• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.039 seconds

Effect of Glucose-Sweetened Drinks on Blood Glucose, Energy, and Water Intake at a Meal 3h Later in Healthy Males

  • Kim, Seok-Young
    • Nutritional Sciences
    • /
    • v.9 no.4
    • /
    • pp.280-287
    • /
    • 2006
  • The aims of this study were to describe the effects of glucose-sweetened drinks on blood glucose, energy, and water intake at a meal 3 hours later. The effect of blood glucose on prandial energy intake and the relationship between water and energy intake during a meal were also determined. Twenty healthy normal-weight men were fed pizza test meals 3h after consuming four drinks of 0, 50g, 65g, and 75g glucose in random order, within-subjects design. Blood samples were measured at baseline and every 30 min after ingestion of drinks and 30min after the end of the test meal and the appetite was also assessed by visual analog test at the same interval. The results of this study showed that various glucose drinks altered blood glucose responses compared with that of water control(p<0.0001). Blood glucose areas under the curve(AUC) for glucose-sweetened drinks were significantly(p<0.05) higher than that for the control over 3 hours after a drink and 30 min after the test meal. Consumption of the glucose-sweetened drinks significantly increased(p<0.05) energy and water intake at a test meal compared with the water control, except the drink containing 75g glucose. For all drinks combined, the energy intake was negatively correlated with the blood glucose and positively correlated with the volume of water consumed at a test meal at 3 hours later.

Design of pole-assignment self-tuning controller for steam generator water level in nuclear power plants (원전 증기 발생기 수위 제어를 위한 자기 동조 제어기 설계)

  • Choi, Byung-Jae;No, Hee-Cheon;Kim, Byung-Kook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.2 no.4
    • /
    • pp.306-311
    • /
    • 1996
  • This paper discusses the maintenance of the water level of steam generators at its programmed value. The process, the water level of a steam generator, has the nonminimum phase property. So, it causes a reverse dynamics called a swell and shrink phenomenon. This phenomenon is severe in a low power condition below 15 %, in turn makes the start-up of the power plant too difficult. The control algorithm used here incorporates a pole-assignment scheme into the minimum variance strategy and we use a parallel adaptation algorithm for the parameter estimation, which is robust to noises. As a result, the total control system can keep the water level constant during full power by locating closed-loop poles appropriately, although the process has the characteristics of high complexity and nonlinearity. Also, the extra perturbation signals are added to the input signal such that the control system guarantee persistently exciting. In order to confirm the control performance of a proposed pole-assignment self-tuning controller we perform a computer simulation in full power range.

  • PDF

A Study on the Energy Saving Method by controlling Capacity of Sea Water Pump in Central Cooling System for Vessel (선박용 중앙냉각시스템의 해수 펌프 용량조절에 따른 에너지 절감 기법에 관한 연구)

  • Lee, Ji-Young;Yoo, Heui-Han;Kim, Yun-Hyung;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.592-598
    • /
    • 2007
  • The fuel charge is getting higher in navigation cost. Therefore, shipowners try to find the method for reducing oil consumption. ESS(Energy Saving System) is one of he method. ESS is the system consisted with two inverters, ESS control unit and monitoring system. Two inverters control two main sea water cooling pumps. In the ESS control Unit, the control algorithm finds optimized point to decrease a power consumption of main sea water cooling pumps. Monitoring system observes ESS not to work improperly. ESS is experimented in the laboratory with real condition and analyzed in every view. After experiment, the result of the experiment shows that the control algorithm works correctly and safely. ESS has a plan to be operated in the ship soon. In that case, additional devices are needed to connect ESS with cooling system of the vessel. So the development of addition device is needed and being studied.

Digital variable structure control of a hot-water heating control system with long dead time (긴 지연시간을 갖는 온수난방 제어시스템의 디지틀 가변구조제어)

  • 안병천;장효환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.232-237
    • /
    • 1991
  • Digital Variable Structure Controller(DVSC) is proposed to control variable speed recirculating pump for hot-water heating control system. In this study, nonlinear sliding line is used beyond output error boundary layer and PID sliding line is used within the layer. For long dead time compensation, constraint is added to Smith predictor algorithm. Steady state error is eliminated by using the proposed sliding line in spite of heating load change. By decreasing sampling time, good sliding motion is yielded but system output noise bv flow dynamics is amplified.

  • PDF

Optimization of Water-Reusing Network among the Industries in an Eco-Industrial Park Complex Using Water Pinch Technology (워터핀치기술을 이용한 생태산업단지 내 기업간 용수 재이용망 최적화)

  • Kim, Young-Soo;Kim, Hyun-Joo;Lee, In-Beum;Yoo, Chang-Kyoo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.11
    • /
    • pp.1165-1173
    • /
    • 2008
  • An water-reuse network design has drawn attention as a systematic method of reducing fresh water usage and increasing water-using efficiency. The final goal of an eco-industrial park(EIP) is accomplishing industrial sustainability and constructing water-reuse network can be a solution. When designing water-reuse network connecting various processes which consume water, the water pinch technology can be used frequently, since it simultaneously minimize freshwater usage and wastewater discharge. In this research water pinch technology is applied to develop an effective water-reuse network in an EIP. Three scenarios based on different reusing strategies were developed. The results show that the final water-reuse network can reduce the total fresh water usage more than 30%, while the water expenses decrease by 20%. It can be concluded that water pinch technology is an effective tool to optimize water-reuse network among different industrial facilities.

Effect of the Antler (Deer Horn) Water Extract on the Stress Resistance in Mice (녹용수침액(鹿茸水浸液)이 Mouse의 Stress 방어작용에 미치는 영향(影響))

  • Ko, Geun-Il
    • Journal of Pharmaceutical Investigation
    • /
    • v.11 no.2
    • /
    • pp.11-15
    • /
    • 1981
  • Antler, deer horn, occupies a particular place in oriental folk medicine as so called tonic remedy. In order to study on the effects of Antler water extract on stress resistance in mice, quantitative response was measured for the change of spontaneous activity by chemical stress drugs in the control group or the Antler water extract pretreated group. Spontaneous activity in mice was measured by counting the number of interruptions of light. The results of experiment were summerized as follows; I) In case of administrating Antler water extract 10mg/kg, 20mg/kg, 50mg/kg, and 100mg/kg, no significant change was observed in spontaneous activity in comparison with the control group. II) In case of administrating Antler water extract for 5 days or 10 days, no significant change was observed in spontaneous activity by chemical stress drugs, caffein and chloropromazine, in comparison with the control group.

  • PDF

Domestic Legislation for Acceptance of ' International Convention for the Control and Management of Ship's Ballast Water and Sediments ' (밸러스트수 국제협약 수용을 위한 입법화 방안)

  • Kim Kwang-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2005.11a
    • /
    • pp.171-184
    • /
    • 2005
  • As recently, ' International convention for the control and management of ship's ballast water and sediments ' was adopted, it is necessary to accept the international convention in Korea. The systems of foreign countries for ship's ballast water control and management were investigated, and domestic environment-related laws were reviewed and compared regarding the discharge of industrial wastewater and ship's ballast water. Alternative measures of domestic legislation were suggested for acceptance of the international convention.

  • PDF

Design of the Real-time Water Tank Wireless Control System in a Ship Using the RF and PLC (RF와 PLC를 이용한 실시간 선박용 물탱크 무선 제어 시스템 설계)

  • Park, O.D.;Lee, S.H.;Kim, H.S.;Long, Nguyen Phi;Hieu, Nguyen Hoang;Kim, H.S.;Cha, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.288-290
    • /
    • 2006
  • This paper presents the real-time water tank wireless control in a ship using duplex RF modules and PLC(Programmable logic Controller). The purpose of this paper is developing HMI(Human Machine Interface) for automation equipments. The system can low a cost because long wires are no more used. Analog signals of the water gauge and flow meter are changed to discrete signals by the micro-processor. The PLC checks the volume of water and runs On or Off of the valve and pump. Duplex RF modules send and receive data between the water tank and control room. Everywhere the Internet is used, operators are able to check the status of the system by the web-server.

  • PDF

Mini PC control system for BYG type water supply units (BYG형 급수기의 MINI PC 제어 시스템)

  • 박용규;강영모
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.1167-1171
    • /
    • 1993
  • A highly efficient hydropneumatic water supply system type BGY is designed and built in accordance with ISO standard. The technical features of BYG type pump unit can be summarized as follows: - reduce hydropneumatic tank capacity at the ratio of 1/10 - 1/30 compared with conventional method. - ISO standard pumps can be used. - the development of highly efficient water supply system type BYG is based on long-term experiences with the proven constant pressure water supply technique which minimize pressure fluctuation, rapid pilsation, etc. The text contains the operation principle of BYG type water supply system, introduction of closed cycle control process focused on Mini PC and experimental results of type BYG-IVS-90x45.

  • PDF

A Study on the status of unit water content control of the Ready-Mixed Concrete plants in the country (국내 레미콘 플랜트의 단위수량관리 현황 검토에 관한 연구)

  • Jung, Yang-Hee;Kim, Yong-Ro;Choi, Il-Ho;Lee, Do-Bum;Hong, Kyung-Seon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.606-609
    • /
    • 2006
  • In this study, it was selected that in order to make an investigation into the status of the unit water content control of the ready-mixed concrete plants in the country, Capacitance Measurement Method out of various methods which are able to gauge the amount of unit water content in fresh concrete. Then, it were estimated that the quantity of unit water in fresh concrete and the technical standard of every mixture design of the six ready-mixed concrete plants chosen at random in the country. Finally, based on this study, it was proposed as fundamental data to utilize measurement techniques of the quantity of unit water for the quality control of the ready-mixed concrete in construction field.

  • PDF