• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.046 seconds

Comparative study on the efficiency of pesticide residue removal in foods (Perilla Leaves, Strawberries, Apples)

  • Seung-Woon Myung
    • Analytical Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • In agricultural households cultivating vegetables and fruits, the use of various pesticides to protect crops from diseases and pests or to control weeds is widely practiced enhancing quality and productivity. However, pesticides can pose a threat to consumer health by remaining on the food surface or migrating into the food interior. Households commonly peel off skins, wash with water, or use chemical methods to remove foreign substances including residual pesticides on the food surface. In this study, we measured the washing rate by comparing the pesticide concentrations before and after washing in the leafy vegetable perilla leaves and the fruits strawberries and apples, which were intentionally exposed to pesticides. We compared washing rates using tap water, a baking soda solution, and a commercially available food-specific cleaning solution. The target pesticides for analysis were azoxystrobin, bifenthrin, boscalid, difenoconazole, flubendiamide, and indoxacarb, and the residual pesticide analysis was performed using GC-MS/MS or LC-MS/MS. The removal rates of pesticides were highest with the food-specific cleaner, followed by baking soda and tap water in order.

The Efficacy of Ozonated Water Therapy on Pododermatitis of Dairy Cows (젖소 족피부염(足皮膚炎)에 대한 오존수의 치료(治療) 효과(效果))

  • Lee, Soo-Jin;Cho, Sung-Whan;Jun, Moo-Hyung;Kim, Duck-Hwan;Park, Chang-Sik;Han, Hong-Ryul;Kim, Myung-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.23 no.3
    • /
    • pp.272-278
    • /
    • 2006
  • This study was carried out to determine therapeutic the effect of ozonated water therapy on bovine pododermatitis. In addition, bactericidal effect of ozonated water on etiological agent of bovine pododermatitis was examined. The pathohistological examination for the pododermatitis, according to application with ozonated water and ozone ointment was investigated. Thirty healthy cattle were divided two groups(each of 15) : control group(povidone group), treatment group(ozone solution group). Various parameters were evaluated in terms of the lameness score, swelling score, lesion score, WBC count, neutrophil count, pathohistological finding, and antimicrobial action. The decrease of lameness and lesion score were shown in hoof lesions on 14 days after application of ozonated water. Significant decrease of swelling was shown in hoof lesions on 14 days 1Corresponding author after application of ozonated water(p<0.01). In hematological findings, WBC count revealed values within normal range. The number of neutrophils was slightly higher than that of normal, however, this was improved on 14 days after application of ozonated water. In pathohistological findings, recovery was rapid macroscopically and microscopically in the treatment with ozonated water on the hoof lesions and ozonated water was effective. In antimicobial action, bactericidal effect was observed in treatment with ozonated water on the hoof lesions and ozonated water was effective.

Analysis of the Difference of Flow Duration Curve according to the Cumulative Variation of the Daily Average Flow in Unit Watershed for TPLCs (총량관리 단위유역 일평균유량의 시계열 누적 변화에 따른 유량지속곡선 차이 분석)

  • Hwang, Ha-sun;Rhee, Han-pil;Seo, Ji-yeon;Choi, Yu-jin;Park, Ji- hyung;Shin, Dong-seok;Lee, Sung-jun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.6
    • /
    • pp.97-109
    • /
    • 2018
  • The LDC (Load Duration Curve) method can analyze river water quality changes according to flow rate and seasonal conditions. It is also possible to visually recognize whether the target water quality is exceeded or the size of the reduction load. For this reason, it is used for the optimal reduction of TPLCs and analysis of the cause of water pollution. At this time, the flow duration curve should be representative of the water body hydrologic curve, but if not, the uncertainty of the interpretation becomes big because the damaged flow condition is changed. The purpose of this study is to estimate the daily mean flow of the unit watershed using the HSPF model and to analyze the difference of the flow duration curves according to the cumulative daily mean flow rate using the NSE technique. The results show that it is desirable to construct the flow duration curve by using the daily average flow rate of at least 5 years although there is a difference by unit watershed. However, this is the result of the water bodies at the end of Han River basin watershed, so further study on various water bodies will be necessary in the future.

Conjunctive Management Considering Stream-Aquifer Systems for Drought Season (지표수 지하수 연계운영에 의한 갈수기 지표수-수자원관리)

  • Cha, Kee-Uk;Kim, Woo-Gu;Shin, Young-Rho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.389-394
    • /
    • 2008
  • The purpose of this research was to develop a methodology to determine whether conjunctive surface water and groundwater management could significantly reduce deficits in a river basin with a relatively limited alluvial aquifer. The Geum River basin is one of major river basins in South Korea. The upper region of the Geum River basin is typical of many river basins in Korea where the shape of river basin is narrow with small alluvial aquifer depths from 10m to 20m and where most of the groundwater pumped comes quickly from the steamflow. The basin has two surface reservoirs, Daecheong and Yongdam. The most recent reservoir, Yongdam, provides water to a trans-basin diversion, and therefore reduces the water resources available in the Geum River basin. After the completion of Yongdam reservoir, the reduced water supply in the Geum basin resulted in increasing conflicts between downstream water needs and required instream flows, particularly during the low flow season. Historically, the operation of groundwater pumping has had limited control and is administered separately from surface water diversions. Given the limited size of the alluvial aquifer, it is apparent that groundwater pumping is essentially taking its water from the stream. Therefore, the operation of the surface water withdrawals and groundwater pumping must be considered together. The major component of the conjunction water management in this study is a goal-programmin g based optimization model that simultaneously considers surface water withdrawals, groundwater pumping and instream flow requirements. A 10-day time step is used in the model. The interactions between groundwater pumping and the stream are handled through the use of response and lag coefficients. The impacts of pumping on streamflow are considered for multiple time periods. The model is formulated as a linear goal-programming problem that is solved with the commercial LINGO optimization software package.

  • PDF

A Study on the Activation of Non-government Participation in Total Maximum Daily Load System using Private Discharge Facilities Reduction Potential Analysis (개별배출시설 삭감잠재량 분석을 통한 수질오염총량제의 민간참여 활성화 방안 연구)

  • Kim, Hongtae;Shin, Dongseok;Kim, Hyeonjeong;Choi, Inuk;Lee, Miseon;Kim, Yongseok
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.6
    • /
    • pp.715-722
    • /
    • 2015
  • Four major river basin in Korea has been managed with Total Maximum Daily Load(TMDL) System. Water quality indicators as targeted pollutants for TMDL were BOD and TP. In order to satisfy water quality criteria, government allocation using public treatment facilities and its action plan has been used. However, the role to improve water quality were recently faced to its limitation. It is time to require the role of non-government allocation in private discharge facilities to control good water quality. This study investigated three different scenarios in reduction demands of non-government allocations about industry and private sewages. The three different scenarios were discharge under 1) legal water quality standard, 2) water quality level in 2011 and 3) current water quality level with maximum value in group. The results showed that reduction potential in water discharge for TP indicator was 1,118kg/day, under second scenario with 20% of deduction. This results arrived at 42% of whole reduction potential costs and 0.012mg/L improvement in water quality. In conclusion, to intrigue voluntary participation in non-government allocation, various benefits such as tax reduction, tax exemption, and water quality trading should be provided.

Priority Selection of Water Quality Improvement Through Water Quality Data of Tributaries of Nakdong River (낙동강수계 지류 수질자료를 통한 수질개선 우선순위 선정)

  • Shim, Kyuhyun;Shin, Sangmin;Kim, Seongmin;Kim, Youngseok;Kim, Gyeonghoon
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.5
    • /
    • pp.364-372
    • /
    • 2020
  • The "Master Plan for the Revitalization of Water in the Nakdong River" is designed for the fundamental improvement of water quality in the Nakdong River. The water quality and flow of the Nakdong River system tributaries was monitored in this study. Among the living environmental standard parameters of 195 rivers, BOD (Biochemical oxygen demand), T-P (Total phosphorus) and TOC (Total organic carbon) were assessed to analyze the water quality from 2012 to 2019. We examined the role of TOC. It was found that 12 rivers exceeded the water quality of the second grade (3.0 mg/L BOD standard, 0.1 mg/L T-P standard, 4.0 mg/L TOC standard) based on BOD and T-P concentrations: the Gumi stream, Gisegok stream, Yongha stream, Yongho stream, Changnyeong stream, Gajwa stream, Gwangok stream, Yeongsan stream, Toerae stream, Hwapo stream, Sangnam stream and Hogye stream. These rivers require strategies to improve the quality of the Nakdong River. Based on the ongoing project, it is possible to supplement the "Master Plan for the Revitalization of Water in the Nakdong River" and manage it after verifying it as a component of people's life and therefore used to establish water quality control measures.

Water and Sodium Balance of Body Fluid (체액의 수분 및 나트륨 균형)

  • Kim, Ji-Hong
    • Childhood Kidney Diseases
    • /
    • v.14 no.2
    • /
    • pp.111-119
    • /
    • 2010
  • The maintenance of the osmolality of body fluids within a very narrow physiologic range is possible by water balance mechanisms that control the intake and excretion of water. Main factors of this process are the thirst and antidiuretic hormon arginine vasopressin (AVP), secretion regulated by osmoreceptors in the hypothalamus. Body water is the primary determinant of the osmolality of the extracellular fluid (ECF), disorders of body water homeostasis can be divided into hypo-osmolar disorders, in which there is an excess of body water relative to body solute, and hyperosmolar disorders, in which there is a deficiency of body water relative to body solute. The sodium is the predominant cation in ECF and the volume of ECF is directly proportional to the content of sodium in the body. Disorders of sodium balance, therefore, may be viewed as disorders of ECF volume. This reviews addresses the regulatory mechanisms underlying water and sodium metabolism, the two major determinants of body fluid homeostasis for a good understanding of the pathophysiology and proper management of disorders with disruption of water and sodium balance.

Analysis of Water Qulity changes & Characterization at the Watershed in Han River Basin for Target indicator in TMDLs (수질오염총량관리 대상물질 확대를 위한 한강수계 하천수질 경향 및 수질특성 분석)

  • Choi, Ok Youn;Kim, Hong Tae;Seo, Hee Seung;Han, Ihn Sup
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.15-33
    • /
    • 2017
  • Based on the existing pollutant emissin standards which are armed at the pollutant concentration of each pollution source, government formulated and implemented new management system of total water pollutant emission. By virtue of this new management system, pollution loading amount of individual watershed could be controlled, which achieved the requirement of water quality management such as TP and BOD. In initiate stage of it's implement, BOD was selected as object of water quality management, While it's necessary to consider the continuity of water quality data and established pollutant management laws and policy. During the ongoing management, TP management was added into the system while simply BOD management was not enough. However, the frequency of algae bloom in Han-river showed a trend of same, even though TP was treated as additional control target. Therefore, this paper will analyze different water quality parameters and characteristic of water quality, so that this study can be provide as reference for watershed management of water quality, by which the applicable management period and target pollutant can be selected in the future.

LS-SVM Based Modeling of Winter Time Apartment Hot Water Supply Load in District Heating System (지역난방 동절기 공동주택 온수급탕부하의 LS-SVM 기반 모델링)

  • Park, Young Chil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.9
    • /
    • pp.355-360
    • /
    • 2016
  • Continuing to the modeling of heating load, this paper, as the second part of consecutive works, presents LS-SVM (least square support vector machine) based model of winter time apartment hot water supply load in a district heating system, so as to be used in prediction of heating energy usage. Similar, but more severely, to heating load, hot water supply load varies in highly nonlinear manner. Such nonlinearity makes analytical model of it hardly exist in the literatures. LS-SVM is known as a good modeling tool for the system, especially for the nonlinear system depended by many independent factors. We collect 26,208 data of hot water supply load over a 13-week period in winter time, from 12 heat exchangers in seven different apartments. Then part of the collected data were used to construct LS-SVM based model and the rest of those were used to test the formed model accuracy. In modeling, we first constructed the model of district heating system's hot water supply load, using the unit heating area's hot water supply load of seven apartments. Such model will be used to estimate the total hot water supply load of which the district heating system needs to provide. Then the individual apartment hot water supply load model is also formed, which can be used to predict and to control the energy consumption of the individual apartment. The results obtained show that the total hot water supply load, which will be provided by the district heating system in winter time, can be predicted within 10% in MAPE (mean absolute percentage error). Also the individual apartment models can predict the individual apartment energy consumption for hot water supply load within 10% ~ 20% in MAPE.

Effect of cooling water temperature on the temperature changes in pulp chamber and at handpiece head during high-speed tooth preparation

  • Farah, Ra'fat I.
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.1
    • /
    • pp.3.1-3.10
    • /
    • 2019
  • Objectives: It was the aim of this study to evaluate the effect of cooling water temperature on the temperature changes in the pulp chamber and at the handpiece head during high-speed tooth preparation using an electric handpiece. Materials and Methods: Twenty-eight intact human molars received a standardized occlusal preparation for 60 seconds using a diamond bur in an electric handpiece, and one of four treatments were applied that varied in the temperature of cooling water applied (control, with no cooling water, $10^{\circ}C$, $23^{\circ}C$, and $35^{\circ}C$). The temperature changes in the pulp chamber and at the handpiece head were recorded using K-type thermocouples connected to a digital thermometer. Results: The average temperature changes within the pulp chamber and at the handpiece head during preparation increased substantially when no cooling water was applied ($6.8^{\circ}C$ and $11.0^{\circ}C$, respectively), but decreased significantly when cooling water was added. The most substantial drop in temperature occurred with $10^{\circ}C$ water ($-16.3^{\circ}C$ and $-10.2^{\circ}C$), but reductions were also seen at $23^{\circ}C$ ($-8.6^{\circ}C$ and $-4.9^{\circ}C$). With $35^{\circ}C$ cooling water, temperatures increased slightly, but still remained lower than the no cooling water group ($1.6^{\circ}C$ and $6.7^{\circ}C$). Conclusions: The temperature changes in the pulp chamber and at the handpiece head were above harmful thresholds when tooth preparation was performed without cooling water. However, cooling water of all temperatures prevented harmful critical temperature changes even though water at $35^{\circ}C$ raised temperatures slightly above baseline.