• Title/Summary/Keyword: water flow rate

Search Result 3,046, Processing Time 0.03 seconds

Analysis on the Bluegill Blocking Effects using Bubbles (버블을 이용한 파랑볼우럭 차단 효과 분석)

  • Kang, Joon-Gu;Kim, Jong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.390-397
    • /
    • 2017
  • The introduction of exotic fish species may reduce the number of native fish species and disturb the aquatic ecosystem. Therefore, measures to block and manage fish species are required. Accordingly, a fish species blocking system using bubbles was developed in this study to block exotic fish species. An experimental channel was produced and the possibility of blocking such exotic fish species was evaluated. The bubble generator is a system that produces a bubble curtain by generating air with an air compressor that blocks fish species. Bluegill, which is an exotic fish species in the country, was tested with this generator. The size of bluegill was between 0.10 m and 0.15 m and the depth of water was maintained at 0.70 m. The flow velocity of the experiment channel was classified into 3 levels (0.20 m/s, 0.10 m/s, and 0.05 m/s) considering the natatorial ability of the fish species. The results revealed that 70.07% of bluegill showed movements to swim upstream before applying the bubble, but it is considered that the ascending rate would be higher given that the fish species thinks downstream is a habitat and showed almost no movement. However, when the blocking facility was installed, most fish species showed movements to return to the downstream again by the bubble curtain, indicating a very high blocking effect. In particular, when the generating bubble was terminated, the fish species swam back to the upstream area very soon, so the fish species blocking effect using the bubble was excellent.

The Effect of Stress on SCC of Heat Exchanger Tube for LNG Vessel (LNG선박용 열교환기 세관의 SCC에 미치는 응력의 영향)

  • Jeong Hae Kyoo;Lim Uh Joh
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.2 s.19
    • /
    • pp.22-32
    • /
    • 2003
  • Al-brass material is generally used at the state of plastic deformation, for example; bending, extension of bell mouth at shell and tube type heat exchanger. And SCC(stress corrosion cracking) of Al-brass material will be affected by residual stress as plastic deformation. SCC results from synergism between mechanical factor and corrosion environment. Mechanical factor is stress that directly relates with stress intensity factor at the crack tip. This paper was studied on the effect of stress on SCC of Al-brass tube under in $3.5\%$ NaCl. + $0.1\%\;NH_4OH$ solution by constant displacement tester. Increasing of acidified water flow into sea and speeds up corrosion rate of Al-brass which is used as a tube material of vessel heat exchanger by polluted coast seawater. The experimental results are as follow The latent time of SCC occurrence gets longer as the initial stress intensity factor($K_{Ii}$) gets lower The main crack was propagated as the initial stress intensity factor($K_{Ii}$) gets higher, and secondary cracks occurred by electro-chemical factor a(ter stage of released stress. Dezincification phase showed around the crack, and the range of dezincification gets wider as the initial stress intensity factor($K_{Ii}$) gets higher.

  • PDF

Surface Modification of Polytetrafluoroethylene by Using Low Energy Hydrogen Ion Beam (저에너지 수소 이온빔을 이용한 polytetrafluoroethylene 표면 개질)

  • Lee, Jung-Hwan;Kim, Dong-Hwan;Yeo, Woon-Jung;Han, Young-Gun;Cho, Jun-Sik;Kim, Hyun-Joo;Koh, Seok-Jeun
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.612-618
    • /
    • 2006
  • Surface modification of PTFE by ion irradiation was performed to improve its surface properties, In the case where argon was used to irradiate the PTFE films, an increase in the adhesion strength was observed when the ion fluence was over $1\times10^{15}\;ions/cm^2$, but the surface morphology dramatically changed to a needle-shaped one. However, when we used hydrogen ions under $O_2$ environmental gas, the adhesion strength increased at an ion fluence of $5\times10^{16}\;ions/cm^2$ and the surface morphology by the hydrogen irradiation was not needle-shaped. The surface morphology and adhesion strength of the hydrogen modified PTFE was influenced by the oxygen flow rate. It was confirmed by reflectance measurements that the surface properties of the hydrogen ion irradiated PTFE were superior to those of the argon ion irradiated PTFE.

Review on Coastline Change and Its Response Along the Cotonou Coast, Benin in the Gulf of Guinea, West Africa (서아프리카 기니만에 있는 베냉 코토누의 해안선 변화와 대응에 대한 고찰)

  • Yang, Chan-Su;Hong, Hyeyeon;Shin, Dae-Woon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.691-699
    • /
    • 2021
  • The global surface temperature has risen critically over the past century and according to the IPCC Fifth Assessment Report 2014, existing risks in natural and human systems will worsen. Coastal erosion is mostly caused by climate change and among all the coastal areas at risk, Benin, which is part of the Gulf of Guinea, has been ranked very highly as a vulnerable region. Therefore, in this review, we focus on the evolution of coastline change in Cotonou of Benin, summarizing its resultant impacts and applied measures around the coast area by reviewing previous studies. Signs of coastal erosion in Cotonou appeared in 1963. After 39 years, the east shoreline of Cotonou has retreated by 885 m, resulting in the disappearance of more than 800 houses. To solve this problem, Benin authorities built seven groynes in 2013, and have increased the number of the structure as a way to interrupt water flow and limit the movement of sediment. Over the region, shorelines appeared preserved accordingly. In contrast, areas located further east, where groynes were not installed, have suf ered from intensive erosion at a rate of 49 m/yr. In the future, as a next step, the effectiveness of groynes should be studied with local and broader perspectives.

Development and Validation of Analytical Method for Decursin in Aerial Parts of Angelica gigas Nakai Extract (참당귀 지상부 추출물의 지표성분 decursin의 분석법 개발 및 검증)

  • Kim, Hee-Yeon;Lee, Ki-Yeon;Kim, Tae-Hee;Park, A-Reum;Noh, Hee-Sun;Kim, Si-Chang;Ahn, Mun-Seob
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.52-57
    • /
    • 2019
  • Method development and validation of decursin for the standardization of Angelica gigas Nakai as a functional ingredient and health food were accomplished. The quantitative determination method of decursin as a marker compound of aerial parts of Angelica gigas Nakai extract (AAGE) was optimized by HPLC analysis using a C18 column ($3{\times}150mm$, $3{\mu}m$) with 0.1% TFA in water and acetonitrile as the mobile phase at a flow rate of 0.5 mL/min and detection wavelength of 330 nm. The HPLC/PDA method was applied successfully to quantification of the marker compound in AAGE after validation of the method with linearity, accuracy, and precision. The method showed high linearity in the calibration curve at a coefficient of correlation ($R^2$) of 0.9994 and the limit of detection and limit of quantitation were $0.011{\mu}g/mL$ and $0.033{\mu}g/mL$, respectively. Relative standard deviation (RSD) values of data from intra- and inter-day precision were less than 1.10% and 1.13%, respectively. Recovery of decursin at 0.5, 1, 5 and $10{\mu}g/mL$ were 92.38 ~ 104.11%. These results suggest that the developed HPLC method is very useful for the determination of marker compound in AAGE to develop a health functional material.

Development and validation of an LC-MS/MS method for the simultaneous analysis of 26 anti-diabetic drugs in adulterated dietary supplements and its application to a forensic sample

  • Kim, Nam Sook;Yoo, Geum Joo;Kim, Kyu Yeon;Lee, Ji Hyun;Park, Sung-Kwan;Baek, Sun Young;Kang, Hoil
    • Analytical Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.35-47
    • /
    • 2019
  • In this study, high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was employed to detect 26 antidiabetic compounds in adulterated dietary supplements using a simple, selective method. The work presented herein may help prevent incidents related to food adulteration and restrict the illegal food market. The best separation was obtained on a Shiseido Capcell Pak(R) C18 MG-II ($2.0mm{\times}100mm$, $3{\mu}m$), which improved the peak shape and MS detection sensitivity of the target compounds. A gradient elution system composed of 0.1 % (v/v) formic acid in distilled water and methanol at a flow rate of 0.3 mL/min for 18 min was utilized. A triple quadrupole mass spectrometer with an electrospray ionization source operated in the positive or negative mode was employed as the detector. The developed method was validated as follows: specificity was confirmed in the multiple reaction monitoring mode using the precursor and product ion pairs. For solid samples, LOD ranged from 0.16 to 20.00 ng/mL and LOQ ranged from 0.50 to 60.00 ng/mL, and for liquid samples, LOD ranged from 0.16 to 20.00 ng/mL and LOQ ranged from 0.50 to 60.00 ng/mL. Satisfactory linearity was obtained from calibration curves, with $R^2$ > 0.99. Both intra and inter-day precision were less than 13.19 %. Accuracies ranged from 80.69 to 118.81 % (intra/inter-day), with a stability of less than 14.88 %. Mean recovery was found to be 80.6-119.0 % and less than 13.4 % RSD. Using the validated method, glibenclamide and pioglitazone were simultaneously determined in one capsule at concentrations of 1.52 and 0.53 mg (per capsule), respectively.

A Study on the Optimal Operating Conditions for an Unreacted Hydrogen Oxidation-Heat Recovery System for the Safety of the Hydrogen Utilization Process (수소 활용공정 안전성 확보를 위한 미반응 수소 산화-열 회수 시스템의 운전 조건 최적화 연구)

  • Younghee Jang;Sung Su Kim
    • Applied Chemistry for Engineering
    • /
    • v.34 no.3
    • /
    • pp.307-312
    • /
    • 2023
  • In this study, a catalytic oxidation-heat recovery system was designed that can remove unreacted with a concentration of about 1% to 6% in the exhaust gas of hydrogen fuel cells and recover heat to ensure safety in the hydrogen economy. The safety system was devised by filling hydrogen oxidation catalysts at room temperature that can remove unreacted hydrogen without any energy source, and an exhaust-heat recovery device was integrated to efficiently recover the heat released from the oxidation reaction. Through CFD analysis, variations in pressure and fluid within the system were shown depending on the filling conditions of the hydrogen oxidation system. In addition, it was found that waste heat could be recovered by optimizing the temperature of the exhaust gas, flow rate, and pressure conditions within the heat recovery system and securing hot water above 40 ℃ by utilizing the exhaust gas oxidation heat source above 300 ℃. Through this study, it was possible to confirm the potential of utilizing hydrogen processes, which are applied in small to medium-sized systems such as hydrogen fuel cells, as a safety system by evaluating them at a pilot scale. Additionally, it could be a safety guideline for responding to unexpected hydrogen safety accidents through further pilot-scale studies.

Estimation of Pollutant EMCs and Loadings in Highway Runoff (국내 고속도로 강우 유출수의 EMCs 및 유출 부하량 산정)

  • Kim, Lee-Hyung;Ko, Seok-Oh;Lee, Byung-Sik;Kim, Sunggil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2B
    • /
    • pp.225-231
    • /
    • 2006
  • The nonpoint source control is based on TPLMS (Total Pollution Load Management System) program. Recently, the Ministry of Environment in Korea has programed TPLMS for 4 major large rivers to improve the water quality in rivers by controling the total pollutant loadings from the watershed area. Usually the urbanization is the main pollutant sources, particularly for nonpoint pollutants, because of high imperviousness and high pollutant mass emissions. The stormwater runoff from urban areas is containing various pollutants such as sediments, metals and toxic chemicals due to human and vehicle activities. Of the various landuses, the highways are highly polluted landuses because of high pollutant accumulation rate by vehicle activities during dry periods. Therefore, this research is achieved to provide pollutant EMCs (Event Mean Concentrations) and mass loadings washed-off from highways during rainfall periods. Five monitoring locations were equipped with an automatic rainfall gage and an flow meter. The results show that the EMC ranges for 95% confidence intervals in highway land use are 45.52-125.76 mg/L for TSS, 52.04-95.48 mg/L for COD, 1.77-4.48 mg/L for TN, 0.29-0.54 mg/L for TP. The ranges of washed- off mass loading are $712.7-2,418.4mg/m^2$ for TSS and $684.1-1,779.6mg/m^2$ for COD.

A Feasibility Study on GMC (Geo-Multicell-Composite) of the Leachate Collection System in Landfill (폐기물 매립시설의 배수층 및 보호층으로서의 Geo-Multicell-Composite(GMC)의 적합성에 관한 연구)

  • Jung, Sung-Hoon;Oh, Seungjin;Oh, Minah;Kim, Joonha;Lee, Jai-Young
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.4
    • /
    • pp.67-76
    • /
    • 2013
  • Landfill require special care due to the dangers of nearby surface water and underground water pollution caused by leakage of leachate. The leachate does not leak due to the installation of the geomembrane but sharp wastes or landfill equipment can damage the geomembrane and therefore a means of protecting the geomembrane is required. In Korea, in accordance with the waste control act being modified in 1999, protecting the geosynthetics liner on top of the slope of landfill and installing a drainage layer to fluently drain leachate became mandatory, and technologies are being researched to both protect the geomembrane and quickly drain leachate simultaneously. Therefore, this research has its purpose in studying the drainage functions of leachate and protection functions of the geomembrane in order to examine the application possibilities of Geo-Multicell-Composite (GMC) as a Leachate Collection Removal and Protection System (LCRPs) at the slope on top of the geomembrane of landfill by observing methods of inserting filler with high-quality water permeability at the drainage net. GMC's horizontal permeability coefficient is $8.0{\times}10^{-4}m^2/s$ to legal standards satisfeid. Also crash gravel used as filler respected by vertical permeability is 5.0 cm/s, embroidering puncture strength 140.2 kgf. A result of storm drain using artificial rain in GMC model facility, maxinum flow rate of 1,120 L/hr even spray without surface runoff was about 92~97% penetration. Further study, instead of crash gravel used as a filler, such as using recycled aggregate utilization increases and the resulting construction cost is expected to savings.

A Study on the Environmental Characteristics of a Two-storey Pig House for the Control of Manure (고상식돈사의 분뇨처리에 관한 연구)

  • Jeong, J.W.;Yoo, Y.H.;Park, K.H.;Kam, D.H.;Lee, M.J.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.3
    • /
    • pp.175-182
    • /
    • 2008
  • This research was conducted to examine proper manure treatment methods for a high-rise swine barn with results of the fact-finding survey on manure treatment methods used in high-rise swine barns and sawdust swine barns In Korea. The average temperatures on bedding of control, T1, and T2 were between $25.3{\sim}25.4^{\circ}C$ with little difference. Air flow rate of T2 was slower than those of control and T1. Dust generation in control was 54 cpm which was higher than T1 and T2. The average ammonia concentration in control was highest showing 6.0 ppm, ranged from 0.5 to 14.5 ppm, with statistical difference (p<0.05), compared to T1 (2.8 ppm) and T2 (2.6 ppm). Sawdust spreading used in control and T1 decreased ammonia concentration. T1 showed the lowest concentration of $CO_2$. Water contents of control and T2 were close to the proper water content, 65%. T1 had the highest water content and pH, and the lowest organic matter and C/N ratio. The volumes of sawdust spread per head were 0.26 and $0.27m^3$ in control and T2, respectively, which was less than T1. Operating cost such as an electricity bill for blowers was cheap in T2. Hence, T2 bedding sawdust up to 10 cm thick and periodically spreading additional sawdust from second story was recommended.

  • PDF