• Title/Summary/Keyword: water rinsing

Search Result 98, Processing Time 0.028 seconds

A Study on The Effectiveness of Watertreatment Using Activated Carbons and Membranes (활성탄과 Membrane을 이용한 수처리효과에 관한연구)

  • 김영진;김영규;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.67-72
    • /
    • 1997
  • To evaluate the effectiveness of water treatment using nanofiltration, ultrafiltration, and microfiltration systems, tapwater contaminated by bacteria and nitrate nitrogen was filtered, and then the rates of removal for many kinds of contaminants were comp.ared and investigated. The rates of turbidity removal by these systems are around 80% all of them. However, nanofiltration system is the most effective as hardness removal is 80%, suspended solids 90%, total residual chlorine 90% and nitrate nitrogen 69%. Among nanofiltration, ultrafiltration and microfiltration systems, nanofiltration system is the most stable in flow rate of permeate. Comparing hollow and spiral type of ultrafiltration, microfiltration each, spiral type is more stable than hollow type owing to rinsing effect of brine. The values of pH in ultrafiltration and microfiltration systems are between 7, 0 and 7.5, and that of nanofiltration system is low to 6.2-7.0. The effectiveness of heterotrophic bacteria removal is the most excellent in the nanofiltration system.

  • PDF

A STUDY ON THE RECOMBINANT HUMAN INTERFERON ${\alpha}$A(LBD-007) FOR PRIMARY EYE AND SKIN IRRITATION IN RABBITS

  • Park, Jong-Il;Kim, Sung-Hoon;Han, Sang-Seop;Roh, Jung-Koo
    • Toxicological Research
    • /
    • v.9 no.1
    • /
    • pp.119-123
    • /
    • 1993
  • LBD-007, a newly developed recombinant human interferon ${\alpha}$A, was tested for primary eye and skin irritation in male New Zealand White rabbits. In the primary eye irritation test, 0.1ml of a solution of LBD-007 was instilled into the eye. In rinsing group, the eye was washed with water 30 seconds after instillation. No reaction was observed at the cornea, iris and conjunctivae by LBD-007. In the primary skin irritation test, LBD-007 was applied to the back of rabbits for 24 hours. Primary irritation index was "0" in test and control sites of all animals. Thus LBD-007 was evaluated as a non-irritant on the basis of the criteria of Draize et al.,(1994).

  • PDF

Determining Irrigation Requirements and Water Management Practices for Normal Growth of Dry Field Crops in Reclaimed Tidelands (간척지 밭작물의 정상생육을 위한 관개용수량 및 물 관리방법의 결정)

  • 구자웅;한강단;손재권;이동유
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.34 no.4
    • /
    • pp.80-96
    • /
    • 1992
  • This study was carried out in order to determin optimum irrigation requirements and water management practices for normal growth of dry field crops in reclaimed tidelands, and apply m planning of the irrigation projects. Desalinization experiments were performed by water management practices in the experimental field with high salt concentration, and growth experiments were conducted by irrigation point treatments using tomato and beet with relatively high salt tolerance. The results obtained from this study were summarized as follows : 1. Leaching or rinsing-leaching method was found to be effective in desalinizing the reclaimed tideland with rather high permeability. In this case, the water requirement for desalinizing the root zone layer of 40cm in depth, was estimated to be 1,200mm in depth. 2.The gypsum treatment in the desalinization of reclaimed tidelands, was ineffective in water requirements ; however, it could produce the desired effect in the facility of desalinization and the shortening of desalinization period with the sustaining permeability, in case of the desalinization by leaching method. 3.The optimum irrigation point which maintains the salt concentration within salt tolerance and maximizes the crop yield in reclaimed tidelands of silt loam soil, was found to be pF 1.6 in tomato and pF 1.8 in beet. The interval of irrigation date within 2 days was proved to he effective in both cases. 4.The optimum irrigation requirement and the water reguirement for the prevention of salt rise during the growing period after transplanting, were estimated to be 602mm(6.7mm/day) and 232mm for tomato, respectively. 5.The optimum irrigation requirement and the water requirement for the prevention of salt rise during the growing period after transplanting, were estimated to be 261mm(3.7mm/day) and 66mm for beet, respectively.

  • PDF

Stimulation of Seed Germination of Korean Lawn grass (Zoysia japonica Steud.) by Sodium Hypochlorite Treatment (Sodium Hypochlorite 처리(處理)에 의한 한국잔디 종자(種子)의 발아촉진(發芽促進))

  • Ku, Ja Hyeong;Lee, Jong Suk;Lee, Young Bok
    • Korean Journal of Agricultural Science
    • /
    • v.11 no.2
    • /
    • pp.201-206
    • /
    • 1984
  • In order to obtain an easy and effective scarification method for stimulating the seed germination of Korean lawn grass (Zoysia japonica Steud.), sodium hypochlorite (SH), which is used as a commercial bleach and a seed disinfestant, was tested as a chemical scarifier instead of potassium hydroxide (KOH). 1. Scarification with 4% SH for 2 hours followed by 8-hour water-rinse stimulated seed germination more effectively compared to generalized scarification method by KOH treatment. 2. The degree of stimulating seed gemination was different by the various water-rinsing time after SH treatment, but the optimum rinsing time was about 4 to 8 hours. 3. GA treatment after SH scarification stimulated seed germination. However, the stimulation effect of GA was not showed in non-scarified control. 4. SH treatment significantly decreased the percentage of the infection of microflora in seed samples compared to KOH treatment. 5. Under practical seed scarification conditions for stimulating germination of Korean lawn grass seed. SH may have advantages over KOH with respect to ease of preparing, securing and handling.

  • PDF

Analysis of Monitoring and Recycling Technology Technologies of Cleaning Solution and Rinse Water in the Aqeous Cleaning System (수계 세정시스템의 세정액/헹굼수의 모니터링 및 재활용 기술 분석)

  • Han, Sang-Won;Lee, Ho Yeoul;Bae, Jae-Heum;Ryu, Jong-Hoon;Park, Byeong-Deog;Jeon, Sung-Duk
    • Clean Technology
    • /
    • v.7 no.4
    • /
    • pp.225-242
    • /
    • 2001
  • Cleaning process is necessary for machining parts or manufacturing finished products in the industry. Most of domestic and foreign companies are now trying to adopt environment-friendly aqueous cleaning agents instead of CFC-113 and 1,1,1-TCE which are ozone-depleting substances. However, the aqueous cleaning system has a disadvantage due to its generation of lots of waste water since the system utilizes water in cleaning and rinsing processes. Thus, it is very important that monitoring and recycling technologies of the cleaning solution and the rinse water should be introduced in the aqueous cleaning system in order to minimize generation of waste water and to maintain its cleaning performance for a quite long time. In this paper, the cleaning agents utilized in the aqueous cleaning system and cutting oils which are main contaminants were examined and analyzed. And the monitoring and recycling technologies of the aqueous cleaning system which can be employed in the industrial fields were also reviewed and evaluated.

  • PDF

The Effects of Laundering Conditions on Calcium Deposition on the Fabric (세척조건이 직물에의 Calcium 침착에 미치는 영향)

  • Moon Young Ae;Kahng He Won;Kim Sung Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.5 no.1
    • /
    • pp.9-14
    • /
    • 1981
  • The influence of laundering conditions on calcium deposition on the fabric was studied by repeated laundering the cotton fabric with soap in the hard water of 200 P.P.M. $CaCO_3$. The experimental variables were: 1) soap concentrations ($0.06\%$, $0.13\%$, $0.25\%$), 2) water contents in the fabric after hydroextraction. ($65\%$, $150\%$, $315\%$), 3) builders (Na-EDTA, sodium carbonate, sodium metasilicate), 4) washing cycle (5, 10, 15, 20 cycles). The fabric was washed for 15 minutes at $23\pm1^{\circ}C$ in a washing machine (Model; Gold Star Wp-2005) under the similar conditions with those of home laundering, and rinsed 5 times for 5 minutes. The amount of calcium deposits on the fabric was determined by the EDTA-Back titration method described by Wasserman and Basch. Results of this study were follows: 1) The amount of calcium deposits on the fabric increased with increasing wash cycles. 2) During the rinsing process, residual calcium content on the fabric increased with water content in the fabric after hydroextraction. 3) The amount of calcium deposits on the fabric decreased with the increasing soap concentration above the equivalent amount of calcium ion content in the water. 4) Sequestering agents and alkaline builders influenced the amount of calcium deposits on the fabric. The amount of calcium deposits on the fabric was in the order of sodium metasilicate, sodium carbonate, nonbuilder, and EDTA.

  • PDF

A Study on Contact Arc Metal Cutting for Dismantling of Reactor Pressure Vessel (원자로 해체를 위한 수중 아크 금속 절단기술에 대한 연구)

  • Kim, Chan Kyu;Moon, Do Yeong;Moon, Il Woo;Cho, Young Tae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.1
    • /
    • pp.22-27
    • /
    • 2022
  • In accordance with the growing trend of decommissioning nuclear facilities, research on the cutting process is actively proceeding worldwide. In general, a thermal cutting process, such as plasma cutting is applied to decommissioning a nuclear reactor pressure vessel (RPV). Plasma cutting has the advantage of removing the radioactive materials and being able to cut thick materials. However, when operating under water, the molten metal remains in the cut plane and re-solidifies. Hence, cutting is not entirely accomplished. For these environmental reasons, it is difficult to cut thick metal. The contact arc metal cutting (CAMC) process can be used to cut thick metal under water. CAMC is a process that cuts metal using a plate-shaped electrode based on a high-current arc plasma heat source. During the cutting process, high-pressure water is sprayed from the electrode to remove the molten metal, known as rinsing. As the CAMC is conducted without using a shielding gas, such as Argon, the electrode is consumed during the process. In this study, CAMC is introduced as a method for dismantling nuclear vessels and the relationship between the metal removal and electrode consumption is investigated according to the cutting conditions.

The effect of cleaning methods on bond strength of zirconia after saliva contamination (타액으로 오염된 지르코니아 수복물의 접착강도에 세척 방법들이 미치는 영향)

  • Shim, Young-Bo;Choi, An-Na;Son, Sung-Ae;Jung, Kyoung-Hwa;Kwon, Yong Hoon;Park, Jeong-Kil
    • Korean Journal of Dental Materials
    • /
    • v.44 no.1
    • /
    • pp.61-68
    • /
    • 2017
  • This study evaluated the effects of various cleaning methods on the shear bond strength of zirconia ceramics after saliva contamination. Eighty zirconia disk specimens were divided into 8 groups. All groups were treated with one coat of MDP primer. All specimens (except the negative control) were contaminated with human saliva on the zirconia surface. The positive control went through the bonding procedure immediately after contamination without any cleaning procedure. With the exception of control groups, the remaining six groups were rinsed with water and either applied with MDP recoating (WATER+MDP) or without MDP recoating (WATER). While some were cleaned with a Ivoclean with MDP recoating (IVOCLEAN+MDP) or not applied with MDP recoating(IVOCLEAN), others were cleaned with a 1% NaOCl solution with MDP recoating (NaOCl+MDP) or without MDP recoating (NaOCl). The shear bond strength of all specimens were measured after being stored in distilled water at $37^{\circ}C$ for 24 hours. The data was analyzed statistically by an analysis of ANOVA, Tukey's post hoc test and Student's t-test was used to compare the shear bond strength according to the re-coating of MDP after the cleaning procedure. The positive control group showed the lowest shear bond strength value, and the WATER group and NaOCl group showed no significant difference when compared to the positive control group. The IVOCLEAN group showed significantly higher shear bond strength when compared to Water group and NaOCl group but not with the group of negative control. After rinsing with water or the NaOCl solution, the comparison of the single coating of MDP and re-coating of MDP showed different shear bond strengths but there was no significant difference to the negative control. After rinsing with Ivoclean, there was no significant difference to the negative control regardless of the recoating of MDP. In conclusion, the shear bond strength was affected by the cleansing procedure and Ivoclean was found to be effective regardless of the re-coating of MDP. When water or the NaOCl solution is used to remove surface contaminants, the re-coating of MDP provides a positive effect on cementation.

Study on the laundry behavior according to the number of household and the type of washer (세대구성원수와 세탁기 종류에 따른 세탁행동에 관한 연구)

  • Kim, Tae-mi
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.6
    • /
    • pp.1082-1096
    • /
    • 2015
  • The purpose of this study was to examine laundry behavior according to the number of households and the type of washing machine that each household used. The data was obtained from questionnaires filled out by 417 households, which included college students living in Seoul and Gyeonggi province. The results of this study are as follows: first, according to the results of survey about the number of household members and type of washing machine that household had, one or two-person households accounted for 24.0%. Regarding the type of washing machine that each household used, there were more drum washers. In households comprised of three or more persons, a higher percentage had a machine with a pulsator. Second, with regard to the method of classifying the wash in doing the laundry, all families classified the wash according to color and textile material. Third, with regard to the amount of detergent in doing the laundry, 63.5% of households used the recommended amount of detergent while 28.3% of households used more detergent than the recommended amount. Fourth, with regard to the set temperature of water in doing the laundry, 36.2% of households used cold water; this was the highest percentage. Fifth, with regard to input sequence in doing the laundry, most households put the wash in the machine in advance, and then filled the washer with water; 56.1% of households added a rinsing process for all washing processes.

Removal of Organic Wax and Particles on Final Polished Wafer by Ozonated DI Water

  • Yi, Jae-Hwan;Lee, Seung-Ho;Kim, Tae-Gon;Lee, Gun-Ho;Choi, Eun-Suck;Park, Jin-Goo
    • Korean Journal of Materials Research
    • /
    • v.18 no.6
    • /
    • pp.307-312
    • /
    • 2008
  • In this study, a new cleaning process with a low cost of ownership (CoO) was developed with ozonated DI water ($DIO_3$). An ozone concentration of 40 ppm at room temperature was used to remove organic wax film and particles. Wax residues thicker than $200\;{\AA}$ remained after only a commercial dewaxer treatment. A $DIO_3$ treatment in place of a dewaxer showed a low removal rate on a thick wax layer of $8000\;{\AA}$ due to the diffusion-limited reaction of ozone. A dewaxer was combined with a $DIO_3$ rinse to reduce the wax removal time and remove wax residue completely. Replacing DI rinse with the $DIO_3$ rinse resulted in a surface with a contact angle of less than $5^{\circ}$, which indicates no further cleaning steps would be required. The particle removal efficiency (PRE) was further improved by combining a SC-1 cleaning step with the $DIO_3$ rinsing process. A reduction in the process time was obtained by introducing $DIO_3$ cleaning with a dewaxing process.