• 제목/요약/키워드: water level control

검색결과 1,956건 처리시간 0.033초

음용수질의 안정성을 위한 부식지수제도의 도입 (Introduction of Corrosion Index System for Stability of Drinking Water Quality)

  • 김영관;김진근
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.707-717
    • /
    • 2011
  • Replacement of old water distribution pipes for protecting water quality induced by pipe corrosion requires enormous budget. Even after the replacement, however, corrosion can occur again at any times and, therefore, inhibitive measure of the corrosion will be not only economical but needed to diminish the consumers' distrust on tap water quality. In 2008, National Environmental Research Institute did a survey on 8 major drinking water source and proposed to establish the Langelier Saturation Index(LI) as a corrosion index in Drinking Water Quality Criteria. Among the water industries of Korea, K-Water is the only one that set up the level of pH over 7.0 and LI above -1.5 on yearly average basis. However, no systematic regulation including LI to inhibit the corrosive tendency has been established yet. In this paper, LI values out of 31 drinking water treatment plants were analyzed and two-stage control of LI value as a measure of corrosive tendency of water is proposed. Primarily, water treatment facilities may operate the system at a target LI value below -1.5. Following the investigation on the effect caused by adjusting the LI value on water quality and corrosiveness, it will be desirable to improve LI value below -1.0 in the long run. In addition to the LI, supplemental use of Larson's modified ratio (LMR) which incorporates hydraulic detention time will be necessary. Several methods to prove the inhibitive effect of improving the LI value on water quality have been also suggested.

토마토의 암면과 코이어 자루재배시 일사량제어법과 배액전극제어법에 의한 급액제어 방법 비교 (Comparison on Irrigation Management Methods by Integrated Solar Radiation and Drainage Level Sensor in Rockwool and Coir Bag Culture for Tomato)

  • 김성은;심상연;김영식
    • 생물환경조절학회지
    • /
    • 제19권1호
    • /
    • pp.12-18
    • /
    • 2010
  • 토마토를 대상으로 암면과 코이어를 사용한 자루재배에서 일사량제어와 배액전극제어법의 급액제어 능력을 실험한 결과, 배지 종류에 관계없이 일사량제어법에 비해 배액전극제어법에서 배지함수량과 배액량이 안정 적이었다. 총수확량과 상품과량은 배액전극제어법에서 많았으며, 동일한 급액제어 처리 안에서는 배지간 차이는 없었다. 당도는 급액제어 방법의 차이보다는 배지의 종류에 영향을 많이 받았다. 배액전극제어법은 펄라이트뿐만 아니라 암면과 코이어배지에서도 범용적으로 일사량제어법에 비해 유리한 것으로 나타났다.

용육조위탕(龍肉調胃湯) 경구투여가 노화 흰쥐의 면역활성에 미치는 영향 (The Effect of Oral Administration of Yongyukjowi-tang on the Immune Activity in Aged Rat)

  • 이한얼;안택원
    • 사상체질의학회지
    • /
    • 제24권4호
    • /
    • pp.62-74
    • /
    • 2012
  • Objectives : The purpose of this study is to investigate the effect of oral administration of Yongyukjowi-tang(YJT) on the immune activity in aged Sprague-Dawley rat(SD rat). Methods : SD rats were divided into three groups: Yongyukjowi-tang groups(YJT groups), distilled water groups(control groups) and Vitamin C groups(positive control groups) which were administered an oral dose(1ml/1day) to 6, 48 and 68 weeks old SD rats for four weeks. After four weeks, the number of total leukocyte, CD3+, CD4+, CD8+, and the level of cytokine (IL-2, IL-4, IL-10, IFN-${\gamma}$) were measured in spleen tissue of each SD rats. Results and Conclusions : 1) The number of total leukocyte significantly increased in 52 weeks old YJT group and 72 weeks old YJT group in comparison with those of the control group. 2) The number of CD3+ cell significantly increased in 72 weeks old YJT group in comparison with those of the control group and the positive control group. 3) The number of CD8+ cell significantly increased in 52 weeks old YJT group in comparison with those of the control group. 4) The level of IL-2 significantly increased in 72 weeks old YJT group in comparison with those of the control group and the positive control group. 5) The level of IL-4 significantly increased in 52 weeks old YJT group in comparison with those of the positive control group. These results suggest that oral administration of YJT has an effect on increase of immune activity in aged rat.

사이펀 여수로 공기혼입장치(air slot)의 방류량 조절 능력에 대한 실험 연구 (Experimental Study for Capability of Air Slot in Siphon Spillway to Control Outflow Discharge)

  • 정재상;장은철;이창훈
    • 대한토목학회논문집
    • /
    • 제39권6호
    • /
    • pp.703-712
    • /
    • 2019
  • 본 연구에서는 수리모형실험을 통해 사이펀 여수로에 장착된 공기혼입장치(air slot)의 방류량 조절 능력을 검토하였다. 공기혼입장치의 단면 형상으로 원호 및 직사각형 형상을 채택하였으며, 개구부 면적을 조절할 수 있게 하였다. 공기혼입장치가 장착된 경우 사이펀 관 내부에 공기와 물이 혼합된 복잡한 흐름이 발생하였다. 공기혼입장치가 장착된 사이펀 여수로에서 저수지 내측 수위가 상승할 때와 하강할 때 동일한 수위에서 동일한 유량이 계측되었다. 공기혼입장치의 무차원 개구부 면적이 증가할수록 일정한 수두차 및 저수지 수위 조건에서 무차원 방류량은 감소하였다. 수리모형실험 결과는 공기혼입장치의 면적 조절을 통해 사이펀을 통한 방류량 조절이 가능함을 보여주었다.

Regulatory Role of Nitric Oxide on Atrial Natriuretic Peptide System in Normotensive and Hypertensive Rats

  • Choi, Eun-Hah;Kim, Mi-Won;Lee, Jong-Un
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제1권1호
    • /
    • pp.79-82
    • /
    • 1997
  • The present study was aimed to explore an interaction between endothelium-derived nitric oxide (NO) and atrial natriuretic peptide (ANP) systems in normotensive and hypertensive states. Rats were made two-kidney, one clip (2K1C) hypertensive and supplemented with either $N^G-nitro-L-arginine$ methyl ester (L-NAME, 5 mg/100 ml drinking water) or L-arginine hydrochloride (400 mg/100 ml drinking water). One group supplied with normal tap water served as control. Sham-clipped rats were also divided into the L-NAME, L-arginine, and control groups. The plasma levels and atrial contents of ANP were determined at day 28 following clipping the renal artery. In 2K1C rats, the plasma level of ANP was higher and the atrial content was lower than in the sham-clipped control. L-Arginine increased the atrial content of ANP in association with a decreased plasma ANP, whereas L-NAME significantly affected neither parameter. The increase of blood pressure in 2K1C rats was not affected by L-arginine or L-NAME. In sham-clipped rats, the plasma level of ANP was significantly increased by L-NAME along with an increase in blood pressure. On the contrary, L-arginine did not affect the blood pressure or plasma ANP. The atrial content of ANP was significantly altered neither by L-arginine nor by L-NAME. These results suggest that NO plays a tonic inhibitory role on the ANP release with concomitant increases of the atrial tissue content. In addition, hypertension is suggested to modify the release and tissue storage of ANP.

  • PDF

Killing Effects of Different Physical Factors on Extracorporeal HepG2 Human Hepatoma Cells

  • Zhang, Kun-Song;Zhou, Qi;Wang, Ya-Feng;Liang, Li-Jian
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권3호
    • /
    • pp.1025-1029
    • /
    • 2012
  • Objective: To determine the killing effects on extracorporeal HepG2 cells under different temperatures, pressures of permeability and lengths of treatment time. Method: According to different temperatures, pressures of permeability and lengths of treating time, extracorporeal HepG2 cells of human hepatoma cell-line were grouped to 80 groups. Cell index (CI) as the measurement of killing effect were calculated by monotetrazolium (MTT) methods, i.e., CI =1- (the OD value in treated group - the OD value in blank control group) / (mean of untreated control group - mean of blank control group). According to the factorial design, data were fed into SPSS 10.0 and analyzed by three-way ANOVA (analysis of variance). Result: Temperature, pressure of permeability and length of treating time all had effects on the CI (cell index) level. Length of treating time was the most influential factor of the three. Additionally, any two of them all had statistically significant interactive effects on the CI level. When treated for 5-30 min, destilled water at $46^{\circ}C$ stably generated the highest CI. Conclusion: The "$46^{\circ}C$-destilled water-60 min" was considered as the optimal combination of conditions which lead to highest CI. We suggest exerting celiac lavage for 15 min with stilled water at $40^{\circ}C-43^{\circ}C$ in surgical practice as a hyperthermia treatment to achieve ideal killing effects on free cancer cells, which is feasible, practical, and clinically effective.

해안 매립지에서 과거 해안선의 산정 (II): 해안선변화 분석 (Estimation of Historical Shorelines on a Coastal Reclaimed Land (II) : Shoreline Change Analysis)

  • 김백운;이창경
    • 한국해안·해양공학회논문집
    • /
    • 제21권5호
    • /
    • pp.380-390
    • /
    • 2009
  • 본 연구는 우리나라 남동 해안에 위치한 매립지(안정국가산업단지, 명지주거단지 및 녹산국가산업단지)에서 해안빈지 면적 산출을 위하여 항공사진으로부터 매립이전의 해안선을 조사하는 연구의 일환으로 수행되었다. 매립 이전 해안선의 적합성을 평가하고자 해안선변화자료를 구축하였다. 2차적인 지상기준점으로 오래된 항공사진의 항공삼각측량을 수행하였다. 해안선은 약최고고조위(AHHWL)에 해당하는 해안선과 wet/dry 흔적에 의한 고조선(HWL)을 도화하였다. 인공적인 해안에서 두 종류의 해안선은 잘 일치하였다. 항공사진 축척, 품질, 지상기준점 선정, 해안선 인식 등 세부적인 차이로 인하여 해안선변화자료는 다양한 오차수준으로 구성되었다. 정성적인 해안선변화 추이를 살펴보는 수준에서 매립 이전 해안선의 적합성은 만족할 만하였다. 본 연구지역에서 매립 이전의 해안선 변화는 대부분이 연안개발로 발생하였다. 항공사진과 연계하여 해안선의 속성을 파악함으로써 해안선 변화에 대한 이해가 가능하였다.

Effect of Short-term Water Restriction on Body Weight, Egg Production, and Immune Response of Local and Commercial Layers in the Late Phase of Production

  • Ahmed, A.S.;Alamer, M.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제24권6호
    • /
    • pp.825-833
    • /
    • 2011
  • Forty-five Hisex commercial layers and forty-five local Saudi breed layers were used to determine the acceptable limit of short-term water restriction in the late phase of production, when the problem of high feed and water consumption is expected. The experiment was performed under hot and arid environmental conditions when the layers were at fifty weeks of age. Layers from each breed were randomly assigned in groups of five into nine floor pens. The average environmental temperature was 37.2-$38.6^{\circ}C$, and the relative humidity was between 20 to 37%. The trial was divided into 3 periods; control (1 week), water restriction (2 weeks) and rehydration (1 week). During the restriction period, layers from each breed were divided into three groups that received 20, 40, and 0% restriction of drinking water relative to their consumed water during the control period. During the study, feed and water consumption, body weight, changes in body weight, egg production, primary antibody response to SRBC, and rectal temperature were evaluated. Water restriction did not result in any clear effect on feed intake in either breed, however, commercial layers tended to consume less feed compared to the local breed. Body weight declined with water restriction during the first week of restriction in the commercial breed regardless of rate of restriction, but it was delayed until the second week in the local breed. Water restriction of 40% decreased egg production in both breeds but with a delay of 1 week in the local breed. Antibody level to SRBC was not affected by water restriction in the commercial line while it was highly affected in the local breed. A water restriction of 20% is considered to be an acceptable limit under the current experimental conditions without a negative effect on egg production in both breeds and considering the immune status of the local breed. Whereas, 40% restriction had a negative effect on egg production, and varied effects in the other traits in both breeds.

비점오염원 관리지역(소양호) 목표수질 달성도 평가 (Assessing the Action Plans in the Control Area(Soyang Reservoir) of Non-point Source Pollution)

  • 최재완;강민지;류지철;김동일;임경재;신동석
    • 한국환경과학회지
    • /
    • 제23권5호
    • /
    • pp.839-852
    • /
    • 2014
  • The Ministry of Environment (MOE) has made more effort in managing point source pollution rather than in nonpoint source pollution in order to improve water quality of the four major rivers. However, it would be difficult to meet water quality targets solely by managing the point source pollution. As a result of the comprehensive measures established in 2004 under the leadership of the Prime Minister's Office, a variety of policies such as the designation of control areas to manage nonpoint source pollution are now in place. Various action plans to manage nonpoint source pollution have been implemented in the Soyang-dam watershed as one of the control areas designed in 2007. However, there are no tools to comprehensively assess the effectiveness of the action plans. Therefore, this study would assess the action plans (especially, BMPs) designed to manage Soyang-dam watershed with the WinHSPF and the CE-QUAL-W2. To this end, we simulated the rainfall-runoff and the water quality (SS) of the watershed and the reservoir after conducting model calibration and the model validation. As the results of the calibration for the WinHSPF, the determination coefficient ($R^2$) for the flow (Q, $m^3/s$) was 0.87 and the $R^2$ for the SS was 0.78. As the results of the validation, the former was 0.78 and the latter was 0.67. The results seem to be acceptable. Similarly, the calibration results of the CE-QUAL-W2 showed that the RMSE for the water level was 1.08 and the RMSE for the SS was 1.11. The validation results(RMSE) of the water level was 1.86 and the SS was 1.86. Based on the daily simulation results, the water quality target (turbidity 50 NTU) was not exceeded for 2009~2011, as results of maximum turbidity in '09, '10, and '11 were 3.1, 2.5, 5.6 NTU, respectively. The maximum turbidity in the years with the maximum, the minimum, and the average of yearly precipitation (1982~2011) were 15.5, 7.8, and 9.0, respectively, and therefore the water quality target was satisfied. It was discharged high turbidity at Inbuk, Gaa, Naerin, Gwidun, Woogak, Jeongja watershed resulting of the maximum turbidity by sub-basins in 3years(2009~2011). The results indicated that the water quality target for the nonpoint source pollution management should be changed and management area should be adjusted and reduced.

벽면 요철형 동조액체댐퍼의 진동제어성능에 관한 실험적 평가 (Experimental Evaluation on the Vibration Control Effect of Tuned Liquid Damper with Embossment)

  • 주영규;김대영
    • 한국강구조학회 논문집
    • /
    • 제14권6호
    • /
    • pp.765-772
    • /
    • 2002
  • 초고층 건물의 가속도 레벨을 줄이기 위해서 TMD, TLD, VED와 같은 다양한 진동제어장치들이 많은 국내외 연구자들에 의해 연구되고 있다. TLD는 다른 제진장치에 비해 설치의 간편함 및 유지비용이 저렴한 장점이 있다. 그러나 물의 요동을 평가함에 있어서 어려움이 있으므로 동조액체댐퍼의 동적특성에 대한 실험 및 해석적 검증이 필요하다. 본 연구에서는 TLD를 100층 규모의 초고층건물에 설치할 경우를 상정하여 자유진동실험과 백색잡음을 이용한 강제진동실험을 통하여 TLD의 제진성능을 확인하고자 하였다. TLD의 질량비, 감쇠네트수, TLD 형상비 등을 주요실험변수로 설정하였으며, 물탱크를 설치한 건물의 반응값들이 건물 단독인 경우보다 적게 나타남을 알 수 있었다. 또한 질량비, 감쇠네트, 형상비가 커질수록 감쇠성능이 개선됨을 알 수 있었다.