• 제목/요약/키워드: water leak test

검색결과 60건 처리시간 0.029초

칼리머 증기발생기에서 물-소듐 반응에 의한 소음 발생과 수소 기포의 소음 흡수 (Noise Generation by Water-Sodium Reaction and its Absorption on Hydrogen Bubbles for KALIMER Steam Generator)

  • 김태준;;황성태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1829-1835
    • /
    • 2000
  • The experimental results of sodium-water reaction noise measurement in frequency range $1{/sim}200kHz$ are presented. The experiments of noise generation under the condition of sodium test facility, water leak rate $0.01{\sim}1.2g/s$ and temperature of sodium $250{\sim}500^{\circ}C$, were carried out. From theoretical study it is noted that the noise resonant attenuation on hydrogen bubbles in liquid sodium plays the significant role for leak noise spectra formation. Interaction of leak noise and hydrogen bubbles in sodium being accompanied by thermal, emission and viscosity energy dissipation was studied. Acoustic noise spectra were investigated from point of view of water leak detection in sodium/water steam generator. The results of sodium-water reaction noise absorption on hydrogen bubbles in liquid sodium by temperature $250{\sim}500^{\circ}C$ are presented. The theoretical model of noise absorption using the coefficients of attenuation was developed. From calculation the coefficients of attenuation were estimated.

  • PDF

관거 및 지하구조물 균열 보수에 사용되는 아크릴 누수 보수재의 적용성에 대한 연구 (A Study on the Applicability of Acrylic Water Leak Repair Materials used to Repair Cracks in Conduits and Underground Structures)

  • 이은미;길경익
    • 한국습지학회지
    • /
    • 제26권2호
    • /
    • pp.139-146
    • /
    • 2024
  • 노후된 관거 및 지하구조물의 균열 보수에 아스팔트계 주입재, 우레탄계 주입재, 시멘트계 주입재, 아크릴계 주입재 등 다양한 주입재가 사용되고 있다. 친환경적이고 습윤상태에서 경화가 잘되고 온도변화에 안정적인 물성을 갖는 아크릴계 누수 보수재에 대하여 연구하였다. 개량된 아크릴 누수 보수재와 기존 아크릴레이트 주입재의 성능 비교를 위하여 KS 규격의 실험방법에 준용하여 수중침지 길이변화율 시험, 수중 유실 저항성 시험, 내화학 성능시험을 실시하였다. 비교 실험해 본 결과 개량된 아크릴 누수 보수재는 기존 아크릴레이트 주입재보다 습윤상태, 온도변화, 화학적 반응에 따른 수축변화가 없었고 수중 저항성 실험에서 유실되지 않았다. 또한, 개량된 아크릴 누수 보수재의 환경적 영향성을 알아보기 위해 어류급성독성 실험과 급성경구독성 실험을 진행하여 관찰해 본 결과 실험체의 사망률이 없었고 특별한 유의점이 발견되지 않았다. 본 연구의 실험결과 개량된 아크릴 누수 보수재가 성능적으로 우수하고 환경적으로 안전하고 인체에 무해하다고 판단되었다. 본 연구의 다양한 실험결과 기존의 아크릴레이트 보수재보다 개량된 아크릴 누수 보수재가 관거 및 지하구조물 균열 부위의 보수재로 사용되기 적합하다고 사료된다. 본 연구는 아크릴 누수 보수재에 대한 적용성 평가에 대한 연구로 향후 기술 개발에 활용자료로 제안하고자 한다.

상수도용 Pipeline의 누수고장 자료 분석 (Data Analysis of First Leak Time of Water Pipeline)

  • 나명환;함상민
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제11권3호
    • /
    • pp.213-224
    • /
    • 2011
  • In this paper, we analyze statistically the data set of first leak time of water pipeline. We classify first the leak time data by pipe type, location, diameter of pipe and, length of pipe. We perform the analysis of variance to indicate that there are significant difference of mean of the time between levels of the factor and also compare the distribution of levels using the multiple box-plot. When there are the difference of the mean, we perform the least significant test to find out what levels of the facor has a different mean.

동절기 수압시험을 대체하는 공기압시험의 적정압력 비교분석에 관한 연구 (Winter to replace the hydraulic test and pneumatic test comparative analysis of study on the optimal pressure)

  • 권영희;황동환;김태길;강경식
    • 대한안전경영과학회지
    • /
    • 제16권2호
    • /
    • pp.211-216
    • /
    • 2014
  • Using a high-rise building water piping after hydrostatic test of the reliability of the leak to be completed if the pressure is maintained until the leak is not commercially available considered. Due to the nature of high-rise buildings and the construction period will take several years from the lower levels of use of the water supply and fire fighting water pipe construction is in progress, the order of which I do most of the first pipe to the construction and more than three years. So kind of riser pipe is complete, install the valve in the basement by installing an automatic pump to maintain a constant pressure after hydrostatic test and after each floor plumbing piping is complete, the progress of the hydrostatic test without undergoing a separate branch pipe the valve is opened automatically when the number of the pressing pressure of the structure. I kind of do and keep working pressure of pipe until the completion of the construction work to keep the damage to human error when it is intended to prepare. In winter, the frost protection and an alternative to drainage water pipe is damaged or deformed, even if unaware of the finishing work to the building, the use of the damage caused by a leak in a after construction of finish work to be expected. Alternative to reduce this damage if the pressure test without fear of freezing to help maintain long-term commercial pressures may be considered.

Burst Behavior for Mechanically Machined Axial Flaws of Steam Generator Tubings

  • Hwang, Seong Sik;Kim, Hong Pyo;Kim, Joung Soo
    • Corrosion Science and Technology
    • /
    • 제3권1호
    • /
    • pp.30-33
    • /
    • 2004
  • It has been reported that some events of a rupture of seam generator tube have occurred in nuclear power plants around the world. Main causes of the leakage are from various types of corrosion in the steam generator(SG) tubings. Primary water stress corrosion cracking(PWSCC) of steam generator tubings have occurred in many tubes in Korean plant, and they were repaired using sleeves or plugs, In order to develop proper repair criteria, it is necessary to ascertain the leak behavior of the tubings. A high pressure leak and burst testing system was manufactured. Various types of Electro Discharged Machined (EDM) notches were developed on the SG tubes. Leak rate and burst pressure were measured on the tubes at room temperature. Burst pressure of the part through wall defected tubes depends on the defect depth, Water flow rates after the burst were independent of the t1aw types; tubes having 20 to 60 mm long EDM notches showed similar flow rates regardless of the defect depth. A fast pressurization rate gave the tube a lower burst pressure than the case of a slow pressurization.

발전기 고정자 권선의 흡습 진단 (A Study on the Diagnosis for Water Absorption of Generator Stator Windings)

  • 배용채;김희수;이두영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.297-298
    • /
    • 2006
  • Water leak for the water-cooled generator stator windings affects seriously the availability and the reliability of power plants. Generally, water absorption test is conducted in the power plant during outage in order to confirm if leak part is in the bars or not. In this paper, it is described that the capacitance of winding bars is measured by using the developed water absorption instrument system and the water absorption of winding bars is evaluated by using the stochastic methods. The good results by proposed diagnosis technique can be got. It is expected that the reliability of diagnosis for water absorption is increased if the proposed methods are applied to evaluate the water absorption of stator winding bars.

  • PDF

여러 가지 확률분포를 이용한 발전기 고정자 권선의 흡습 시험에 관한 연구 (A Study on the Water Absorption Test of Generator Stator Windings Using Probability Distributions)

  • 김희수;배용채;김희정;나명환
    • 응용통계연구
    • /
    • 제22권5호
    • /
    • pp.961-969
    • /
    • 2009
  • 발전기 고정자 권선의 냉각수 누수는 발전기 운전 중 절연 파괴를 발생시켜 발전소 불시정지를 발생시킬 뿐만 아니라 권선 손상에 따른 정비 기간 및 비용이 매우 많이 소요된다. 따라서 발전기 고정자 권선의 냉각수 누수가 발생하였을 때 재앙이 일어나기 전에 고정자 권선 절연물의 흡습 상태를 진단하는 것은 예방 정비 측면에서 매우 효과적인 정비 방안이라고 할 수 있겠다. 본 논문에서는 발전기 고정자 권선에 흡습여부를 알아보기 위하여 여러 가지 확률분포를 이용하여 판정기준값을 유도하였다. 또한, 유도된 판정기준값을 바탕으로 실제 관측된 자료를 이용하여 흡습여부를 판단하였다.

Modeling of Hydrodynamic Processes at a Large Leak of Water into Sodium in the Fast Reactor Coolant Circuit

  • Perevoznikov, Sergey;Shvetsov, Yuriy;Kamayev, Aleksey;Pakhomov, Ilia;Borisov, Viacheslav;Pazin, Gennadiy;Mirzeabasov, Oleg;Korzun, Olga
    • Nuclear Engineering and Technology
    • /
    • 제48권5호
    • /
    • pp.1162-1173
    • /
    • 2016
  • In this paper, we describe a physicomathematical model of the processes that occur in a sodium circuit with a variable flow cross-section in the case of a water leak into sodium. The application area for this technique includes the possibility of analyzing consequences of this leak as applied to sodium-water steam generators in fast neutron reactors. Hydrodynamic processes that occur in sodium circuits in the event of a water leak are described within the framework of a one-dimensional thermally nonequilibrium three-component gas-liquid flow model (sodium-hydrogen-sodium hydroxide). Consideration is given to the results of a mathematical modeling of experiments involving steam injection into the sodium loop of a circulation test facility. That was done by means of the computer code in which the proposed model had been implemented.