• Title/Summary/Keyword: water corrosion

Search Result 1,466, Processing Time 0.032 seconds

Prevention of Soil Contamination from Underground Storage Facilities (유류저장시설로 인한 토양오염 예방대책)

  • 배우근;홍종철;정진욱;강우재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.169-173
    • /
    • 1998
  • The practice of the construction and management of the underground petroleum storage facilities in Korea was investigated extensively, and the problems were identified. The advanced technologies in the U.S.A was comparatively studied. Considering the effectiveness of leak prevention and technology applicability, the following measures were suggested. To prevent corrosion of the tank, a clad tank, an interior-lining tank, or a double-wall tank was appropriate and appeared to be most cost effective. For piping, non-metalic material was suggested. To prevent spill, a catchment basin can be effective. For monitoring of leak, construction of more than one of one or combination of an automatic leak-detection device, a vapor-detection system, a ground water-monitoring system, and a double-wall detection system was recommended.

  • PDF

Characteristics of MR Polishing using Carbonyl Iron Particles Coated with Xanthan Gum (Xanthan Gum으로 코팅된 Carbonyl Iron Particle를 이용한 자기유변유체 연마특성에 관한 연구)

  • Lee, J.W.;Ha, S.J.;Shin, B.C.;Kim, D.W.;Cho, M.W.;Choi, H.J.
    • Transactions of Materials Processing
    • /
    • v.21 no.2
    • /
    • pp.138-143
    • /
    • 2012
  • A polishing method using magnetorheological (MR) fluid has been developed as a new precision technique to obtain a fine surface. The process uses a MR fluid that consists of magnetic carbonyl iron (CI) particles, nonmagnetic polishing abrasives, water and stabilizers. But the CI particles in MR fluids cause a severe corrosion problem. When coated with Xanthan gum, the CI particles showed long-term stability in corrosive aqueous environment. The surface roughness obtained from the MR polishing process was evaluated. A series of experiments were performed on fused silica glass using prepared slurries and various process conditions, including different polishing times. Outstanding surface roughness of Ra=2.27nm was obtained on the fused silica glass. The present polishing method could be used to produce ultra-precision micro parts.

Effect of Concrete Coating Materials for the Improvement of Concrete Durability (콘크리트 표면도장에 의한 내구성증진 효과)

  • 문한영;김성수;안태송;김홍삼
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.433-436
    • /
    • 1999
  • Long-term durability of the reinforced concrete structures exposed to marine environment deteriorates seriously by the attack of the chloride ion from see water results in corrosion of steel reinforcement in concrete. Their coating effect is aluminum oxide-isocyanate-based coating material, resistance of chloride penetration, carbonation and freezing and thawing resistance were compared to acryl-based coating material and sealer type o waterproofing material. Aluminum oxide-isocyante-based and acryl-based coating material show higher resistance to chloride penetration and carbonation than the sealer type do waterproofing material and aluminum oxide-isocyanate-based coating resist about 99% of chloride penetration. Resultants to the accelerated test for freezing and thawing, coating concrete show higher resistance than non-coating concrete, respectively.

  • PDF

An Experimental Study on the Fundamental Properties of. Sewage Concrete Covered with Inorganic and Complex Antibiotics (무기계 항균제 및 유$\cdot$무기계 복합 항균제를 도포한 하수시설 콘크리트의 기초물성에 관한 실험적 연구)

  • Lee Eui-Bae;Lee Dong Heck;Na Chul Sung;Khil Bae Su;Kim Gyu Yong;Kim Moo Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.499-502
    • /
    • 2005
  • Recently sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biodeterioration originated from sulfur-oxidizing bacteria. In this study, to prevent biochemical corrosion of the sewer concrete, antibiotics which prevent growth of sulfur-oxidizing bacteria were developed and antimicrobial performance of it was investigated. After that, to consider applicability of antibiotics to concrete, physical properties such as bond strength, resistance to abraision, water absorption and air permeability of concrete covered with inorganic and complex antibiotics were investigated.

  • PDF

An Experimental Study on the Salt Resistance Properties with Concrete Materials under Marine Environment (Exposure period : 5 years) (해양환경에 폭로한 콘크리트의 내염특성에 대한 실험적 연구 (폭로기간 : 5년))

  • Kim, Yong-Chul;Suk, Jun-Yeoll;Shin, Do-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.169-172
    • /
    • 2006
  • The IIA structures exposed to marine environment is subject to many different types of potential attack. The physical attack due to drying and wetting would increase the internal stress of concrete. The chemical attack resulting from the diffusion of ions$(Cl^-,SO_4^{2-},Mg^+)$ from seawater through the pores in concrete. Therefore the sea water resistance of concrete must be considered when it is used for structure in the ocean. The objective of this study is to evaluate chloride diffusion and corrosion characteristics of concrete when using the various concrete materials under marine environment. After 5 years of exposure, concrete incorporating 40% blast-furnace slag as replacement for type I cement with low w/c ratio of 0.42 and using the inhibitor shows excellent performance.

  • PDF

A Study on the Subcritical Crack Growth and the Life Prediction for Sintered Silicon Carbide (소결탄화규소의 완속균열성장 및 수명예측에 관한 연구)

  • 한원식;김영욱;이상호;장감용;이준근
    • Journal of the Korean Ceramic Society
    • /
    • v.22 no.4
    • /
    • pp.26-32
    • /
    • 1985
  • The subcritical crack growth of sintered SiC is investigated under various corrosive atmospheres such as distilled water Murakami solution and saturated KOH solution. The KI-V diagrams are obtained by the load relaxation method and incremental displacement rate method using the double torsion technique. The obtained fracture mechanics parameters (n) of sintered SiC are 79 in Murakami solution and 39 in saturated KOH solution. These data indicate that the subcritical crack growth of sintered SiC is taking place in these two conditions and the stress-corrosion cracking is suggested to be the mechanism. With these KI-V diagrams the life of sintered SiC in these conditions is predicted.

  • PDF

Effect of Mineral Admixture on Coefficient of Chloride Diffusion in Concrete (광물질 혼화재가 콘크리트의 염화물 확산계수에 미치는 영향)

  • 김명유;양은익;민석홍;심상배;최중철;이광교
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.281-284
    • /
    • 2003
  • When concrete structures are exposed under marine condition for a long time, the steel in concrete is corroded due to the ingression of chlorides in the sea water. Because the damages of corrosion resulting from the chloride ion are very serious, many research have been performed. In this study, it was experimentally investigated that the mechanical and diffusion characteristics of concrete substituted with ordinary portland cement, silica fume and blast furnace slag to investigate the chloride ingress characteristics with concrete quality. Chloride diffusion coefficients in concrete shows increasing tendency as w/c ratio increase. Also test results indicate that blend of admixture become lower chloride diffusion coefficients in concrete as compared with normal concrete.

  • PDF

The Effect of Drawing Conditions on the Tensile Strength of Optical Fiber (광섬유의 인장강도에 미치는 Drawing Condition의 영향)

  • 한택상;최상삼
    • Journal of the Korean Ceramic Society
    • /
    • v.19 no.1
    • /
    • pp.44-50
    • /
    • 1982
  • Drawing optical fibers in a graphite furnace is one of the most convenient and economical means of producing optical fiber. Since the flaw formation on optical fiber is mainly due to dust contaminations during drawing and surface corrosion by water vapor penetration through coating layer, the tensile strength of optical fiber drawn in a graphite furnace is greatly inflenced by the drawing conditions. The important factors found in this investigation were preform treatment (fire polishing), furnace interior environment (dust contamination, inert gas flows), primary coating condition (resin curing temperature, coating materials, method, thickness) and fiber pulling condition (furnace temperature, drawing speed, pulling tension). The tensile strength at optimum drawing conditions turned out to be 5 ~ 6 GPa.

  • PDF

Investigation on optimum protection potential of Al-Mg alloy for small ship application in sea water solution (소형선박용 Al-Mg 합금의 해양환경 중 최적 방식 전위결정에 관한 연구)

  • Kim, Seong-Jong;Jang, Seok-Ki;Kim, Jeong-Il;Ko, Jae-Yong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.23-24
    • /
    • 2005
  • This paper investigated the mechanical and electrochemical properties of Al alloys in a slow strain rate test under various potential conditions. In general, Al and Al alloys do not corrode on formation of a film that has resistance to corrosion in neutral solutions. In seawater, however, $Cl^-$ ions lead to the formation and destruction of a passive film. In a potentiostatic experiment, the current density after 1200 sec in the potential range of $-0.68{\sim}-1.5 V$ was low. Comparison of the maximum tensile strength, elongation, and time to fracture indicated that the optimum protection potential range was from -1.5 to -0.7 V(SSCE).

  • PDF

Sensitivity Analyses of Finite Element Method for Estimating Residual Stress of Dissimilar Metal Multi-Pass Weldment in Nuclear Power Plant (원전 이종 금속 다층 용접부 잔류응력 예측을 위한 유한요소 변수 민감도 해석)

  • Song, Tae-Kwang;Bae, Hong-Yeol;Kim, Yun-Jae;Lee, Kyoung-Soo;Park, Chi-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.9
    • /
    • pp.770-781
    • /
    • 2008
  • In nuclear power plants, ferritic low alloy steel components were connected with austenitic stainless steel piping system through alloy 82/182 butt weld. There have been incidents recently where cracking has been observed in the dissimilar metal weld. Alloy 82/182 is susceptible to primary water stress corrosion cracking. Weld-induced residual stress is main factor for crack growth. Therefore exact estimation of residual stress is important for reliable operating. This paper presents residual stress computation performed by 6" safety & relief nozzle. Based on 2 dimensional and 3 dimensional finite element analyses, effect of welding variables on residual stress variation is estimated for sensitivity analysis.