• Title/Summary/Keyword: water length effect

Search Result 816, Processing Time 0.03 seconds

Change of Spray Characteristics with Mixing Port Length of Y-Jet Atomizers (Y-Jet 노즐에서의 혼합관 길이변화에 따른 분무특성 연구)

  • 송시홍;이상용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.3021-3031
    • /
    • 1994
  • Experiments have been performed to find out the effect of the mixing port length of Y-jet atomizers on the spray performance, using air and water as the test fluids. Water and air flow rates and drop sizes were measured at each injection pressure condition for different mixing port length. The air flow rate was almost unaffected by the change of the mixing port length. However, the water flow rate was relatively susceptible to the change of the mixing port length. The mixing point pressure was very much influenced by the mixing port length. Variations of spatial distribution of Sauter Mean Diameter (SMD, $D_{32}$) and the cross-section-averaged SMD ($D_{32,m}$) with different mixing port length and air/water mass flow rate ratio were examined. Generally, when the mixing port length was reduced, the mean drop size decreased and became spatially even.

Analysis of Thermo Environment Change by Introduction of Indoor Water Space (실내 수공간 도입에 따른 온열 환경 변화 분석)

  • Oh, Sang Mok;Oh, Se Gyu
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.53-60
    • /
    • 2012
  • This research is an illustrative research to verify the thermo environmental change created after introduction of indoor pond through abridged model test and simulation analysis. Especially, temperature and comfort level are analyzed by adjusting factors like size of water space, distance length, and location. Summary of the research is as follows. First, the most effective size of water space is 7% of the indoor size, from southern side. Temperature reduction effect is about $1.6^{\circ}C$(5.5%), and for the comfort level, it is found that pmv index increases 8%. Second, based on the simulation of distance length with the sphere, it is more effective as it is close to the surface. If distance length is more than 0.5m, there is no effect on reduction of temperature and comfort level of indoor environment. Lastly, for the analysis by location of the introduced water space, simulation is undertaken by dividing the water space (14% of the indoor size) with front, side, rear and center types. Temperature reduction effect is found to be : front type ($-1.53^{\circ}C$), side type ($-0.82^{\circ}C$), rear type ($-0.44^{\circ}C$), center type ($-0.28^{\circ}C$), respectively. The indoor environment change data by introduction of water space, found in this research, is at initial phase, but it is deemed to be a basic data to refer when planning actual water space.

Effect of Refrigerant Pipe Length on Sea Water Cooling System Performance (해수냉각시스템 성능에 미치는 냉매배관길이의 영향)

  • Yun, Jeong-In;Jo, Yeong-Je
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.3
    • /
    • pp.346-351
    • /
    • 1998
  • The purpose of this study is analyzing the performance of sea water cooling system under various refrigerant pipe length. In sea water cooling system, the increase of refrigerant pipe length cause increases of pressure drops. These pressure drops cause fresh gas in liquid pipe and increase specific volume in gas pipe outlet, so sea water cooling system capacity is decreased by decrease of refrigerant mass flow rate. Sea water cooling system capacity in refrigerant pipe length 70m is decreased more than 30% when compared with pipe length 10m and the decrease of the coefficient of performance is nearly 20%.

  • PDF

An Experimental Study on Water-Hammer Effect for Spacecraft Propulsion System (인공위성 추진계통 관로내의 수격효과에 관한 실험적 연구)

  • Kwon, Ki-Chul;Lee, Eun-Sang;Park, Sang-Min;Kang, Shin-Jae;Rho, Byung-Joon
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.288-293
    • /
    • 2001
  • This paper presents the water-hammer effect due to the rapid opening and closing of isolation valve and thruster valve in the spacecraft propulsion system. The single propellant feed system was modeled to investigate the maximum peak pressure due to the water-hammer effect. The test parameters are tank supply pressure, shape and throat length of orifice and line length. Kerosene was used as the inert simulant propellant liquid instead of hydrazine. As downstream line length after isolation valve increased from 1.5 to 2.5m, the maximum line-filling water-hammer peak pressure decreased, but the average time interval between peak pressures increased. The maximum line-filling water-hammer peak pressure with orifice was lower than without orifice, and the maximum line-filling water-hammer peak pressure with orifice at the back of isolation valve was lower than with orifice in front of isolation valve. Without orifice, the maximum water-hammer peak pressure due to the rapid opening and closing of the thruster valve was about 126% of tank supply pressure. With orifice, it decreased. As orifice throat length increased, it decreased. The maximum water-hammer peak pressure due to the rapid closing of the thruster valve with converging-diverging orifice was lower than normal orifice. It was found that the orifice as a means of pressure drop was very effective to reduce the water hammer peak pressure at the thruster valve. The results of this study can be used for the design of spacecraft liquid propulsion feed system.

  • PDF

Effect of Electrolyzed Acidic Water on the Growth of Soybean Sprout. (산성 전해수가 콩나물의 생육에 미치는 영향)

  • 윤동준;이정동;강동진;박순기;황영현
    • Journal of Life Science
    • /
    • v.14 no.5
    • /
    • pp.809-814
    • /
    • 2004
  • To investigate the effect of the electrolyzed acidic water for soybean sprouts growth, the responses of characteristics of soybean sprouts were evaluated. Soybean sprouts grown by the electrolyzed acidic water showed shorter length in total body, root, and hypocotyl, etc. but they were evaluated to be increased in hypocotyl diameter and weight per sprout. Total length of soybean sprouts grown for 5 days by electrolyzed acidic water were much shorter than those by tap water. Soybean sprouts grown by tap water showed rapid growth in length even after 5 days but no more growth in length for those grown by electrolyzed acidic water. The growth of hypocotyl showed the same tendency as total length. No difference in root length among the soybean sprouts grown for 4 ~ 11 days by electrolyzed acidic water while those grown by tap water showed continuous rapid growth in length. The diameter of hypocotyl was thicker in those grown by electrolyzed acidic water than those grown by tap water and increased up 5 days. The weight of cotyledon grown by electrolyzed acidic water showed the proportional increase to the growing days but those grown by tap water showed no increase in hypocotyl weight up to 7 days, but a little bit increase after 11 days with the growth of new buds. The fresh weight per sprout was higher in those grown by electrolyzed acidic water until 7 days than tap water but it was the same weight in 11 days cultivation. The electrolyzed acidic water effected on shortening of hypocotyl and root length, thickening of hypocotyl diameter, and enlarging of cotyledon during soybean sprout cultivation.

Investigation of water length effects on the modal behavior of a prototype arch dam using operational and analytical modal analyses

  • Sevim, Baris;Bayraktar, Alemdar;Altunisik, Ahmet Can
    • Structural Engineering and Mechanics
    • /
    • v.37 no.6
    • /
    • pp.593-615
    • /
    • 2011
  • This study determines the water length effects on the modal behavior of a prototype arch dam using Operational and Analytical Modal Analyses. Achievement of this purpose involves construction of a prototype arch dam-reservoir-foundation model under laboratory conditions. In the model, reservoir length was taken to be as much as three times the dam height. To determine the experimental dynamic characteristics of the arch dam using Operational Modal Analysis, ambient vibration tests were implemented for empty reservoir and three different reservoir water lengths. In the ambient vibration tests, the dam was vibrated by natural excitations provided from small impact effects and the response signals were measured using sensitive accelerometers. Operational Modal Analysis software process signals collected from the ambient vibration tests, and Enhanced Frequency Domain Decomposition and Stochastic Subspace Identification techniques estimated modal parameters of the dams. To validate the experimental results, 3D finite element model of the prototype arch dam was modeled by ANSYS software for empty reservoir and three different reservoir water lengths, and dynamic characteristics of each model were determined analytically. At the end of the study, experimentally and analytically identified dynamic characteristics compared to each other. Also, changes on the natural frequencies along to water length are plotted as graphs. Results suggest that reservoir water complicates the modal behavior of the arch dam significantly.

Surface morphology modification of vertically-aligned carbon nanotubes by water vapor exposure

  • Adil, Hawsawi;Jeong, Goo-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.238.2-238.2
    • /
    • 2015
  • Surface modification of vertically-aligned carbon nanotube (VACNT) is essential in order to meet specific demands for particular applications such as field emission displays, heat dissipation device and potential sun energy conversion due to their superior electrical and thermal conductivity and strong light absorption. In this study, we observe the effect of exposure to water vapor on a different lengths of the surfaces of VACNT. The study was conducted on three different lengths of the VACNT: short length around $200{\mu}m$, medium-length around $500{\mu}m$, and high length around 1 mm. Water exposure time ranges between 2-10 min and temperature of the water ranges from 60 to 120 oC. The result of water vapor exposure mainly show that increasing the exposure time and water temperature give rise to increase of the speed of change on the surface of the VACNT. Especially, the shorter VACNT change their surface morphology most rapidly.

  • PDF

Water Tree Characteristics of XLPE/EnBA Blends as a function of Crosslinking Coagent Contents (XLPE/EnBA에서의 가교조제에 따른 수트리 특성)

  • 오우정;서광석;김종은
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.219-222
    • /
    • 1998
  • In this study, The water tree characteristics were investigated when crosslinking coagent was added in XLPE/EnBA blends. When XLPE was blended with EnBA, there was a decrease of water tree length as an increase of nBA contents in XLPE/EnBA20 blends. The effect of crosslinking coagent. A was better than those of other crosslinking coagents B, C and D in water tree retardation. In case of XLPE/EnBA/Crosslinking coagent blends, water tree length was increased as the crosslinking coagents were increased from 0.2 to 2 phr in 2.0 phr DCP content. To clarify the effects of crosslinking coagent, the DCP contents were changed from 1.5 to 2.0 par in the same crosslinking coagent contents. Then, there was a decrease of water tree length as an increase of crosslinking coagent contents in 1.5 and 1.8 phr DCP contents.

  • PDF

Determine the Length of the Side-Weir of Side-Weir Detention Basin Considering the Uncertainty of the Water Level in River (하천 수위 예측의 불확실성을 고려한 강변저류지 횡월류부 길이 결정 기법)

  • Kim, Seojun;Kim, Sanghyuk;Yoon, Byungman
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.8
    • /
    • pp.673-683
    • /
    • 2015
  • The existing flood protection in rivers has shown the limitation due to the urbanization around rivers and the abnormal climate. Thus, the demand for the constructions of side-weir detention basin are being increased as a part of integrated watershed flood protection plan. It is necessary to estimate the quantitative flood-control effect for including the side-weir detention basin in flood-control measures. For the determination, it is required to reduce the uncertainty of the design factors which can affect the flood-control effect of side-weir detention basin. Among the factors, however, the water level in river always contains uncertainty. Therefore, the design method considering the uncertainty is required. For the reasons, the design method considering uncertainty of the water level in river is suggested in this study with using the length of side-weir which is relatively easy-determinable by designers. Therefore, it is examined how the variation of the length of side-weir can affect the flood-control effect, using HEC-RAS, and then the method to determine the side-weir length considering the uncertainty of the water level in river through results from analyses. Since the uncertainty of the water level in river can be taken into account in the suggested design method, it is evaluated that the design method is more effective to suggest the flood-control effect of the side-weir type detention basin with higher safety side.

Effect of Water Flux on the Determination of Membrane Permeability Using Single-pass Perfusion

  • Oh, Doo-Man
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.19-25
    • /
    • 1994
  • The single-pass perfusion technique was employed in order to investigate the effect of water flux from the rat jejunum in the normal experimental conditions. Our results suggested that water flux below ${\pm}0.75%/cm$ of jejunal length was considered normal. Water flux was $-0.131\;{\pm}\;0.311%/cm$ of jejunal length in a citrate buffer and should be corrected in order to determine the permeabilities of the compounds. Perfusion rate up to 0.5 ml/min had no effects on the permeability of ampicillin. Neither the effective permeabilities nor the wall permeabilities of aminopenicillins were influenced by water flux during experiments in rats.

  • PDF