• Title/Summary/Keyword: water quality criteria

Search Result 425, Processing Time 0.032 seconds

Characteristics of Washed-off Pollutants and Dynamic EMCs in a Parking Lot and a Bridge during Storms (주차장 및 교량지역의 강우유출수내 비점오염물질의 특성 비교 및 동적 EMCs)

  • Kim, Lee-Hyung;Lee, Seonha
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.248-255
    • /
    • 2005
  • Since the water quality of drinking water sources has been recognized as a big issue, the ministry of Environment in Korea is designing the total maximum daily load (TMDL) program for 4 major large rivers. The TMDL program can be successfully performed as controling the nonpoint pollutants from watershed area near the river. Of the various landuses in nonpoint pollution, parking lots and bridges are stormwater intensive landuses because of high imperviousness and high pollutant mass emissions from vehicular activities. Vehicle emissions from those areas include different pollutants such as heavy metals, oil and grease and particulates from sources such as fuels, brake pad and tire wear, etc. Especially the pollutant washed-off from the landuses are directly affecting to the river water quality. Therefore this research was conducted to understand the magnitude and nature of the stormwater emissions with the goal of quantifying stormwater pollutant concentrations and mass emission rates of pollutants from parking lot and bridges in Korea. In Kongju city areas, two monitoring sites were equipped with an automatic rainfall gages and an automatic flow meter for accumulating the useful data such as rainfall, water quality and runoff flow. This manuscripts will show the concentration changes during storm duration and EMCs to characterize the concentration profiles in different land uses. Also the first flush criteria will be suggested using dynamic EMCs. The definition of dynamic EMC is a new approach explaining the relationship of EMC and first flush effect.

Effectivenss of Water based Exercise Training in COPD Patients: A Systematic Review and Meta-analysis (만성폐쇄성폐질환자의 수중운동중재 효과: 체계적 문헌고찰 및 메타분석)

  • An, Min-Hee;Kim, Yun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.7
    • /
    • pp.93-104
    • /
    • 2021
  • This study has been conducted by a systematic review of literature and a meta-analysis in order to identify the effect of water based exercise training for COPD(Chronic obstructive pulmonary disease). Two researchers selected relevant literature, and extracted the date and assessed the quality of literature. A total of 5 studies met the inclusion criteria, and the outcome of methodological quality of the literature was not positive. According to the result of meta-analysis of water based exercise and usual care, it was considerably effective in 6 MWT and quality of life. This study introduces various types of water based exercise for COPD patients, which is considered useful for application of the program. However, it experiences difficulty to generalize due to lack of the number of literature in relation to the water based excercise.

Determination of First Flush Criteria in Highway Stormwater Runoff using Dynamic EMCs (동적 EMC를 이용한 고속도로 초기우수 처리 기준 산정)

  • Kim, Lee-Hyung;Lee, Eun-Ju;Ko, Seok-Oh;Kim, Sung-Gil;Lee, Byung-Sik;Lee, Joo-Kwang;Kang, Hee-Man
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.294-299
    • /
    • 2006
  • The Ministry of Environment in Korea has introduced Total Pollution Load Management System (TPLMS) in major 4 large rivers to protect the water quality from possible pollutants. In order to successfully achieve the TPLMS, the nonpoint source should be controled by applying the best management practices in highly polluted areas. Of the various nonpoint sources, the highways are stormwater intensive landuses because of its high imperviousness and high pollutant mass emissions. The EMC (Event Mean Concentration) is an important parameter to correctly determine the pollutant mass loadings from nonpoint sources. However, it has wide ranges because of various reasons such as first flush phenomenon, rainfall and watershed characteristics. Even though the EMC is closely related to the first flush phenomenon, the relationship have not proven until present. Therefore, in this paper, the dynamic EMC method will be introduced to clearly make the relationship between EMC and first flush phenomenon. Also by applying the dynamic EMC method to monitored data, we found that the highly concentrated stormwater runoff was washed off within 20~50 minutes storm duration. The first flush criteria for economical treatment was also determined to 5~10 mm (mean=7.4 mm) as a cumulative rainfall.

An Analysis of Environmental Water Release Patterns Considering Operation Rules in Enlarged Agricultural Reservoirs (둑높이기 농업용저수지의 운영기준에 따른 환경용수 방류패턴 분석)

  • Lee, Sang-Hyun;Yoo, Seung-Hwan;Park, Na-Young;Choi, Jin-Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.3
    • /
    • pp.51-62
    • /
    • 2013
  • The importance of environmental water has been risen in terms of river ecosystem soundness with preventing stream flow depletion in rural area, while enlarging agricultural reservoir project is conducted under the 4 main river restoration project for supplying more water to 4 main rivers. The aim of this study was to estimate the amount of environmental water release and analyze the release pattern during non-irrigation season in enlarged agricultural reservoirs. The 4 reservoirs (Dansan, Samga, Geumbong, Changpyeong) located on the upper region of Nakdong river were simulated applying the operation rule which was determined by release criteria curves. The simulated results indicated that the more environmental water could be released than the spillway release and continuous release was achieved with smaller range of fluctuation. In case of Changpyeong reservoir, average 506.0 thousand $m^3$ environmental water could be released on Feb., and it was about twice as much as the spillway release before the enlargement, and also, the 18 thousand $m^3$/day environmental water could be supplied to a stream consistently after enlargement. From the results, it was expected that the additional environmental water release will improve stream water flow during dry season in terms of quantity and quality of water.

The Various Factors which Should Be Considered in Classifying Toxic Substances in Water and Deriving Their Effluent Limits: Focusing on the Reduction of Risk (수질유해물질의 지정 및 배출허용기준 설정 시 고려해야 하는 복합적 요인에 대한 고찰: 위해성 저감을 중심으로)

  • Bae, Hyokwan;Chung, Yun-Chul;Yang, Hyungjae;Kim, Jaehoon;Lee, Hyun Dong;Jung, Jin-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.766-775
    • /
    • 2007
  • The use of toxic chemicals was extended as the industry in Korea has grown dramatically during the last three decades. However, list of toxic substances and limit concentrations in the water environment are not consistent within management of ambient water, drinking water and industrial effluent. This article suggests the systematic framework to classify toxic substances in the water environment and deriving their effluent limits. The most important factor for decision-making to classify toxic substances is whether their concentrations in the water environment are higher than the reference concentrations, estimated by considering human health risk and ecological risk. Using a risk-based reference concentration, the ambient water quality criterion, it is possible to derive the regulatory limit concentrations of toxic substances in drinking water and in industrial effluent. The goal concentrations in the effluent, which guarantee the human and ecological safety, should be determined with scientific investigation, balancing environmental benefit and economical effect, considering availability of treatment technology and identifying characteristics of wastewater from different industries.

Simultaneous determination of 37 volatile organic compounds at ng/L concentration level in surface water by HS-SPME-GC/MS (HS-SPME-GC/MS에 의한 지표수에서 ng/L 농도 수준의 37개 휘발성유기화합물의 동시 분석)

  • Kim, Tae-Seung;Hong, Suk-Young;Kim, Jong-Eun;Lim, Hyun-Hee;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.39-49
    • /
    • 2012
  • A method to detect 37 volatile organic compounds (VOCs) in surface water was described based on headspace solid-phase micro extraction and gas chromatography-mass spectrometry. VOCs in water were vaporized for 30 min at 40 $^{\circ}C$ in a headspace vial and adsorbed on 85 ${\mu}m$ carboxen-polydimethylsiloxane. Under the established condition, the lowest quantification limit was 4.1-96 ng/L by using 4.0 mL water sample, and the relative standard deviation was less than 15% at concentrations of 0.05 and 0.50 ${\mu}g/L$. The detection limits meet lower concentration than 1/10 of the water quality criteria for VOCs established by the US EPA or Germany. The LOQ is a sensitivity which the monitoring for the establishing water quality criteria requires. When the proposed method was used to analyze the target compounds in sixteen surface water samples and total 16 VOCs were detected in surface water samples collected from Gum-River. Maximum concentrations of VOCs detected were not exceeded the EPA or Germany guidelines in any of the samples.

Temporal and Spatial Fluctuations of Coastal Water Quality and Effect of Small Tide Embankment in the Muan Peninsula of Korea (무안반도 연안수질의 시ㆍ공간적 변동과 소규모 방조제의 영향)

  • Lee Dae-In;Cho Hyeon-Seo;Lee Gyu-Hyung;Lee Moon-Ok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.6 no.4
    • /
    • pp.24-36
    • /
    • 2003
  • In this study, we estimated the seasonal fluctuations of water quality and effect of small tide embankment in coastal water around the Muan Peninsula, which is located in the northern part of Mokpo city, and layer farming ground is spread around there. Some physical and chemical factors were analyzed to characterize water quality from Jan. to Oct. in 1994. The results were as follows: Dissolved oxygen was slightly under saturation in the almost areas of July, and in some bottom layer at ebb tide of October. Distribution of COD showed high values that over 2㎎/L in October and flood tide of April by the discharge of freshwater and resuspension of benthic sediment, which exceeded water quality criteria II. Maximum values of dissolved inorganic nitrogen ware appeared in surface layer during the flood tide of October, while minimum of that showed in surface layer in April. Concentration of dissolved inorganic phosphorus was higher at July than the others, which ranged from 0.24 to 2.08㎍-at/L. Mostly mean values of N/P ratio were lower than 16, it mean that nitrogen is more limiting nutrient than phosphorus for the growth of phytoplankton. The values of eutrophication index were in the range of 0.07~0.81. However, very high values due to increase of COD were estimated near the tide embankment and southern part in relation to tidal current in October. Water quality around tide embankment was suddenly changed worse within a short period after opening the water gate during the rainfall.

  • PDF

Study on Establishment of the Industrial Wastewater Effluent Limitations Based on Best Practicable Control Technology Currently Available - Case Study for the Pulp, Paper and Paper Board Manufacturing (실용 가능한 최적처리기술에 근거한 산업폐수 배출허용기준 설정 연구 - 펄프.종이 및 종이제품 제조시설 적용 사례)

  • Kim, Jaehoon;Shin, Jinsoo;Lee, Chulgu;Lee, Jungyoung;Lee, Youngsun;Yu, Soonju
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.608-614
    • /
    • 2012
  • The effluent limitation of industrial wastewater is based on uniform regulatory criteria for effluent discharge facilities of all in Korea. But, an individual effluent limitation on each effluent discharge facility is widely applicable for regulation of industrial wastewater in US.EPA. To decide an individual effluent limitation, TBEL (Technology-based effluent limitation) and WQBEL (Water quality-based effluent limitation) are used. TBEL is based on the capability of a treatment technology to reduce the pollutants. WQBEL is based on ambient water quality standards. In this study, TBEL were derived for the pulp, paper and paper board manufacturing based on best practicable control technology currently available. It was suggested that effluent limitations were $BOD_5$ 4.7 mg/L, $COD_{Mn}$ 44.3 mg/L, SS 13.2 mg/L, TN 1.4 mg/L, TP 0.15 mg/L and best practicable control technology currently available (BPT) was neutralization, activated sludge treatment and coagulation and sedimentation for the pulp, paper and paper board manufacturing.

A Survey on the Envlronmcntal Sanitary Status of Water Supply System in Rural Area (농촌급수시설에 관한 환경위생확적 조사연구)

  • 박국환;김성자
    • Journal of Environmental Health Sciences
    • /
    • v.5 no.1
    • /
    • pp.76-85
    • /
    • 1978
  • This survey was undertaken for the period seven month beginning January 15, 1977 and ending July 31, 1977 to detect the general sanitary status of the villages and the villagers and, at the same time, analyse quality of water sources with emphasis on a total of 1,256 households dividing into three different groups: such as, 280 households were selected as random samples from the area of the sophisticated piped water supply system, 122 households from the area of the simplified water supply system and finally 854 households from the area of nonpi-ped water supply system. The following results were concluded after quality of water sources had been analysed and conditions of the environmental sanitation had been reviewed: 1. 11.2% of the respondents from the area of the sophisticated piped water supply system responded that quantity of drinking water lacked to meet their demand while 30.6% of the villagers from the area of nonpi-ped water supply system responded quantity of drinking water didn't meet their demand. 2. 30.8% of the.respondents from the area of the sophisticated water supply system responded that contaminating source located within 15 meters from the water source while 54.4% of the respondents from the non-piped water supply system claimed the same. 3. It was found that water from all sampling areas were positive in coliform group with exception of Moonsan which is one of the sophisticated piped water supply system groups and the number of general bacteria exceeded the government standard criteria of water quality in the area of the nonpi-ped water supply system. 4. In relation with time requirement to draw water in the area of non-piped water supply system, 76 respondents claimed it requires less than 15 minutes to draw water, 15.0% claimed 15 to 30 minutes and 9.0% claimed more than 30 minutes. 5. In relation with knowledge on sanitation of drinking water, 30.8% of respondents from the area of the sophisticated piped water supply system and 41.8% of respondents from the area of nonpiped water supply system denied possible existence of germ in drinking water they drink, while 17.4% of the respondents from the area of the sophisticated water supply system and 50.2% of non-peped water supply system thought it safe to drink water without any treatment. 6. 60.0% of the respondents from the area of non-piped water supply system and many of them believed that their health status will be improved by installation of a sophisticated water supply system in their area. 7. The respondents from the areas of piped water supply sytem expressed greater concern over drinking water sanitation than those from the areas of non-piped water supply system and sanitary conditions were found the same. It was, therefore, proved that knowledge of environmnntal sanitation contributed a great deal to improve sanitary conditions of the villages and villagers and at the same time health education, especially environmental sanitation, will be played a important role to improve their sanitary conditions.

  • PDF

Comparative Study of Groundwater Threshold Values in European Commission and Member States for Improving Management of Groundwater Quality in Korea (국내 지하수 수질관리체계 개선을 위한 유럽 지하수 문턱값 비교)

  • Nam, Sun-Hwa;Lee, Woo-Mi;Jeong, Seung-Woo;Kim, Hye-Jin;Kim, Huyn-Koo;Kim, Tae-Seung;An, Youn-Joo
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.3
    • /
    • pp.23-32
    • /
    • 2013
  • Korean groundwater quality standards were established in 1994, and revised in 2003 and 2010. The substances for which standards have been developed are classified into two groups, general pollutants, 4, and specific pollutants, 15. The standards have been applied to household water use, agriculture, aquaculture, and industrial use. However, there is no systematic methodology for either selecting candidate substances or establishing groundwater standards. We investigated various derivation methodologies for groundwater standards used by the European Commission and 27 member states and compared their methods for determining threshold values. The European Commission presented to their member states groundwater standards for two substances and a list of required substances for derivation of threshold values along with the member states. Interestingly, they first considered national background levels and then considered other criteria for water protection, such as drinking water standards, environmental quality standards, and irrigation standards. We suggest that Korean background levels in groundwater should be included in the methodology for establishing groundwater quality standards. These results may be useful in developing a systematic methodology for establishing Korean groundwater quality standards.