• Title/Summary/Keyword: water length effect

Search Result 816, Processing Time 0.025 seconds

NEAL-WALL GRID DEPENDENCY OF CFD SIMULATION FOR A SUBCOOLED BOILING FLOW (과냉 비등유동에 대한 CFD 모의 계산에서의 벽 인접격자 영향)

  • In, W.K.;Shin, C.H.;Chun, T.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.320-325
    • /
    • 2010
  • A multiphase CFD analysis is performed to investigate the effect of near-wall grid for simulating a subcooled boiling flow in vertical tube. The multiphase flow model used in this CFD analysis is the two-fluid model in which liquid(water) and vapor(steam) are considered as continuous and dispersed fluids, respectively. A wall boiling model is also used to simulate the subcooled boiling heat transfer at the heated wall boundary. The diameter and heated length of tube are 0.0154 m and 2 m, respectively. The system pressure in tube is 4.5 MPa and the inlet subcooling is 60 K. The near-wall grid size in the non-dimensional wall unit ($y_{w}^{+}$) was examined from 64 to 172 at the outlet boundary. The CFD calculations predicted the void distributions as well as the liquid and wall temperatures in tube. The predicted axial variations of the void fraction and the wall temperature are compared with the measured ones. The CFD prediction of the wall temperature is shown to slightly depend on the near-wall grid size but the axial void prediction has somewhat large dependency. The CFD prediction was found to show a better agreement with the measured one for the large near-wall grid, e.g., $y_{w}^{+}$ > 100.

  • PDF

The effect of Far-infrared on survival rate of mice (원적외선이 흰쥐의 생존율에 미치는 영향)

  • Kim, Jae-Yoon;Park, Seung-Kyu;Kim, Jin-Sang;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.3
    • /
    • pp.561-567
    • /
    • 2001
  • IR classified by wavelength three parts NIR, MIR. FIR. There is FIR which is radiated from healthy human body the wave length is 8-14m. The Sun's ray is composed of Infared(49%), Visible light(40%) and Ultra violet(11%), however the ray getting to the earth is FIR(60%), IR(20%), and UV(20%). Human beings has utilized FIR already from time immemorial. Hershel found out Infrared for the first time, in the Industrial Revolution the Infrared and FIR had been begun to use making products. FIR with low temperature can deeply penetrate on the human body composed things without troublesome, since FIR has effectively operated on the human body at low temperature (35-40 $^{\circ}$C). In this study, we experimented in the specific temperature FlR radiation intensity. water consumption rate, feed consumption rate. survival rate and mean of weight balance with FlR radiation instrument. According to the results, the FlR radiation to the mice assisted to increase the survival rate.

  • PDF

The Effect of Ginseng Saponin Fraction on the Germination and Early Growth of Rice Seed (Oryza sativa L.) (인삼사포닌이 벼의 발아 및 초기 생장에 미치는 영향)

  • 이용우;주충노
    • Journal of Ginseng Research
    • /
    • v.11 no.1
    • /
    • pp.77-83
    • /
    • 1987
  • The effects of ginseng saponin on the germination and early growth of rice seeds (Oryza sativa L.) were investigated. The early growth (length) of test rice seeds which were rinsed for 60 hrs in $10^{-4}$% saponin solution prior to transplantation to water agar bed was about 20% faster than that of control seeds, It was also found that the amylase activity of the seeds was most active when the seeds were rinsed in 10-4% saponin solution for 48 hrs. In vitro investigation showed that the amylase activities were stimulated about 30% by the treatment of $10^{-5}$% saponin solution compared with control group. From the above results, it seems that the ginseng saponin might activate amylase of rice seed during germination, resulting in rapid growth of rice.

  • PDF

Comparative Anatomy of Secondary Xylem in Normal and Dwarf Individuals of Some Wood Plants (수 종의 목본식물에 있어서 정상 및 왜소개체의 이기목부의 비교해부)

  • 임동옥
    • Journal of Plant Biology
    • /
    • v.34 no.1
    • /
    • pp.9-18
    • /
    • 1991
  • This study deals with the effect of dwarf growth on xylem structure, especially on the dimension of xylem elements described for 12 species of naturally occuring dwarf trees. The length and tangential diameter of tracheary elements and fibers in dwarf trees appear to be shorter and narrower than those in normal trees. Radial width and cell number of the same annual rings are narrower and smaller in dwarf trees than those in normal trees. Height of rays in dwarf trees is lower than that in normal trees. Dwarf conifers appear to have higher ratio, of latewood to earlywood than that in normal trees. In the hardwood species studied, mesomorphy of vessel elements is lower in dwarfs than that in normal trees. It can be concluded that this dwarf growth occurs as a result of extremely slow growth by environmental stress such as water deficiency.ciency.

  • PDF

A Study on Characteristic of Three-Dimensional Flow around the Artificial Upwelling Structures (인공용승구조물 주변 흐름의 3차원 특성에 관한 연구)

  • Jeon, Yong-Ho;Ryu, Cheong-Ro
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.290-293
    • /
    • 2006
  • From the hydraulic experiment, it was concluded that upwelling could be enhanced when the relative structure height (the ratio of structure height to water depth) was 0.3 and stratification parameter was 3.0. In addition, the optimum size of rubbers was determined that the effect of the mean horizontal length of block was affected incident velocity than size of block. In the numerical experiment, the relation between the shape of rubber and stratification parameter was verified, ana the hydraulic characteristics of 3-D flow field around the artificial structures were investigated. Phenomena of flow field around the artificial upwelling structures corresponded with the results of hydraulic experiment. The position with maximum velocity in artificial upwelling structure was the center of top of its front side and the slip stream occurred at the inside and behind-bottom of artificial upwelling structures. The velocity of slip stream and early amplitude of velocity were higher in the inside than the behind-bottom.

  • PDF

Velocity and Temperature Profiles of Steam-Air Mixture on the Film Condensation (막응축 열전달에서 공기-수증기 혼합기체의 속도 및 온도분포)

  • 강희찬;김무환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.10
    • /
    • pp.2675-2685
    • /
    • 1994
  • A study has been conducted to provide the experimental information for the velocity and temperature profiles of steam-air mixutre and to investigate their roles on the film condensation with wavy interface. Saturated gas mixture of steam-air was made to flow through the nearly horizontal$(4.1^{\circ})$ square duct of 0.1m width and 1.56m length at atmospheric pressure, and was condensated on the bottom cold plate. The air mass fraction in the gas mixture was changed from zero(W =0, pure steam) to one(W =1, pure air), and the bulk velocity was varied from 2 to 4 m/s. Water film was injected concurrently to investigate the effect of wavy interface on the condensation. The velocity and temperature profiles were measured by LDA system and thermocouples along the three parameters ; air mass fraction, mixture velocity and film flow rate. The profiles moved toward the interface with increasing steam mass fraction, mixture velocity and film flow rate. The Prandtl and Schmidt numbers were near one in the present experimental range, however there was no complete similarity between the velocity and temperature profiles of gas mixture. And the heat transfer characteristics and interfacial structure were coupled with each other.

The Effect of Turbulence Penetration on the Thermal Stratification Phenomenon Caused by Leaking Flow in a T-Branch of Square Cross-Section (난류침투가 사각단면 T분기관 내 누설유동에 의해 발생한 열성층 현상에 미치는 영향)

  • 홍석우;최영돈;박민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.239-245
    • /
    • 2003
  • In the nuclear power plant, emergency core coolant system (ECCS) is furnished at reactor coolant system (RCS) in order to cool down high temperature water in case of emergency. However, in this coolant system, thermal stratification phenomenon can occur due to coolant leaking in the check valve. The thermal stratification produces excessive thermal stresses at the pipe wall so as to yield thermal fatigue crack (TFC) accident. In the present study, effects of turbulence penetration on the thermal stratification into T-branches with square cross-section in the modeled ECCS are analysed numerically. $textsc{k}$-$\varepsilon$ model is employed to calculate the Reynolds stresses in momentum equations. Results show that the length and strength of thermal stratification are primarily affected by the leak flow rate of coolant and the Reynolds number of the main flow in the duct. Turbulence penetration into the T-branch of ECCS shows two counteracting effects on the thermal stratification. Heat transport by turbulence penetration from the main duct to leaking flow region may enhance thermal stratification while the turbulent diffusion may weaken it.

A Study on the Anti-Rolling Control System of Small Ship (소형선박의 횡요방지 제어장치 연구)

  • Kim, Si-Young;Yoo, Jae-Bok;Moon, Chul-Jin
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.11 no.2
    • /
    • pp.184-202
    • /
    • 1999
  • The roll damping characteristics of the three models of a small fishing(3 ton class fishing vessel), such as the bare hull, hull with bilge keels, and hull with bilge keels and a central wing are investigated by the free roll and head waves tests in calm water in a towing tank with the various forward speeds, initial angles and OG's. The experimental results are compared with the numerical results of mathematical modelings by the energy method for these three models and the energy dissipation patterns are also compared. And the wave length variations are also included. The experimental results are compared with the numerical results of mathematical modelings by the energy method for these three models and the energy dissipation patterns are also compared. The roll damping moment of the models is increased for zero speed cases, but as the speed increases, the effect of the waves on the roll damping of the models with the additional devices is negligible due to the much increased damping caused by the lift increase.

  • PDF

Development of the active magnetic regenerative refrigerator for room temperature application (상온 능동형 자기 재생 냉동기의 개발)

  • Park, I.;Kim, Y.;Jeong, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.60-64
    • /
    • 2012
  • In this paper, an investigation of a room temperature active magnetic regenerative refrigerator is carried out. Experimental apparatus includes two active magnetic regenerators containing 186 g of Gd spheres. Four E-type thermocouples are installed inside the Active magnetic regenerator(AMR) to observe the instantaneous temperature variation of AMR. Both warm and cold heat exchangers are designed for large temperature span. The cold heat exchanger, which separates the two AMRs, employs a copper tube with length of 80 mm and diameter of 6.35 mm. In order to minimize dead volume between the warm heat exchanger and AMRs, the warm heat exchangers are located close to the AMRs. The deionized water is used as a heat transfer fluid, and maximum 1.4 T magnetic field is supplied by Halbach array of permanent magnets. The AMR plate, which contains the warm and the cold heat exchangers and the AMRs, has reciprocating motion using a linear actuator and each AMR is alternatively magnetized and demagnetized by a Halbach array of permanent magnet. Since the gap of the Halbach array of permanent magnets is 25 mm and two warm heat exchangers have the motion through it, a compact printed circuit heat exchanger (PCHE) is used as a warm heat exchanger. A maximum no-load temperature span of 26.8 K and a maximum cooling power of 33 W are obtained from the fabricated Active Magnetic Regenerative Refrigerator (AMRR).

Numerical Analysis of an Air-cooled Ammonia Condenser with Plate Fins

  • Kim, Young-Il;Kang, Byung-Ha
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.104-112
    • /
    • 1998
  • Ammonia has been used as refrigerant for more than 100 years in absorption as well as in compression systems. Due to its poisonous and inflammable properties, however, its use has been mainly on heavy industrial plants in which regular maintenance is available. For these systems, condensers are generally water∼cooled. This is suitable for large systems over 20RT but is not suitable for small systems. In order to apply ammonia for a small system, it is important to adopt an air-cooled condenser. In this study, simple numerical analysis of an air-cooled condenser for an ammonia refrigeration system has been carried out. The condenser is designed as horizontal tubes with plate fins attached at the outer surface to enhance the air-side heat transfer rate. Effect of fin shape and arrangement are studied in detail. Since the local heat transfer coefficient is highest at the leading edge, heat flux is highest at the edge and decreases along the distance. Conditions of inlet air are also varied in the study and condenser length that is required for full condensation is calculated. The results show that it is important to enhance both the air-side and internal heat transfer coefficients.

  • PDF