• Title/Summary/Keyword: water quality environment standard

Search Result 333, Processing Time 0.034 seconds

Development of Biological Criteria for Water Quality Assessment using Benthic Diatoms (부착돌말류를 이용한 생물학적 수질평가지표 개발)

  • Noh, Seongyou;Byeon, Myeongseop;Kim, Miah;Lee, Jaekwan
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.879-885
    • /
    • 2009
  • The present study was carried out to develop biological criteria for water quality assessment using benthic diatoms. Selecting of the indicator diatoms, three parameters were considered: broad distribution (180 taxa occurred over 3% at upper level), species abundance (158 taxa occurred over $1.5{\times}10^5cells/cm^2$), and sensitivity (184 taxa occurred more than once as 1st and 2nd dominant species). Overall, total 208 taxa were selected, including 38 varieties, 170 species, 34 genera, 9 families, 3 orders, and 1 phylum. The most dominant taxonomic group (family) was Naviculaceae (52%), followed by Diatomaceae (15%), Nitzschiaceae (12%) and Achnantaceae (11%). COD and TP were proposed as new water quality standards (draft) to improve the existing BOD standard and to manage and control efficiently non-biodegradable organic pollutants. With this regard, we used TP standard (draft) in developing biological water quality criteria for diatoms. TP standards (draft) proposed as Ia = 0.02 mg/L or less, Ib = 0.05 mg/L or less, II = 0.1 mg/L or less, III = 0.2 mg/L or less, IV = 0.4 mg/L or less, V = 0.6 mg/L or less and VI = above 0.6 mg/L. Biological assessment system (4 class system) was developed and proposed for diatom using modified Tropic Diatom Index (TDI). Biological assessment of TDI appear B grade (Good).

Characteristics and Management Plan of Water Quality at the Water Pollution Deterioration Area of the Upper Stream of Gapcheon (갑천 상류부의 수질오염 우려구간 수질특성 및 수질관리방안)

  • Jang, Yuho;Son, Bongho;Chu, Shaoxiong;Lim, Bongsu
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.5
    • /
    • pp.399-408
    • /
    • 2019
  • The average annual water quality at Yongchon Bridge, Bonggok 2 Bridge, and Gasuwon Bridge in upstream of Gapcheon in 2018 was Ib grade (good) in organic matters, including BOD and TOC compared to the local environmental standard in Daejeon. However, their monthly changes for TOC partially exceeded the standard during the busy farming season at Bonggok 2 Bridge and Gasuwon Bridge. Although the annual average TP was within the standard, the monthly change at Bonggok 2 Bridge partially exceeded the standard. For Dugyecheon, the annual average water quality in 2018 at Umyeon-dong Bridge and Wonjeong Bridge, which are downstream of the Gyeryong public sewage treatment plant, exceeded the local environmental standard in BOD. COD was exceeded, and TP was within the standard. It seemed that the causes of deteriorated water quality downstream of Dugyecheon were discharges of agricultural water from agricultural land and effluent from the Gyeryong public sewage treatment plant. Assuming the pollution load of 100% based at the Mulangil point of the mainstream of Gapcheon, the ratio of BOD load and TOC load were as high as 58% and 47%, respectively. At the basin of Bonggok 2 Bridge and Mulangil, the loads downstream of Dugyecheon including the Gyeryong public sewage treatment plant were as high as 43% for TN and 56% for TP, respectively, indicating that Dugyecheon had a major impact on the water quality at the mainstream of Gapcheon.

Analysis of Water Quality caused by Improvement of Sewage Treatment Plant in Masan Bay (하수처리장 개선이 마산만 수질에 미치는 영향분석)

  • Oh Hyun-Taik;Goo Jun-Ho;Park Sung-Eun;Choi Yun-Sun;Jung Rae-Hong;Choi Woo-Jeung;Lee Won-Chan;Park Jong-Soo
    • Journal of Environmental Science International
    • /
    • v.14 no.8
    • /
    • pp.777-783
    • /
    • 2005
  • For the sustainable management of marine ecosystem in Masan Bay, we have to assess the carrying capacity and standard of target water quality. In this research, we assume that all pollutants loads are treated in Dukdong sewage treatment plant, then we simulate the physical-biological model for prediction water quality for the achievement of standard water quality. In 2001 year, for the achievement of COD 2.5 mg/L, we need to reduce COD $90\%$, nitrogen $30\%$, phosphate $90\%$ than that of the present value, According to these results, the water quality of sewage treatment plant is required to treat COD 13.5 mg/L, nitrogen 33.3 mg/L, phosphate 6,0 mg/L. If the sewage treatment plant will be expanded much larger in 2011, it will need to be treated in COD 6.6 mg/L, nitrogen 2.5 mg/L, phosphate 5 mg/L for the achievement of water quality standard in COD 2.5 mg/L.

A Study on the Water Quality Patterns of Unit Watersheds for the Management of TMDLs - in Nakdong River Basin - (수질오염총량관리 단위유역 수질변화 유형분석 - 낙동강수계를 대상으로 -)

  • Park, Jun Dae;Kim, Jin Lee;Rhew, Doug Hee;Jung, Dong Il
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.2
    • /
    • pp.279-288
    • /
    • 2010
  • The water quality variations or changes are closely relevant to the characteristics of unit watersheds and have an effect on the attainment of their water quality goal. This study was conducted to analyze the water quality distribution and its change patterns of unit watersheds in Nakdong river basin. It revealed that 25 unit watersheds out of 41 showed the normality in water quality. Most of unit watersheds had a considerable variation in water quality, especially in the season of spring and summer but a little in terms of flow rate. Annual relative differences in water quality ranged from 13.0 to 26.6% with the maximum of 75%. 28 unit watersheds (62%) had the tendency to decrease in water quality as the flow rate increased while 13 (38%) to increase. The extension of standard flow led to considerable differences in water quality depending on its ranges, which meant uncertainties might be included in the process of TMDL development. It is suggested that annual average flow rate should be chosen as a standard flow in the area where the water quality change has little relation to the flow rate.

The statistical evaluation on Quality of spring water using standard plate count in Seoul

  • Hwang, Young-Sook;Kim, Mi-Sun;Kim, Kyung-Sig;Choi, Byung-Hyun;Seo, Seong-Hoon
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.167.2-168
    • /
    • 2003
  • This study was performed to evaluate Quality of spring water in seoul. After the revision the guideline of water Quality control on July 2002, the ratio of non-passed samples of spring water increased evidently(2001, 24.5%$\rightarrow$2002, 37.5%). So Citizens of Seoul have been worried about what makes the difference between two years. To find out the major reason of that rapid increasement, the experimental results of standard plate count and psychrotrophilic bacteria in seoul were used. (omitted)

  • PDF

Framework for Deriving Water Quality Criteria of Toxic Substances (수질유해물질에 대한 수질환경기준 설정체계)

  • Chung, Yun-Chul;Ko, Dae-Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.305-313
    • /
    • 2005
  • In these days, water environment is getting threatened by a variety of toxic pollutants discharged from industries. However, environmental standards and regulations in Korea may be in straitened circumstances to protect the water environment from it. Therefore, the purpose of this review is to compare the management state of the toxic substances in water environment and to present the framework for deriving water quality criteria in USA and Japan. To conserve the water environment from the toxic pollutants more efficiently, the following considerations could be suggested in standards and regulation in Korea. Firstly, there should be consistency of regulated pollutants in drinking water quality standard, water quality standards and permissible wastewater discharge standards. Secondly, in case of deriving the water quality standards, it is required to consider the conservation of the aquatic ecosystem as well as the protection of human health. Finally, it is indispensable to make risk-based approach in management of toxic pollutants in water environment.

A Study on the Improvement Scheme of the Total Water Pollution Load Management Plan (수질오염총량관리 계획수립의 개선방안에 관한 연구)

  • Kim, Young-Il;Yi, Sang-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.977-981
    • /
    • 2006
  • In order to improve water quality in drinking water sources, Ministry of Environment (MOE) was implemented total water pollution load management (TWPLM) in all the major river basins. From the experience of the application of TWPLM, we could find some problems relating the target watershed, standard operating procedure (SOP) of establishment and implementation plan, water quality and flow rate, design flow, water quality model, margin of safety (MOS), and estimation of wasteload were found. The authors were reviewed ongoing TWPLM and presented the improvement schemes for a successful TWPLM. For the application of these suggestions, further detailed studies should be done to implement TWPLM in the future.

Evaluation of Impaired Waterbody and Multivariate Analysis Using Time Series Load Curve -in Jiseok Stream Watershed- (시계열 부하 곡선을 이용한 수체손상 평가 및 다변량 분석 -지석천 유역을 대상으로-)

  • Park, Jinhwan;Kang, Taewoo;Han, Sungwook;Baek, Seunggwon;Kang, Taegu;Yoo, Jechul;Kim, Youngsuk
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.650-660
    • /
    • 2017
  • In this study, pollutant emission characteristics by water damage period analyzed 11 items (water temperature, pH, DO, EC, BOD, COD, TOC, SS, T-N, T-P and flow) with load duration curve, time series load curve and factor analysis for three years (2014-2016). Load duration curve is applied to judge the level of impaired waterbody and estimate impaired level by pollutants such as BOD and T-P in this study depending on variation of stream flow. Water quality standard exceeded the flow of mid-range and low-range by flow condition evaluation using load duration curve. This watershed was influenced by point source more than non-point source. Cumulative excess rate of BOD and T-P kept water quality standard for all seasons (spring, summer, autumn and winter) except BOD 59% in spring. Water quality changes were influenced by pollutants of basic environmental treatment facilities and agricultural areas during spring and summer. Results of factor analysis were classified commonly first factor (BOD, COD, and TOC) and second factor (flow, water temperature and SS). Therefore, effects of artificial pollutants and maintenance water must be controlled seasonally and reduced relative to water damage caused by point pollution sources with effluent standard strengthened in the target watershed.

농촌지역 간이상수도 수질에 대한 수리지화학적 특성: 충남 금산군 일대

  • 이진수;고경석;김용재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.369-372
    • /
    • 2004
  • This study presents the hydrogeochmical investigation to know the effect of geology and sources for water quality in small potable water supply system at rural area. The results of water quality in Geumsan area showed the 3.2% of water samples exceeded the limit of drinking water standard by bacteria. The hydrochemical investigation results indicated the high EC, Ca and HCO$_3$ in surface water and metasedimentary rocks and this is caused by the dissolution of calc-slicate minerals of metasedimentary rocks.

  • PDF

Evaluation of Whole Effluent Toxicity (WET) Proficiency Testing for Water Quality Measurement Agencies in Korea (국내 수질측정대행업에 대한 생태독성 숙련도시험 평가)

  • Park, Woo Sang;Kim, Sang Hun
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.568-573
    • /
    • 2013
  • In this study, we conducted whole effluent toxicity (WET) proficiency testing based on the results which $EC_{50}$ value of 3 types (A, B, C) unknown samples calculated from 32 water quality measurement agencies in Korea. WET proficiency testing was expected to their improve of analysis skill and ensure reliability of analysis results. Ultimately, it is intended to promote the reliable enforcement of WET. WET proficiency testing was evaluated using the z-score, robust z-score and the results showed that 30 participating agencies were "compliance". In addition, $EC_{50}$ values of "unknown sample A" were the normal distribution. Therefore, "unknown sample A" was considered as the most suitable standard toxicity substance.