Development of a polystyrene phantom for quality assurance of a Gamma Knife®

  • Yona Choi;Kook Jin Chun;Jungbae Bahng;Sang Hyoun Choi;Gyu Seok Cho;Tae Hoon Kim;Hye Jeong Yang;Yeong Chan Seo;Hyun-Tai Chung
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2935-2940
    • /
    • 2023
  • A polystyrene phantom was developed following the guidance of the International Atomic Energy Association (IAEA) for gamma knife (GK) quality assurance. Its performance was assessed by measuring the absorbed dose rate to water and dose distributions. The phantom was made of polystyrene, which has an electron density (1.0156) similar to that of water. The phantom included one outer phantom and four inner phantoms. Two inner phantoms held PTW T31010 and Exradin A16 ion chambers. One inner phantom held a film in the XY plane of the Leksell coordinate system, and another inner phantom held a film in the YZ or ZX planes. The absorbed dose rate to water and beam profiles of the machine-specific reference (msr) field, namely, the 16 mm collimator field of a GK PerfexionTM or IconTM, were measured at seven GK sites. The measured results were compared to those of an IAEA-recommended solid water (SW) phantom. The radius of the polystyrene phantom was determined to be 7.88 cm by converting the electron density of the plastic, considering a water depth of 8 g/cm2. The absorbed dose rates to water measured in both phantoms differed from the treatment planning program by less than 1.1%. Before msr correction, the PTW T31010 dose rates (PTW Freiberg GmbH, New York, NY, USA) in the polystyrene phantom were 0.70 (0.29)% higher on average than those in the SW phantom. The Exradin A16 (Standard Imaging, Middleton, WI, USA) dose rates were 0.76 (0.32)% higher in the polystyrene phantom. After msr correction factors were applied, there were no statistically significant differences in the A16 dose rates measured in the two phantoms; however, the T31010 dose rates were 0.72 (0.29)% higher in the polystyrene phantom. When the full widths at half maximum and penumbras of the msr field were compared, no significant differences between the two phantoms were observed, except for the penumbra in the Y-axis. However, the difference in the penumbra was smaller than variations among different sites. A polystyrene phantom developed for gamma knife dosimetry showed dosimetric performance comparable to that of a commercial SW phantom. In addition to its cost effectiveness, the polystyrene phantom removes air space around the detector. Additional simulations of the msr correction factors of the polystyrene phantom should be performed.

6MV 광자선에서 측정조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교 (The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams)

  • 김회남
    • 대한방사선치료학회지
    • /
    • 제10권1호
    • /
    • pp.11-22
    • /
    • 1998
  • The absolute absorbed dose can be determined according to the measurement conditions ; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of $10{\times}10cm$ field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations on phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG2l and IAEA protocol. The differences between two protocols are within $1\%\;while\;the\;average\;value\;of\;IAEA\;protocol\;was\;0.5\%$ smaller than TG2l protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within $1\%,\;but\;individual\;discrepancies\;are\;in\;the\;range\;of\;-2.5\%\;to\;1.2\%$ depending upon the choice of measurement combination. The largest discrepancy of $-25\%$ was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coefficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, It shows that absorbed dose could be affected by phantom material other than water.

  • PDF

감마나이프 C모델에 대한 IAEA TRS-398 프로토콜의 적용 (Application of IAEA TRS-398 Protocol to Gamma Knife Model C)

  • 정현태
    • 한국의학물리학회지:의학물리
    • /
    • 제18권4호
    • /
    • pp.194-201
    • /
    • 2007
  • 감마나이프는 한 번에 수 Gy의 선량을 조사하는 일반 방사선 치료에 비하여 훨씬 많은 수십 Gy의 고선량을 한 번에 조사하기 때문에 조사되는 방사선량의 절대값 측정이 매우 중요하다. 그러나, 감마나이프의 물흡수선량 절대 측정값을 검증하는 연구는 많지 않다. 더욱이, 물팬텀 사용을 규정한 국제원자력기구(International Atomic Energy Agency: IAEA) TRS-398 프로토콜을 적용하여 물흡수선량을 측정한 연구는 보고되고 있지 않다. 본 연구에서는 IAEA TRS- 398 프로토콜을 이용하여 감마나이프 C모델의 물흡수선량을 측정하는 실험을 하였다. 본 실험에서는 IAEA TRS-398에 규정한 바를 최대한 따르면서 물팬텀을 제작하여 감마나이프 C모델의 물흡수선량을 측정하고, 감마나이프 제작사에서 제공하는 플라스틱 팬텀에서 측정한 값과 비교하였다. 이온함으로는 Capintec 사의 PR-05P mini-chamber 두 개를 사용하였고, 전리계로는 PTW사의 UNIDOS를 사용하였다. 측정 결과 물팬텀에서 측정한 감마나이프 모델C의 물흡수선량은 제작사의 플라스틱팬텀에서 측정한 값에 비하여 1.38% 크게 나타났다- 따라서, 현재 국내 감마나이프센터에서 사용하고 있는 제작사에서 제공하고 물흡수선량 측정 프로토콜에는 물팬텀 대신 플라스틱팬텀을 사용하는 데 따른 기온적인 문제점이 있는 것으로 판단된다. 결론적으로 IAEA TRS-398프로토콜을 직접적으로 감마나이프 물흡수선량 측정에 적용하는 것은 기준조건을 만족시킬 수 없기 때문에 불가능한 것으로 판단되며, 새로운 프로토콜을 작성하거나, 물팬텀과 기존의 플라스틱 팬텀으로 측정한 값 사이의 변환계수를 제공하는 것이 현실적인 대안이 될 것이다.

  • PDF

Design of Multipurpose Phantom for External Audit on Radiotherapy

  • Lim, Sangwook
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.122-129
    • /
    • 2021
  • Purpose: This study aimed to design a multipurpose dose verification phantom for external audits to secure safe and optimal radiation therapy. Methods: In this study, we used International Atomic Energy Agency (IAEA) LiF powder thermoluminescence dosimeter (TLD), which is generally used in the therapeutic radiation dose assurance project. The newly designed multipurpose phantom (MPP) consists of a container filled with water, a TLD holder, and two water-pressing covers. The size of the phantom was designed to be sufficient (30×30×30 cm3). The water container was filled with water and pressed with the cover for normal incidence to be fixed. The surface of the MPP was devised to maintain the same distance from the source at all times, even in the case of oblique incidence regardless of the water level. The MPP was irradiated with 6, 10, and 15 MV photon beams from Varian Linear Accelerator and measured by a 1.25 cm3 ionization chamber to get the correction factors. Monte Carlo (MC) simulation was also used to compare the measurements. Results: The result obtained by MC had a relatively high uncertainty of 1% at the dosimetry point, but it showed a correction factor value of 1.3% at the 5 cm point. The energy dependence was large at 6 MV and small at 15 MV. Various dosimetric parameters for external audits can be performed within an hour. Conclusions: The results allow an objective comparison of the quality assurance (QA) of individual hospitals. Therefore, this can be employed for external audits or QA systems in radiation therapy institutions.

개인선량계 교정을 위한 환산인자 계산 (Conversion Factors for Calibration of Personnel Dosimeters)

  • 이원구;이태영;하정우
    • Journal of Radiation Protection and Research
    • /
    • 제16권1호
    • /
    • pp.25-32
    • /
    • 1991
  • MCNP 코드를 사용하여 LAEA에서 권고하고 있는 물팬톰과 미국내 선량계 성능시험 프로그램에서 규정하고 있는 PMMA 펜톰내 0.07mm 및 10mm 깊이에서의 환산인자 H(d)/Ka을 계산하였다. 계산은 팬톰의 한면에 수직으로 입사하는 단일에너지 광자의 확장정열범에 대해 수행하였다. 결과는 팬톰내에서 정의되는 선량당량으로 선량계를 교정할 때 환산인자로 사용될 수 있다.

  • PDF

불균질부 방사선치료 시 계획 선량의 정확성 평가 (Evaluation of Planning Dose Accuracy in Case of Radiation Treatment on Inhomogeneous Organ Structure)

  • 김찬용;이제희;곽용국;하민용
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.137-143
    • /
    • 2013
  • 목 적: 불균질부를 포함하고 있는 치료부위의 치료계획 시 불균질 경계면에서의 TPS상 선량분포와 phantom을 이용하여 측정된 실제 선량분포를 비교하여 그 차이를 알아보고자 한다. 대상 및 방법: 4 cm 두께의 solid water phantom 사이에 폐와 유사한 밀도를 가진 8 cm 두께의 cork (density: 0.23 $g/cm^2$)를 위치시켜 phantom을 제작하여 CT 영상을 획득하였으며, 본원에서 사용하고 있는 Pinnacle 치료계획 시스템의 Collapsed-cone(CC) convolution 선량계산 알고리즘을 이용하여 6/15 MV 광자선으로 치료 계획된 선량분포와 실제 phantom에 EBT2 필름을 삽입해 측정한 선량을 비교 평가하였다. 또한 실제 폐암 환자와 유사한 치료계획을 비교하기 위해 Phantom 내부에 치료하고자 하는 종양부위(target volume)로 가정한 파라핀($3{\times}3{\times}3$ cm)을 Location "A" (일반조직과 떨어져있는 가상의 종양: 섬모델)와 Location "B" (일반조직과 붙어있는 가상의 종양: 반도모델)에 삽입하여 CT scan 후 치료계획을 시행하였다. 선량계획과 동일한 조건으로 Phantom을 set-up 후 Phantom의 paraffin target volume 경계면 A (Ant방향), B (Rt방향), C (Post 방향) point에 필름을 삽입하고 방사선을 조사하여 측정된 선량을 TPS선량과 비교평가 하였다. 결 과: 불균질 phantom을 이용한 계획선량과 측정선량과의 차이는 solid water와 cork 경계면을 제외한 부분에서 선량차이가 크지 않았지만 밀도가 급격히 변화하는 첫 번째 구간과 두 번째 구간에서 -5.4%~-12.6%의 선량감소를 보였다. 또한 paraffin target을 삽입한 실험에서는 Location "A"의 경우 실제 측정선량이 A, B, C point에서 각각 -2.5~-4.7%, -2.3~-2.8%, -4.5~-8.8%의 낮은 선량을 나타냈으며, Location "B"의 경우에도 A, B, C point에서 각각 0.08~5.27%, -3.17~-4.74%, -7.86~-11.56%의 선량 차이를 나타내었다. 결 론: 이번 연구의 결과 불균질부 내에서의 치료계획 시스템의 계획된 선량과 실제 측정된 선량에 오차의 가능성이 확인되었다. 급속도로 발전하고 있는 방사선 치료기술과 그만큼 정밀함을 요하는 치료계획 시 이러한 가능성에 대해 인지하고 선량검증에 대한 여러 방법들을 연구하고 개발하는 것이 치료의 발전과 필수적으로 동반되어야 할 것이며 본원에서도 이번 연구를 통해 치료계획 시 발생할 수 있는 변수에 대해서 더 주의 깊게 판단하고 적용할 수 있을 것으로 사료된다.

  • PDF

인터벤션 하지 혈관조영검사를 위한 보조기구의 유용성 평가 (Utility Evaluation of Supportive Devices for Interventional Lower Extremity Angiography)

  • 공창기;송종남;정문택;한재복
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.613-621
    • /
    • 2019
  • 하지 혈관조영검사에서 움직임을 줄이기 위한 방법으로 재질별 하드보드지, 포맥스, 폴리카보네이트, 아크릴을 사용하여 고정용 보조기구를 제작하였고, 제작된 재질별 Phantom의 정량적 화질평가를 위해 마스크 영상, DSA 영상, Roadmap 영상을 SNR과 CNR로 분석하여 보조기구의 유용성을 알아보고자 하였다. DSA 기법으로 하지 Phantom 만을 사용하여 촬영한 마스크 영상과 보조기구 위에 하지 Phantom을 올려놓고 촬영한 마스크 영상의 SNR과 CNR을 비교한 결과 SNR은 약 0~0.06(0~10%), CNR은 약 0~0.003(0~5.36%)정도의 낮은 차이를 확인 하였다. DSA 기법으로 혈관모형의 Water Phantom 만을 사용하여 촬영한 영상과 보조기구 위에 Water Phantom을 올려놓고 촬영한 영상의 SNR과 CNR을 비교한 결과 SNR은 약 0.11~0.35(0.78~2.47%), CNR은 약 0.016~0.031(0.18~2.85%) 정도의 낮은 차이를 확인 하였다. Roadmap 기법으로 Water Phantom 만을 사용하여 촬영한 영상과 보조기구(하드보드지, 포맥스, 폴리카보네이트, 아크릴) 위에 water Phantom을 올려놓고 촬영한 영상의 SNR과 CNR을 비교한 결과 SNR은 0.02~0.05(0.54~1.38%), CNR은 0.002~0.004(1.96~3.70%) 정도의 낮은 차이를 확인 하였다. 결과적으로 보조기구를 사용하지 않았을 때와 보조기구(하드보드지, 포맥스, 폴리카보네이트, 아크릴)을 사용하였을 때를 비교 했을때 SNR과 CNR의 차이가 낮아 보조기구의 사용이 화질의 미치는 영향이 적다고 판단된다. 환자 고정을 위한 보조기구의 사용은 움직임에 따른 조영제 사용량 감소, 시간적 측면 감소, 방사선 피폭 감소, 위험요소의 제거 등에 유용하게 사용할 수 있으며, 보조기구 제작에 대한 각각재료들의 장점은 많으나 본 연구에서 하드보드지 경우 다른 재료에 비해 가격이 저렴하고, 가공이 쉬운 장점을 가지고 있어 검사 및 시술에서 쉽게 적용이 가능할 것으로 판단된다. 검사자가 보조기구를 제작하여 사용 할 때 각 검사의 목적 및 방법에 맞게 재질의 특성, 경제성을 고려하여 사용하는 것이 유용할 것으로 판단된다.

양방향 흐름 팬텀 모델에서 탄산수의 도플러 유체 효과 연구 (Study of Doppler Fluid Effects of Carbonated Water in a Bi-directional Flow Phantom Model)

  • 김지혜;허영철
    • 한국방사선학회논문지
    • /
    • 제18권2호
    • /
    • pp.83-91
    • /
    • 2024
  • 본 연구에서는 양방향 흐름 팬텀 모델에서 탄산수의 도플러 유체 효과를 확인하고자 하였다. 양방향 흐름 팬텀 모델은 동맥과 정맥의 흐름을 구현한 것이며 이중 수조 구조를 통해 유체의 순환이 가능하고 팬텀의 크기를 줄일 수 있게 고안되었다. 사용된 유체는 탄산수, 소금물, 설탕물, 증류수를 이용하였고 수조 표면에서 깊이 1.5 cm, 3.0 cm에서 초음파 B-mode와 컬러 도플러 효과를 이용해 초음파 스캔하였다. 컬러 도플러 효과는 탄산수, 소금물, 설탕물, 증류수 모두 도플러 시프트 효과를 나타냈으나 탄산수의 도플러 시프트 효과가 가장 높았고 깊이에 따른 변화에서도 탄산수의 도플러 시프트 효과 편차가 가장 적었다. 결론적으로 탄산수의 도플러 유체 사용 가능성을 확인할 수 있었고 탄산수의 기포가 적혈구의 도플러 반사체 역할을 하고 있음을 확인하였다. 따라서 도플러 초음파 팬텀 제작에서 혈액 모방액과 유사한 물질로 탄산수를 이용한 추가 연구가 필요하며 이에 본 연구가 기초자료를 제공할 것이라 사료 된다.

고 에너지 전자선에서 물등가 고체팬톰을 이용한 물 흡수선량 측정에 관한 연구 (A Study on the absorbed dose to water for high energy electron beams using Water equivalency of plastic phantom)

  • 신동호;신동오;김성훈;박성용;지영훈;안희경;강진오;홍성언
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.166-169
    • /
    • 2004
  • IAEA의TRS-398물 흡수선량 표준 프로토콜에서 고 에너지 전자선의 물 흡수선량 결정에 있어서 10MeV이하의 에너지 에서만 사용하길 권고하고 있다. Plastic Water$^{TM}$ Virtual Water$^{TM}$ 고체 팬톰을 이용하여 전자선에 대한 hpl값을 측정하였다. 측정결과 Plastic Water$^{TM}$의 경우 6 MeV에서 20 MeV가지의 전자선에 대해 평균 0.9964의 값을 나타냈고, Virtual Water$^{TM}$의 경우 1.0156의 값을 나타냈다.

  • PDF

Development of a Pelvic Phantom for Dose Verification in High Dose Rate (HDR) Brachytherapy

  • Jang, Ji-Na;Suh, Tae-Suk;Huh, Soon-Nyung;Kim, Hoi-Nam;Yoon, Sei-Chul;Lee, Hyoung-Koo;Choe, Bo-Young
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.150-153
    • /
    • 2002
  • High dose rate (HDR) brachytherapy in the treatment of cervix carcinoma has become popular, because it eliminated many of the problems with conventional brachytherapy. In order to improve clinical effectiveness with HDR brachytherapy, dose calculation algorithm, optimization procedures, and image registrations should be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom irradiated. Therefore, the humanoid phantom should be designed such that the dose distributions could be quantitatively evaluated by utilizing the dosimeters with high spatial resolution. Therefore, the small size of thermoluminescent dosimeter (TLD) chips with the dimension of 1/8" and film dosimetry with spatial resolution of <1mm used to measure the radiation dosages in the phantom. The humanoid phantom called a pelvic phantom is made of water and tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators are inserted into the grooves of the applicator supporters. The dose distributions around the applicators, such as Point A and B, can be measured by placing a series of TLD chips (TLD-to- TLD distance: 5mm) in three TLD holders, and placing three verification films in orthogonal planes.

  • PDF