• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.042 seconds

A Study on the Correct injection method for low dissolution liquid in the Water Treatment Plant (상수도의 저용해성 액체 정량투입 방안 연구)

  • Kim, Jin-Hoon;Park, Jong-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.273-277
    • /
    • 2005
  • The large particles of suspended matter in raw water can be removed by allowing them to settle out in a presedimentation basin. But there are smaller particles in almost all surface water and some groundwater that will not settle out within a reasonable time without some help to accelerate the process, In the coagulation and flocculation processes, nonsettleable solids are converted into large and heavier settleable solids by physical-chemical changes broght about by adding and mixing coagulant chemicals into the raw water. The object of this research was to improve corrective injection method for low dissolution liquid in the water treatment plant. A sort of chemical feed equipment are diaphram pump, flow control in combined magnetic flowmeter md control valve, roto dipper wheel system and tube pump. Particularly low dissolution liquid (Calcium Hydroxide) put in a bit by feed equipment, tube pump is very useful method for corrective injection method in the water treatment plant.

  • PDF

Why the Mediterranean Sea Is Becoming Saltier

  • Bryden, Harry-L.;Boscolo, Roberta
    • Journal of the korean society of oceanography
    • /
    • v.37 no.3
    • /
    • pp.117-124
    • /
    • 2002
  • Anthropogenic changes have been made to the water budget for the Mediterranean Sea as a result of river diversion projects. The decrease in freshwater inflow to the Mediterranean represents an effective increase in the overall net evaporation over the basin. Hydraulic control models for the exchange between the Mediterranean and Atlantic through the Strait of Gibraltar predict that the salinity of the Mediterranean should increase if the net evaporation over the Mediterranean increases. Increases in the salinity of the deep waters in both the western and eastern Mediterranean basins have been observed. The causes of such higher deep water salinity are attributed to increases in intermediate water salinity which are ultimately mixed down into the deep sea during wintertime buoyancy loss events. The pattern of the Mediterranean salinity increase is instructive for understanding how the water mass properties in a basin change over time as a result of anthropogenic changes.

A Sutdy on the Water Quality Management using Fllow Paddy (유휴농지를 이용한 수질관리방안 연구)

  • Kim, Hyung-Joong;An, Yeul;Kim, Sun-Joo;Kim, Phil-Shik
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.485-489
    • /
    • 2005
  • Fallow paddy has been increased in disadvantageous farming condition area because of importation of foreign agricultural products, labor cost and the imbalance between farming cost and agricultural products price since 1990. The fallow paddy that has gradually increased needs to be prevented from the devastation by weed breeding for re-cultivation. In this study, two fallow paddies that manage with different water depth from the experimental field were selected for observation, and analysis of water quality, water balance and plant body change. The managed fallow paddy was more effective in water quality purification and plants growth control than non-managed fallow paddy. And the fallow paddy managed with a some degree water depth was the most effective field on weed control.

  • PDF

Brushless DC Motor Control for Photovoltaic Water-Pumping System (PV Water Pumping 시스템을 위한 BLDC 모터 제어)

  • 김성남;최성호;조정민;전기영;이승환;한경희
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.50 no.3
    • /
    • pp.109-116
    • /
    • 2001
  • In this paper, we adapted BLDC motor to PV water pumping systems to maintain high efficiency in the wide speed area. Also, to design confidence we adapted the vector control that drive the maximum torque at each speed limit. We designed optimal gain value of current, speed and pressure PI controller. Inverter gate pulse used Space Vector PWM to reduce torque pulsation of BLDC motor. According to, it was improve general matters of high water storage tank method by direct water supply pumping method.

  • PDF

A Fundamental Study on the Nutrient Solution Cooling System Utilizing Ground Water (지하수를 이용한 양액냉각시스템 개발에 관한 기초연구)

  • 남상운;손정익;김문기
    • Journal of Bio-Environment Control
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 1993
  • Experimental and theoretical analyses were carried out to investigate the heat exchange characteristics of the nutrient solution cooling system utilizing ground water. The material of heat exchanger used in the experiment was polyethylene and the cross-flow type was adapted in which nutrient solution was mixed and ground water unmixed. For the exchanger surface area of 0.33$m^2$ and flow rates of ground water of 1-6$\ell$/min, NTU(number of transfer units) and effectiveness of experimental heat exchanger were 0.1-0.45 and 10-35%, respectively. Therefore these results showed that the hydroponic greenhouse of 1,000$m^2$(300 pyong) with the ground water of 10$m^2$/day could cover about 55-70% of maximum cooling load in summer.

  • PDF

Study on Establishment of the Industrial Wastewater Effluent Limitations Based on Best Practicable Control Technology Currently Available - Case Study for the Pulp, Paper and Paper Board Manufacturing (실용 가능한 최적처리기술에 근거한 산업폐수 배출허용기준 설정 연구 - 펄프.종이 및 종이제품 제조시설 적용 사례)

  • Kim, Jaehoon;Shin, Jinsoo;Lee, Chulgu;Lee, Jungyoung;Lee, Youngsun;Yu, Soonju
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.608-614
    • /
    • 2012
  • The effluent limitation of industrial wastewater is based on uniform regulatory criteria for effluent discharge facilities of all in Korea. But, an individual effluent limitation on each effluent discharge facility is widely applicable for regulation of industrial wastewater in US.EPA. To decide an individual effluent limitation, TBEL (Technology-based effluent limitation) and WQBEL (Water quality-based effluent limitation) are used. TBEL is based on the capability of a treatment technology to reduce the pollutants. WQBEL is based on ambient water quality standards. In this study, TBEL were derived for the pulp, paper and paper board manufacturing based on best practicable control technology currently available. It was suggested that effluent limitations were $BOD_5$ 4.7 mg/L, $COD_{Mn}$ 44.3 mg/L, SS 13.2 mg/L, TN 1.4 mg/L, TP 0.15 mg/L and best practicable control technology currently available (BPT) was neutralization, activated sludge treatment and coagulation and sedimentation for the pulp, paper and paper board manufacturing.

Analysis of Operation Parameters of Pilot-Scale Packed-Absorption System for Airborne Methyl Ethyl Ketone Control (공기 중 메틸에틸케톤 제어를 위한 Pilot-Scale 흡수 시스템의 운영인자 분석)

  • Jo, Wan-Kuen;Kim, Wang-Tae
    • Journal of Environmental Science International
    • /
    • v.20 no.4
    • /
    • pp.501-509
    • /
    • 2011
  • Unlike many laboratory-scale studies on absorption of organic compounds (VOCs), limited pilot-scale studies have been reported. Accordingly, the present study was carried out to examine operation parameters for the effective control of a hydrophilic VOC (methyl ethyl ketone, MEK) by applying a circular pilot-scale packed-absorption system (inside diameter 37 cm ${\times}$ height 167 cm). The absorption efficiencies of MEK were investigated for three major operation parameters: input concentration, water flow rate, and ratio of gas flow-rate to washing water amount (water-to-gas ratio). The experimental set-up comprised of the flow control system, generation system, recirculation system, packed-absorption system, and outlet system. For three MEK input concentrations (300, 350, and 750 ppm), absorption efficiencies approached near 95% and then, decreased gradually as the operation time increased, thereby suggesting a non-steady state condition. Under these conditions, higher absorption efficiencies were shown for lower input concentration conditions, which were consistent with those of laboratory-scale studies. However, a steady state condition occurred for two input concentration conditions (100 and 200 ppm), and the difference in absorption efficiencies between these two conditions were insignificant. As supported by an established gas-liquid absorption theory, a higher water flow rate exhibited a greater absorption efficiency. Moreover, as same with the laboratory-scale studies, the absorption efficiencies increased as water-to-gas ratios increased. Meanwhile, regardless of water flow rates or water-to-gas ratios, as the operation time of the absorption became longer, the pH of water increased, but the elevation extent was not substantial (maximum pH difference, 1.1).

A Novel Water Surface Detection Method Based on Correlation Analysis for Rectangular Control Area (직사각형 검사영역의 상관도 분석을 통한 수면위치 탐색 방법)

  • Lee, Chan Joo;Seo, Myoung Bae;Kim, Dong Gu;Kwon, Sung Il
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.12
    • /
    • pp.1227-1241
    • /
    • 2012
  • In this study, a novel water surface detection method was proposed. In the method water surface is detected by analysis on correlation coefficients obtained from rectangular control areas of the same vertical position in two successive images including both water surface and staff gauge. Four methods respectively based on threshold, peak, slope and variance ratio, are used to identify water surface from vertical distribution of correlation coefficient. In addition, swaying correction algorithm and statistical filtering are applied to minimize outliers caused by positional image mismatch. Images taken from 28 different sites during low flow were tested to evaluate the method. Mean relative error to eye measurement was approximately from 3.4 to 5.7 cm. As long as water surface moves, this method can be used to improve image stage gauge by supplementing the previous water surface detection method.

Change in plasma cortisol and glucose levels of Oncorhynchus keta according to water temperature

  • Young Seok Seo;Hyo Bin Lee;Joo Hak Jeong;Seong Jun Mun;Han Kyu Lim
    • Fisheries and Aquatic Sciences
    • /
    • v.26 no.2
    • /
    • pp.117-132
    • /
    • 2023
  • Chum salmon (Oncorhynchus keta) is a species of anadromous salmonid inhabiting coastal rivers in the North Pacific and the Arctic in the Bering and is the most widely distributed among Pacific salmon species. It is an important fish species in Korea as the salmon releasing project is being actively carried out. This study was conducted to investigate changes in the physiological activity of O. keta according to water temperature. Three experiments were conducted according to the water temperature and period, and the plasma concentrations of cortisol and glucose were analyzed from the blood samples of the experimental groups. Experiment I is a short-term water temperature experiment, in which water temperature stimulation was given for 4 hours at water temperatures of 12℃, 16℃ (control), 20℃, and 24℃, and a recovery period was given for 4 hours. Experiment II is an experiment in which water temperature stimulation was given for 24 hours, 48 hours, and 72 hours at a high temperature of 24℃, and a recovery period was given for 12 hours, respectively. Experiment III is a long-term water temperature experiment, in which the water temperature was 12℃, 16℃ (control), 20℃, and 24℃ for 8 weeks. As a result of the experiment, in Experiment I, there was no significant difference in the survival rate between the experimental groups, but the concentration of cortisol and glucose in the plasma according to the set water temperature showed a significant difference. In Experiment II, there was no significant trend according to the maintenance time of the high-temperature state, but as the temperature increased, the plasma cortisol and glucose levels significantly increased compared to the control group. In Experiment III, all of the experimental group C (24℃) died in the 1st week, and there was no significant difference in the plasma glucose at the 1st and 8th weeks among the remaining experimental groups.