Examination on High Vibration of Recirculation System for Feed Water Piping in Combined Cycle Power Plant (복합 발전소 주급수 재순환 배관계의 고진동 현상 및 대책)

  • Kim, Yeon-Whan;Kim, Jae-Won;Park, Hyun-Gu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.648-654
    • /
    • 2011
  • The feed-water piping system constitutes a complex flow impedance network incorporating dynamic transfer characteristics which will amplify some pulsation frequencies. Understanding pressure pulsation waves for the feed-water recirculation piping system with cavitation problem of flow control valve is very important to prevent acoustic resonance. Feed water recirculation piping system is excited by potential sources of the shock pulse waves by cavitation of flow control valve. The pulsation becomes the source of structural vibration at the piping system. If it coincides with the natural frequency of the pipe system, excessive vibration results. High-level vibration due to the pressure pulsation affects the reliability of the plant piping system. This paper discusses the piping vibration due to the effect of shock pulsation by the cavitation of the flow control valves for the recirculation piping of feed-water pump system in combined cycle power plants.

  • PDF

Algicidal Activity of a Dibenzofuran-Degrader Rhodococcus sp.

  • Wang, Meng-Hui;Peng, Peng;Liu, Yu-Mei;Jia, Rui-Bao;Li, Li
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.2
    • /
    • pp.260-266
    • /
    • 2013
  • Rhodococcus sp. strain p52, a previously isolated dibenzofuran degrader, could effectively inhibit the growth of cyanobacteria, including species of Microcystis, Anabaena, and Nodularia. When strain p52 was inoculated at the concentration of $7.7{\times}10^7$ CFU/ml, 93.5% of exponentially growing Microcystis aeruginosa ($7.3{\times}10^6$ cells/ml initially) was inhibited after 4 day. The threshold concentration for its algicidal activity against M. aeruginosa was $7.7{\times}10^6$ CFU/ml. Strain p52 exerted algicidal effect by synthesizing extracellular substances, which were identified as trans-3-indoleacrylic acid, DL-pipecolic acid, and L-pyroglutamic acid. The effective concentrations of trans-3-indoleacrylic acid and DL-pipecolic acid against M. aeruginosa were tested to be 0.5 mg/l and 5 mg/l, respectively.

Anti-diabetic Effect of Dried-silkworm Dongchunghacho in Streptozotocin-induced Diabetic Rats (Streptozotocin 유발 당뇨모델을 이용한 건조누에 동충하초의 항당뇨 효과)

  • Lee, June-Woo
    • The Korean Journal of Food And Nutrition
    • /
    • v.30 no.4
    • /
    • pp.665-672
    • /
    • 2017
  • The anti-diabetic effect of dried-silkworm Dongchunghacho water extracts was investigated in streptozotocin (STZ)-induced diabetic rats. Seven-week-old SD rats were randomly assigned to six groups: normal control (NC) group, diabetic control (DC) group, water extracts of Paecilomyces japonica grown on a dried-silkworm (PJ-DS, 50 mg/kg) group, PJ-DS (250 mg/kg) group, water extracts of Cordyceps militaris grown on a dried-silkworm (CM-DS, 250 mg/kg) group, and water extracts of dried-silkworm (DS, 250 mg/kg) group. These groups were orally provided with sample dissolved in water respectively for four weeks after an injection of STZ (60 mg/kg, ip) followed by identification of diabetic control (DC) group. After four weeks, body weight of all diabetic groups was significantly lower than that of the normal control (NC) group, but among diabetic groups there were no significant differences. Blood glucose levels of the PJ-DS (50 mg/kg), PJ-DS (250 mg/kg), CM-DS (250 mg/kg) and DS (250 mg/kg) groups were reduced compared to the DC group by 3.0 percent, 18.5 percent, 6.9 percent and 13.1 percent, respectively. Concentration of total cholesterol and triglyceride in blood plasma were to some degree decreased in PJ-DS (250 mg/kg) and DS (250 mg/kg) groups compared to the DC group. According to these results dried-silkworm Dongchunghacho water extracts (PJ-DS) boost protection against STZ-induced toxicity.

A Study on the Method of Estimating Optimum Supply Water Temperature Considering the Heating Load and the Heat Emission Performance of Radiant Floor Heating Panel (난방부하와 온수온돌의 방열성능을 고려한 적정 공급온수온도 산출방법에 관한 연구)

  • Choi, Jeong-Min;Lee, Kyu-Nam;Ryu, Seong-Ryong;Kim, Yong-Yee;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.795-800
    • /
    • 2006
  • A common approach to achieve better thermal comfort with hydronic radiant floor heating system is supply water temperature control. This is the control method through which supply water temperature is varied with outdoor temperature. In this study, a comprehensive, yet simple calculation method to find optimum supply water temperature is evaluated by combining heat loss from the building and heat emission from the hydronic radiant floor heating system. And then the control performance of suggested calculation method is confirmed through experiment. It is shown that indoor air temperature is stably maintained around the set point.

  • PDF

A Fundamental Study on the Improvement of Harbour Tranquility and Water Quality of Fishing Port (어항의 정온도 향상과 수질개선을 위한 기초적 연구)

  • Ryu, Cheong-Ro;Kim, Jong-Hwa;Park, Jong-Hwa
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.4
    • /
    • pp.341-352
    • /
    • 1990
  • The purpose of this research is to develop the design/control method that can be used for the improvement of harbour tranquility and water quality of fishing ports. For this end, firstly, the hydraulic environmental characteristics of fishing ports in the coastal waters of the Korean Peninsula are analysed and discussed combined with disasters of facilities and vessels in the ports. Secondly the problems of water quality control is pointed out considered with the improvement measures of harbour tranquility such as the methods of lengthen of main breakwaters and construction of wave absorbing structures. Finally, the control characteristics of composite functions of water quality and tranquility of fishing port are discussed and the improved control method si proposed using the experimental results for the various measures. The proposed measure is proved to be a applicable method to improve these two main functions on the design of fishing port.

  • PDF

The Optimum Control Study for Improving Efficiency of the small hydropower generation in water pipe (수도관로 소수력발전 운영효율 향상을 위한 최적제어 방안)

  • Hong, Jeong-Jo;Rim, Dong-Heui;Kim, Soo-Sang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.126-129
    • /
    • 2008
  • Using a surplus head in presented water supply pipes, we have studied to improve the operating efficiency of small hydro generator, which was chosen for a test model with Sung-Nam and Bo-Ryong small hydro power plant. With regard to power control and countermeasure of water hammer impact, Finally we have represented the optimal control method through the synthetical analysis of existing system symptoms, operation efficiency, the effect of water hammer impact and system configuration.

  • PDF

A Study on the Membrane Fouling Control by Ozone-Scrubbing (오존세정(洗淨)에 의한 막(膜) 폐색(閉塞) 억제(抑制)에 관한 연구(硏究))

  • Kim, Hyung-Soo;Fujita, Kenji
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.3
    • /
    • pp.78-87
    • /
    • 1995
  • A study on the fouling control by periodical ozone-scrubbing was conducted in a membrane filtration process for drinking water treatment. Hydrophilic hollow fiber polyethylene membrane with pore size of $0.1{\mu}m$ and its surface area of $0.42m^2$ was used. Dead-End filtration method was selected to obtain high efficiency of energy. Laboratory prepared synthetic raw water with kaolin was used and the membranes were scrubbed by ozone once in an hour and once in two hours. When the duration of ozone scrubbing was increased from 10 seconds to 20 seconds, the rate of membrane fouling was significantly decreased. Although the frequency of ozone-scrubbing was reduced from once in an hour to once in two hours. the effect of fouling control was unchanged. However, ozone-scrubbing was not effective after a membrane was fouled and washed with detergent for reuse. Among several possible working effects of ozone, bactericidal effect was confirmed to be the primary reason of fouling control.

  • PDF

Design of Robust $H^{\infty}$ Controller for Water Level Control of Steam Generator (증기발생기 수위 제어를 위한 견실$H^{\infty}$ 제어기 설계)

  • 서성환;조희수박홍배
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.223-226
    • /
    • 1998
  • The control objective of steam generator water level in the secondary circuit of a nuclear power plant is to regulate the water level at the desired set point. The dynamics of steam generators is non-linear in nature. The task of modelling such plant is very difficult and especially so when plant operating conditions change frequently. In these reasons, conventional PI gains over all pover range will not work efficiently and a manual control is generally used in low power operation. Therefore the robust H$\infty$ controller design method should be required. In this paper, we design the robust H$\infty$ controller for water level control of steam generator using a mixed H$\infty$ optimization with model-matching method. Firstly we choose the desired model that has good disturbance rejection performance. Secondly we design a stabilizing controller to keep the model-matching error small and also provide sufficiently large stability margin against additive perturbations of the nominal plant.

  • PDF

Design of Satellite System for the Back-up System of Unmanned Control Plant

  • Chung, Kee-Heon;Yoon, Young-Hwan;Byun, Doo-Gyoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.170.4-170
    • /
    • 2001
  • Safety and confidence of the communications network is the main purpose for the unmanned control systems, in terms of appling a satellite communications network to the water treatment and supply plant communication system. Since the unmanned control systems were applied in the industrial site, the lack of confidence on the communications network has been presented continuously as a main problem for the unmanned and automation systems. Therefore, satellite communications network was presented as one of the methods to solve this problem, supporting the wire used telecommunication. In addition to the safety of a communications network, there is the retrenchment of expenditure. This dual communications network has ...

  • PDF

A Study on the Thermal Fields Control using a Floating-type Current Control Structure (부유식 해수유동제어구조물의 유동제어 특성에 대한 연구)

  • Boo, Sung-Youn
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.2 s.32
    • /
    • pp.147-158
    • /
    • 1999
  • Warm or waste water discharged from offshore-based facilities often causes environmental polution as it is transported to coastal area due to tidal actions. In this research a floating-type current control structure is introduced in order to reduce the pollutant spreading in the coastal area. Effectivenss of the structure is investigated through the numerical experiment which is based on a 3-D finite difference multi-level scheme. The warm-water spreading in the bay is reduced when the draft of the structure increases and its optimum draft is found to be between 0.25h and 0.65h, where h is the water depth. The proposed structure is also tested in the Gohyun Bay and it ts proven to be applied to controllling pollutant spreading if its draft is properly chosen.