• 제목/요약/키워드: water level control

검색결과 1,956건 처리시간 0.033초

수위 변화에 따른 비점오염의 상수원 수질 영향 분석 (Impact of Non-point Source Runoff on Water Resource Quality according to Water-Level Changes)

  • 최미진;이상현
    • 한국환경과학회지
    • /
    • 제24권8호
    • /
    • pp.1045-1053
    • /
    • 2015
  • This study evaluated the effect of water level of water resources on water quality in Ulsan. Two reservoirs, Sayeon Dam and Hoeya Dam, were selected and water quality of chemical oxygen demand (COD), total nitrogen (TN) and total phosphorus (TP) were analyzed from 2012 to 2014. And the characteristics of precipitation were also analyzed for 70 years (1945~2014) because runoff of non-point pollutant was strongly affected by precipitation. As a result, water deterioration of Sayeon Dam and Hoeya Dam were affected in accordance with lowering water level. For example, the concentrations of COD and TN was negatively correlated with the water level when the water level of Sayeon Dam was gradually decreased in 2013. The TN concentration was increased to 1.432 mg/L from 0.875 mg/L while the lowest water level of Sayeon Dam was recorded 45 m in 2014. Additionally the concentration of COD and TN was sensitively increased with 0.213 mg/L/m and 0.058 mg/L/m on account of non-point pollutant runoff. It is indicated that hereafter a control of non-point pollutant runoff is the critical factors to maintain water resources because the contribution of non-point pollutant is expected to increase due to the frequent heavy rain events. Therefore, it is necessary to map out a specific plan for non-point pollutant control based on analyses of runoff characteristics, water pollution sources and reduction plans in water pollutants and to establish a water modelling and database system as a preventive action plan.

적응제어알고리즘을 이용한 원자력발전소용 증기발생기 수위제어 시스템에 관한 연구 (A study on the microcomputer-based adaptive control system of a steam generator)

  • 배병환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.658-663
    • /
    • 1987
  • The new controller developed here, which is the facility with only one measurement, is a new concept for the level controller of the existing nuclear steam generator. A MACS (Microcomputer-based Adaptive Control System of a Steam Generator) is quite practical and efficient, and has also simple structure and higher flexibility in the installment for actual plant. A key ingredient of this system is adaptive regulator which can calculate adaptive, optimal valve position in response to changes in the dynamics of the process and the disturbances. In spite of many difficulties in the steam generator water level control at low power, it can be concluded from the experimental and simulation results, that the MACS can provide optimal, robust steam generator level control from zero to full power. The amount of the control input effort can be reduced by adjusting the weighting factor. However, the steady state water level errors are generated. To avoid the steady errors, the different adaptive algorithm should be investigated in the future. The 3 second sampling time is acceptable for this system. However, action should be taken to shorten the sampling time for better digital control.

  • PDF

하구방조제의 홍수조절 해석 (Flood control analysis of the sea dike at estuary.)

  • 서승덕
    • 물과 미래
    • /
    • 제10권2호
    • /
    • pp.113-124
    • /
    • 1977
  • Alone the southwesten coast of Korean peninsula, the extensive available arable acreages suited for forming are found in the development of tidal flats in the geographically curved bays with a motable tidal emplitude. It was found that the developments of these tidal flats cover an estimated area more than 276,000ha. In this paper, a flood control system by Pul's Storage Indication Method and Pul's Graphical Method at Return Periods-50 yrs, design rainfall-267mm per 48hrs and design flood-926c.m.s. and at 0.2meter control height above the High Water Ordinary Spring Tide Level (+11.0m) was studied. At the result, the flood demage in the reservoir at Return Periods-50 yrs and the tidal level at H.W.O.S.T.L. were satisfied to the below E.L. 11.20m (Flood Level in the reservoir). Well skilled flood control technique and management and control of draining sluice gate should be required for the disaster prevention from the flood and tide damage.

  • PDF

급수배관시스템의 수충격 진동제어를 위한 실험적 연구 (An Experimental Study on Vibration Control of Water Hammering in Water Pipe System)

  • 이장현;이효행;권병하;오진우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.453-458
    • /
    • 2008
  • Pump of high lift use to development of a technological level according as a building grow big. Water-Hammer to increase by valve of fast to closing agreeably to pipe laying to accept electronic valve, because by a damage of piping-system and the devil knows injury of vibration. Water-Hammer take a low effect to various method for solve. A New type manufacture develop and testing of pipe line to same to axis use to accumulator for water-Hammer to low effect and liner control of pressure. Impact-pressure of absorption ability and confirmation to decrease of vibration level through to preexistence manufactures and comparative test. Water-hammer and pipe vibration make low of piping system.

  • PDF

한국표준형 초 임계압 관류형 보일러의 급수제어 (Feed Water Flow Control of Super Critical Once Through Boiler in Korea Standard Power Plant)

  • 김은기;장용창;조수현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.251-251
    • /
    • 2000
  • Tangjin Power Plant is modern Korean standard plant which is made up Once Through Super Critical Boiler, Turbin, Generator and Flue Gas Desulfarization System. INFI-90 system fur control of the 500 MW Korean standard super critical once through boiler Mark-V for Turbine, EX-2000 fer Generator, WDPF for FGD were installed in Tangiin thermal power plant. There were two BFPTs, BFPM, 25% control valve, 35% control valve to control boiler feed water flow. It is very difficult to tune the Separator Tank level control system and change the mode from Wet to Dry. This paper focuses on test results and modification control logic for feed water control system in Tangjin power plant.

  • PDF

원전 증기발생기 수위제어를 위한 MPC 제어기 개발 (The devlepment of a MPC controller for water level control in the steam generator of a nuclear power plant)

  • 손덕현;한진욱;이환섭;이창구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.359-359
    • /
    • 2000
  • Generally, level control in the steam generator of a nuclear power plant is difficulty process control, because the low power operating can lead nonminimum phase characteristics(swell and shrink phenomenon) and flow measurement are unreliable and nonlinear characteristics. This paper presents a framework for solving this problem based on the constrained linear model predictive control and introduces the design of method for the level of the controller in the entire operating power of the steam generator, and compares with conventional PI controller.

  • PDF

핵증기 발생기의 9룰 퍼지논리 제어기 (A 9-Rule Fuzzy Logic Controller of the Nuclear Steam Generator)

  • Lee, Jae-Young;No, Hee-Cheon
    • Nuclear Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.371-380
    • /
    • 1993
  • 운전원의 언어적인 제어 논리를 이용한 모델과 무관한 제어기가 증기 발생기의 수위 제어를 위해 개발되었다. 오직 9개의 룰을 수위 오차와, 응축 수위 변화를 표현하는 유량 오차로부터 얻어졌다. 벨형의 소속함수는 민감도 분석을 통하여 조절되었고, 결과 과도 상태와 정상상태 공히 양호한 제어성능을 보였다. 저출력에서 전 출력까지의 다단계 출력 증가에 대하여, 전 운전 영역에서 좋은 제어를 보였다.

  • PDF

우리나라 저수지의 용도에 따른 호안 식물상 차이 (Difference in Shoreline Flora According to the Usage of Reservoirs in Korea)

  • 조현석;조강현
    • 한국습지학회지
    • /
    • 제17권4호
    • /
    • pp.339-347
    • /
    • 2015
  • 저수지의 이용목적에 따라서 수력발전용, 농업용수용, 생활 공업용수용 및 홍수조절용으로 구분한 우리나라 35개 저수지의 호안에서 출현하는 관속식물 종류와 지형, 수문, 물 및 토양 환경을 조사하여 이용목적에 따른 호안 환경과 식물상 특성의 차이를 규명하고자 하였다. 호안의 식물상은 저수지의 용도에 따라서 종수, 종류 및 식물종 특성에서 차이를 나타내었다. 단계별 변수선택법 결과에 의하면 저수지 호안의 출현종수는 중앙수위에서 범람빈도가 높고 호안의 연평균노출기간이 길수록 증가하였다. 주좌표분석과 집괴분석의 결과에서 저수지 호안의 식물상은 이용목적에 따라서 크게 3가지 유형, 홍수조절용과 생활 공업용수용, 농업용 및 발전용 저수지로 구분이 되었다. 식물상의 특성에 영향을 미치는 주요한 환경 요인은 연간 수위변동폭, 중앙수위 연범람빈도, LQI 지수 및 연평균노출기간이었다. 수위가 안정적으로 유지되고 수질이 중영양으로 유지되는 발전용 저수지에서는 종풍부도가 높고 침수식물종을 비롯한 수생식물종이 풍부한 연안대가 발달하였다. 수위변동이 심하고 수질이 빈영양 혹은 중영양인 홍수조절용과 생활 공업용수용 저수지 식물상은 수위변동역에서 단명의 교란지식물이 분포하였다. 수위변동이 중간 정도이고 중영양 또는 부영양인 농업용 저수지에서는 부엽식물과 부유식물과 같은 수면을 덮는 식물종이 특징적으로 분포하였다. 결론적으로 저수지 호안의 식물상 특성은 이용목적에 따라서 수위변동, 수질 등의 환경요인이 차이가 나타나고 이에 따라서 식물상의 구조와 종풍부도가 다르게 나타났다.

저출력시 원전 증기발생기 수위제어 개선 연구 (A Study on Improvement of PWR Steam Generator Water Level Control at Low Power Operation)

  • Yun, Jae-Hee;Han, Jai-Bok;Joon Lyou
    • Nuclear Engineering and Technology
    • /
    • 제26권3호
    • /
    • pp.420-424
    • /
    • 1994
  • 가압경수로형 원자력발전소의 저출력 및 과도상태에서의 개선된 증기발생기 수위 제어 방식을 제시하였다. 수축 및 팽창 현상에 의한 수위의 요동을 줄이기 위해 기존의 비례·적분 제어기에 증기발생기 압력 및 급수온도를 고려한 앞먹임 보상부를 첨가하였다. 원전 훈련용 시뮬레이터를 이용하여 시뮬레이션을 수행한 결과 기존방식에 비해 적은 수위오차, 훨씬 빠른 진정시간을 얻을 수 있었다. 제시된 알고리즘은 구현이 용이하고 실제 적용도 가능하리라 판단된다.

  • PDF

퍼지제어모형을 이용한 다목적 댐의 홍수조절모형( I ) - 단일댐의 운영모형 개발 - (Multipurpose Dam Operation Models for Flood Control Using Fuzzy Control Technique ( I ) - Development of Single Dam Operation Models -)

  • 심재현;김지태;허준행;김진영
    • 한국방재학회 논문집
    • /
    • 제4권1호
    • /
    • pp.33-40
    • /
    • 2004
  • 본 연구에서는 치수방재 효과를 향상시키기 위한 단일댐운영 모형을 개발하였으며, 제어기법은 퍼지제어 기법을 사용하였다. 본 모형은 저수지 수위와 유입량을 기준으로 제어규칙을 설정하였으며 방류량을 결정하는 제어기준에 따라 Fuzzy I, II, III의 세가지 모형을 개발하였다. Fuzzy I 모형은 6개의 제어규칙에 의해 홍수조절만을 고려한 것이고, Fuzzy II 모형은 I 모형의 치수효과를 가지면서도 홍수후의 저수위를 상승시켜 이수적인 효과도 얻기 위한 모형이며, Fuzzy III 모형은 적응제어모형으로 제어규칙을 9개로 세분화하여 치수효과와 이수효과를 동시에 거둘 수 있도록 한 모형이다.