• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.055 seconds

An Experimental Study on the Pond Sediment and Water Quality Purification using Oxygen Solubilization Device(OSD) System (산소용해수를 이용한 호소 저질 및 수질개선에 관한 실험적 연구)

  • Kim, Young-Taek;Bae, Yoon-Sun;Roh, Eun-Kyung;Park, Chul-Hwi;Lee, Yeon-Ku
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.94-103
    • /
    • 2006
  • The pollution in closing water can be caused by not only artificial factor like sewage but also natural factor like elution from sediment. In this study we analyzed Sediment Oxygen Demand (SOD) for verification of sediment purification effect and sediment elution experiment as well as general items like COD, TN, TP, SS to complement and assess the effect of sediment and water quality. The experiment result showed that the release rate of OSD system were 4 times and 3 times as large as control for P and Fe respectively. SOD for operated OSD system and control were $12.18gO_2{\cdot}m^{-2}{\cdot}d^{-1}$ and $47.95gO_2{\cdot}m^{-2}{\cdot}d^{-1}$. From water qualities analyzed by COD, TN, TP, SS, chlorophyll-a, the removal efficiency increase of TN, TP, chlorophyll-a and COD were about 10~20%, 40~50% and 10% respectively. In conclusion, OSD can contribute to improvement of both the waterbody and the sediment environment effectively.

Improvement of effluent water quality by sludge aeration at the conventional drinking water treatment plant (정수장 슬러지 폭기를 통한 방류수 수질 개선)

  • Choi, Ilgyung;Shin, Changsoo;Beak, Inho;Lim, Jaecheol;Jeong, Chanwoo;Lee, Sungjin;Park, Jungwook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.249-255
    • /
    • 2014
  • So many drinking water treatment plants are under various difficulties by new reinforced effluent standards. Since the target turbidity, much higher than annual average, for designing sludge thickener have to be set to confront high turbidity season, the sludge at thickener should be put up for a long time during usual days. So the soluble manganese and chloroform may be formed under the anaerobic environment in the sludge thickener when the sludge retention time is longer with low turbidity. This phenomenon results in difficulties to keep regulatory level of the discharged effluent. For an effort to overcome the problems, a sludge aeration was successfully implemented into the thickening process. As a result, the final effluent quality and sludge volume were much improved; 41 % of manganese, 62 % of chloroform and 35 % of sludge volume. Additionally, effluent quality was improved ; 61 % of Manganese on aeration with pH control and we could make sure of stability effluent quality despite a long sludge retention time. We recommended the standard of installation sludge aeration equipment to nationally supply water treatment plant under effluent water quality problem ; Manganese, Chloroform, etc.

Effects of Algae Growth on the Effluent of Wastewater Treatment Systems by Using Water Hyacinth (조류 성장이 부레옥잠을 이용한 폐수처리공법의 유출수에 미치는 영향)

  • Lee, Byung-Hun;Lee, Nam-Hee;Kim, Jeong-Suk
    • Journal of Environmental Science International
    • /
    • v.1 no.2
    • /
    • pp.81.2-92
    • /
    • 1992
  • Growing algae spread over open water surface of water hyacinth system the leaves of hyacinth prevented the passage of sunlight through the water surface. The objectives of this study were to investigate the effects of the algae growth on the effluent of water hyacinth wastewater treatment systems operated with the variation of an organic loading rate between 190 to 550 kg COD/ha.day. The effluent from the system contained algae was discharged for about 2-3 weeks from the beginning of experimental operation of water hyacinth systems. BOD and 55 concentration of effluents during algae growthing periods were higher than those during the period of algae control. But nitrogen and phosphrous romoval efficiencies during in algae growthing periods were slighty higher than those during the period of algae control.

  • PDF

Corrosion control of drinking water pipes by corrosion inhibitor (부식억제제에 의한 상수도관의 부식제어)

  • Hwang, Byung-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.6
    • /
    • pp.2306-2310
    • /
    • 2010
  • Corrosion is a complex series of oxidation/reduction reactions between at the water-metal surfaces and materials in which the water is stored or transported. With respect to the corrosion potential of drinking water, the primary concerns include the potential presence of toxic metals, such as lead and copper; deterioration and damage to the household plumbing, and aesthetic problems such as stained laundry, and bitter taste. This study was performed to evaluate the effects of corrosion inhibitors on corrosion rates, Fe and Cu release concentration in water distribution pipes. Decrease of corrosion rates were strongly related to phosphate corrosion inhibitors. Considering that typical corrosion processes consists of a series of electrochemical reaction at the metal surface in contact with water, corrosion rates were positively correlated with Fe release.

ANALYSIS ON MICROBIOLOGICALLY INFLUENCED CORROSION FAILURE CASE OF SUS316L STAINLESS STEEL WELDS

  • Miyano, Yasuyuki;Yamamoto, Michiyoshi;Watanabe, Kazuya;Kikuchi, Yasushi
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.133-138
    • /
    • 2002
  • Microbiologically Influenced Corrosion (MIC) was suspected in a corrosion failure of cooling system of stainless piping welded joint, carrying marine water. Marine water which is used for cooling water in a plant was transferred to the laboratory and used for experiment. In the first experiment, weld metal samples were exposed to the test solution for 56 days (marine water and sterilized marine water (control)). Surface condition of experimental coupons was observed using a Scanning Electron Microscope (SEM). In another experiment, free corrosion potential of these material was monitored for 56 days. Pitting corrosion was found in the coupons exposed to marine water. Free corrosion potential ennoblement was found to be significant compared to control. It was suspected that this corrosion case was MIC. In the second experiment, coupons were exposed to diluted nutrient medium containing single culture of microbes isolated from the MIC causing marine water sample used for the first experiment. After exposure test, surface condition of experimental coupon was observed using SEM. Pitting corrosion was found in coupons exposed to some of the isolates. The results indicate that they contribute to the corrosive effect of the SUS316L welds.

  • PDF

The Modernization of Automatic Control facilities of Hydro Power Plant (수력발전소 자동제어설비의 현대화)

  • Kwon, O-Geuk;Kwon, Young-June;Song, Young-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.69-70
    • /
    • 2008
  • Automatic control systems(AVR, Governor, Synchronizer) installed $1970{\sim}1980$ in K-water were considered to be rehabilitated around 2000. Moreover, Korea Power Exchange market system was changed from PPA (Power Purchase Agreement) to a bidding system. Therefore, depending on the power quality, the power provider could achieve additional profits. It is the excitation system and governor that have the functions of enhancing power necessities. During the 20 to 30 years of generator operation, there were many major and minor problems. Examples are SCR burnout (Andong: Excitation system), hunting (Imha: governor), field circuit breaker failure (Chungju 1st: excitation system), the rise of leakage current (Chungju 2nd: excitation system), power supply burnout (Chungju 2nd: governor). These are the typical examples of malfunction which hindered the generator operation and, consequently, diminished the profit of power business. In order to satisfy the needs of the power market and prevent malfunctions mentioned above, the rehabilitation of AVRs and governors were executed. A new system was made to have the flexibility of ancillary service (GF, AGC, etc.), PSS function. With user friendly HMI software, it is more convenient for the operator to fulfill suitable maintenance. It was possible to connect SCADA system by opening protocol of AVR, governor for the efficiency of operation and maintenance.

  • PDF

Problems and their Counter-measures in Water Quality Preservation (수질보전상의 문제와 대책)

  • Ryu Jae Keun
    • Journal of environmental and Sanitary engineering
    • /
    • v.2 no.2 s.2
    • /
    • pp.69-78
    • /
    • 1987
  • Due to the increase of population and development of industry, the demand of available water resources increased . Many reservoirs have been constructed in large scales to meet this urgent need , resulting in the increased amount of water resources. After the constructions, however, serious pollution-especially eutrophication-in some reservoirs become a socialaffair. Therefore, water quality control in these resources should be considered more intensively than any other environmental preservation policies. It also seems to be imminent to prepare the precautionary steps. Most water pollution in Korea-73 percent - can be traced to domestic sewage. It may rome as a surprise to Some, Industry is responsible for just 27 percent of ]Korea's water pollution. What he calls 'non-point' Sources, which may include agricultural Chemicals, Create only negligible amount of water pollution. Up to $15\%$ of domestic sewage is treated in Korea, which is quite low when compared with the waste processing in developed countries. So it is the most urgent matter to control the pollution sources. One of the precautionary plans, more urban domestic sewage treatment plants must be installed and operated efficiently. It is known that nutrients such as nitrogen and phosphorous are the major factors the process of eutrophication, which can be removed majorly by the tertiary or advanced treatment process.

  • PDF

The Improvement of Water Quality Purification through the Effective Management of Fallow Paddy Fields (휴경논의 효율적 관리를 통한 수질개선 효과 연구)

  • Jee, Yong-Keun;Kim, Sun-Joo;Kim, Phil-Shik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.1
    • /
    • pp.33-39
    • /
    • 2009
  • A number of fallow paddies field continues to increase because of adverse agricultural circumstance such as upsurge income of foreign products, increase of labor costs in local community, imbalance between productivity and profitability etc. Such fallow paddies are necessary to be protected against weeds and trees. If fallow paddies are not managed, it will be devastated and needed cost for re-cultivation. Therefore, management of gradually increased fallow paddy fields should be conducted. In this study, the effect of plants growth inhibition and water quality purification through the control of flood in fallow paddy were examined in an experimental field. The managed and unmanaged fallow paddies through the control of water depth were constructed in the experimental field. The monitoring was conducted from 2005 to 2007. As the result, the managed fallow paddies were more effective than the unmanaged ones on the growth inhibition and water purification. In addition, when the fallow paddy is managed with regular water depth, it was the most effective in the plants growth inhibition.

A study on dissolved air flotation (DAF) process control using decision algorithm (의사결정 알고리즘을 이용한 DAF 공정 제어에 관한 연구)

  • Jung, Woosik;An, Ju-Suk;Park, Ji-Young;Oh, Hyun-Je
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.409-414
    • /
    • 2017
  • In this study, we divided the process operation scenarios into three categories based on raw water temperature and turbidity. We will select and operate the process operation scenario according to the characteristics of the raw water. The number of algae in the DAF treated water has been analyzed to be less than 100 cells/mL. These results indicated that the DAF process is effective in removing the algae. In addition, the scenario of the integrated management decision algorithm of the DAF process was developed. DAF pilot plants ($500m^3/day$) process has shown a constantly sound performance for the treatment of raw water, yielding a significantly low level of turbidity (DAF treated water, 0.21~1.56 NTU).

Water table: The dominant control on CH4 and CO2 emission from a closed landfill site

  • Nwachukwu, Arthur N.;Nwachukwu, Nkechinyere V.
    • Advances in environmental research
    • /
    • v.9 no.2
    • /
    • pp.123-133
    • /
    • 2020
  • A time series dataset was conducted to ascertain the effect of water table on the variability in and emission of CH4 and CO2 concentrations at a closed landfill site. An in-situ data of methane/carbon dioxide concentrations and environmental parameters were collected by means of an in-borehole gas monitor, the Gasclam (Ion Science, UK). Linear regression analysis was used to determine the strength of the correlation between ground-gas concentration and water table. The result shows CH4 and CO2 concentrations to be variable with strong negative correlations of approximately 0.5 each with water table over the entire monitoring period. The R2 was slightly improved by considering their concentration over single periods of increasing and decreasing water table, single periods of increasing water table, and single periods of decreasing water table; their correlations increased significantly at 95% confidence level. The result revealed that fluctuations in groundwater level is the key driving force on the emission of and variability in groundgas concentration and neither barometric pressure nor temperature. This finding further validates the earlier finding that atmospheric pressure - the acclaimed major control on the variability/migration of CH4 and CO2 concentrations on contaminated sites, is not always so.