• Title/Summary/Keyword: water length effect

Search Result 816, Processing Time 0.025 seconds

Study on Atomization Characteristics of Shear Coaxial Injectors (전단동축형 분사기들의 미립화 특성에 대한 연구)

  • Ahn, Jonghyeon;Lee, Keunseok;Ahn, Kyubok
    • Journal of ILASS-Korea
    • /
    • v.26 no.1
    • /
    • pp.9-17
    • /
    • 2021
  • Six shear coaxial injectors with different recess length and taper angle were manufactured. Cold-flow tests on the injectors were performed at room temperature and pressure using water and air as simulants. By changing the water mass flow rate and air mass flow rate, spray images were taken under single-injection and bi-injection. Breakup length and spray angle were analyzed from instantaneous and averaged spray images using image processing techniques. For all the injectors, the breakup length generally decreased as the momentum flux ratio increased at the same gas mass flow rate. The injectors with 7.5° taper angle usually had the longest breakup length and the smallest spray angle. When the taper angle was 15° or more, it hardly affected breakup length and spray angle. The recess length did not influence breakup length but its effect on spray angle depended on the taper angle.

Impact of Design Parameters on Length and Application Effect of Surface Water Heat Exchanger(SWHE) (지표수 열교환기의 용량과 적용 효과에 대한 설계 인자의 영향)

  • Sohn, Byonghu;Min, Kyong-Chon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • Commercial buildings are generally cooling-dominated and therefore reject more heat to a vertical ground heat exchanger(GHE) than they extract over the annual cycle. Shallow ponds can provide a cost-effective means to balance the thermal loads to the ground and to reduce the length of GHE. The objective of this work has been to develop a design tool for surface water heat exchanger(SWHE) submerged in shallow pond. This paper presents the analysis results of the impact of design parameters on the length of SWHE and its application effect on geothermal heat pump(GHP) system using vertical GHE. In order to analysis, We applied ${\epsilon}-NTU$ method on designing the length of SWHE. Analysis results show that the required pipe length of SWHE was decreased with the increase of approach temperature difference and with the decrease of pipe wall thickness. In addition, when the SWHE was applied to the GHP system, the temperature of vertical GHE was more stable than that of standalone GHE system.

Water Absorption Characteristics of Substrate with Physical Properties of wick in Subirrigation System Using wick (심지형 저면관수시스템의 심지의 물리적 성질에 따른 수분흡수 특성)

  • Dong Ho Jung;Jung Eek Son
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.41-42
    • /
    • 2001
  • The objectives of this study were to investigate the effect of the physical properties of wick on the water absorption of substrate. Physical properties of wick in this study were cotton composition, width and length. The water Infiltration rate through the wick was 0.24 ㎝/s at 90 -95% cotton content, which was faster than at 80-85% (0.13 cm/s) and 70-75% (0.08 cm/s). As the cotton content increased, the water absorption of substrate became greater : the amount of absorbed water was about 5-7g higher at 90-95% than at 80-85% and 70-75% at a wick width of 1 ㎝, the velocity of water absorption through the wick was fastest with 0.25 ㎝ㆍs/sup -1/. The amount of absorbed water was higher at 3 ㎝ than at 1 and 2 ㎝. However, the water absorption rate through the cross - sectional area of wick (g H₂O /㎠/hr) was higher at a wick width of 2 ㎝ than at those of 1 and 3 ㎝. The amount of absorbed water in the substrate was higher at 2 : 1 than at 1 : 1 (length in substrate : length out of substrate). Absorbed water amount was larger at 30-40% initial moisture content than any other treatment.

  • PDF

Correction in the Measurement Error of Water Depth Caused by the Effect of Seafloor Slope on Peak Timing of Airborne LiDAR Waveforms (지형 기울기에 의한 항공 수심 라이다 수심 측정 오차 보정)

  • Sim, Ki Hyeon;Woo, Jae Heun;Lee, Jae Yong;Kim, Jae Wan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.3
    • /
    • pp.191-197
    • /
    • 2017
  • Light detection and ranging (LiDAR) is one of the most efficient technologies to obtain the topographic and bathymetric map of coastal zones, superior to other technologies, such as sound navigation and ranging (SONAR) and synthetic aperture radar (SAR). However, the measurement results using LiDAR are vulnerable to environmental factors. To achieve a correspondence between the acquired LiDAR data and reality, error sources must be considered, such as the water surface slope, water turbidity, and seafloor slope. Based on the knowledge of those factors' effects, error corrections can be applied. We concentrated on the effect of the seafloor slope on LiDAR waveforms while restricting other error sources. A simulation regarding in-water beam scattering was conducted, followed by an investigation of the correlation between the seafloor slope and peak timing of return waveforms. As a result, an equation was derived to correct the depth error caused by the seafloor slope.

Analytical Study on the Performance Characteristics of an Instant Cooling Type Water Purifier with the Design Parameters of the Cooling Tank (순간냉각식 정수기 냉수조의 설계변수에 따른 성능 특성에 관한 해석적 연구)

  • Jeon, Yong-Seok;Park, Hong-Hee;Lee, Joo-Seoung;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.7
    • /
    • pp.545-552
    • /
    • 2012
  • The objective of this study is to analyze the effect on the energy consumption of an instant cooling type water purifier by the design parameters of the cooling tank. Initially, the simulation program was developed and verified. The simulation results showed that the energy consumption was reduced by replacing the shape of the cooling tank from a rectangular to a cube, increasing the evaporator length, decreasing the volume of the cooling tank, and increasing the performance of the insulator. The order of the effect magnitude on the energy consumption was as follows; volume of the cooling tank, conductivity and thickness of the insulator, shape of the cooling tank, length of the evaporator, and length of the water tube.

Synthesis of Thiol-Functionalized Ionic Liquids and Formation of Self-Assembled Monolayer on Gold Surfaces: Effects of Alkyl Group and Anion on the Surface Wettability

  • Lee, Bang-Sook;Lee, Sang-Gi
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1531-1537
    • /
    • 2004
  • Twenty four thiol-functionalized ionic liquids based on imidazolium cation, 1-(12-mercaptododecyl)-3-alkylimidazolium salts, have been synthesized, and utilized to investigate the effects of alkyl-chain length and anion on the wettability of Au surfaces on the basis of self-assembled monolayers presenting [(CnSAMIM)X], where n = 1-6, X = Br, $BF_4$, $PF_4$ and $NTf_2$. Water wettabilities of the surfaces were measured as a water contact angle by contact angle goniometry. It was found that water wettability of the Au surfaces coated with imidazolium ions was largely dependent not only on counter anions but also on the length of alkyl chains. In the case of SAMs of N-alkylimidazolium ions having short length of N-alkyl chain (C1-$C_4$), anions played great role in determining water wettability of the surfaces.

A Study on the Drag Reduction Effect and Heat Transfer Enhancement of Non ionized Surfactant and Water Mixture in a Circular Pipe Flow (비이온계 계면활성제 첨가수에 대한 관내 유동저항 감소 및 열전달 촉진에 관한 연구)

  • Kim, Myoung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.552-557
    • /
    • 2007
  • This paper has dealt with the effect of non ionized surfactant and water mixture on drag reduction and heat transfer enhancement in a circular pipe flow with experimentally. The test section was consisted of stainless steel pipe with inside diameter of 16mm. The wire coil was used to increase heat transfer in a pipe and the on ionized surfactant(Oleyl Dihydroxyethyl Amino Oxide, ODEAO) was used to reduce the drag force of water mixture with surfactant. The main parameters of this experiment were diameter and pitch of wire coil and the ratio of test section length and horizontal wire coil length. In this experiment, the acquired results were 1) Drag reduction effect existed in this ODEAO-water mixture, 2) Friction factor and heat transfer were increased with insertion the heat transfer enhancement coil, 3) With increasing of pitch ratio, heat transfer was decreased, and 4) Heat transfer was decreased by the decreasing of inserting coil diameter.

Effect of Seed Leachates of 'Vernal' Alfalfa on Inhibition of Alfalfa Germination and Root Growth

  • Chon, Sang-Uk
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.45 no.2
    • /
    • pp.134-138
    • /
    • 2000
  • Most parts of alfalfa plant have been reported to contain autotoxic substances that inhibit seed germination and early seedling growth, however, the chemical(s) is not still studied much. Effect of seed leachates of 'Vernal' alfalfa (Medicago sativa L.) was evaluated for inhibition of alfalfa germination and root growth through bioassay. Alfalfa seeds were extracted in 1 L deionized water for 1 h after soaking and the leachates caused to reduce root length of alfalfa significantly as the soaking time increased. Crude seeds at 4 g L$L^{-1}$ exudated autotoxins that reduce significantly root length by 34 % compared to the control, when the seeds soaked in deionized water for 24 h. However, the extracts did not affect final germination as well as speed of germination. Extracts from ground seeds significantly reduced speed of germination (GT 50) and root length. The results indicate that release of autotoxic substances from seeds during seed imbibition was increased with increase of soaking time and seed amount, and that autotoxicity was more occurred in ground seeds than in crude seeds.

  • PDF

Effect of leg of fillet on stress distribution in weldments of large steel water pipes (수도용 대형 강관 용접부의 응력분포에 미치는 각장(leg of fillet)의 영향)

  • 김성도;배강열;나석주
    • Journal of Welding and Joining
    • /
    • v.10 no.3
    • /
    • pp.54-62
    • /
    • 1992
  • Large steel water pipes are joined prevalently by bell and method and welded at inside and outside of lapped parts. According to the Korean Standard(KS) for fabrication of water pipes, the weldments are designed to have the length of leg which is same as or larger than the thickness of the pipe. It is recently pointed out that the standard size of weldments is too large, which results in an excessive consumption of material and labor. In this study, several cases of weldments having different sizes were investigated to reduce the length of leg to the effective size. For each case, the analysis of stresses was carried out to evaluate the safety of the welded pipes by using a package program, ANSYS, under the consideration of the loading condition of water pipes which includes the soil pressure on the pipe, the load over the road, and temperature change of the pipe. The results of this study revealed that the weldment which has the length of leg of the size over 0.7*thickness of the pipe could provide a stress level below the yield strength. Especially when the length of leg is 85% of the wall thickness, the maximum equivalent stress is only slightly higher than that of the leg of fillet of the size of 1.0*pipe thickness.

  • PDF

A Study on Accalerated Vocous Condition in Siphon Spillway (싸이폰식 여수토의 진공촉진에 대한 연구)

  • 김시원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.6 no.2
    • /
    • pp.816-825
    • /
    • 1964
  • 1. Outline: The flow of the siphon spillway is very intricate and affected by vacuous condition. It is an intresting problem to make vacuum rapidly in_siphon, i.e, to provoke the perfect siphonaoge with the lowest water-level of overflow. The hydraulic experiments of siphon spillway have practiced at the Masan Lake, Haenam, the province of Junnam and gained rational and economical results which cannot be odtained by calculation. 2. Experiment: The model scale was a half of that of the prototype. 3. Results and discussion: In the experiments of 14 runs, washing, overflow water level, outlet, water level of cushion, phenomenon of water flying and water pressure of every part, etc. were studied. a) The relation of overflow water-level at siphon inlet and deflector When the elevation of the deflector is 10. 65m and the form of deflector O.4m long is the hypotenuse of an $45^{\circ}$ isosceles triangle, the over flow water-level is the minimum, i. e. the siphonage was excellent. There is no effect by the rising of overflow water-Ievel between 11.95m to 1O.65m of deflector elevation (in the first plan, it is 11.05m). But the overflow water-level rises remarkably in the outside region of the above limits. b) The relation of overflow water-level, the length of cushion and standard height of the base. The reduction of the length of cushion brings the rising of overflow waterlevel, and the rising of the standard height of the base brings the rising of overflow water level. For the long cushion length and low standard height of the base, it cannot be expeted to have the falling of overflow water-level. The most satisfactory data were obtained at 5.20m of the base standard height and 6.1m of the length of cushion. The first vah,le planned was 5.70 m and 4.30m.

  • PDF