Properties of Water Substitute Solid Phantoms for Electron Dosimetry

  • Saitoh, Hidetoshi;Tomaru, Teizo;Fujisaki, Tatsuya;Abe, Shinji;Myojoyama, Atsushi;Fukuda, Kenichi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.255-259
    • /
    • 2002
  • To reduce the uncertainty in the calibration of radiation beams, absorbed dose to water for high energy electrons is recommended as the standards and reference absorbed dose by AAPM Report no.51 and IAEA Technical Reports no.398. In these recommendations, water is, defined as the reference medium, however, the water substitute solid phantoms are discouraged. Nevertheless, when accurate chamber positioning in water is not possible, or when no waterproof chamber is available, their use is permitted at beam qualities R$\_$50/ < 4 g/cm$^2$ (E$\_$0/ < 10 MeV). For the electron dosimetry using solid phantom, a depth-scaling factor is used for the conversion of depth in solid phantoms to depth in water, and a fluence-scaling factor is used for the conversion of ionization chamber reading in plastic phantom to reading in water. In this work, the properties, especially depth-scaling factors c$\_$p1/ and fluence-scaling factors h$\_$pl/ of several commercially available water substitute solid phantoms were determined, and the electron dosimetry using these scaling method was evaluated. As a result, it is obviously that dose-distribution in solid phantom can be converted to appropriate dose-distribution in water by means of IAEA depth-scaling.

  • PDF

Contribution of light in high-energy film dosimetry using water substitute phantoms

  • Fujisaki, Tatsuya;Saitoh, Hidetoshi;Hiraoka, Takeshi;Kuwabara, Akio;Abe, Shinji;Inada, Tetsuo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.272-274
    • /
    • 2002
  • The contribution of light in high-energy film dosimetry was examined using six commercially available solid water substitute phantoms. As six commercially available phantoms; RMI-451, Mix-DP, WE211, WE211-Black, PMMA and PMMA Black were evaluated in this study. It is difficult to evaluate the contribution of Cerenkov radiation and the optical permeability to the relative and/or absolute dosimetry using unpacked film in these phantoms. Therefore the contribution of Cerenkov radiation was estimated by the comparison between film densities in the shielded side (shutting off the light) and unshielded sides on a phantom. The effect of optical permeability was measured under ambient light by the time scale method. The results suggest that the use of black colored phantoms may improve the accuracy of dose measurement in film dosimetry.

  • PDF

선형가속기의 품질관리를 위한 2차원이온전리함배열의 유용성 (Feasibility of Two Dimensional Ion Chamber Array for a Linac Periodic Quality Assurance)

  • 이정우;홍세미;박병문;강민영;김유현;서태석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권2호
    • /
    • pp.183-188
    • /
    • 2008
  • 본 연구의 목적은 방사선치료용 선형가속기의 품질관리를 수행하기 위한 2차원이온전리함배열의 유용성을 검증하기 위함이다. 물팬톰과 필름으로 수행하던 기존의 품질관리 방법을 2차원이온전리함배열(MatriXX, Wellhofer Dosimetrie, Germany)을 이용하여 유용성을 검증하였다. MatriXX는 1,020개의 평판형 전리함(용적: $0.08\;cm^3$, 직경: 4.5mm, 높이: 5mm, 배열간격: 7.62mm)이 일정한 간격으로 $24{\times}24\;cm^2$의 면적에 배열 되어있다. MatriXX의 유용성을 검증하기 위해 연속된 5개월에 걸쳐 선량균등도, 에너지($TPR_{20,10}$), 그리고 절대 선량을 측정하여 물팬톰과 $0.65\;cm^3$ (FC65G, Wellhofer Dosimetrie, Germany) Farmer형 이온전리함을 통해 얻은 값과 비교, 분석하였다. MatriXX 측정 시 폴리스틸렌 고체 팬톰(${\rho}:\;1.18\;g/cm^3$)을 이용하였으며, MatriXX 고유의 커버 물질의 밀도와 두께(${\rho}:\;1.06\;g/cm^3$, t: 0.36 cm)를 물과 등가의 값으로 환산하여 적용하였다. 또한, 기하학적 점검을 위한 예비실험에서 콜리메이터의 회전축과 하프빔의 접합부를 필름측정의 결과와 비교하였다. 선량계측학적 실험 결과, MatriXX로 얻은 데이터와 물팬톰의 결과가 모든 항목에서 ${\pm}1%$ 이내의 일치를 보였다. 기하학 품질관리의 예비 실험 결과 기존의 필름방식과 유사한 결과를 얻었으며, 기하학적 품질관리의 정량적 분석 가능성을 제시하였다. 본 연구를 통해 주기적인 선형가속기의 품질관리에서 물팬톰과 필름을 대체할 수 있는 MatriXX의 유용성을 확인하였으며, 향후 비용절감과 시간과 인력을 절감할 수 있는 품질관리의 새로운 방법을 제시하였다.

  • PDF

Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans

  • Shokri, Abbas;Ramezani, Leila;Bidgoli, Mohsen;Akbarzadeh, Mahdi;Ghazikhanlu-Sani, Karim;Fallahi-Sichani, Hamed
    • Imaging Science in Dentistry
    • /
    • 제48권1호
    • /
    • pp.31-39
    • /
    • 2018
  • Purpose: This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from cone-beam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. Materials and Methods: A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values(MGVs) of each cylinder were calculated in each imaging protocol. Results: In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes(P<.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. Conclusion: The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.

Electronic Portal Imaging Device(EPID)의 유용성 평가 (The evaluation of usefulness of Electronic Portal Imaging Device(EPID))

  • 이양훈;김보겸;정치훈;이제희;박흥득
    • 대한방사선치료학회지
    • /
    • 제17권1호
    • /
    • pp.19-31
    • /
    • 2005
  • 목적 : 방사선치료 시 자세 및 치료부위의 재현성을 유지하기 위해 Port film을 통한 정도관리가 이루어져 왔으며 Mega Voltage Imaging (MVI) System(mvis)이 출현한 이후로 많은 발전을 이루어 현재는 필름과 Electronic portal Image Device(EPID)를 통한 정도관리가 함께 이루어지고 있다. 이에 본 논문에서는 현재 사용하고 있는 EPID 시스템의 소개와 amorphous silicon (aSi) type EPID가 Intersity Modulated Radiation Therapu(IMRT)에서 film dosimetry를 대체할 수 있는지에 대한 가능성을 분석하였다. 대상 및 방법 : Varian 21EX의 aSi type EPID와 Varian 6EX의 LC type EPID를 통해 FDD, Gantry 회전에 따른 재현성 분석과 EPID 출/입시 FDD에 따른 시간분석을 하였으며 Alderson Rando phantom을 이용하여 Couch & Gantry rotation에 따른 영상획득 가능범위를 분석하였다. aSi type EPID를 대상으로 Las Vegas phantom과 물팬텀으로 공간분해능과 대조도 분해능을 비교하였으며 Dynamic Multileaf collimator(DMLC)영상에 대해 저감도 측정용 필름과 EPID로 분석하여 IMRT의 정도관리 적용가능성을 시험하였다. 결과 : aSi type EPID와 LC type EPID 재현성은 출/입시 1mm 이내로 우수하게 나타났으나 Gantry 회전에 따른 재현성은 각각 ${\pm}3\;mm,\;{\pm}2\;mm$였으며 EPID의 출/입시 focus detector distance(FDD)에 따른 시간분석은 14초에서 17초로 측정되었다. Las Vegas phantom을 이용한 공간분해능과 대조도분해능 비교 시 표면과 물 팬텀 10, 20 cm 깊이에서 측정해 보았을 때 EPID가 선량율과 영상획득시간, 영상획득방법, frame수에 따라 달라짐을 확인할 수 있었으며, EPID로 영상획득 가능 범위를 분석해보면 film보다 손쉬운 측정이 가능한 것으로 나타났다. 저감도측정용 필름과 EPID를 통해 DMLC측정을 통한 IMRT 정도관리 결과 필름과 같은 값을 나타내었다. 결론 : EPID에 관한 여러 가지 평가를 통한 적절한 정보제공을 통해 EPID 사용, 관리 시 필요한 정보를 획득 할 수 있었으며 EPID를 통해 얻은 영상이 digital data라는 점에 착안해 적절한 정도관리가 어려운 IMRT의 분야에서 필름을 통한 주기적 점검의 대체수단으로 사용가능성이 있음을 알 수 있었다. 특히 point-dose 측정시 사용하는 diode나 전리조(lonization chamber)를 통해 평가하기 어려운 IMRT의 sliding window영상에 대한 적절한 평가와 MLC에서 leaf사이의 누설선량과 소조사면에서의 DMLC 움직임에 대한 정확한 평가가 기대된다.

  • PDF

방사선 치료에서 3D 프린터로 제작된 금속 필라멘트의 투과율에 관한 유용성 평가 (Evaluation of the Usefulness of the Transmittance of Metal Filaments Fabricated by 3D Printers in Radiation Therapy)

  • 권경태;장희민;윤명성
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.965-973
    • /
    • 2021
  • 방사선 치료는 고에너지 X선을 최소 20 Gy에서 80 Gy까지 다양하게 조사되기 때문에 종양이 위치하는 국소부위에 고선량을 투여하며 일부 정상조직의 여러 부작용이 예상 된다. 현재 임상에서는 정상조직의 차폐를 위한 노력으로 대표적인 재료인 납을 사용하고 있지만 납은 인체에 유해한 중금속으로 분류되고 있으며 다량의 피부접촉은 중독을 유발할 수 있다. 따라서 본 연구는 FDM(Fused Deposition Modeling)방식의 3차원 프린터의 재료 Tungsten, Brass, Copper을 이용하여 납의 한계점을 보완 할 수 있는 측정시트를 제작하고 투과성능을 알아보고자 한다. 3D 프린터를 이용해 Tungsten 혼합 필라멘트 투과측정 시트 크기는 70 × 70 mm, 두께는 1, 2, 4 mm로 제작하였으며 제작한 측정시트의 투과성능을 확인하기 위해 선형가속기 (TrueBeam STx, S/N: 1187)에서 발생된 6, 15 MV을 Water Phantom과 Ion chamber (FC-65G), elcetrometer (PTW UNIDOSE)을 사용하여 SSD 100 cm, 물 속 5 cm에서 100 MU를 조사하여 측정하고 투과성능을 평가하였다. 각 소재의 측정시트를 1 mm씩 증가시킨 결과 6 MV에서는 Tungsten 시트의 경우 3.8~3.9 cm일때의 시트는 기존 납의 차폐체 두께 6.5 cm 보다 얇으며, 15 MV에서는 Tungsten 시트의 경우 4.5~4.6 cm일 때 시트는 기존 납의 차폐체 두께 7 cm 보다 얇으며 동등한 성능을 확인할 수 있었다. 본 연구를 통하여 Tungsten 합금 필라멘트을 이용하여 제작한 투과측정 시트는 고에너지 영역에서의 투과 차폐 가능성을 확인하였으며. 대체품으로써의 사용가능성 또한 우수함을 확인하였다, 향후 3D 프린팅 기술로 차폐제 제작을 위한 기초자료로 제공할 수 있을 것으로 사료 된다.