에 미치는 영향;질소양분 공급과 수량을 중심으로)

  • Ha, Ho-Sung;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.8 no.2
    • /
    • pp.93-102
    • /
    • 1989
  • Water pollution status of the irrigation water, inorganic nutrient contents of rice plant, relationship between water quality of irrigation water and inorganic nutrient contents of rice plant, and nitrogen supply by irrigation water at six sites of pumping stations in Kimhae plain were investigated. The results were as follows : 1. Average values of water components analyzed at all pumping stations were in the range of 6.5-7.0 pH, 0.6-7.7ppm DO, 4.4-63.5ppm BOD, 7.3-73.9ppm COD, 1.84-16.22ppm $NH_4$-N, 1.22-15.49ppm $NO_3$-N and 0.07-1.35ppm $PO_4$-P respectively. 2. Comparatively heavy polluted sites were Sikman, Bongrim and Noksan, and less polluted sites were Daejeo, Myeongje and Jangyou, judging from BOD, COD and $NH_4$-N of the irrigation water. 3. Nitrogen supply by irrigated water for a year were 6.82Kg/10a, 5.98Kg/10a, 6.64Kg/10a, 2.31kg/10a, 6.22Kg/10a and 2.54Kg/10a in Daejeo, Sikman, Bongrim, Myeongji and Noksan area, respectively. 4. Positive correlation was observed between ammonium nitrogen of the water and total nitrogen contents of rice plant. Total nitrogen contents of rice plant were higher in Sikman, Borgim and Noksan area than in the other areas.

  • PDF

Purification process and reduction of heavy metals from industrial wastewater via synthesized nanoparticle for water supply in swimming/water sport

  • Leiming Fu;Junlong Li;Jianming Yang;Yutao Liu;Chunxia He;Yifei Chen
    • Advances in nano research
    • /
    • v.15 no.5
    • /
    • pp.441-449
    • /
    • 2023
  • Heavy metals, widely present in the environment, have become significant pollutants due to their excessive use in industries and technology. Their non-degradable nature poses a persistent environmental problem, leading to potential acute or chronic poisoning from prolonged exposure. Recent research has focused on separating heavy metals, particularly from industrial and mining sources. Industries such as metal plating, mining operations, tanning, wood and chipboard production, industrial paint and textile manufacturing, as well as oil refining, are major contributors of heavy metals in water sources. Therefore, removing heavy metals from water is crucial, especially for safe water supply in swimming and water sports. Iron oxide nanoparticles have proven to be highly effective adsorbents for water contaminants, and efforts have been made to enhance their efficiency and absorption capabilities through surface modifications. Nanoparticles synthesized using plant extracts can effectively bind with heavy metal ions by modifying the nanoparticle surface with plant components, thereby increasing the efficiency of heavy metal removal. This study focuses on removing lead from industrial wastewater using environmentally friendly, cost-effective iron nanoparticles synthesized with Genovese basil extract. The synthesis of nanoparticles is confirmed through analysis using Transmission Electron Microscope (TEM) and X-ray diffraction, validating their spherical shape and nanometer-scale dimensions. The method used in this study has a low detection limit of 0.031 ppm for measuring lead concentration, making it suitable for ensuring water safety in swimming and water sports.

Mechanism Investigation and Measures on Acoustic Vibration Phenomena of Water Supply Piping (급수 배관계의 음향진동 현상 고찰 및 대책)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Lee, Doo-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.470-475
    • /
    • 2012
  • The downstream piping system of the water supply system in a supercritical power plant is affected by the fluctuation pressure waves induced by accessing to the acoustic modes of the piping systems with the rotation and impeller passing pulsations of the feed water pump. There are the phenomena amplified at the same time in the range of 415 ~ 455Hz, 830 ~ 910Hz, 1245 ~ 1365Hz and 1660 ~ 1820Hz on the spectrums of the vibration, the sound pressure, and the pressure fluctuation waves.

  • PDF

A Study on Output Increase of Small Hypro Power using Nature Energy (자연에너지를 이용한 소수력 출력증대 방안 연구)

  • Chae, Ji-Seog;Yoon, Lee-Soo;Kim, Tae-Ho;Kim, Young-Il;Ma, Bem-Gu;Choi, Jang-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1129-1130
    • /
    • 2011
  • The output of small hydro power plant was generated less than rated output under high temperature. We Installed the artificial ventilation that blow cold wind from water supply pipe tunnel to small hydro power plant. The temperature of small hydro power has been decreased. The output of small hydro power plant has been increased from 405kW to 445kW.

  • PDF

Development of a System Dynamics Computer Model for Efficient Operations of an Industrial Water Supply System (공업용수 공급시스템의 효율적인 운영을 위한 시스템다이내믹스 모형의 개발)

  • Kim, Bong-Jae;Park, Su-Wan;Kim, Tae-Yeong;Jeon, Dae-Hun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.383-397
    • /
    • 2012
  • In this study, a System Dynamics (SD) simulation model for the efficient operations of an industrial water supply system was developed by investigating the feedback loop mechanisms involved in the operations of the system. The system was modeled so that as demand is determined the water supply quantity of intake pumping stations and dams are allocated. The main feedback loop showed that many variables such as the combinations of pump operation, unit electric power(kWh/$m^3$), unit electric power costs(won/$m^3$), water level of water way tunnel, suction pressure and discharge of pumping station, and tank and service reservoir water level had causal effects and produced results depending on their causal relationship. The configurations of the model included an intake pumping station model, water way tunnel model, pumping station model (including the tank and service reservoir water level control model), and unit electric power model. The model was verified using the data from the case study industrial water supply system that consisted of a water treatment plant, two pumping stations and four dams with an annual energy costs of 5 billion won. It was shown that the electric power costs could have been saved 7~26% during the past six years if the operations had been based on the findings of this study.

Application of HACCP principles to MAR-based drinking water supply system (MAR기반 음용수 공급 시스템에의 HACCP 원리 적용)

  • Ji, Hyon Wook;Lee, Sang-Il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.533-543
    • /
    • 2016
  • Supplying clean and safe water to people is facing both quantitative and qualitative challenges. Due to climate change, access to freshwater becomes increasingly difficult, while pollution from various sources decreases the public trust in water quality. Managed aquifer recharge (MAR) which stores and uses surface water in aquifer is receiving attention as a new technology to secure freshwater. Recently, there is a global expansion in the attempt to combine general purification plants and hazard analysis and critical control point (HACCP) which manages all the process from raw material to consumer for food safety. This research is about an attempt to apply HACCP to the drinking water supply process using MAR to secure both quantity and quality of drinking water. The study site is a MAR plant being constructed in the downstream area of the Nakdong River Basin, South Korea. The incorporation of HACCP with MAR-based water supply system is expected to enhance the safety and reliability of drinking water.

Demonstration study on Desalination System using Solar energy (태양에너지 해수담수화시스템 실증)

  • Kim, Jeong-Bae;Joo, Hong-Jin;Yoon, Eung-Sang;Joo, Moon-Chang;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.27-33
    • /
    • 2007
  • In this research, to develop the practical application system of fresh water generation system with plate-type fresh water generator using low pressure evaporation method is the main object, and to do that, this study used the evacuated solar collector with operating range of about $50-85^{\circ}C$ as thermal energy source and solar photovoltaic as electric energy source. To achieve that object, this study set up the demo-plant, then estimated and analyzed the usefulness, the safety, and the reliability through pre-tests during short time ahead of the long-time operation. This study showed that the pumps, which are including sea water supply, ejector, hot water supply, and fresh water pumps, were operated one after another. And, the fresh water yield was closely related with the solar irradiance and lower supply temperature of hot water was revealed more reasonable for the solar energy desalination system. That is due to the insufficient area than the solar collector area being required that was estimated through the performance tests of the fresh water generator.