• 제목/요약/키워드: water supply performance

검색결과 464건 처리시간 0.024초

공동주택의 제로카본 그린홈을 위한 신재생에너지 하이브리드 열공급 시스템의 열성능 분석 (Thermal Performance Analysis of Renewable Hybrid heat Supply System for Zero Carbon Green Home of Apartment)

  • 주홍진;이경호;곽희열
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.451-456
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000 kacal/hr, a evacuated tubular solar collector 3.74 $m^2$ of aperture area at the $20^{\circ}$ install angle, a 0.3 $m^3$ hot water storage tank, a 0.15 $m^3$ hot water storage tank for space heating. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

  • PDF

물 부족량 공급 운영 방식에 의한 다목적댐 물 공급의 안정성 평가 (Performance Evaluation of Water Supply for a Multi-purpose Dam by Deficit-Supply Operation)

  • 이동률;문장원;최시중
    • 한국수자원학회논문집
    • /
    • 제47권2호
    • /
    • pp.195-206
    • /
    • 2014
  • 본 연구에서는 물 부족량 공급 운영 방식(deficit-supply)에 의해 다목적댐을 모의 운영하고 그 결과 얻어진 저수량을 기반으로 댐별 물공급의 안정성을 평가할 수있는 방법을 제시하였다. 본 연구에서 제안한 방법을 16개 다목적댐에 적용하였으며, 그 결과를 통해 댐별 물 공급 안정성을 평가하였다. 평가 결과, 소양강댐, 충주댐, 횡성댐, 안동댐, 임하댐 및 합천댐의 안정성이 가장 높은 것으로 나타났으며, 섬진강댐과 부안댐의 안정성이 상대적으로 낮은 것으로 평가되었다. 특히 부안댐은 신뢰도, 회복도, 취약도에 있어 가장 낮은 수준의 평가 결과를 나타내고 있어 물 공급 안정성을 향상시키기 위한 대책이 필요한 것으로 나타났다.

소독능을 고려한 송수펌프 최적운영기법 개발 (Development of the method for optimal water supply pump operation considering disinfection performance)

  • 형진석;김기범;서지원;김태현;구자용
    • 상하수도학회지
    • /
    • 제32권5호
    • /
    • pp.421-434
    • /
    • 2018
  • Water supply/intake pumps operation use 70~80% of power costs in water treatment plants. In the water treatment plant, seasonal and hourly differential electricity rates are applied, so proper pump scheduling can yield power cost savings. Accordingly, the purpose of this study was to develop an optimal water supply pump scheduling scheme. An optimal operation method of water supply pumps by using genetic algorithm was developed. Also, a method to minimize power cost for water supply pump operation based on pump performance derived from the thermodynamic pump efficiency measurement method was proposed. Water level constraints to provide sufficient disinfection performance in a clearwell and reservoirs were calibrated. In addition, continuous operation time constraints were calibrated to prevent frequent pump switching. As a result of optimization, savings ratios during 7 days in winter and summer were 4.5% and 5.1%, respectively. In this study, the method for optimal water pump operation was developed to secure disinfection performance in the clearwell and to save power cost. It is expected that it will be used as a more advanced optimal water pump operation method through further studies such as water demand forecasting and efficiency according to pump combination.

비상시 용수 연계공급 성능의 시·공간적 평가를 위한 A-PDA 모형 및 공급성능지표의 적용 (An application of the A-PDA model and the water supply performance index for the temporal and spatial evaluation of the performance of emergency water supply plans via interconnections)

  • 옥수연;김수리;전환돈
    • 한국수자원학회논문집
    • /
    • 제51권11호
    • /
    • pp.977-987
    • /
    • 2018
  • 상수관망시스템의 운영목적은 탄력성을 높여 각종 비정상상황에 유연하게 대처할 수 있는 방향으로 점차 변화하고 있으며 이에 따라 비정상상황에 따른 단수구역 발생에 대한 사후대책 대비를 통한 탄력성 향상이 필수적이다. 이를 위한 가장 효율적인 방법은 수계전환에 따른 비상공급 수원확보이며, 비상관로를 통하여 인접 배수블록으로부터 단수된 구역에 용수를 공급할 수 있다. 성공적인 비상연계 운영을 위해서는, 수리학적 해석을 통하여 시공간적인 측면에서의 공급성능을 평가해야 한다. 비상연계 시, 공간적인 범위를 결정하는 주요 요소는 관경, 위치 및 관저고와 같은 비상관로에 해당하는 제원이며, 시간적인 범위를 결정하는 주요 요소는 연계배수지의 용량과 정수장에 공급 가능한 추가수량이다. 본 연구에서는 A시의 상수관망에 대하여 배수지 1지에 문제가 발생하여 타 배수지들로부터 비상연계를 받는 시나리오에 대하여 모의를 진행하였다. 배수지의 저류량 및 유입량에 대한 모의를 위하여 Advanced-Pressure Driven Analysis 모형을 사용하였으며, 수리해석 결과를 바탕으로 공급범위기준지표 및 공급시간기준지표를 산정하여 연계공급성능에 대한 다각도적인 평가를 진행하였다. 이에 비상연계에 대하여 소비자들이 실제 체감하는 공급성능을 시공간적인 측면에서 파악할 수 있었으며, 설계제원의 타당성에 대한 검토가 가능하였다. 이는 비상연계 성능향상을 위한 구조적 대책 및 비구조적 대책 수립에 대한 의사결정에 용이하게 활용될 수 있을 것으로 기대한다.

바닥복사 난방시스템의 공급온수특성에 따른 에너지 소비특성 연구 (The Effects of Hot Water Supply on Energy Consumption for Floor Radiant Heating System)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.32-38
    • /
    • 2019
  • In this study, the effect of hot water supply flow rates on energy consumption for radiant floor heating system in apartment were researched by computer simulation. The parametric study of different hot water supply flow rates was done with regard to energy performance and control characteristics, respectively. Also the effect of different hot water supply flow rates on the hot water supply temperatures is studied. As a result, energy consumption were reduced but the response time is increased by reducing the supply flow rate. And energy consumption can be saved by adjusting the hot water supply temperatures with different supply flow rates.

다목적댐의 응수공급능력 평가지표 산정에 관한 연구 (A Study on Estimate of Evaluation Indices of Water Supply Capacity for Multipurpose Dam)

  • 차상화;박기범
    • 한국환경과학회지
    • /
    • 제13권3호
    • /
    • pp.197-204
    • /
    • 2004
  • In this study analyzed the reliability indices against the water supply ability of Andong dam. The water supply analysis of Andong dam used the HEC-5 model. So Andong dam simulated planed water-supply capacity of Andong dam as increase and decrease +5% ~ -5% of water supply quantity. Water-supply capacity of Andong dam estimated, deficit occurrence, deficit quantity, deficit period. As the results estimated reliability(occurrence based, time based, quantity based) and resiliency vulnerability and with water supply capacity evaluation indices of Andong dam. Also reliability(occurrence based, time based, quantity based), resiliency, vulnerability and resiliency indices are estimated to evaluated the performance of water supply on Andong dam, and their relationships are evaluated.

중실원추형 및 중공원추형 2유체 미립화기의 화재 소화 성능 검토: 공급 기체와 미분무 영향 (Examination on Fire Extinguishing Performance of Full Cone and Hollow Cone Twin-fluid Atomizers: Effects of Supply Gas and Water Mist)

  • 김동환;이치영
    • 한국화재소방학회논문지
    • /
    • 제33권5호
    • /
    • pp.28-36
    • /
    • 2019
  • 본 연구에서는 분사 형태(Spray pattern)가 중실원추형(Full cone) 및 중공원추형(Hollow cone)인 2유체 미립화기를 이용하여 공급 기체 및 미분무가 헵탄 풀화재(Heptane pool fire) 소화 성능에 미치는 영향을 검토하였다. 2유체 미립화기의 공급 기체로 30 lpm (Liter per minute; L/min)의 공기 또는 질소를 이용하였으며, 물을 공급하지 않은 경우(즉, 공기 또는 질소만 분사한 경우)와 물 0.085 lpm을 공급한 경우(즉, 미분무와 공급 기체를 함께 분사한 경우)에 대해 실험을 수행하였다. 실험 결과, 공급 기체만 분사한 경우보다 미분무와 공급 기체를 함께 분사한 경우에, 그리고 중공원추형인 경우보다 중실원추형인 경우에 빠르게 화재 소화 가능함을 확인하였다. 또한, 중실원추형의 경우, 미분무와 공급 기체 함께 분사 시 화재 소화 성능에 미분무의 영향은 지배적이었으나 공급 기체의 영향은 미비한 것으로 관찰되었다. 반면, 중공원추형의 경우, 중실원추형과 달리 미분무와 공급 기체 함께 분사 시 공급 기체로 질소를 공급한 경우가 공기를 공급한 경우에 비해 평균 화재 소화 시간이 확연하게 짧아지는 것으로 측정되었고, 이를 통해 미분무 뿐 아니라 공급 기체도 화재 소화 성능에 지대한 영향을 미칠 수 있음을 확인하였다.

농업용 저수지 공급량과 수요량의 확률분포 및 신뢰성 해석 기법을 활용한 물 공급 취약성 평가 (Vulnerability Assessment of Water Supply in Agricultural Reservoir Utilizing Probability Distribution and Reliability Analysis Methods)

  • 남원호;김태곤;최진용;이정재
    • 한국농공학회논문집
    • /
    • 제54권2호
    • /
    • pp.37-46
    • /
    • 2012
  • The change of rainfall pattern and hydrologic factors due to climate change increases the occurrence probability of agricultural reservoir water shortage. Water supply assessment of reservoir is usually performed current reservoir level compared to historical water levels or the simulation of reservoir operation based on the water budget analysis. Since each reservoir has the native property for watershed, irrigation district and irrigation water requirement, it is necessary to improve the assessment methods of agricultural reservoir water capability about water resources system. This study proposed a practical methods that water supply vulnerability assessment for an agricultural reservoir based on a concept of probabilistic reliability. The vulnerability assessment of water supply is calculated from probability distribution of water demand condition and water supply condition that influences on water resources management and reservoir operations. The water supply vulnerability indices are estimated to evaluate the performance of water supply on agricultural reservoir system, and thus it is recommended a more objective method to evaluate water supply reliability.

고분자 전해질 연료전지의 수소극 공급모드에 따른 성능특성 (Performance Characteristics of a Polymer Electrolyte Fuel Cell with the Anodic Supply Mode)

  • 이용택;박차식;허재혁;김용찬
    • 대한기계학회논문집B
    • /
    • 제31권7호
    • /
    • pp.588-595
    • /
    • 2007
  • The water transport inside a polymer electrolyte fuel cell (PEFC) varied according to the anodic supply mode. The performance characteristics of a PEFC which can be affected by the water transport were observed with the anodic supply mode. In the flow-through and recirculation mode the performance showed no reduction with time because the flow in the anode was not stagnated. In the dead-end mode, without any discharged gas, the water remains inside of the anode, which caused the reduction of the performance with the lapse of time. However, even in the dead-end mode, little reduction of the performance with time was shown when only the anode was humidified externally. It means that the back-diffusion was the major factor to the accumulation of water in the anode rather than external humidification.

제로카본 그린홈 구현을 위한 하이브리드 열공급 시스템의 열성능 분석 (Thermal Performance Analysis of Hybrid heat Supply System for Zero Carbon Green Home)

  • 주홍진;이경호;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.53-59
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000kcal/hr, a $0.15m^3$ hot water storage tank for space heating, a evacuated tubular solar collector $3.74m^2$ of aperture area at the $20^{\circ}$ install angle, a $0.3m^3$ hot water storage tank. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.