• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.041 seconds

Development of a Catch Basin Sump Insert to Reduce Mosquitoes

  • Kim, Dong Gun
    • Korean Journal of Environmental Biology
    • /
    • v.36 no.4
    • /
    • pp.554-557
    • /
    • 2018
  • A catch basin sump is one major habitat for mosquito larvae, especially in urban areas. This study developed a device for mosquito control, specifically for the catch basin sump. It consists of a housing, is a little smaller than the catch basin sump, numerous floating materials, which the key component for mosquito control, and mesh nets. The small balls or pyramid-shaped floating materials inhibit mosquito enclosures and spawning by significantly decreasing the surface area of the water, which is essential for the mosquito life cycle. These floating materials were designed to keep the water flowing. The mesh nets were installed to prevent the outflow of floating materials. The efficiency of the floating materials was tested with 3 conditions (1, 2, 3 layers of floating materials) and a control group. The emergence of mosquito adults decreased by 20% in one-layer, and 70-80% in second and third layers. Therefore, this device is expected to certainly contribute to mosquito population control in the catch basin sump.

Current Condition and Prospect of On-Site Domestic Wastewater Treatment Technologies (합병정화조 기술현황 및 전망)

  • 임연택
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.06a
    • /
    • pp.95-112
    • /
    • 1998
  • Water quality in the public water course has been polluted more seriously than ever before due to the increase of the number and aremount of pollution sources such as domestic and industrial wastewater. For water quality conservation, the Korean government has been trying to construct sewage treatment facilities continually, of which treatment capacity reached to 11,452,400m$^{3}$/day in 1996. Night soil treatment facilites of m nationwide have the treatment capacity of 24,038m$^{3}$/day. But water quality has not been improved because the sewer systems were insufficient and the treatment efficiencies of sewage were not high, enough. For renovation of water quality, miscellaneous domestic wastewater must be treated because 27g BOD/day out of total 40g BOD/person-day come from miscellaneous wastewater, comparing to 13g BOD/day from night soil. However, sole treatment purifier treat only night soil from the flushing toilet. Therefore, it may be desirable to treat the miscellaneous domestic wastewater and the night soil from flushing toilet together by joint treatment purifier system as on-site domestic wastewater treatment technology. In Korea, the joint treatment purifier system, introduced in 1997, have the benefit as follows; i) good water poiluion control effect, ii ) good effect on river water flow, iii) water pollution control with sewage treatment facility, and iv) rapid pollution control effect, etc. In order to achieve a good effect as stated before, i ) strengthening effluent guideline including BOD, nitrogen and phosphorus, ii ) specializing operation to maintain high performance, and iii) supporting its construction and maintenance costs by the governmental level may be necessary: In addition, automation system of joint treatment purifier, technology for its package and compactness, and a new bio-media bio-filter with higher capacity should be further developed in agreement with a more stringent effluent guideline.

  • PDF

Theory and Practices of Water Pollution Control by Wetland - a Case Study of Reed Wetland in Baiyangdian Lake

  • Li, Guibao;Zhou, Huaidong;Liu, Fang;Wang, Dianwu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.72-76
    • /
    • 2004
  • Wetland is an important eco-system on the earth and can effectively control agricultural non-point source pollution. Reed is a typical wetland plant for land/inland water ecotone in north China. The studies indicated that reed had a underground rooted-stem, which formed a 'high speeded-connecting vessels' i.e. reed root channel (RRC) in Baiyangdian lake of Hebei province. It spread predominantly along horizontal direction underground and are mainly distributed at 18-75 cm. The results of field work from healthy reed-wetland (HRW) and regarded reed-wetland (RRW) showed that the reed, averagely, in HRW is 4.2 m height, 1 cm diameter, 65/m2 density; in RRW is 2.4 m height, 3 mm diameter, 86/m2 density. These results indicated the regradation of the function of RRC in RRW. The results of laboratory work of sewage purification from reed soil column (RSC) $(0\~100cm)$ and wheat soil column (WSC) showed that the efficiency of purification to sewage, in RSC, is high than in WSC, especially for phosphorus. The efficiency of purification, in RSC, is $92.6\%$ for total phosphorus, $43.5\%$ for total nitrogen, $54.1\%$ fur COD, respectively; in WSC, is $86.0\%$ for total phosphorus, $241.3\%$ for total nitrogen, $29.8\%$ for COD, respectively.

  • PDF

Quality Control to Improve Reliability of Automatic Water Quality Data (수질자동측정망 자료의 신뢰성 제고를 위한 정도관리)

  • Lim, Byung-Jin;Hong, Eun-Young;Kim, Hyun-Ook
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.2
    • /
    • pp.338-344
    • /
    • 2010
  • The automatic water quality monitoring system (AWQMS) have been installed to immediately response to any pollution incident. It also make it possible to conduct the task efficiently regarding water quality control. The purpose of this study is to enhance reliability by securing accuracy of automatic water quality data through quality assessment (QA) for temperature, pH, dissolved oxygen (DO), electric conductivity (EC), total organic carbon (TOC). The result of comparison between manual and automatic data, relative accuracy of general items (temperature, pH, EC, DO) and TOC were mostly satisfied with guideline (i.e. less than 20%). On the other hand, relative accuracy of DO between sampling site and housing site was somewhat against the guideline. The contamination by attaching algae and microorganism in the pipeline is considered as main cause. After backwashing the pipeline, DO concentration was increased up to 53%. Therefore, pipeline management is recognizable as important thing to secure reliability of water quality data.

Impact Assessment of Liquid Manure Application on Soil and Shallow Groundwater in Poplar Experimental Site (액비 시비에 따른 포플러시험포 토양수 및 천층지하수 수질 영향 평가)

  • Hong, Eun-Mi;Choi, Jin-Yong;Nam, Won-Ho;Lee, Sang-Hyun;Yoo, Seung-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.1
    • /
    • pp.25-35
    • /
    • 2015
  • As livestock manure treatment is becoming a problem, manure application in forest plantation is recommended as an alternative. In this study, to investigate the impact due to liquid manure application in forest plantation, soil, soil water and shallow groundwater quality had been monitored in poplar experimental site where the liquid manure (LM) was applied. Water samples were collected weekly during growing season (April to October) from 2008 to 2011. From the monitoring results, phosphorus concentration in the soil and soil water had no significant difference between LM and control plots. $NO_3$-N concentration of soil water in LM, however, showed higher concentration (13.6 mg/l at 40 cm, 35.1 mg/l at 80 cm) than control plot (1.5 mg/l at 40 cm, 0.5 mg/l at 80 cm). In case of shallow groundwater quality, pH, heavy metal, etc. were satisfied to the national agricultural water quality standard of groundwater and there were no significant difference between upstream and downstream. The $NO_3$-N concentration of shallow groundwater was also not exceeded the national drinking water standard. However, $NO_3$-N concentration in soil water and downstream of shallow groundwater had increased in 2011 when non-composted LM was applied mostly in non-growing season of tree (September). From the results, it is important to control nitrogen source, application time and decomposed or not when LM is applied. In addition, to investigate nitrate source, further long-term monitoring and modelling could be necessary.

Quality Control on Water-level Data in Agricultural Reservoirs Considering Filtering Methods (필터링 기법을 이용한 농업용저수지 수위자료의 품질관리 방안)

  • Kim, Kyung-hwan;Choi, Gyu-hoon;Jung, Hyoung-mo;Joo, Donghyuk;Na, Ra;Choi, Eun-hyuk;Kwon, Jae-Hwan;Yoo, Seung-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.5
    • /
    • pp.83-93
    • /
    • 2021
  • Agricultural reservoirs are important facilities for storing or managing water for the purpose of securing agricultural water, creating and expanding agricultural production bases, and using them to increase agricultural production. In particular, the Korea Rural Community Corporation (KRC) manages agricultural reservoirs scattered across the country, and officially recognizes and distributes hydrological data to increase their public utilization and aims to improve the value of water resources. Data on the water level of agricultural reservoirs are important. However, errors such as missing values and outliners limit utilization of the data in various fields of research and industry. Therefore, water quality data measures should be devised to increase reliability. this study categorized different error types and looked at automatic correction methods to enhance the reliability of the vast hydrological data. In addition, the water level data corrected from errors were compared to the reference hydrologic data through expert judgment in accordance with the quality control procedure, and the most appropriate measures were verified. As KRC manages more agricultural reservoirs than any other institution, the proposed method of efficient and automatic water level data correction in this study is expected to increase the availability and reliability of the hydrological data.

Multi-objective Optimization of BMPs for Controlling Water Quality in Upper Basin of Namgang Dam (남강댐 상류유역 수질관리를 위한 BMPs의 다목적 최적화)

  • Park, Yoonkyung;Lee, Jae Kwan;Kim, Jeongsook;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.6
    • /
    • pp.591-601
    • /
    • 2018
  • Optimized BMP plans for controlling water quality using the Pareto trade-off surface curve in upper basin of Namgang Dam is proposed. The proposed alternatives consist of BMP installation scenarios in which the reduction efficiency of non-point pollutants is maximized in a given budget. The multi-objective optimization process for determining the optimal alternatives was performed without direct implementation of a watershed model such as SWAT analysis, thereby reducing the time taken. The shortening of the calculation time further enhances the applicability of the multi-objective optimization technique in preparing regional water quality management alternatives. In this study, different types of BMP are applied depending on the land use conditions. Fertilizer input control and vegetative filter strip are considered as alternatives to applying BMP to the field but only control of fertilizer input can be applied to rice paddies. Fertilizer input control and vegetative filter strip can be installed separately or simultaneously in a hydrologic response unit. Finally, 175 BMP application alternatives were developed for the water quality management of the upper river basin of Namgang dam. The proposed application alternative can be displayed on the map, which has the advantage of clearly defining the BMP installation location.

An experimental study on the multiple parameter switching control for floor heating system (바닥 난방공간의 다인자 제어에 관한 실험적 연구)

  • Cho, S.H.;Tae, C.S.;Jang, C.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.472-483
    • /
    • 1997
  • An experimental facility consisting of two $3{\times}4.4{\times}3.8m$ rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparision of two different control stratigies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study : (i) conventional on-off control based on feedback from room air temperature (ii) TPSC(two parameter switching control) (iii) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

Effects of Cheongyoung-tang on CHT-Induced Brain Edema and Neurological Disturbance Symptom in Rats (청영탕이 CHT로 유발된 백서의 뇌부종 및 신경장애 증상에 미치는 영향)

  • Cheong Sang Su;Lee Sang Kwan;Sung Kang Keyng
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.5
    • /
    • pp.948-954
    • /
    • 2002
  • This study was carried out to evaluate Effects of Cheongyoung-tang on CHT-Induced Brain Edema and Neurological Disturbance Symptom in Rats. we make a comparative study of the such parameters as neurological severity score(NSS) and changes in water content, lactate, glucose and hematological substance. 1. ΔNSS increased in CYT1 and CYT2 as compared with the control group, which showed no efficacy. 2. In water content of both hemispheres, CYT1 and CYT2 as compared with the control group have no difference. 3. Water content of the left hemisphere decreased in CYT1 and CYT2 as compared with the control group. 4. The lactate level in serum decreased in CYT1 and CYT2 as compared with the control group. 5. In hematological changes, RBC, PLT and MCHC increased in CYT1 and CYT2 as compared with the control group, but MCV decreased. According to these results, CYT has an effect on CHT-induced brain edema and neurological symptom.

Development of a Method for Detecting Unstable Behaviors in Flume Tests using a Univariate Statistical Approach

  • Kim, Seul-Bi;Seo, Yong-Seok;Kim, Hyeong-Sin;Chae, Byung-Gon;Choi, Jung-Hae;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.24 no.2
    • /
    • pp.191-199
    • /
    • 2014
  • We describe a method for detecting slope instability in flume tests using pore pressure and water content data in conjunction with a statistical control chart analysis. Specifically, we conducted univariate statistical analysis on x-MR control chart data (pore pressure and water content) collected at several points along the flume slope, which we separated into three parts: upper, middle, and lower. To assess our results in the context of landslide forecasting and warning systems, we applied control limit lines at $1{\sigma}$, $2{\sigma}$, and $3{\sigma}$ levels of uncertainty. In doing so, we observed that dispersion time varies depending on the control limit line used. Moreover, the detection of instabilities is highly dependent on the position and type of sensor. Our findings indicate that different characteristics of the data on various factors predict slope failure differently and these characteristics can be identified by univariate statistical analysis. Therefore, we suggest that a univariate statistical approach is an effective method for the early detection of slope instability.