• Title/Summary/Keyword: water line

Search Result 2,147, Processing Time 0.033 seconds

Investigated Selection Method of Electric Corrosion for Corrosion Prevention of Water Pipe Line (송수관로 부식방지를 위한 전기방식 선정 방법 고찰)

  • Lee, Eun-Chun;Shin, Gang-Wook;Hong, Sung-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.358-360
    • /
    • 2000
  • Measurement and analysis for earth resistivity and grounding resistance of Jeon-Ju's widearea-waterworks water pipe line. This result propose to improvement method for exactness analyze the causes for lack of corrosion voltage.

  • PDF

Sensory Function Research of Ichthyic Lateral Line and Development of Lateral Line Teaching Aid. (어류의 옆줄 감각기능 연구 및 옆줄 교구 개발)

  • Kwoon, Jung Hyeon;Kim, MI Jeong
    • Korean Educational Research Journal
    • /
    • v.39 no.1
    • /
    • pp.15-38
    • /
    • 2018
  • This study aimed to confirm that the lateral lines of fish indicate water temperature, water pressure, water flow, and sound waves by conducting a direct experiment. To confirm the superiority of fish lateral lines to detect material stimuli after the experimental study of the fish lateral line's sensation function, the lateral line's tissue was expanded and the shape of the lateral side of the fish was created using a 3-D printer to realize the lateral stripe parity. The amplification effect was confirmed by measuring the sound waves, which was the material stimulus of the lateral diagonal parabola. This proved that fish lateral lines are biotechnologically superior sensory organs.

  • PDF

Development of Wireless Integrated System for Managing Water Tank (저수조 무선 통합 관리 시스템 개발)

  • Jung Kyung-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.6
    • /
    • pp.16-25
    • /
    • 2006
  • Most water tanks operating have been managed by people's five senses. A human material resource have been wasted awfully at this. In the present study, we suggest the wireless integrated system for managing water tank of reducing the wastage human resources and on-line real time managing efforts of water tanks. Water level sensor works the pump sending the data from water tank control to the wireless control on sensing water level. At this time, every kind data which happens in the water tank transmits the line transmission modem. Data to be received from the line transmission modem is stored at the database after we record the logs by each hour. We display the result to the web pages, after checking the pump motion, the pump error, the water level, the solar battery error, the chemicals, and the telephone line to the foundation data to be saved. Furthermore, this paper suggests empirical applications of the proposed wireless integrated system for managing water tank in order to verify its feasibility.

  • PDF

The Effects of DoDamTanghapChongMungTang(Daotantanghecongmingtang) on LPS induced-Microglia and Memory Deficit Mice Model (도담탕합총명탕(導痰湯合聰明湯)이 LPS로 처리된 microglia 및 기억력 감퇴 생쥐 모델에 미치는 영향)

  • Park, Dae-Myung;Lee, Sang-Ryong;Jung, In-Chul
    • Journal of Oriental Neuropsychiatry
    • /
    • v.22 no.2
    • /
    • pp.107-128
    • /
    • 2011
  • Objectives : This experiment was designed to investigate the efficacy of DDTCMT hot water extract & ultra-fine powder on Alzheimer's Disease Model. Methods : The effects of the DDTCMT hot water extract on expression of IL-$1{\beta}$, IL-6, TNF-${\alpha}$, COX-2, NOS-II, IL-10, IL-1 receptor antagonist mRNA and production of IL-$1{\beta}$, IL-6, TNF-${\alpha}$ in BV2 microglial cell line treated by lipopolysacchaide(LPS) were investigated. Expression of NO, ROS in BV2 microglial cell line treated by LPS and AChE activity in PC-12 cell treated by NGF were investigated. anti-AChE was observed through Western blot analysis. The effects of the DDTCMT hot water extract & ultra-fine powder on the behavior of the memory deficit mice induced by scopolamine were investigated. Results : 1. The DDTCMT hot water extract significantly decreased the production of mIL-6, mNOS-II, mTNF-${\alpha}$, and increased the production of mIL-10, mIL-1 receptor antagonist. 2. The DDTCMT hot water extract significantly suppressed the production of IL-$1{\beta}$, IL-6, TNF-${\alpha}$ in BV2 microglial cell line treated by LPS. 3. The DDTCMT hot water extract significantly suppressed the NO and ROS production in BV2 microglial cell line treated by LPS. 4. The DDTCMT hot water extract groups showed inhibition of AChE activity in NGF treated PC-12 cell line. 5. The DDTCMT hot water extract suppressed anti-AChE expression in NGF treated PC-12 cell line was observed by Western blot analysis. 6. The DDTCMT hot water extract & ultra-fine powder groups showed significantly inhibitory effect on the scopolamine -induced impairment of memory in the experiment of Morris water maze. Conclusions : These results suggest that the DDTCMT hot water extract & ultra-fine powder may be effective for the prevention and treatment of Alzheimer's disease.

Application & Examination of the Plan for Optimum Stability through Water-hammer in Pipe Line and Booster Pump Station (관로계통 및 가압펌프장 수격에 따른 최적 안정성 확보방안)

  • Ra, Beyong-Pil;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.19-24
    • /
    • 2009
  • This paper is performed to find out the stability of water-hammer in pipe line and pump station that is happened when additional water needs demanded. At first, the water supply construction project is planned to supply $6,000\;m^3/day$ through 17.9 km pipe line. But additional demand ($1,200\;m^3/day$) happened from Cheong-ra water reservoir. In this situation, air-chamber($4\;m^3$) and vacuum breaker valve(${\varphi}100\;mm$) are needed to prevent water-hammer. When the additional water is supplied, the existing facilities (air-chamber, vacuum breaker valve) are sufficient to alleviate shock not changing capacity alteration, judging from the airspace change and rise. Therefore, there is no problem for water-hammer by installing air-chamber($4\;m^3$) and vacuum breaker valve(${\varphi}100\;mm$) at the top of Yeo-ju hill.

Most suitable design method of post-chlorination process in portable water process by using CFD (전산유체를 활용한 정수공정에서 후염소 투입공정 최적설계 방안)

  • Cho, Youngman
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.331-337
    • /
    • 2013
  • Post-chlorination for disinfection in portable water process is final process. The design factors of post-chlorination are inflow pipe line from tank of filtrated water to cleanwell, injection point of chlorine, appropriate shape of baffle in cleanwell for disinfection efficient improvement. Until now, we did not have the design standard for post-chlorination. we evaluated most suitable design method of post-chlorination process in portable water process by using computational fluid dynamics in this research. We found the result that the pipe to connect the cleanwell should be one. If pipe line split into two or more, uniform distribution of the flow is difficult. Second, optimal injection point of chlorine is the middle of pipe line to connect the cleanwell. Therefore, it is not economical to install chlorine contact basin in cleanwell. Third, the shape of baffle should be designed in order to water flows in one direction. And we found that it is better to design the low number of flow turning.

Effect of Mixing Elements in Line Mixer on Mixing and Flow Characteristics (혼화 및 유동특성에 미치는 라인믹서 내 혼합요소의 영향)

  • Yu, Dae-Gyeom;Lee, Kye-Bock
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.437-443
    • /
    • 2018
  • This study investigates the effect of the mixing elements on the pressure loss and mixing performance in line mixer. The high density ozone water devices mixed with gas and liquid are used in various fields such as sterilizing of group feeding facilities and water quality management at a fish farm. Due to the decrease in rainfall due to climate change, pasteurization of drinking water from ground water and surface water is extremely important. Therefore, it is intended to develop a line-mixed gas liquid mixer with a small amount of space. In this study, the effects of the number of static mixers and the types and the number of the orifice used in line mixer on the volume fraction and the pressure loss were studied by CFD simulation. The pressure drops of line mixer with orifice which curved vanes were attached to were down to more than 50 percent of that of line mixer with static mixer whereas the mixing performance of the former was similar to that of the latter.

Numerical Study on Improvement of Mixing Equipment' Plan in a Water Treatment Plant (수리해석을 이용한 정수장내 혼화장치 설계 개선에 관한 연구)

  • Oh, S.Y.;Hyun, D.S.;Oh, J.J.;Lee, S.H.;Lee, N.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.777-782
    • /
    • 2001
  • In this study, we used In-line orifice mixer for efficient chemicals mixing in water treatment. The method of using In-line orifice mixer has been already proved the improvement of water treatment efficiency. Numerical study was performed using FLUENT, a commercial code, to standard design and production of effective In-line orifice mixer. As variable for exactly standardizing, a proper ratio between an outer diameter of cone and a diameter of pipe, a distance between cone and orifice, a determination of orifice diameter for an optimal mixing, a distance between injection nozzle's position and cone, Numerical study has been performed for optimal standard and analyzed flow field on a basis of turbulent intensity in an orifice downstream.

  • PDF

Evaluation of Head Loss within In-Line Mixer for Water Treatment using CFD Technique (CFD모사 기법을 이용한 관내 혼화장치내 수두손실 발생 특성 평가)

  • Hwang, Young-Jin;Lim, Sung-Eun;Kim, Seong-Su;Park, No-Suk;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.107-112
    • /
    • 2009
  • This study was conducted for verification and systematization of estimation method about the headloss using CFD(Computational Fluid Dynamics). Head loss which happens between the inlet and outlet of in-line mixer can be a major factor for the design and construction. Also, this Case studies about the sensitivity related to the velocity in the piping system. As result, program's default calculation function was used to get each side's total pressure and the differential of each total pressure could be defined as head loss from in-line mixer. In the case of adopting pipe surface friction factor and geometry loss, Calculation residual can be much more reduced. It was found that residual of value between CFD method and field test ranged about 3 through 18 precent.

Reduced Density Matrix Theory for Vibrational Absorption Line Shape in Energy Transfer Systems: Non-Condon Effects in Water

  • Yang, Mi-No
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.439-443
    • /
    • 2011
  • Using the projection operator technique, a reduced density matrix theory for linear absorption spectrum of energy transfer systems is developed for the theoretical absorption line shape of the systems with non-Condon transitions. As an application, we considered a model system of OH vibrations of water. In the present model calculation, the OH vibration modes are coupled to each other via intra-molecular coupling mechanism while their intermolecular couplings are turned off. The time-correlation functions appearing in the formulation are calculated from a mixed quantum/classical mechanics method. The present theory is successful in reproducing the exact absorption line shape. Also the present theory was improved from an existing approximate theory, time-averaged approximation approach.