• Title/Summary/Keyword: water spray head

Search Result 27, Processing Time 0.03 seconds

A Study on Improvement of Discharge Obstruction Prevention Standard for Sprinkler Head on NFSC 103 (스프링클러설비 소화성능 향상을 위한 NFSC 103 살수장애 방지기준 개선 방안에 관한 연구)

  • Kim, Sunghyun;Lee, Sungsu
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.237-247
    • /
    • 2020
  • Purpose: This study aims to draw the problems and improvements of NFSC 103 sprinkler head discharge obstruction prevention standard to increase the fire extinguishing performance of sprinkler system in order to contribute to the protection of people's lives and property in the event of a fire. Method: NFSC 103 was compared to NFPA 13 which is the latest 2019 version in U.S in terms of sprinkler head discharge obstruction prevention. Results: This study found that NFSC 103 doesn't define even the basic concept of sprinkler discharge obstruction. And NFSC 103 doesn't have detailed standard for side wall sprinkler head discharge obstruction prevention as well as the "height" criteria of the "three times" separation rule. Conclusion: NFSC 103 needs a lot of supplements and improvements such as the addition of definition for water discharge obstructions, the adoption of sidewall sprinkler heads standard for preventing water discharge obstructions and the additional establishment of the "three times rule" considering the "height" of obstacles to promote the advance of fire safety standard equal or above fire fighting advanced country and increase the reliability for the suppression performance of sprinkler system.

A Study on the Cleaning Device of Bidet Washer (비데 세정기의 세척장치에 관한 연구)

  • Lim, Yeon-Jeong;Lim, Sang-Ho
    • Industry Promotion Research
    • /
    • v.4 no.1
    • /
    • pp.21-27
    • /
    • 2019
  • This study is about the bidet which is used to clean the anal and local parts after the user seated on the left side of the toilet in the toilet. The cleaner of the bidet which is contaminated from various bacteria and dirt is washed clean with clean water to keep it clean The present invention relates to a cleaning device for a bidet cleaner that hygienically maintains a bidet used by a plurality of users. As a result of developing and studying a bidet nozzle that can be implemented with a bidet nozzle and a washing nozzle for automatically washing the jetting head of the bidet and the jetting head, the optimum jetting time of the nozzle after the hydraulic jetting is 1 second To 10 seconds, it was confirmed that the nozzle cleanliness of an average of 5 seconds was maintained at 100%. Subsequent studies will require further study of the durability of the product and the cleaning safety at a pressure of $5kg/mm^2$. Toilet bidet is a product that is closely related to the safety and life of the people, but the development of various technologies is still insufficient. Therefore, it is meaningful that this study contributed to the quality of life of the people by continuously researching and developing the bidet.

AN EXPLORATORY STUDY OF THE EMISSION REDUCTION TECHNOLOGIES COMPLIANT WITH SULEV REGULATIONS

  • Kim, In Tak;Lee, Woo Jik;Yoon, Jong Seok;Park, Chung Kook
    • International Journal of Automotive Technology
    • /
    • v.2 no.2
    • /
    • pp.63-75
    • /
    • 2001
  • This paper describes the development of THC reduction technologies compliant with SULEV regulations. Technologies embodied by the developmental work include improvement of fuel spray atomization, quick warm-up through coolant control shut of, and acceleration of fuel atomization for the fast rise of cylinder head temp inside the water jacket as well as the improvement of combustion state. The technologies likewise entail reduced HC while operating in lean A/F condition during engine warm-up with the cold lean burn technology, individual cylinder A/F control for improvement of catalytic converting efficiency, after-treatment such as thin-wall catalyst, HC-adsorber and EHC and etc, through vehicle application evaluation in cold start. We carried out an experimental as well as a practical study against SULEV regulations, and the feasibility of adopting these items in vehicle was likewise investigated.

  • PDF

Clinical Efficacy of Latex Cover for Dental Handpiece (치과 핸드피스용 감염방지구의 임상적 효용성)

  • Lee, Ki-Ho;Paek, Dong-Heon
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.3
    • /
    • pp.237-245
    • /
    • 2009
  • The purpose of this study was to investigate the clinical efficacy of latex cover developed for dental handpiece on contamination of microorganisms during dental treatment and to determine whether it can be an alternative to conventional sterilization such as autoclaving. E. fecaelis was used as a experimental microorganism instead of oral flora. Experimental bowl with 2 cm of rectangular cavity was fabricated for handpiece operating instead of oral cavity. Latex covers ($Orokeeper^{(R)}$, Orobiotech Co., Korea) and several handpieces were used after sterilization by autoclave. Four experiments were performed to evaluate bacterial contamination related with (1) various parts of dental handpiece, (2) swabbing time with alcohol sponge, (3) postoperative air-water spraying time and (4) consecutive use of latex covers without autoclaving. The results show that face of handpiece uncovered with latex cover was severely contaminated than the covered area and that most bacteria were removed by swabbing face and head area of dental hand-piece and by air-water spraying more than 15 seconds nearly up to the level of sterilization. Conclusively it can be suggested that use of latex cover for handpiece during dental procedure, swabbing with alcohol sponge is air-water spraying for more than 15 seconds after use of dental handpiece should be very useful and practical for prevention of cross infection and should be an alternative method for the sterilization of dental handpiece under some difficult situations not being able to sterilize a handpiece with autoclave.

An Improvement of Fire Safety Code for Rack-Type Warehouse in Korea (국내 랙크식 창고의 방화관련 규정 개선에 관한 연구)

  • Kim, Woon-Hyung;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.69-75
    • /
    • 2014
  • Recently Amore pacific rack-type warehouse fire broke out and argue an urgent improvement of fire protection design code including automatic sprinkler and detection design. Various type of commodities have their unique fire characteristics from fire spread rate and heat lease rate and fire hazard depends on storage height, rack arrangement, aisle width, fire load etc. With increasing ceiling height for more storage space prevent effective water spray of sprinkler head, also delays detection time causes failure of early suppression. To achieve fire protection code performance of this occupancy, Major code articles relating to a classification of commodity, sprinkler system installation, detection and fire fighting are reviewed and suggested based on fire case analysis, code review between country and field survey.

Reduction of Microbial Populations on the Surface of Fresh Ginseng by Various Washing Treatments (세척처리에 따른 수삼 표면의 미생물 제어효과)

  • Kim, Hee-Su;Kim, Eun-Jeong;Choi, Jeong-Hee;Hong, Seok-In;Jeong, Moon-Cheol;Kim, Dong-Man
    • Food Science and Preservation
    • /
    • v.17 no.3
    • /
    • pp.405-409
    • /
    • 2010
  • Surface cleaning is both essential and troublesome when a consumer seeks to eliminate soil attached to the surface of fresh ginseng because all ginseng purchased in the market is covered with soil, reflecting the post-harvest situation. To facilitate ginseng use at home, a fresh-cut type of ginseng is required. As a first step toward production of such ginseng, several washing and dipping treatments were investigated with respect to surface cleaning and reduction of microbial populations on fresh ginseng. In terms of microbial distribution on the surface of fresh ginseng, higher levels of viable bacteria (6.63 log CFU/each) and fungi (5.12 log CFU/each) were present on the rhizome head than on other regions of the root. Of the washing treatments tested, hand-brushing was effective for surface cleaning and to reduce microorganism levels on fresh ginseng, but use of a high-pressure water spray followed by hand-brushing was optimally effective. To further reduce the levelsof microorganisms on the surface of fresh ginseng after washing, additional dipping treatments in 70% (v/v) ethanol and electrolyzed acidic water (at pH 2.3) were somewhat effective but showed no significant differences compared with other dipping treatments tested, including a 3 ppm ozone solution, a 200 ppm sodium hypochlorite solution, or hot water at $50^{\circ}C$.

COMPARATIVE STUDIES OF THE ADHESIVE QUALITIES OF POLYCARBOXYLATE CEMENTS (카복실레이트계 시멘트의 접착력에 관한 비교 연구)

  • Lee, Han-Moo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.17 no.1
    • /
    • pp.23-34
    • /
    • 1979
  • In this study, the adhesive strength of three commercial polycarboxylate cements to ten types of dental casting alloys, such as gold, palladium, silver, indium, copper, nickel, chromium, and human enamel and dentine were measured and compared with that of a conventional zinc phosphate cement. The $8.0mm{\times}3.0mm$ cylindrical alloy specimens were made by casting. The enamel specimens were prepared from the labial surface of human upper incisor, and the dentine specimens were prepared from the occulusal surface of the human molar respectively. Sound extracted human teeth, which had been kept in a fresh condition since, extraction, were mounted in a wax box with a cold-curing acrylic resin to expose the flattened area. The mounted teeth were then placed in a Specimen Cutter (Technicut) and were cut down under a water spray, and then the flat area on the all specimens were ground by hand with 400 and 600 grit wet silicone carbide paper. Two such specimens were then cemented together face-to-face with freshly mixed cement, and moderate finger pressure was applied to squeeze the cement to a thin and uniform film. All cemented specimens were then kept in a thermostatic humidor cabinet regulated at $23{\pm}2^{\circ}C.$ and more than 95 per cent relative humidity and tested after 24 hours and 1 week. Link chain was attached to each alloy specimen to reduce the rigidity of the jig assembly, and then all the specimens were mounted in the grips of the Instron Universal Testing Machine, and a tensile load was delivered to the adhering surface at a cross head speed of 0.20 mm/min. The loads to which the specimens were subjected were recorded on a chart moving at 0.50 mm/min. The adhesive strength was determined by measuring the load when the specimen separated from the cement block and by dividing the load by the area. The test was performed in a room at $23{\pm}2^{\circ}C.$ and $50{\pm}10$ per cent relative humidity. A minimum of five specimens were tested each material and those which deviated more than 15 per cent from the mean were discarded and new specimens prepared. From the experiments, the following results were obtained. 1) It was found that the adhesive strength of the polycarboxylate cement to all alloys tested was considerably greater than that of the zinc phosphate cement. 2) The adhesive strength of the polycarboxylate cements was superior to the non precious alloys, such as the copper, indium, nickel and chromium alloys, but it was inferior to the precious gold, silver and palladium alloys. 3) Surface treatment of the alloy was found to be an important factor in achieving adhesion. It appears that a polycarboxylate cement will adhere better to a smooth surface than to a rough one. This contrasts with zinc phosphate cements, where a rough helps mechanical interlocking. 4) The adhesion of the polycarboxylate cement with enamel was found superior to its adhesion with dentine.

  • PDF