• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.037 seconds

Development of intelligent coagulant feeding system (지능형 응집제 투입 시스템의 개발)

  • Chung, Woo-Seop;Oh, Sueg-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.6
    • /
    • pp.652-658
    • /
    • 1997
  • Coagulant feeding control is very important in the water treatment process. Coagulant feeding is related to the raw water quality such as turbidity, alkalinity, water temperature, pH and so on. However, since the process of chemical reaction has not been clarified so far, coagulant dosing rate has been decided by jar-test. In order to overcome the difficulty mentioned above, Fuzzy Neural Network to fuse fuzzy logic and neural network was proposed, and the scheme was applied to the automatic determination of coagulant dosing rate. This algorithm can automatically identify the if-then rules, tune the membership functions by utilizing expert's experimental data. The proposed scheme is evaluated by computer simulation and interfaced with coagulant feeder operated by magnetic flowmeter, control valve and PLC. It is shown that coagulant feeding according to real time sensing of water quality is very effective.

  • PDF

Approaches to Internal Corrosion Control Technologies by Controlling Water Quality in Water Treatment Systems (수질제어를 통한 관 내부 부식방지 기술의 정수처리공정 적용방안)

  • Seo, Dae-Keun;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.509-518
    • /
    • 2006
  • Although final water of domestic water treatment plants almost contains highly corrosive characteristics, the countermeasures for eliminating internal corrosion of pipeline system have not been conducted yet by controlling water quality in plants. The technologies of internal corrosion control are to control water quality parameters(pH, Alkalinity, and Calcium Hardness etc.) and to use corrosion inhibitor. Under the conditions of domestic water treatment, first of all, the technologies of adjusting water quality parameters has to be considered. Otherwise, The technology of using corrosion inhibitor is favorably thought to be applied with the technology of adjusting water quality parameters in accordance with the result of availability for water treatment process. Since the technology of adjusting water quality parameter influences on other water treatment processes, the guideline of water quality management to be apt for water quality characteristic is required to be estabilished. While the selection of proper chemicals and technologies is dependent upon the raw water characteristics and water treatment process, typically, the technology of $Ca(OH)_2$ & $CO_2$ additions is considered more effective than other technologies in order to adjust pH and Alkalinity, increase $Ca^{2+}$ and form $CaCO_3$ film

Antioxidative and Amylase Activity of Soybean Sprouts by Treatment of Green Tea Water Extract (녹차 물 추출액으로 재배한 콩나물의 항산화성 및 효소 활성도)

  • Kim Kum-Suk;Jung Su-Young;Chung Jong-Gab;Shin Mee-Kyung
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.16 no.4
    • /
    • pp.447-452
    • /
    • 2006
  • This study examined the growth and sensory characteristics of soybean sprout cultured at 25$\pm$1$^{\circ}C$ for 4 days with distilled water control and green tea extracted water (0.03% and 0.05%). The proximate composition of soybean sprout in the green-tea water was better than that of the control in ash, protein and fat, while the soybean sprout was especially higher in 0.05% green-tea water. The contents of vitamin C and $\beta$-carotene were higher in soybean sprout in green-tea water than the control. The total free amino acids composition of soybean sprout in green-tea water was better than that of the control, with the highest being obtained in soybean sprout in 0.03% green-tea water. Antioxidative activity was assayed by DPPH radical scavenging ability with spectrophotometer at 514 nm. The soybean sprout in green-tea water was higher than control. The amylase activity of the soybean sprout increased steadily during the first 4 days and that of the control was higher than soybean sprout in green-tea water. The proteinase of soybean sprout steadily increased during 4 day culture. Furthermore, the proteinase activity of soybean sprout in green-tea water was higher than that of the control up to 2 days. Whereas after 3 days, it was the highest in 0.03% green-tea water and then decreased remarkably in 0.05% green-tea water.

  • PDF

A Study on the economic analysis of the standing water level control system (SAL상수위 제어시스템의 경제성 분석에 관한 연구)

  • Hong, Jong-In;Hong, Seong-Wook;Kim, Sang-Won;Yang, Jin-Kook
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.281-283
    • /
    • 2013
  • In this paper, standing water level control system and a comparison of existing methods (anchor, PDD, DM) and economic analysis was conducted. 1) Cost PDD method (6%), DM system (4%), and the SAL standing water level control system (4%), except for the anchor system is similar to the construction of three methods based on the portion of the anchor system was analyzed that. 2) construction and maintenance costs compared with the sum of the partial was, anchor system (100%), PDD method (39%), DM system (37%), the SAL standing water level control system (21%), the SAL standing water level control system was identified as the lowest cost method of.

  • PDF

A New Directionin the Advance of TM/TC System (물관리자동화시스템의 발전방향)

  • 고광돈;여운식
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.99-104
    • /
    • 1999
  • In 2000 FFIA , FIA, RDC are united into new corporation. This corporation will manage rural water with TM/TC(Tele-Monitoring/Tele-Control) system. Most systems which were adopted in TM/TC system were Closed Control System which use exclusive network and protocol . Closed Control System can not support new corporation's requirement in water management system. Therefore, new corporation should adopt Open Control System as standard rural water management system. Open Control System support Fieldbus technology, TCP/IP various protocols, programming model, OPC which is essential to the water management program, and so on.

  • PDF

A Study on the Worter-gate Control Device Development using Radio Communication (무선통신을 이용한 수문제어장치 개발에 관한 연구)

  • 이진구;김인주;정영재;손준식;성백섭;김일수;박창언
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.612-615
    • /
    • 2002
  • This paper begin a new approach in the water-gate control using radio communication. The dissertation is on the controllable device development of water-gate in the remote distance from water-gate trough the transceiver by radio communication. The proposed water-gate control device is simpe in structure, an suitable for implementation of water-gate control in the remote distance. The remote controller water-gate device inspected the up and down motion of water-gate through the LCD displayer, so that it was very safety driving about the surroundings imformation, over loading and position of water-gate, and so on.

  • PDF

Automatic control problems of VVVF converter-based variable-frequency type air (VVVF기를 기초한 가변식기압급수설비의 자동제어 문제)

  • 박용규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.468-468
    • /
    • 1991
  • The variable-frequency type water supply equipment, which adopts the variable-voltage and variable-frequency converter(VVVF converter) to govern automatically the rotating speed of a pump, can save 15-20% of power, as compared with a throttle-controlled pump device or an airpressurized water supply equipment, and is finding a wide application. However, it still has some disadvantages : greater pressure fluctuations during switching over the pump and prolonged low-effeciency running of the pump in the case of small consumption of water. Therefore, it is difficult to apply the equipment to the fire water supply system where the water should not be put into use unless a fire takes place, and the water pressure in pipelines should permanently remain constant. This paper introduces the automatic regulation principle of the variable-frequency type air-pressurized water supply equipment (hereafter referred to as simply BFQS equipment) for dual purposes of daily life and fire control, which combined both technologies of speed governing by a converter and air-pressurized water supplying, then discusses some problems related to automatic control, and finally gives the experimental results of an embodiment-BPQS-100-50 water supply equipment.

  • PDF

Water Quality Control System Development for Cooling Towers (냉각탑 수질관리를 위한 자동화 시스템 개발)

  • Lee, Ki-Keon;Song, Moo-Jun;Lee, Young-Jae;Sung, Sang-Kyung;Kang, Tae-Sam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.1
    • /
    • pp.36-41
    • /
    • 2008
  • Cooling tower is an important equipment of the cooling systems for large buildings like factory and department store. Water used for cooling in cooling tower is reused continuously. If the water is polluted, corrosion and scale can happen at equipments and pipes. In order to prevent this problem, it is necessary to control the water quality using chemicals. To control the water quality, an automatic control system is designed, fabricated, and experimented. The control system is based on an imbedded microcontroller. Relays are used for power driving, an LCD and LED for display, and RS485 for remote data acquisition. Monitoring program is also developed for easy man-machine interface and extraction of data stored in the imbedded processor and EEPROM. The control system calculates amounts of chemicals necessary using sensor data and injects the chemicals into the cooling tower on proper time. The developed water quality control system is expected to reduce cost of maintenance and extend the lifetime of the cooling systems with low cost.

Robust sliding mode control for a USV water-jet system

  • Kim, HyunWoo;Lee, Jangmyung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.2
    • /
    • pp.851-857
    • /
    • 2019
  • A new robust sliding mode control with disturbance and state observers has been proposed to control the nozzle angle of a water-jet system for a Unmanned Surface Vehicle (USV). As the water-jet system of a ship is subjected to direct disturbances owing to the exposure to the marine environment in water, it requires a robust control. A state observer and a disturbance observer are added to the water jet nozzle control system to achieve a robust control against disturbances. To verify the performance of the proposed algorithm, a test bed is constructed by a propulsion system used in the popular USV. This proposed algorithm has been evaluated by comparing to the existing algorithm through experiments. The results show that the performance of the proposed algorithm is better than that of the conventional PID or sliding mode controller when controlling the steering of the USV with disturbances.

Performance of self-curing concrete as affected by different curing regimes

  • El-Dieb, A.S.;El-Maaddawy, T.A.
    • Advances in concrete construction
    • /
    • v.9 no.1
    • /
    • pp.33-41
    • /
    • 2020
  • In this study, polyethylene glycol (PEG) and polyacrylamide (PAM) have been used as self-curing agents to produce self-curing concrete (SC). Compressive strength, ultrasonic pulse velocity (UPV), bulk electrical resistivity, chloride ion penetrability, water permeability, and main microstructural characteristics were examined under different curing regimes, and compared to those of the control concrete mixture with no self-curing agents. One batch of a control mixture and one batch of a SC mixture were air-cured in the lab to act as non-water-cured samples. The water curing regimes for the control mixture included continuous water curing for 3, 7, and 28 days and periodical moist curing using wetted burlap for 3 and 7 days. Curing regimes for the SC mixtures included 3 days of water curing and periodical moist curing for 3 and 7 days. SC mixtures showed better microstructure development and durability performance than those of the air-cured control mixture. A short water curing period of 3 days significantly improved the performance of the SC mixtures similar to that of the control mixture that was water cured for 28 days. SC concrete represents a step towards sustainable construction due to its lower water demand needed for curing and hence can preserve the limited water resources in many parts of the world.