• 제목/요약/키워드: water level control

검색결과 1,956건 처리시간 0.029초

정수장 급속여과지 역세척 수위변화와 시간에 따른 세척 효율 평가 (Evaluation of a Rapid Sand Filter with Surface Wash and Backwash Conditions)

  • 정용준;민경석
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.652-656
    • /
    • 2004
  • Both surface wash and backwash are considered as one of the most important methods that can improve the filtration efficiency in the existing water treatment plant. This study has mainly focused on the improvement of filtering efficiency by controlling surface wash and backwash time, and water level before backwash (when drained up to the trough, when drained up to 10 cm above filter bed, and when drained below 10 cm filter bed). Filtration efficiency was shown a little bit of differences depending on the operating conditions like surface wash injection pressure, the distance control between filter bed and the facility, and the types of surface wash. When the water level before backwash was reached up to 10 cm below filter bed after draining, however, the filtration velocity and the turbidity removal efficiency in the filter bed was improved. When the surface wash followed by backwash is longer, it showed a similar result. Because the proper adjustment of surface washing time makes filtration efficiency higher, therefore, it is necessary to set up the backwash time moderately.

Vibration Measurements of an Intelligent Cantilever Beam in Contact with Fluid

  • Kwon, Tae-Kyu;Park, Seong-Hwa;Yu, Gye-Hyoung;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.97.3-97
    • /
    • 2002
  • This paper presents the vibration characteristics of an intelligent cantilever beam in contact with a fluid using a PZT actuator and PVDF film. The dynamic behaviors of a flexible beam-water interaction system are examined. The effect of the liquid level on free vibration of the composite beam in a partially liquid-filled circular cylinder is investigated. The coupled system is subject to an undisturbed boundary condition in the fluid domain. It was found that the coupled natural frequencies decreased with the fluid level for the identical composite beam due to added mass effect. In case of the free-free boundary condition, the natural frequency gently decreased at fluid water level betw...

  • PDF

Occurrence and removals of micropollutants in water environment

  • Kim, Moon-Kyung;Zoh, Kyung-Duk
    • Environmental Engineering Research
    • /
    • 제21권4호
    • /
    • pp.319-332
    • /
    • 2016
  • Micropollutants are often discharged to surface waters through untreated wastewater from sewage treatment plants and wastewater treatment plants. The presence of micropollutants in surface waters is a serious concern because surface water is usually provided to water treatment plants (WTP) to produce drinking water. Many micropollutants can withstand conventional WTP systems and stay in tap water. In particular, pharmaceuticals and endocrine disruptors are examples of micropollutants that are detected at the drinking water, ppb, or even ppb level. A variety of techniques and processes, especially advanced oxidation processes, have been applied to remove micropollutants from water to control drinking water contamination. This paper reviews recent researches on the occurrence and removal of micropollutants in the aquatic environments and during water treatment processes.

하천수 및 정수공정에서의 비소관리를 위한 대체인자 개발 (Development of Alternative Indicator for Arsenic Management in River Basin and Drinking Water Treatment)

  • 강미아;김광태
    • 한국물환경학회지
    • /
    • 제21권6호
    • /
    • pp.659-663
    • /
    • 2005
  • Many studies have been conducted to develop new technologies for arsenic removal and to reveal the levels of arsenic and other chemicals in rivers, lakes and ground waters. However, there are few studies dealing with such compounds in the total water system of the city, and the way of management of these compounds in the water system. Because the occurrence of these hazardous compounds, which are geological origins, is almost impossible to control, it is very important to manage these compounds in the water system. In this research, it was revealed that the risk of arsenic in the water treatment system of S city in Japan. As a results, the parameters such as Q in river and E260 in drinking water treatment plant is proposed as a new indicator with simple and rapid method for controling arsenic level.

모타보트의 소음 측정 및 대책 (The measurement and control of outboard motor)

  • 김대홍;이성태;김건인
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.56-64
    • /
    • 1996
  • In this paper, the sound radiation level of parts of a O.B. Motor was measured and analyzed by the measurement method using wave-guide reverberation environment. Based on the above measurement results, a noise control was established for engine cover and exhaust silencer and its effects were compared and analyzed. The noise control method increased transmission loss by painting GELNAC on the engine cover and extend exhaust pipe to reach under water.

  • PDF

Vibration control of a stay cable with a rotary electromagnetic inertial mass damper

  • Wang, Zhi Hao;Xu, Yan Wei;Gao, Hui;Chen, Zheng Qing;Xu, Kai;Zhao, Shun Bo
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.627-639
    • /
    • 2019
  • Passive control may not provide enough damping for a stay cable since the control devices are often restricted to a low location level. In order to enhance control performance of conventional passive dampers, a new type of damper integrated with a rotary electromagnetic damper providing variable damping force and a flywheel serving as an inertial mass, called the rotary electromagnetic inertial mass damper (REIMD), is presented for suppressing the cable vibrations in this paper. The mechanical model of the REIMD is theoretically derived according to generation mechanisms of the damping force and the inertial force, and further validated by performance tests. General dynamic characteristics of an idealized taut cable with a REIMD installed close to the cable end are theoretically investigated, and parametric analysis are then conducted to investigate the effects of inertial mass and damping coefficient on vibration control performance. Finally, vibration control tests on a scaled cable model with a REIMD are performed to further verify mitigation performance through the first two modal additional damping ratios of the cable. Both the theoretical and experimental results show that control performance of the cable with the REIMD are much better than those of conventional passive viscous dampers, which mainly attributes to the increment of the damper displacement due to the inertial mass induced negative stiffness effects of the REIMD. Moreover, it is concluded that both inertial mass and damping coefficient of an optimum REIMD will decrease with the increase of the mode order of the cable, and oversize inertial mass may lead to negative effect on the control performance.

울진1,2호기 출력최적화 및 증기발생기 교체가 주급수 제어계통 안정도에 미치는 영향연구 (Research on a Stability of Feedwater Control System after Stretched Power Uprate and Replacement Steam Generator for Ulchin Units 1&2)

  • 윤덕주;김인환;이재용
    • 한국압력기기공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.14-20
    • /
    • 2012
  • Full load rejection capability of nuclear power plant depends primarily on steam dump capacity (SDCAP) and steam generator level control capability. Recently, Ulchin Units 1&2 have performed stretched power uprate (SPU) and replacement steam generator (RSG) projects, which increase the power by 4.5 percent. They change major design or operating parameters and especially reduces steam dump capacity at full power due to increase of the steam flow. The reduction of SDC after SPU results in degradation of heat removal capability in full load rejection transients. Therefore, we should perform evaluation to determine whether reactor trips occur in large load rejection transients. Uchin Units 1&2 have experienced full load rejection (FLR) three times from 2004 to 2010. Operating data from the plant occurrence of FLR at Ulchin Units 1&2 showed that steam generator (SG) level transients were limiting in point of reactor trip. However the plant had never reached reactor trip in the FLR and successfully continued in house load operation. The parameters and setpoints for the SG will be changed if the SG is replaced. Therefore, we evaluated the appropriateness of steam dump, main feedwater and steam generator water level control system preventing the plant from reactor trip in case of FLR by the parameter sensitivity study whether SG water level operated smoothly after SPU and RSG projects.

동자개(Pseudobagrus fulvidraco)의 생식소 퇴화에 미치는 수온과 광주기의 영향 (Effect of Water Temperatures and Photoperiods on Gondal Degeneracy in Banded Catfish Pseudobagrus fulvidraco)

  • 임상구;김영수;한창희
    • 수산해양교육연구
    • /
    • 제24권6호
    • /
    • pp.845-853
    • /
    • 2012
  • To investigate the role of temperatures and photoperiods as environmental cues regulating reproductive rhythm in Pseudobagrus fulvidraco, rearing experiments were conducted using sveral rearing regimes conbined with photoperiods and water temperatures during gonadal degeneration periods. Gonadosomatic index (GSI) in control was $8.16{\pm}1.50%$, while in other experiment GSI levels in female were lower than that in the control. In case of experimental precinct of 9 light (L) and 15 L, GSI levels were decreased. But GSI level with $20^{\circ}C$ was no diffrence after 40 and 60 days. GSI level in male of control was $0.35{\pm}0.05%$. GSI under 9 L and $25^{\circ}C$ was similar to that in control, whereas its level in other experiments was lower than that in control. Testosterone (T) of female was $3.68{\pm}0.22$ ng/mL at experimental precinct. In case of 9 L and 15 L, concentration of T were lower than experimental precinct in all of water temperature. Estradiol-$17{\beta}$ ($E_2$) and $7{\alpha}$, $20{\beta}$-dihydroxy-4-pregnen-3-one ($17{\alpha}20{\beta}OHP$) levels of female were $0.42{\pm}0.02$ and $0.83{\pm}0.01$ ng/mL at experimental precinct. $E_2$ levels of 9 and 15 L were higher than experimental precinct and $17{\alpha}20{\beta}OHP$ levels of 9 and 15 L were higher than experimental precinct. In case of T and 11-ketotestosterone levels were $0.69{\pm}0.11$ and $.62{\pm}0.03$ ng/mL in male. During the period of gonadal degeneration, gonadal maturation did not occur in any of the experimental regimes. However, comparatively high levels of $E_2$ observed at low temperature regimes ($20^{\circ}C$) regardless of photoperiods.

흐름상태와 제내지 및 제외지의 표고변화에 따른 제방의 파이핑안정성 평가 (Levee Stability Assessment depending on Level of Inland and Riverside land in Flow State)

  • 강태운;안현욱;김연수;정관수
    • 한국수자원학회논문집
    • /
    • 제48권4호
    • /
    • pp.269-279
    • /
    • 2015
  • 최근 지구온난화로 인한 기상이변으로 전세계가 몸살을 앓고 있다. 우리나라도 같은 실정에 직면해 있으며 이에 대비하는 차원으로 대하천 정비사업을 실시한 바 있다. 제방에 대한 정비항목으로는 하천준설, 제내지와 제외지에 대한 성토 및 보강등이 있으며 이로 인해 지하수 흐름양상이 변하게 될 것으로 추정된다. 그러므로 이와 같은 환경을 시뮬레이션을 통해 제내지와 제외지의 높이에 따른 제방의 파이핑 안정성을 분석해볼 필요가 있는 것으로 판단된다. 따라서 본 연구에서는 낙동강의 지류인 회천에 위치한 율지제를 중심으로 본 연구제방에 설치된 간극수압센서를 이용하여 제내지와 제외지의 표고변화에 따른 제방내부의 지하수 침투양상을 SEEP/W를 이용하여 정상류 및 부정류를 고려한 모의를 수행하고 안정성을 검토하였다. 모의결과, 제내지의 표고가 상승할수록 파이핑 안정성이 증가하는 것으로 나타났으며 제외지측은 표고와는 상관없이 하천수위에 따라 파이핑 안정성이 영향을 받는 것으로 나타났다. 그러므로 제방의 파이핑 안정성을 증대시키기 위해서는 제내지의 성토와 적정하천수위유지와 같은 제방의 외적 요소들도 함께 고려해야할 것으로 판단된다.

한천저류지 운영에 따른 홍수조절효과 평가 (An Evaluation of the Flood Control Effect according to the Hancheon Reservoir Operation)

  • 문덕철;정관수;박원배;김용철
    • 한국수자원학회논문집
    • /
    • 제47권2호
    • /
    • pp.107-117
    • /
    • 2014
  • 본 연구에서는2007년 제주지역을 강타한 태풍 '나리' 이후 홍수조절을 위해 한천유역에 설치된 저류지의 효과를 정량적으로 평가하였다. 이를 위해 2010년 태풍 '뎬무'의 내습 시, 한천 상 하류에 위치한 하천유량관측소의 자료와 저류지 유입량 자료를 이용하여 한천저류지 운영이 하류지역에 미치는 홍수저감 효과를 검토하였다. 분석결과, 하류지역에서의 실제 하천수위는 3.44m를 기록하였으나, 수위-유량 관계식, 유출전파속도, 저류지 유입량 등을 활용하여 저류지가 운영되지 않았을 경우의 하류지역 하천수위를 분석한 결과 4.16m로 예측되었다. 이와 같은 결과는 한천유역에 설치된 저류지의 홍수저감 효과를 분명하게 보여주는 것으로 향후 유사한 사상에 대해서도 적절한 기여를 할 수 있을 것으로 판단되었다.