• Title/Summary/Keyword: water primer

Search Result 163, Processing Time 0.034 seconds

A COMPARISON OF RELEASE RATE AND CUMULATIVE RELEASE OF TEGDMA WITH OR WITHOUT THE APPLICATION OF BONDING RESIN (접착레진 적용 유무에 따른 TEGDMA의 방출속도 및 방출량 비교)

  • Shin, Hee-Jung;Jeon, Seong-Min
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.701-709
    • /
    • 1998
  • Many dental composites are Bis-GMA based resin which diluted with the more fluid monomer triethylenglycol dimethacrylate(TEGDMA). TEGDMA is often present in exess so that some quantity remains unreacted following photo-initiated polymerization. TEGDMA is a component of some resin composites which contributes to their cytotoxicity. The presence of dentin between resin composite and pulp space reduce the cytotoxicity in vitro. The root system from extrcted human third molar was removed and then a circular occlusal cavity 4mm in diameter was prepared, leaving a remaining dentinal thickness to the roof of the pulpal chamber within the range 1.0-1.5mm. Dentine was treated with 37% phosphoric acid prior to Z 100 placement without using bonding resin(group 1). In group 2, SMP(Scotchbond Multi Purpose) primer, bonding resin prior to Z 100 placement were applied sequently. In group 3, moulds with internal dimensions 4mm diameter by 2mm depth were used to contain the composite alone with an equvalent mass on tooth model, and then they were immersed directly into water. The purpose of this study is to evaluate the release rate and quantity of TEGDMA with or without the application of bonding resin. Both release rate and total cumulative amount of TEGDMA for the three groups were determined using reversed-phase HPLC at times up to 10 days. The results were as follows: 1. All experimental groups showed the highest rate of release was in the first sample period(0-4.32 min) and the rate of release declined exponentially thereafter. 2. The maximum release rate and total cumulative account of TEGDMA in the tooth model of group 1 and group 2 with the use of SMP bonding resin were reduced however ther were no significant differences between these groups(P>0.05). 3. In the first sample period(0-4.32 min), the rate of release of TEGDMA from composite resin in group 3 immersed directly into water was significantly higher than that in group 1 and group 2 of tooth model(P<0.05). Conclusively, TEGDMA diffusion from Z 100 resin was not effectively prevented by the presence of dentin in spite of using the SMP bonding resin.

  • PDF

Spatial and seasonal distributions of the phototrophic dinoflagellate Biecheleriopsis adriatica (Suessiaceae) in Korea: quantification using qPCR

  • Kang, Hee Chang;Jeong, Hae Jin;Ok, Jin Hee;You, Ji Hyun;Jang, Se Hyeon;Lee, Sung Yeon;Lee, Kyung Ha;Park, Jae Yeon;Rho, Jung-Rae
    • ALGAE
    • /
    • v.34 no.2
    • /
    • pp.111-126
    • /
    • 2019
  • The phototrophic dinoflagellate Biecheleriopsis adriatica is a small suessioid species characterized by a fragile thin wall. Although the morphology of this dinoflagellate is well established, there is currently little information available on its distribution and the environmental factors that influence this distribution. Thus, to investigate the spatial and seasonal distributions of the vegetative cells of B. adriatica in Korean waters, surface water samples were collected on a seasonal basis from 28 stations in the East, West, and South Sea of Korea and Jeju Island from April 2015 to October 2018, and abundances of the vegetative cells of B. adriatica were quantified using quantitative real-time polymerase chain reactions, for which we developed the species-specific primer and probe set. Simultaneously, major environmental parameters, including temperature, salinity, nutrient concentrations, and dissolved oxygen concentrations were measured. The vegetative cells of B. adriatica were detected at 20 of the 28 sampling stations: 19 stations in summer and 6 in autumn, although from no stations in either spring or winter. The ranges of water temperature and salinity at sites where this species was detected were $17.7-26.4^{\circ}C$ and 9.9-34.3, respectively, whereas those of nitrate and phosphate concentrations were not detectable-96.2 and $0.18-2.66{\mu}M$, respectively. Thus, the sites at which this species is found are characterized by a narrow range of temperature, but wide ranges of salinity and concentrations of nitrate and phosphate. The highest abundance of the vegetative cells of B. adriatica was $41.7cells\;mL^{-1}$, which was recorded in Jinhae Bay in July 2018. In Jinhae Bay, the abundance of vegetative cells was significantly positively correlated with the concentration of nitrate, but was negatively correlated with salinity. On the basis of these findings, it appears that the abundance of B. adriatica vegetative cells shows strong seasonality, and in Jinhae Bay, could be affected by the concentrations of nitrate.

Comparison of the spatial-temporal distributions of the heterotrophic dinoflagellates Gyrodinium dominans, G. jinhaense, and G. moestrupii in Korean coastal waters

  • Lee, Sung Yeon;Jeong, Hae Jin;Kang, Hee Chang;Ok, Jin Hee;You, Ji Hyun;Park, Sang Ah;Eom, Se Hee
    • ALGAE
    • /
    • v.36 no.1
    • /
    • pp.37-50
    • /
    • 2021
  • Heterotrophic dinoflagellates Gyrodinium spp. are one of the major grazers of phytoplankton in many coastal waters. Gyrodinium dominans, G. jinhaense, and G. moestrupii have similar morphologies but different edible prey species. To explore the variations in the ecological niches of these three species, we investigated their spatial-temporal distributions in Korean waters. Because of the high similarity in morphology among these three Gyrodinium species, we used real-time polymerase chain reactions to quantify their abundance in water samples that were seasonally collected from 28 stations along the Korean Peninsula from April 2015 to October 2018. Cells of G. dominans were found at all sampling stations, G. jinhaense at 26 stations, and G. moestrupii at 22 stations, indicating that all three species were widely distributed in Korea. Furthermore, all three species displayed strong seasonal distributions. The largest numbers of the stations where G. dominans and G. jinhaense cells were present were found during the summer (26 and 23 stations, respectively), but that for G. moestrupii was found in the autumn (15 stations). The abundance of G. dominans was positively correlated with that of G. jinhaense, but not with that of G. moestrupii. The highest abundances of G. dominans (202.5 cells mL-1) and G. jinhaense (20.2 cells mL-1) were much greater than that of G. moestrupii (1.2 cells mL-1). The highest abundances of G. dominans and G. jinhaense were found in July, whereas that of G. moestrupii was found in March. The abundances of G. dominans and G. jinhaense, but not G. moestrupii, were positively correlated with water temperature. Therefore, the spatial-temporal distributions of G. dominans and G. jinhaense were closer than those of G. moestrupii and G. dominans or G. jinhaense. This differs from results based on the relative differences in ribosomal DNA sequences and the types of edible prey reported in the literature. Thus, the variations in spatial-temporal distributions and prey species of these three Gyrodinium species suggest that they may have different ecological niches in Korean coastal waters.

COMPARISON OF MICROLEAKAGE WITH THREE DIFFERENT ADHESIVE SYSTEMS (수 종의 복합레진 접착 시스템에서의 미세 누출의 비교)

  • Seok, Choong-Ki;Nam, Dong-Woo;Nam, Soon-Hyeun;Kim, Young-Jin;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.636-644
    • /
    • 2004
  • Recently, self-etching adhesive system have been developed and bonding procedures simplified into one or two steps, which are simultaneously applied to both enamel and dentin. These systems are easy to use and have the potential for good clinical success. The purpose of this study is to evaluate in vitro the microleakage on the cementum/dentin and enamel walls in composite resin restoration of Class V cavities, regarding the use of different adhesive systems. 30 human premolars were divided into 3 groups. A standardized Class V preparation was prepared on the buccal and lingual surface of each premolar. The preparation were made parallel to the cementoenamel junctions, with the gingival half of the preparation extending 1mm apical to the cementoenamel junction. After adhesive system was applied to teeth as manufacture's recommendation, hybrid resin composite was filled in bulk into the preparation and light polymerized according to manufacturer's recommendations. Specimen were stored in distilled water at $37^{\circ}C$ for 5 days and thermocycled 1000 times ($5^{\circ}C{\pm}2^{\circ}C\;and\;55^{\circ}C{\pm}2^{\circ}C)$, then immersed in a 2% methylene blue solution for 12 hours. After sectioning mesio distally through the restorations, the degree of dye penetration was scored under a stereomicroscope at ${\times}\;25$ magnification. The data were analyzed statistically using t-test and one-way ANOVA. The results were as follows: ${\cdot}$ There is no adhesive system which can prevent microleakage perfectly. ${\cdot}$ There is significant difference in microleakage between enamel margin and dentin margin (p<0.0001). ${\cdot}$ In enamel margin, self-etching primer systems did not show any significant difference comparing total-etching system. In denin margin, self-etching primer systems did not show any significant difference comparing one-bottle adhesive system used in combination with total-etching.

  • PDF

MARGINAL MICROLEAKAGE AND SHEAR BOND STRENGTH OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF ARTIFICIAL SALIVA-CONTAMINATED SURFACE AFTER PRIMING (접착강화제 도포후 인공타액에 오염된 표면의 처리방법에 따른 복합레진의 번연누출과 전단결합강도)

  • Cho, Young-Gon;Ko, Kee-Jong;Lee, Suk-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.46-55
    • /
    • 2000
  • During bonding procedure of composite resin, the prepared cavity can be contaminated by saliva. In this study, marginal microleakage and shear bond strength of a composite resin to primed enamel and dentin treated with artificial saliva(Taliva$^{(R)}$) were evaluated. For the marginal microleakage test, Class V cavities were prepared in the buccal surfaces of fifty molars. The samples were randomly assigned into 5 groups with 10 samples in each group. Control group was applied with a bonding system (Scotchbond$^{TM}$ Multi-Purpose plus) according to manufacture's directions without saliva contamination. Experimental groups were divided into 4 groups and contaminated with artificial saliva for 30 seconds after priming: Experimental 1 group ; artificial saliva was dried with compressed air only, Experimental 2 group ; artificial saliva was rinsed and dried. Experimental 3 group ; cavities were etched with 35% phosphoric acid for 15 seconds after rinsing and drying artificial saliva. Experimental 4 group ; cavities were etched with 35% phosphoric acid for 15 seconds and primer was reapplied after rinsing and drying artificial saliva. All the cavities were applied a bonding agent and filled with a composite resin (Z-100$^{TM}$). Specimens were immersed in 0.5% basic fuschin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from one specimen. Degree of marginal leakage was scored under stereomicroscope and their scores were averaged from four sections. The data were analyzed by Kruscal-Wallis test and Fisher's LSD. For the shear bond strength test, the buccal or occlusal surfaces of one hundred molar teeth were ground to expose enamel(n=50) or dentin(n=50) using diamond wheel saw and its surface was smoothed with Lapping and Polishing Machine(South Bay Technology Co., U.S.A.). Samples were divided into 5 groups. Treatment of saliva-contaminated enamel and dentin surfaces was same as the marginal microleakage test and composite resin was bonded via a gelatin capsule. All specimens were stored in distilled water for 48 hours. The shear bond strengths were measured by universal testing machine (AGS-1000 4D, Shimaduzu Co., Japan) with a crosshead speed of 5 mm/minute. Failure mode of fracture sites was examined under stereomicroscope. The data were analyzed by ANOVA and Tukey's studentized range test. The results of this study were as follows : 1. Enamel marginal microleakage showed no significant difference among groups. 2. Dentinal marginal microleakages of control, experimental 2 and 4 groups were lower than those of experimental 1 and 3 groups (p<0.05). 3. The shear bond strength to enamel was the highest value in control group (20.03${\pm}$4.47MPa) and the lowest value in experimental 1 group (13.28${\pm}$6.52MPa). There were significant differences between experimental 1 group and other groups (p<0.05). 4. The shear bond strength to dentin was higher in control group (17.87${\pm}$4.02MPa) and experimental 4 group (16.38${\pm}$3.23MPa) than in other groups, its value was low in experimental 1 group (3.95${\pm}$2.51 MPa) and experimental 2 group (6.72${\pm}$2.26MPa)(p<0.05). 5. Failure mode of fractured site on the enamel showed mostly adhesive failures in experimental 1 and 3 groups. 6. Failure mode of fractured site on the dentin did not show adhesive failures in control group, but showed mostly adhesive failure in experimental groups. As a summary of above results, if the primed tooth surface was contaminated with artificial saliva, primer should be reapplied after re-etching it.

  • PDF

THE EFFECTS OF SURFACE CONTAMINATION BY HEMOSTATIC AGENTS ON THE SHEAR BOND STRENGTH OF COMPOMER (지혈제 오염이 콤포머의 전단결합강도에 미치는 영향)

  • Heo, Jeong-Moo;Kwak, Ju-Seog;Lee, Hwang;Lee, Su-Jong;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.150-157
    • /
    • 2002
  • One of the latest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not dry but left moist before application of the bonding primer Ideally the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically, contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during cavity preparation. The aim of this study was to evaluate the effect of contamination by hemostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were removed soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive papers on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows : Group 1: Dentin surface was not etched and not contaminated by hemostatic agents. Group 2: Dentin surface was not etched but was contaminated by Astringedent$^{\circledR}$(Ultradent product Inc., Utah, U.S.A.) Group 3: Dentin surface was not etched but was contaminated by Bosmin$^{\circledR}$(Jeil Pharm, Korea.). Group 4: Dentin surface was not etched but was contaminated by Epri-dent$^{\circledR}$(Epr Industries, NJ, U.S.A.). Group 5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6: Dentin sorface was etched and contaminated by Astringedent$^{\circledR}$. Group 7 : Dentin surface was etched and contaminated by Bosmin$^{\circledR}$. Group 8: Dentin surface was etched and contaminated by Epri-dent$^{\circledR}$. Group 9: Dentin surface was contaminated by Astringedent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 10: Dentin surface was contaminated by Bosmin$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 11 : Dentin surface was contaminated by Epri-dent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. After surface conditioning, F2000$^{\circledR}$ was applicated on the conditoned dentin surface The teeth were thermocycled in distilled water at 5$^{\circ}C$ and 55$^{\circ}C$ for 1,000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the knife-edge shearing rod of the Universal Testing Machine(Zwick Z020, Zwick Co., Germany) running at a cross head speed or 1.0 mm/min. Group 2 showed significant decrease in shear bond strength compared with group 1 and group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

Shear Bond Strength and Microleakage of a New Self-etch Sealant Containing S-PRG filler (S-PRG 필러를 포함하는 치면열구전색제의 전단결합강도 및 미세누출)

  • An, Jinseon;Lee, Juhyun;Seo, Hyunwoo;Park, Howon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.347-353
    • /
    • 2016
  • The purpose of this study was to evaluate shear bond strength and microleakage of a new self-etch fissure sealant containing S-PRG filler (BeautiSealant). Fourty-five premolars were randomly divided into three groups: SEPBS group (Self-etching primer + BeautiSealant), AEBS group (Phosphoric acid etching + BeautiSealant), AECP group (Phosphoric acid etching + $Clinpro^{TM}$ sealant). For the shear bond strength test, microcylinders of fissure sealant were bonded to prepared buccal surfaces of teeth and shear bond strengths were measured by a universal testing machine. For the microleakage test, sealants were applicated on each occlusal fissure of teeth. All teeth surface were coated with finger nail varnish, with the exception of a 1.0 mm window around the sealant margins. The teeth were immersed in 2% methylene blue solution for 24 hours and then rinsed in water. The teeth were then embedded in resin and cut buccolingually along the tooth axis and observed with a stereomicroscope to determine the degree of microleakage. SEPBS group demonstrated lower bond strength in comparison with that of AEBS and AECP groups (p < 0.05). However, no significant differences were observed between AEBS and AECP groups. There was no statistically significant difference in degree of microleakage among three groups.

Rapid and Sensitive Detection of Salmonella spp. by Using a Loop-Mediated Isothermal Amplification Assay in Duck Carcass Sample (오리 도체에서 등온유전자증폭기법을 이용한 Salmonella spp. 신속 고감도 검출 기법 연구)

  • Cho, Ae-Ri;Dong, Hee-Jin;Cho, Seongbeom
    • Food Science of Animal Resources
    • /
    • v.33 no.5
    • /
    • pp.655-663
    • /
    • 2013
  • In this study, a rapid and sensitive detection tool for screening Salmonella spp. by using a loop-mediated isothermal amplification (LAMP) assay targeting the genomic sequence of the invA gene was developed. The inclusivity and exclusivity were both at 100% in the analysis, and the limit of detection (LOD) in a pure S. Enteritidis culture suspended in saline was $3.2{\times}10^3$ CFU/mL at 18.17 min ($R^2$ = 0.9446). The LODs of the LAMP assay in buffered peptone water with Salmonella (BPW) and duck carcass swab sample enriched in BPW with Salmonella (BPWS) after 0 and 12 h incubation were $3.2{\times}10^3$ CFU/mL and $3.2{\times}10^0$ CFU/mL, respectively. Comparing the LODs in BPW with those in BPWS, the LAMP assay was less influenced by compounds of duck carcass swab sample than the PCR assay. Sensitivity and specificity of the LAMP assay in 50 duck carcass swab samples enriched in BPW for 6 h were 96% and 84%, respectively, indicating that the LAMP assay is a rapid, simple and sensitive assay, which can be utilized as a potential screening tool of Salmonella spp. in duck carcass sample.

Cultural Characteristics and Genetic Diversity of Rhizina undulata Isolates by Random Amplified Polymorphic DNA(RAPD) (리지나뿌리썩음병균 분리주들의 배양 특성 및 RAPD에 의한 유전적 다양성 분석)

  • Lee, Sang Yong;Lee, Sun Keun;Lee, Jong Kyu;Kim, Kyung Hee;Lee, Seung Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.4
    • /
    • pp.388-392
    • /
    • 2006
  • To investigate physiological characteristics and genetic diversity of Rhizina undulata isolates distributed in Korea, cultural characteristics and random amplified polymorphic DNA (RAPD) of 13 Rhizina undulata isolates from Pinus densiflora and P. thunbergi stands were analyzed. There were no correlations between the host species of R. undulata isolates and the mycelial growth of R. undulata isolates on culture media supplemented with water-soluble extract from the two different host species, i.e., Pinus densiflora and P. thunbergi. Genetic diversity of genomic DNA from 13 R. undulata isolates was analyzed by RAPD using 12 random primers. There was no differentiation in RAPD profiles among the isolates from Korea. But, there was some differentiation in RAPD profiles between Korean isolates and Japanese isolates, with 88% homology by phylogenetic tree analysis.

Groundwater Contamination of Noroviruses in Busan, Ulsan, and Gyeongsangnam-do, Korea (부산, 울산 및 경상남도 지역의 지하수 중 norovirus 오염실태 조사)

  • Park, Byung-Ju;Oh, Hae-Ri;Kang, Ho-Young;Jang, Kyung-Lib
    • Journal of Life Science
    • /
    • v.21 no.6
    • /
    • pp.819-828
    • /
    • 2011
  • To inspect norovirus contamination of groundwater in south eastern areas of Korea, a systematic survey of groundwater in Busan, Ulsan, and Gyeongsangnam-do was performed for two years from 2009 to 2010. For this purpose, we first optimized the nested reverse transcription-PCR condition by designing two sets of primers for the detection of norovirus genogroups, GI and GII. Of 145 samples, 21 (25.9%) and 15 (23.4%) were norovirus positive in the dry season (April to June) and wet season (July to August), respectively. The detection frequencies of norovirus in Busan, Ulsan, and Gyeongsangnam-do were 15%, 7%, and 32%, respectively, reflecting a geographical difference in their distribution. The GI and GII isolates were 5 and 31, respectively, indicating the prevalence of GII in the tested areas. According to phylogenetic analysis of their nucleotide sequences, all of the GI isolates were identified to genotype GI.5 whilst the GII isolates were divided into two genotypes, GII.3 and GII.4. Neither physical-chemical parameters such as pH, temperature, oxidation-reduction potential, and dissolved oxygen, nor microbial indicators of water quality such as total bacteria, total coliforms, and Escherichia coli were statistically correlated with contamination of norovirus in the groundwater. Interestingly, however, the presence of norovirus was closely correlated with low turbidity (<0.50 NTU). The present study suggests that periodical monitoring of norovirus in groundwater is necessary to prevent epidemic waterborne diseases and to secure better sanitary conditions for public health.