• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.043 seconds

Development of High Performance LonWorks Fieldbus Control Modules for Network-based Induction Motor Control (네트워크 기반 유도전동기 제어를 위한 고성능 LonWorks 제어모듈 개발)

  • Kim, Jung-Gon;Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.319-324
    • /
    • 2005
  • The interface between host processor and the ShortStack Micro Server may be a Serial Communication Interface(SCI). The LonWorks control module with a high performance is developed, which is composed of the 8 bit PIC Microprocessor for host processor and the smart neuron chip for the ShoretStack Micro Server. This intelligent control board is verified as proceeding the various function tests from experimental system with an boost pump and inverter driving systems. It is also confirmed that the developed control module provides stably 0-10VDC linear signal to the input signal of inverter driving system for varying the induction motor speed. Thus, the experimental results show that the fabricating intelligent board carried out very well the various functions in the wide operating ranges of boost pump system. This developed control module expect to apply to industrial fields to require the comparatively exact control and monitoring such as multi-motor driving system with inverter, variable air volume system and the boost pump water supply systems.

  • PDF

Development of Heat Control Valve Using SMA and Remote Controller for House Heating System (형상기억합금을 이용한 난방용 온도조절 밸브 및 원격 제어장치 개발)

  • Choi, Jeongju;Yeom, Jeongkuk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.2
    • /
    • pp.6-11
    • /
    • 2010
  • For the purpose of reducing the energy consumption in the house heating, the various devices have been developed. One of these is to control the flow in the heat pipe and the flow control valve using shape memory alloy(SMA) spring is proposed in our study. The proposed house heating system is to save the gas consumption and the remote control system is designed for the convenience of using the proposed valve. The developed valve consists of SMA spring, disk, return spring, and regulation handle. The regulation handle is for supplying the additional hot water and is controlled by remote-control-motor. In order to design the remote control system, the Zigbee wireless communication protocol is used. The performance of the proposed valve structure is shown through the experimental result.

The Current technology state of "Supervisory Control And Data Acquisition System(SCADA)" and development plan in the city-gas industry (긴급제언 - 원격감시제어시스템의(SCADA) 기술현황과 도시가스산업에서의 발전방안)

  • Choi, In-Hwan
    • Journal of the Korean Professional Engineers Association
    • /
    • v.43 no.3
    • /
    • pp.28-33
    • /
    • 2010
  • The related industrial technologies are also being developed in medicine, education, the military, transportation, process management, security management and information technology industries due to a rapid progress in telecommunications technology. The supervisory remote control system is based upon telecommunications technology. The supervisory remote control systems are used in various ways such as city gas, water supply and drainage, environment, power, communication and device control fields. The supervisory remort control system became a solution with complex systems and important technologies in electricity, city gas filed that require safety management skills. The supervisory remote control system as a special technology has a lot of practical applications. In this paper, Let me examine the present status of remort control system applications and present development plans and alternatives in city-gas industrial technology.

  • PDF

Control characteristics of a refrigerant compressor test facility (냉매압축기 성능시험장치의 제어 특성)

  • Lee, J. Y.;Lee, D. Y.;Kim, K. H.;Nam, P. W.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.46-51
    • /
    • 1999
  • This paper describes the control charcteristics of thermal/flow systems. In thermal/flow systems, the transport lag plays as a dead time causing a deterioration of the controllability. Besides this, such many parameters including the temperature, pressure, and flow rate affect the system response that a control scheme which can deal with multi-input is required. Particularly in a refrigerant compressor test facility, the evaporator and condenser interact each other so that the change in the evaporator pressure cause the condenser pressure to change or vice versa. Therefore, to control the evaporator pressure, not only the cooling water flow rate in the evaporator but also the coolant flow rate in the condenser is considered. Meanwhile, the conventional PID controllers, which is suitable for a single input system, shows a large overshoot for a disturbance input. In this work, the predictive control scheme is introduced and its applicability is discussed for thermal/flow systems.

  • PDF

The Study for reducing accidents using the Data Base of Water Treatment Plant (수도 정보를 활용한 사고저감 방안 연구)

  • Seo, Gangdo;Yun, Youngmin;Kim, Haksung;Hwang, Jaemoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.138-141
    • /
    • 2015
  • K-water operates many Water Treatment Plants(WTP) to supply clean water to people. There are automation process control equipments collecting data at each step in WTP. The data collected is big enough to 370,000Tag/min from the K-water Water Treatment Plants. In the past, this big data was not important, we focused on the operating water purification process using the data. Currently, we increased the importance of attention to take advantage of Big Data. The research about the accident reduction and efficiency improvement in WTP are ongoing by data collection and analysis. In this paper, we analyzed the flow rate, power and pressure obtained in the accident case in WTP. We researched the methods for accident prediction and reduction.

  • PDF

Water Jet Experiment of Automatic Fire-tracking Water Cannon Facility combined with Indoor Hydrant Facility in Road Tunnels (도로터널의 옥내소화전설비 겸용 자동화점추적 방수총설비의 방수실험)

  • Kim, Chang-Yong;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.92-98
    • /
    • 2019
  • To determine if water-jet nozzle moves and water jetting are effective according to the location of the fire, this study examined the automatic fire-tracking water cannon system and aan indoor hydrant system, such as water jet centered directivity, water jet range maintainability and water jet shape uniformity. First, an examination to find the center of fire accurately from this system design showed that the water jet centered test was accurate. Second, the water jet range test results showed that when water is jetted at the maximum water jet radius, the water jet shows an inaccurate result but within the allowable tolerance range. Finally, the water-jet shape test result confirmed that there are no problems in setting the block from the algorithm design.

Analysis on drinking water use change by COVID-19: a case study of residential area in S-city, South Korea (COVID-19 확산에 따른 상수도 사용량 변화 분석: 국내 S시 주거지역을 대상으로)

  • Jeong, Gimoon;Kang, Doosun;Kim, Kyoungpil
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.1
    • /
    • pp.11-21
    • /
    • 2022
  • The COVID-19 started to spread at early 2020 in South Korea and has been threatening our life in many aspects. Countermeasures such as social distancing to prevent COVID-19 spread have brought many changes in our society an human life. In this study, as a part of the COVID-19 pandemic management, drinking water usage change is analyzed to evaluate potential risks on water supply service. We collected hourly water use data of residential area in S city, which is a mid-size city in South Korea, before and after the COVID-19 pandemic. The collected data were analyzed to reveal the changes in total water consumption, water usage weight, and hourly water-demand pattern caused by the COVID-19 pandemic. The case study revealed the noticeable changes in water consumption caused by the COVID-19 pandemic and required more secured and adaptive operation of drinking water system under the pandemic situation caused by infectious disease.

Effect of Different Rates of Ethanol Additive on Fermentation Quality of Napiergrass (Pennisetum purpureum)

  • Zhang, Lei;Yu, C.Q.;Shimojo, M.;Shao, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.5
    • /
    • pp.636-642
    • /
    • 2011
  • The effect of different rates of ethanol additive on fermentation quality of napiergrass (Pennisetum purpureum) and residual water soluble carbohydrate were studied in the experiment. The addition rate of ethanol was 0%, 1.5%, 2.5%, 3.5%, 4.5% on fresh weight of napiergrass. The laboratory silos were kept in the room, then were opened on 1, 3, 5, 7, 14, 30 days after ensiling and the changes of silage quality were analyzed, respectively. There was a fast and large reduction in pH from the 5th day of ensiling to below 4.2 except for the 4.5% treatment. After five days the pH of silage decreased slowly and the pH of the ethanol additions was lower than the control. Lactic acid content of ethanol treatments increased significantly (p<0.05) from the 5th day of ensiling, reaching the highest value on either the 7th day or 14th day. The ethanol additive inhibited the break down of silage protein and the ammonia nitrogen content of ethanol addition silage was significantly (p<0.05) lower than the control after 30 days of ensiling. Within the initial first day of ensiling the water soluble carbohydrate content declined quickly. The efficiency of water soluble carbohydrate usage was higher in silage with ethanol than in the control. The acetic acid of ethanol treatment was significantly (p<0.05) lower than control on first and 14th day, but there was no significant (p>0.05) difference among the ethanol addition silages. The volatile fatty acids content of silage increased gradually from the first day of ensiling and reached the peak on 14th day or 30th day and the content of ethanol addition treatment was significantly (p<0.05) lower than the control. The experimental results indicated that adding ethanol inhibited the use of protein and water soluble carbohydrate of aerobic bacteria and reduced the silage losses during the early stage of ensiling and thus supplied more fermentation substrate for lactic acid bacteria and improved the fermentation quality of napiergrass.

The effects of Hyangbujapalmultang on Learning and Memory of AD Rats using Morris water maze paradigm (향부자팔물탕(香附子八物湯)이 Alzheimer's disease 모델 백서(白鼠)의 학습과 기억에 미치는 영향(影響))

  • Kang Hyun-Geun;Kim Jong-Woo;Whang Wei-Wan
    • Journal of Oriental Neuropsychiatry
    • /
    • v.10 no.1
    • /
    • pp.39-51
    • /
    • 1999
  • The effects of Hyangbujapalmultang on the enhancement of learning and memory of AD model rats were studied with Morris water maze. Sample group was electrolytically lesioned on nucleus basalis of Meynert(nbM), and then daily treated with the medicine for two months. Control group with nbM lesion, and sham group with the sham operation were treated the vehicle for the same duration. The following results were observed. 1. As the learning trials of Morris water maze were proceeded, sham group showed the escape latency from $54.7{\pm}2.28$ seconds in 1st trial to $13.3{\pm}3.27$ seconds in 7th. The control group showed the escape latency from $58.0{\pm}1.78$ seconds in 1st trial to $51.3{\pm}3.52$ seconds in 7th. The sample group showed the escape latency from $57.0{\pm}2.21$ seconds in 1st trial to $28.4{\pm}4.82$ seconds in 7th. Therefore, these data shows that all three groups were improved in learning capacity as trials were proceeded, but the sample group showed more prominent improvement in learning compared with the control group(p<0.05). 2. In memory retention test of Morris water maze that counts the staying time in the target area during 30 seconds of freely swimming period, sham group stayed for $4.81{\pm}1.15$ seconds, the control group stayed for $1.27\pm}0.78$ seconds, and the sample group stayed for $4.17{\pm}1.47$ seconds. The analysis of the memory retention data shows that the sample group marked more improvement in memory retention compared with the control group, but could not obtained statistically significant result(p<0.05). With the experimental results above, Hyangbujapalmultang can be supposed to have the improving effects on the learning of AD model rats induced by electrolytic lesion of nbM.

  • PDF

Studies on the Development of weed Control Method for Paddy Rice by Bensulfuron-methyl Combination Suspension Concentrate (Bensulfuron-methyl 혼합(混合) 액상수화제(液狀水和劑)의 사용법(使用法) 개발(開發) 연구(硏究))

  • Ryu, G.H.;Park, J.E.;Lee, I.Y.;Lee, H.G.;Lee, J.O.;Park, Y.S.;Shin, H.S.
    • Korean Journal of Weed Science
    • /
    • v.14 no.1
    • /
    • pp.28-33
    • /
    • 1994
  • This study was conducted to investigate the efficacy of weed control by pyributicarb{O-[3-tert-butylphenyl] N-[6-methoxy-2-pyridyl]-N-methyl thiocarbamate}/bensulfuron-methyl{methyl 2-[[[[[[4, 6-dimethoxypyrimidin-2-yl] amino] carbonyl] amino] sulfonyl] methyl] benzoate} SC and oxadiazon{5-tert-butyl-3-[2,4-dichloro-5-isopropoxyphenyl]-1,3,4-oxadiazol-2(3)-one}/bensulfuron-methyl SC, and to develope weed control methods for paddy rice. There was little difference between suspension concentrate and granule of pyributicarb/bensulfuron-methyl and oxadiazon/bensulfuron-methyl combination in the effect of weed control. Pyributicarb/bensulfuron-methyl SC and oxadiazon/bensulfuron-methyl SC were diffused from the point of application to 6m. Pyributicarb/bensulfuron-methyl SC applied on water surface from irrigation inlet and in paddy water from dike controlled more than 90% of weeds. Pyributicarb/bensulfuron-methyl SC was precipitated about 1-2cm per 1 hour after dripping on water surface. The efficacy of weed control by pyributicarb/bensulfuron-methyl SC was higher in 0-1cm than in 6-7cm standing water depth.

  • PDF